Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC HOUSE NO 415 ALIKAN ROAD MANDI DABWALI SIRSA HARYANA 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.3 L+₹2.2 L (16.4%)Rejected-Finance NOT FOUND | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.6 L+₹2.4 L (18.4%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹15.9 L+₹2.8 L (21.2%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹14.6 L
EMD Value
₹29,200
Closing Date
25 Feb 2023, 6:00 pmClosed
GE (AF) Sirsa
GE (AF) Sirsa-125055
Special Repair to Replacement of BER Ceiling Fans, Coolers, Geysers and Other Associated Works at AF Stn Sirsa
2023_MES_575370_1
GE/SRA/T-54/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Sirsa
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Sirsa
₹29,200
Yes
9 Mar 2023
17 Jan 2023
27 Feb 2023
17 Jan 2023
25 Feb 2023
31 Jan 2023
18 Jan 2023 - 25 Jan 2023
Amount
M&L for taking down indoor and outdoor unit of split air conditioner and voltage stablizer of any size/capacity including copper pipe and connection lead and depositing in MES store yard including making good the disturbed surface to match with existing wall finish complete all as specified and as directed by Engr-in-charge.
M&L for taking down ceiling fan, exhaust fan, desert cooler of any size/capacity and depositing in MES store yard complete all as specified and as directed by Engr-in-charge.
M&L for taking down geyser of any size/capacity and depositing in MES store yard including making good the disturbed surface to match with existing wall finish complete all as specified and as directed by Engr-in-Charge.
S&F air cooled inverter type, split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated, energy efficiency ratio >3.6, cooling capacity should be more or equal to 5250 watt, Refrigerant environmentl friendly R410a, condenser type copper ( grooved), Compressor- Rotary type, supply 220 V, copper pipe should be min 12 feet in length which has to be installed with machine. All accessories which shall be required to istall the AC ( including MS angle stand, Minimum 2.5 mtr drain pipe, digital remote with battery). Additional feature should be Automatic Humidity Control, Corrosion Resistance Coating, dust filter, turbo mode, Green Anti Bacterial Eva Coils, anti bacteria filter and color od AC should be in milky/off Whilte Only .The supplier shall be liable for warranty for minimum period of 12 months for AC and 5 years for compressor. (Make - Lloyd, Model No: GLS18I55WBHL or euivalent model in Daikin/Carrier)
S&F desert cooler plastic/PVC body honeycomb type cooling media, 24 Litre or higher water tank capacity, 3 speed, minimum 2450 CFM air flow, minimum 20 feet air throw, copper wounded motor 220 V, 50 HZ and 1350 rpm complete all as specified and directed. (Make- Havells, Model- Kalt - GHRACAAD008 or equivalent make in Khaitan/Symphony/Voltas/Bajaj)
Supply and Hanging, ceiling fan, with brushless DC motor, 1200 mm sweep with down rod, canopy, fan blades and accessories and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.0 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan complete all as specified and directed. (MAKE : USHA, Model: ENERGIA 32 / CROMPTON GREAVES, Model : ENERGION HS / ORIENT, Model: ECOTECH / PANASONIC, Model: BLDC F-12XDA / HAVELLS, Model: Efficiencia Neo)
S&F exhaust fan 300 mm sweep, 900 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as spcified and directed. (MAKE : HAVELLS, Model: Turbojet SP / CROMPTON, Model: EXHD300-6-1 / USHA, Model: Turbo Heavy Duty or equivalent model in BAJAJ / ORIENT)
All as per Item no. 07 above but exhaust fan of 380 mm sweep (MAKE : HAVELLS, Turbojet SP / CROMPTON, EXHD380-6-1 / USHA, Turbo Heavy Duty or equivalent model in BAJAJ)
Supply, installation, testing and commissioning of heater water storage type electric geyser (vertical cylindrical type) 25 litres capacity with BEE 5 star rating (min) and ABS body, glass lined/titanium enamel coated inner tank incl fixing arrangement, clamps, nuts & bolts etc alng with providing suitable capacity flexible cable 3 core with 3 pin plug of 16 amps and stainless steel connection pipes of adequate length complete all as specified and directed. (Make: RACOLD, Model - CDR DLX / AO SMITH, Model- HSE-VAS / Havells, Model: Monza Dx / BAJAJ, Model: CALDIA)
Supply, installation, testing and commissioning of heater water storage type electric geyser (vertical cylindrical type) 50 litres capacity with BEE 5 star rating (min) and ABS body, glass lined/titanium enamel coated inner tank incl fixing arrangement, clamps, nuts & bolts etc alng with providing suitable capacity flexible cable 3 core with 3 pin plug of 16 amps and stainless steel connection pipes of adequate length complete all as specified and directed. (Make: RACOLD, Model - CDR DLX / AO SMITH, Model- HSE-VAS / Havells, Model: Monza Dx / BAJAJ, Model: CALDIA)
shiv shanker enterprises
UNITED ENGINEERING CORPORATION
NISHTHA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .