Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.3 LAccepted-AOC | L1 | Accepted-AOC Lower amount quoted | |
| 2 | L2₹93.6 L+₹25,932.79 (0.28%)Rejected-Finance DHALIWAL | L2 | Rejected-Finance Higher amount quoted | |
| 3 | L3₹93.6 L+₹27,549.80 (0.30%)Rejected-Finance VILL JIAR P O CHOURI TEH SUJANPUR DISTT HAMIRPUR H P | SUJANPUR | HAMIRPUR | HIMACHAL PRADESH | L3 | Rejected-Finance Higher amount quoted | |
| 4 | L4₹94.9 L+₹1.6 L (1.72%)Rejected-Finance | L4 | Rejected-Finance Higher amount quoted | |
| 5 | L5₹1.0 Cr+₹9.9 L (10.6%)Rejected-Finance HIMACHAL PRADESH HP | SHIMLA | HIMACHAL PRADESH | 171226 | L5 | Rejected-Finance Higher amount quoted |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
27 Feb 2025, 12:00 pmClosed
Executive Engineer JSV Flood Prot. Division Gagret
Executive Engineer JSV Flood Prot. Division Gagret
Construction of Civil work, Laying, Jointing and Testing of Rising Main, P/L Distribution system and S/E of Pumping Machinery for Tubewell Shivpur Pandra, Tubewell Sagnai and Tubewell Kailash Nagar.
2025_HPIPH_99794_1
JSV/FPDG/EA-I/2024-25/9106-12 dt. 11.02.2025
Open Tender
Civil Works
Item Rate
90 days
Executive Engineer JSV Flood Prot. Division Gagret
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,000
Executive Engineer JSV Flood Prot. Division Gagret
₹2.1 L
30 May 2025
11 Feb 2025
27 Feb 2025
11 Feb 2025
27 Feb 2025
11 Feb 2025
11 Feb 2025 - 27 Feb 2025
Amount
Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft / hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including, shoring, strutting, planking, timbering and dewatering, wherever required, stacking the useable and unuseable material/ soil separately and after laying, jointing and testing of pipes returing the useable soil in trenches in 15 cm ( Fifteen centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil / un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts and to the entire satisfaction as per the directions of Engineer-in-Charge.
Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinths in all leads and lift and to the entire satisfaction of Engineer-in-charge
Providing and laying cement concrete 1:6:12 (1cement: 6 sand) 12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work in foundation and plinths in all leads and lift and to the entire satisfaction of Engineer-in-charge.
1st.class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:4 (1cement :4 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.
1st. class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 (1 cement : 6 sand) in all lead and lifts and as per the directions of the Engineer-in-Charge.
Filling in plinth with sand under floors including watering ramming consolidating and dressing complete under flooring complete in all respect including carriage of materials in all leads and lifts
P/L RCC seismic beam in cement concrete work 1:2:4(1cement:2sand: 4 graded stone aggregate 20mm nominal size & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in Foundations,footings bases of columns and the like and mass concrete complete in all respect including carriage of materials in all leads and lifts
Providing and laying cement concrete work 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of from work and reinforcement for reinforced concrete work in Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level complete in all respect including carriage of materials in all leads and lifts
1st. class brick work using common burnt clay building bricks in superstructure in cement mortor 1:6 (1 cement :6 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.
Half brick work using common burnt clay building bricks in superstructure above 1st floor level in cement mortar 1:4( 1Cement, 4 Sand ) of 2nd class bricks complete in all respect with in all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to giv a fair finish including centring. shuttering. strutting and propping etc with wooden battens and ballies. height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu-reinforced concrete and plain concrete work in Flat surfaces such as soffits of suspended floors, roofs, landings and the like floor etc.upto 200mm in thickness including carriage of materials within all leads and lifts complete as per the direction of Engineer-in-charge.
Vertical sufaces such as walls any thickness partitions and the like including attached pillasters buttresses, plinth and string courses and the like :-
Flat surfaces such as soffits of suspended floor, roofs, landings and like floors etc. upto 200 mm in thickness
Sides and soffits of beams,beam haunching, lintels etc. :-
Providing tor steel reinforcement for RCC work including bending, binding and placing in positon complete including carriage of material in all leads & lifts complete as per the direction of Engineer-in-charge.
15mm cement plaster in single coat in fair side of brick/stone masonery for interior plastering upto floor two level including arrises,internal,founded angles,chamfers and/or rounded angles chamfers and/or rounded angles not exceeding in girth & finished even and smooth in cement mortar 1:6(1cement:6sand) complete in all respect including carriage of materials in all leads and lifts
15 mm cement plaster in single coat on fair side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and /or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:3 ( 1 cement :3 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.
15 mm cement plaster in single coat on rough side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and /or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:3 ( 1 cement :3 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.
20mm cement plaster in single coat in Rough side of interior plastering upto floor two level including arrises,internal,founded angles,chamfers and/or rounded angles chamfers and/or rounded angles not exceeding in girth & finished even and smooth in cement mortar 1:6(1cement:6sand) including carriage of material in all leads & lifts
6 mm thick cement plaster in C.M.1:3 to ceiling with in all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge.
Pointing on brick work with cement mortar 1:3 ( 1 cement : 3 sand) within all leads and lifts complete to entire satisfaction as directed by the Engineer-in-charge
P/ F pressed steel door frames manufactured from commercial MS sheets of 1.25mm thickness including hinges, jump lock jamp. Bead and if required angle threshold of MS angle 50 x 25 mm or base tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamp i/c steel butt hinges 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of steel primer after pretreatment or surface as directed by Engineer-in-charge.
Providing and fixing 1mm thick M.S.sheet door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junctions and corners including all necessary fittings, complete including applying a priming coat of red lead paint.using flat 30mm x6mm for diagonal braces and control cross/pieces complete in all respect including carriage of material in all leads & lifts.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6water borne stone aggregate 20mm nominal size)including finishing the surface of concrete smooth complete in all respect including carriage of material in all leads & lifts.
50 mm thick CC 1:2:4 flooring laid in one layer & finished with a floating coat of neat cement complete in all respect including carriage of material in all leads & lifts.
40 mm thick CC 1:2:4 flooring laid in one layer & finished with a floating coat of neat cement complete in all respect including carriage of material in all leads & lifts.
Providing 40x3 mm flat iron hold fast 40 cm. Long including fixing to frame with 10 mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm. 1:3:6 (1 cement : 3 sand : gragded stone aggregate 20mm nominal size) complete in all respect including carriage of material in all leads & lifts.
Providing and fixing M.S. grills of required pettern in windows frames of windows etc. with M. S. Flats Square or round bars with round headed bolts and nuts or by screws. (Plain grill) complete in all respect including carriage of material in all leads & lifts.
Providing and fixing M.S.Handles with necessary screws complete in all respect ( 125 mm ) complete in all respect including carriage of material in all leads & lifts.
Providing and fixing M.S.Tower bolts ( Barrel type ) with necessary screws complete in all respect ( 200X10 ) complete in all respect including carriage of material in all leads & lifts.
Providing and fixing sliding door bolts,black enamelled with nuts and screws complete in all respect ( 250X16 ) complete in all respect including carriage of material in all leads & lifts.
P/F on wall face Cast Iron rain water pipe 100mm dia i/c fitting and joints with spun yarn and cement mortar 1:2(1cement:2sand ) including clamps complete in all respect including carriage of material in all leads & lifts.
Applying a priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works complete in all respect including carriage of material in all leads & lifts.
Painting two coats With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) complete in all respect including carriage of material in all leads & lifts.
White washing with lime on undecorated wall surfaces two coats to give & even shade i/c thorougly brooming the surface to remove all dirt, dust mortar & other foreign matter. complete in all respect including carriage of material in all leads & lifts.
Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces ( Two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect including carriage of material in all leads & lifts.
Providing and fixing M.S fan clmp type 1 of 16 mm dia M.S bar bent to shape with hooked ends in R.C.C slab during laying including painting the exposed portion of loop, all as per standard design complete in all respect including carriage of material in all leads & lifts.
Steel work welded in built up sections,trusses & framed work including cutting, hoisting & fixing in position & applying a priming coat of red lead paint In grating, framed, guards, bars, ladders, railing, brackets & similar works within all leads and lifts as per direction of Engineer-in-charge.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant(HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required including carriage of all material within all leads and lifts. Group "C"
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in recessed PVC Conduct along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of materials within all leads and lifts.
Wiring for light plug with 2X1.5 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conduct of cable in recessed PVC conduit along with 1 No. 1.5 Sq. mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carrige of material with in all leads and lifts.
Wiring for circuit/sub main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed conduit along with 1 No. 1.5 Sq mm HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required including carriage of material upto all leads an lift 2X2.65 Sq mm.
Supplying & fixing metal box of 180mm.x100mm.x60mm. deep sizes (nominal size) on surface or in recess with suitable size phenolic laminated sheet covered in the front including Providing and fixing 5 pin 5/6 amps socket , outlet and 5/6 amps piano type switch connections painting etc. as required arriage of materials within all leads and lifts.:-
Supplying and fixing bakelite batten/angle holder including connections as required.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible,cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-Ceiling Fan 1200 mm sweep, Category-A.
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snao-on installers suitable for 28 watt FTL (T5), complete with all accessories (excluding one No.T-5 Tube), connections, testing and commissioning etc. as required. 1 x28 watt-FTL(T5) (Category-A)
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, "C" curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. Double pole Cat.A
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess completed with tinned, copper bus-bar, wire set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification levels interconnections,phosphatized and power painted, including earthing etc. as required Bus bar 8 way.Double Door 8 way
Supplying and errection 6 Amps to 32 Amps rating 10 KA Breaking capacity 240 volts C Curves miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. as required Category "A", single pole.
Providing installation testing and commissioning of prewired flourscent tube fitting 1x40 watt box type Cat A i.e Bajaj make complete with balast starter and capacitor but excluding flourscent tube rod suitable to operate on 240 volt single phase AC supply directly on surface with copper wiring as required complete as per direction of the Engineer-in-charge.
Providing, fixing & testing Street Light Fixture 40 watt, (4feet long) complete with chock starter i/c connection complete as perdirection of Engineer-In-Charge
Providing & Laying, jointing & testing in trenches following dia and grade having suitable pressure Kg.F/ cm2 working pressure polythene pipes high density conforming to IS: 4984-1995 complete but ends preparead for Heat/Electric joints including testing of Joints complete( Earth work in trenches to be measured and paid for separately) within all leads and lifts and as per direction of Engineer-in-charge.
180 mm dia HDPE pipe class PE-80, grade PN 4.00
Providing. and fixing Cast Iron Alfa valves of reputed & approved make like Kirloskar/Leaderetc. on distribution system of confirming to IS:780-1984 with latest ammendments of appropriate class & following dia metre and capable to with stand the requisite nominal seat pressure 10Kg/ Sqmt including testing and upto entire satisfaction of Engineer -in-Charge
200 mm dia
Laying, jointing and testing in trenches Galvanized mild steel flanged/butt welded pipes below mentioned dia and grade conforming to IS:1239-2004 (with latest amendments)The MS Flanges are to be provided for 5% of total joints as per table below conforming to IS:6392-1971 (latest upto date amendments) and welding of MS flanges with pipe as per IS: 816-1969 with electrodes as per IS:814-1991 including required number and size of MS nuts and bolts as per IS 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3.00mm in thickness as per IS:27121-1965. The welding of flanges to be done on both faces in three layers in each face to make the joints leak proof including all kind of specials such as bends of all degrees to be made from parent tube, short pieces, tail pieces all made from parent tube and to the entire satisfaction of the Engineer-in-Charge. The pipes end should be bevelled suitable for butt welding. the circumferencial butt welded joints (95% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make joints leak proof and to achieve the minimum effective throat thickness of welded conforming to IS 816-1969 specifications, by using welding electrode of 2.5mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make conforming to IS 814-1991, at site of work complete in all respect and including DPT test for joints & manual/mechanical handling of pipes.The laying of Pipes conform to IS 5822 (with latest ammendentments upto date) including all kind of specials such as bends of all degrees to made from parent tube, short pieces, tail pieces all amde from parent tube within all leads and lifts (Earth work in trenches, MS flanges and butt welded joints to be measured and paid for seperately) )
GMS pipe 150 mm dia ( Medium grade) 4.80 mm thick P.E.
Providing, welding and fixing of MS flanges @ 5% of total joints conforming to table as specified below of BIS-6392-1971 ( Latest with upto date ammendments) welding of M.S. flanges on ( Two layers on inner face and one layer on outer face of each flange) with GMS pipes and bends on both ends. ( The GMS pipe to be measured and paid for separately. ) The welding of flanges should conforming to IS 816-1998 with electrodes as per IS 814-1997, Prov.& fixed with nuts, bolts of required size conforming to IS 1364, including providing & fixing 3 mm (Minimum) thick compressed asbestos fibre / synthetic rubber gasket conforming relevant BIS Code IS 2712-1965( The earth work in trenches to be measured and paid for seperately) complete in all respect and including entire carriage of materials in all leads and lifts as per the direction of the Engineer-in-Charge
MS Flanges 150 mm dia Table- 5
Providing circumferential butt welded joints @ 95% by electrical are welding to GMS ERW pipe welded in rerqusite number of weld runs so as to achiev the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welging electrodeds of 2.5 mm to 6.3 mm of Advani Oeriliken ( adore)-CITOJET/ES/ESAB make conforming to IS 814-1991 include Die pentration test at site of work complete in all respects, including manual/ mechanical handling of pipe in all leads asnd lifts to the entire satisfaction of Engineer-in- charge.150mm dia.
GMS pipe 150 mm dia 4.80 mm thick
Tubewell at Shivpur Pandra Supply and errection of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Groundfos/ LUBI /Hindustan/ Sabar/Seerex/Johnston / Amrut, conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments, suitable for raw /clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications The pump shall be directly coupled to submersible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge =( Q) 18.84 LPS
Total Head =( H)78.12 Mts.
a) SWL in Tubewell = 6.09 Mtr. bgl.
c) R.L. point of discharge =482.03 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.00 Mtrs.
e) Drawdown in Tubewell =27.44 Mtrs.
g) Static head 61.25 mtrs
g) Static Column lift 52.53 mtrs.
Rising main. Column Pipe.
Length 720 Mtrs. Length 52.53 Mtr.
Dia meter. 150 mm Dia 125 mm
Class GMSERW Class GMS. (M)
Pumping hours 4763.58 hours
Altitude of installations above M.S.L. 100 mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well 123 mtr.
Dia of T/ well assembly 300/200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 100 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing. ii) layout Plan.
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. iv) Capacity.100 amp
ii) ELR of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR 1) Make. ii) Type iii) Range. iv) Capacity. up to 100 amp
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 9 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sluice valve of Leader / Kirloskar/ Kartar/LP brand make of 125 mm dia for the Column pipe of pump and capable of withstanding the normal seat pressure and as per BIS 780-1984 with latest ammendments Class ASA 300 For Column Pipe 125 mm dia Sluice valve i) Make ii) Class PN-1 iii) Material cast Iron
Providing and fixing double flanged swing type cast Iron Reflux valves of Leader/ Kirloskar/ Kartar/LP brand make of 150 mm dia Class PN 1.00 for rising main of pump and capable of with standing the normal seat pressure and as per IS: 5312-1984 with upto date ammendments. 150 mm dia Reflux Valve i)Make ii) Class PN-1.00 iii)Test working head. iv) Material:-Cast Iron
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 16 mm2 (iii) Core=3
Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column pipe i) Size 125 mm dia ii) Class (M) iii) Length
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 16 mm2 ii) Make iii) Type iv) Capacity v) core B) Motor side i) Size 25 mm2 ii) Make iii) Type iv) Capacity v) core
Providing and fixing double loop earthing with GI plate of 600x600x6.3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. Beyond 35 HP to 50 HP -GI flat 25x3 mm
Tubewell at Sagnai Supply and errection of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Groundfos/ LUBI /Hindustan/ Sabar/Seerex/Johnston / Amrut, conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments, suitable for raw /clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications The pump shall be directly coupled to submersible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge =( Q) 21.28 LPS
Total Head =( H) 43.42 Mts.
a) SWL in Tubewell = 10.67 Mtr. bgl.
c) R.L. point of discharge =484.50 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.00 Mtrs.
e) Drawdown in Tubewell =10.67 Mtrs.
g) Static head 33.50 mtrs
g) Static Column lift 40.34 mtrs.
Rising main. Column Pipe.
Length 200 Mtrs. Length 40.34 Mtr.
Dia meter. 150 mm Dia 125 mm
Class GMSERW Class GMS. (M)
Pumping hours 4814.99 hours
Altitude of installations above M.S.L. 100 mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well 146 mtr.
Dia of T/ well assembly 300/200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing. ii) layout Plan.
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. iv) Capacity.63 amp
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR 1) Make. ii) Type iii) Range. iv) Capacity. up to 63 amp
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 6 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sluice valve of Leader / Kirloskar/ Kartar/LP brand make of 125 mm dia for the Column pipe of pump and capable of withstanding the normal seat pressure and as per BIS 780-1984 with latest ammendments Class ASA 300 For Column Pipe 125 mm dia Sluice valve i) Make ii) Class PN-1 iii) Material cast Iron
Providing and fixing double flanged swing type cast Iron Reflux valves of Leader/ Kirloskar/ Kartar/LP brand make of 150 mm dia Class PN 1.00 for rising main of pump and capable of with standing the normal seat pressure and as per IS: 5312-1984 with upto date ammendments. 150 mm dia Reflux Valve i)Make ii) Class PN-1.00 iii)Test working head. iv) Material:-Cast Iron
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 6 mm2 (iii) Core=3
Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column pipe i) Size 125 mm dia ii) Class (M) iii) Length
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 16 mm2 ii) Make iii) Type iv) Capacity v) core B) Motor side i) Size 16 mm2 ii) Make iii) Type iv) Capacity v) core
Providing and fixing double loop earthing with GI plate of 600x600x6.3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. Beyond 20 HP to 30 HP -GI wire
Tubewell at Kaliash Nagar Supply and errection of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Groundfos/ LUBI /Hindustan/ Sabar/Seerex/Johnston / Amrut, conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments, suitable for raw /clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications The pump shall be directly coupled to submersible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge =( Q) 21.25 LPS
Total Head =( H) 92.80 Mts.
a) SWL in Tubewell = 36.58 Mtr. bgl.
c) R.L. point of discharge =533.23 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.00 Mtrs.
e) Drawdown in Tubewell =21.34 Mtrs.
g) Static head 74.29 mtrs
g) Static Column lift 76.92 mtrs.
Rising main. Column Pipe.
Length 570 Mtrs. Length 76.92 Mtr.
Dia meter. 150 mm Dia 125 mm
Class GMSERW Class GMS. (M)
Pumping hours 4682.05 hours
Altitude of installations above M.S.L. 100 mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well 139.50 mtr.
Dia of T/ well assembly 300/200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity :125 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing. ii) layout Plan.
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. iv) Capacity.100 amp
ii) ELR of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR 1) Make. ii) Type iii) Range. iv) Capacity. up to 100 amp
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 11 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sluice valve of Leader / Kirloskar/ Kartar/LP brand make of 125 mm dia for the Column pipe of pump and capable of withstanding the normal seat pressure and as per BIS 780-1984 with latest ammendments Class ASA 300 For Column Pipe 125 mm dia Sluice valve i) Make ii) Class PN-1 iii) Material cast Iron
Providing and fixing double flanged swing type cast Iron Reflux valves of Leader/ Kirloskar/ Kartar/LP brand make of 150 mm dia Class PN 1.00 for rising main of pump and capable of with standing the normal seat pressure and as per IS: 5312-1984 with upto date ammendments. 150 mm dia Reflux Valve i)Make ii) Class PN-1.00 iii)Test working head. iv) Material:-Cast Iron
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 16 mm2 (iii) Core=3
Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column pipe i) Size 125 mm dia ii) Class (M) iii) Length
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 35 mm2 ii) Make iii) Type iv) Capacity v) core B) Motor side i) Size 16 mm2 ii) Make iii) Type iv) Capacity v) core
Providing and fixing double loop earthing with GI plate of 600x600x6.3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. Beyond 35 HP to 50 HP -GI Flat 25x3 mm(35 to 50 HP)
Sahil ohri (BID ID -497300)
Pawan Kumar Sharma (BID ID -495880)
Vivek Dhiman (BID ID -497535)
Mr. Sanjeev Kumar (BID ID -495988)
Vipan Kumar (BID ID -497546)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .