| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.4 CrAccepted-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹6.4 Cr Quoted ₹6.6 Cr | 1 | Accepted-AOC Due to lower rate |
| 2 | 2₹7.3 Cr+₹70.4 L (10.7%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹7.3 Cr+₹70.4 L (10.7%) | 2 | Rejected-AOC Due to higher rate |
| Sl No | Description | Qty | Unit | ROHTASH KUMAR CONTRACTOR L2 | Rajesh Kadiyan Contractor L1 |
|---|---|---|---|---|---|
| 1.10 | Boring/excavation including pit making at entry and exist point to the precise dimensions for the launch of the specialized auger boring machine in rock/bolders any underground utility like foundation water supply pipe line coming in alignment or other under gound obstruction various location complete in all respect including caution sign boards signals watching fencing site clearance etc For 1100 mm dia 14 mm thick MS. casing pipe | 60 | Mtr. | 11,500 ₹6,90,000 | 2,000 ₹1,20,000 Lowest |
| 1.20 | Cleaning of surface of MS pipe (casing pipes) inner surface and outer surface by sand blasting at site to make the surface ready for P.U. coating and high build epoxy paint / polythene tap system complete in all respect. | 129.97 | Sqm | 250 ₹32,492.5 | 125 ₹16,246.25 Lowest |
| 1.30 | Coating of 1100 mm dia MS pipe outer and inner surface of casing and carrier pipe with 100% elastomeric polyurethane coating to AWWA - C2A / C222-1999 specifications to 1000V dry fil thickness for protection against corrosion complete in all respect (1100 mm dia). | 129.97 | Sqm | 350 ₹45,489.5 Lowest | 440 ₹57,186.8 |
| 1.40 | Insertion of water carrier pipe 800 mm RCC NP3 Pipe into 1100 mm dia MS Pipe including jointing and cutting etc complete in all respect including cartage of material at site of work (800 mm RCC NP3 pipe will be included in the DNIT) | 60 | Per Mtr. | 3,590 ₹2,15,400 Lowest | 7,500 ₹4,50,000 |
| 1.50 | Probe Radar survey to check any underground obstruction before finalizing the alignment complete in all respect with the satisfaction of
Engineer - In - Charge. | 1 | Job | 1,00,000 ₹1,00,000 Lowest | 1,60,000 ₹1,60,000 |
| 1.60 | Providing and fixing H.D.P.E specter at a distance of 2 meters a part to avoid contract of casing pipe and carrier pipe complete in all respect | 30 | Each | 2,000 ₹60,000 Lowest | 8,200 ₹2,46,000 |
| 1.70 | Providing and inserting of MS casing pipe Fe 3300 grade fabricated as per IS 3589 of 991 from steel plants confirming to IS 2062 and IS 1216/98 of size 800mm i/d including cutting Beveling gridlining and radio Graphically welding of pipe as per IS-1182 complete in all respect and cleaning of surface and coating of inner and outer surface of arising pipe with high build epoxy paint to RDSO as per specification no M and C/PCN III/88 to a dry film thickness of 250 micron for protection against corrosion including testing and cartage of material to site of work complete in all respect (For 1000 mm dia 14mm thick MS casing pipe) | 60 | Per Mtr. | 45,000 ₹27,00,000 Lowest | 48,500 ₹29,10,000 |
| 1.80 | Providing concrete block 1:11/2:3 on both ends to plug the angular space between casing pipe including cost of 5 mm thick M.S end plate.
Complete in all respect. | 2 | Job | 25,500 ₹51,000 Lowest | 27,000 ₹54,000 |
| 1.90 | Provision for supplying, Installation and testing of HT / LT Panel Board suitable for 3 Phase, 4 Wire, AC supply as per specifications for Clear
Water pumping sets for supplying the drinking water facilities complete in all respect. For IPS pumping sets of 70.00 HP | 5 | Each | 1,00,000 ₹5,00,000 Lowest | 1,00,000 ₹5,00,000 Lowest |
| 2.00 | Provision for supplying, Installation and testing of HT/LT Panel Board suitable for 3 Phase, 4 Wire, AC supply as per specifications for Raw
water pumping sets proposed to be installed for existing and proposed water treatment plant complete in all respects. For IPS pumps of 100 HP for IPS | 5 | Each | 1,40,000 ₹7,00,000 Lowest | 1,50,000 ₹7,50,000 |
Tender Value
₹6.6 Cr
EMD Value
₹13.1 L
Closing Date
1 Apr 2026, 3:00 pmClosed
EXECUTIVE ENGINEER
Narwana PHED
providing and laying of storm water drain, construction of 3 Nos. IPS, laying of rising main
2026_HRY_510890_1
2026854B756B 77FF 4AC5 9835 1038086C0123570PUH
Open Tender
Civil Works
Works
365 days
Narwana
4 documents required · 4 mandatory
₹20,000
₹13.1 L
Yes
21 May 2026
25 Mar 2026
1 Apr 2026
25 Mar 2026
1 Apr 2026
25 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.1 | Boring/excavation including pit making at entry and exist point to the precise dimensions for the launch of the specialized auger boring machine in rock/bolders any underground utility like foundation water supply pipe line coming in alignment or other under gound obstruction various location complete in all respect including caution sign boards signals watching fencing site clearance etc For 1100 mm dia 14 mm thick MS. casing pipe | 60 | Mtr. | - | - |
| 1.2 | Cleaning of surface of MS pipe (casing pipes) inner surface and outer surface by sand blasting at site to make the surface ready for P.U. coating and high build epoxy paint / polythene tap system complete in all respect. | 1 | Sqm | - | - |
| 1.3 | Coating of 1100 mm dia MS pipe outer and inner surface of casing and carrier pipe with 100% elastomeric polyurethane coating to AWWA - C2A / C222-1999 specifications to 1000V dry fil thickness for protection against corrosion complete in all respect (1100 mm dia). | 1 | Sqm | - | - |
| 1.4 | Insertion of water carrier pipe 800 mm RCC NP3 Pipe into 1100 mm dia MS Pipe including jointing and cutting etc complete in all respect including cartage of material at site of work (800 mm RCC NP3 pipe will be included in the DNIT) | 60 | Per Mtr. | - | - |
| 1.5 | Probe Radar survey to check any underground obstruction before finalizing the alignment complete in all respect with the satisfaction of
Engineer - In - Charge. | 1 | Job | - | - |
| 1.6 | Providing and fixing H.D.P.E specter at a distance of 2 meters a part to avoid contract of casing pipe and carrier pipe complete in all respect | 30 | Each | - | - |
| 1.7 | Providing and inserting of MS casing pipe Fe 3300 grade fabricated as per IS 3589 of 991 from steel plants confirming to IS 2062 and IS 1216/98 of size 800mm i/d including cutting Beveling gridlining and radio Graphically welding of pipe as per IS-1182 complete in all respect and cleaning of surface and coating of inner and outer surface of arising pipe with high build epoxy paint to RDSO as per specification no M and C/PCN III/88 to a dry film thickness of 250 micron for protection against corrosion including testing and cartage of material to site of work complete in all respect (For 1000 mm dia 14mm thick MS casing pipe) | 60 | Per Mtr. | - | - |
| 1.8 | Providing concrete block 1:11/2:3 on both ends to plug the angular space between casing pipe including cost of 5 mm thick M.S end plate.
Complete in all respect. | 2 | Job | - | - |
| 1.9 | Provision for supplying, Installation and testing of HT / LT Panel Board suitable for 3 Phase, 4 Wire, AC supply as per specifications for Clear
Water pumping sets for supplying the drinking water facilities complete in all respect. For IPS pumping sets of 70.00 HP | 5 | Each | - | - |
| 2 | Provision for supplying, Installation and testing of HT/LT Panel Board suitable for 3 Phase, 4 Wire, AC supply as per specifications for Raw
water pumping sets proposed to be installed for existing and proposed water treatment plant complete in all respects. For IPS pumps of 100 HP for IPS | 5 | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_589693.xls
BOQ • 0.30 MB
777955Z151642.pdf
Additional Documents • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .