Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC VILL SANDIPUR PO DWARNARY DISTT PURBA MEDINIPUR KOLKATA 7134403 WB | KOLKATA | PURBA MEDINIPUR | WB | 7134403 | L1 | Accepted-AOC L1 BID | |
| 2 | L2₹12.3 L+₹54,672.75 (4.66%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L2 | Rejected-Finance BIENG HIGHER THAN L1 BID | |
| 3 | L3₹17.8 L+₹6.1 L (52.1%)Rejected-Finance HALDIA BRAJALALCHAK DAKSHINCHAK BHABANIPUR EAST MEDINIPUR WEST BENGAL 721654 | MEDINIPUR EAST | WEST BENGAL | 721654 | L3 | Rejected-Finance BIENG HIGHER THAN L1 BID |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
1 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (CGN) kolkata
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIR AND MAINTENANCE TO EXTERNAL ELECTRIC SYSTEM OF DHQ-8 JETTY AZADHIND NAGAR AND VIKRAM ENCLAVE AT HALDIA UNDER GE (I) (CGN) KOLKATA
2022_MES_543341_1
8035/B/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (CGN) kolkata
AS PER TENDER DOCUMENT
11 documents required · 11 mandatory
₹500
GE (CGN) kolkata
₹22,000
Yes
18 Nov 2022
4 Aug 2022
2 Sept 2022
4 Aug 2022
1 Sept 2022
18 Aug 2022
Amount
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 120 Sqmm 3 core complete all as specified and as directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as spcified and as directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as spcified and as directed.
M&L for finding out the fault to under ground HT cable by cable fault locator machine all as required and directed by Engr-in-Charge.
M&L for Two pole, mechanically operated (GOD), mounted on insulator and steel frame, with operating mechanism worked from ground level, suitable for 11000 Volts, for current rating upto 200 amps including dismantling and taking down the existing unserviceable one complete all as specified and as directed.
M&L for Servicing / Greasing of HT Switch air break ( GOD) 11 KV TP with replacement of Corroded nut Bolts, ACSR Jumpers, making alignment of operating Mechanism for Proper ON / OFF operation of GOD and male contact including complete greasing all as directed by Engr-in-Charge.
M & L for Painting to HT Steel Tubular Two pole Structure including cross arms, MS Channels , clamps after scrapping thoroughly the existing rust / dirt / dust and corroded paint from the steel surfaces, Painting with Two coats Aluminum paint over a coat of red Oxide Primer, complete all as specified and directed. Note : Also 2 mtr from bottom will be applied Yellow/Red/Yello color radium striop of as approved in alternate layer of 10 cm height of each layer complete greasing all as directed.
Supply only 11 KV Earth Discharge Rod complete greasing all as directed.
S & F lighting Arrester for 11 KV - ( 03 Nos in 01 set ) complete greasing all as directed.
Supply only electrical rubber hand gloves of 15" length suitable for 11 KV complete greasing all as directed.
Supply only HT fuse wire of 18 SWG complete greasing all as directed.
Repair/maintannces of VCB of any make any capacity by disconnecting electric supply , checking /cleaning/decarburisation of the part by part after come out the enter system (spring action lever), connections, bus bar, replace unsv PTs fuses etc and changing of damaged insulators, slip , nuts & bolts, heating the spare parts, hanging the cable glands, thembles/lugs of HT cables, calibration of relay with secondary injection test kit incl submission of calibration report, reassembling and testing & commissioning complete all as specified and as directed. (Note : (i) Maintenance /repairs of VCB shall be carried out by trained technicians/mechanic under super vison of qualified electrical technician. (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate (iii) Major parts/accessoreis for VCB are measured and paid seperately.
S & F 11 KV panel indicating lamp fitting LED type suitable for 24 volt/30volt DC complete with base complete all as specified
S & F 11 KV panel indicating lamp fitting LED type suitable for 110 volt/230volt AC complete with base complete all as specified
S & F limit switch suitable for VCB Panels complete greasing all as directed.
M&L for open the top cover of transformer of capacity 100 KVA to 400 KVA, after disconnecting HT/LT connection, drain out of transformer oil and preserve it in container, replacement of all gasket for prevention of leaking, replacement of broken HT/LT bushes complete as per existing size all as directed, refixing all connection and testing on load. Note : (a) LT/HT side ceramic bushing, spindle for HT/LT side etc. for replacement shall be measured and paid seperately.
Supply & Fix Ceramic Bushing and Gasket on HT Side of Transformer 100KVA to 400KVA 11000/433 complete all as specified and as directed.
Supply & Fix Ceramic Bushing and Gasket on LT Side of Transformer 100 KVA to 400KVA 11000/433 complete all as specified and as directed.
Supply and fix Breather Assembly filled with Silica Gel as Approved complete all as specified and as directed.
Supply & Fix Brass Spindle for Terminal on HT Side Threaded complete with Nut, Washers, etc. of dia as ordered, as Approved and suitable and suitable for Transformer 100 to 400 KVA 11000/433, complete all as specified and as directed.
Supply & Fix Brass Spindle for Terminal on LT Side Threaded complete with Nut, Washers, etc. of dia as ordered, as Approved and suitable and suitable for Transformer 100 KVA to 400KVA 11000/433, complete all as specified and as directed.
M & L for filteration of transformer oil by disconnecting the device from supply and draining out the complete oil, filtering the dirt, sludge and dehumidifying by heating the same and raising the Breakdown voltage level 50 KV at 2.5 mm gap and testing and recording the result for three times in specified interval including pouring the oil in transformer tank and charging the same to restore supply complete all as specified and as directed.
Removing existing old paint by scraping from transformer of capacity 250/400 KVA, Preparation of surfaces including fins and conservator tank, material labour for two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, capacity and date of dehydration/ oil change (top up) in white paint complete all as specified and directed.
M & L for servicing of DG set for every six months or 250 Hrs running which is earlier. Checking of all the lubricant oil, fuel oil, water hose pipes connection, checking pipe line leakage, checking solenoid switch, speedo meter control, coolant temperature, oil pressure, No load RPM, RPM @ load, voltage in lines, current in lines, battery parameters, DG sets vibration,exhaust system, radiator fins for any leakage, cleaning of air filters and also check the on load @ 25%, 50%,75%,100% and 110%. Replacing all the Engine oil, fuel filters, engine oil filters, air filter, solenoid valve, hoses complete all as specified and directed. Note : Replacement of engine oil, lubricants, coolant, filters, primary and secondary elements, actuator, hoses, solenoid switch and battery shall be measured and paid seperately.
All as per item No 26 abive but 100 KVA DG Set Make: Greaves Cotton Ltd Model No : GPWII-PII-100 at Vikram Enclave complete greasing all as directed.
All as per item No 26 abive but 62.5 KVA DG Set Make: KOEL Green by Kirloskar Model No : KG1-62.5WS2 at Vikram Enclave complete greasing all as directed.
All as per item No 26 abive but 25 KVA DG Set Make: Greaves Cotton Ltd Model No : GPWII-PII-25KVA at Azad Hind Nagar complete greasing all as directed.
All as per item No 26 abive but 125 KVA DG Set Make: KOEL Green by Kirloskar Model No : KG1-125WS at Azad Hind Nagar complete greasing all as directed.
All as per item No 26 abive but 500 KVA DG Set Make: Greaves Cotton Ltd Model No : GPWII-500KVA at Jetty Area complete greasing all as directed.
All as per item No 26 abive but 100 KVA DG Set Make: Ashok leyland Model No : LP-100D at CGDHQ complete greasing all as directed.
M & L for Servicing of DC alternator and replacing bearing, carbon brushes, AV plate etc of capacity 24V / 12V complete greasing all as directed.
M & L for Servicing of starter assembly and replacing carbon brush, bearing, bendex pin, rewinding etc. of capacity 24V/12 V complete greasing all as directed.
Supply only KOEL care premium genuine oil complete greasing all as directed.
Supply only KOEL care premium genuine coolant complete greasing all as directed.
Supply only filter for lubricating oil complete greasing all as directed.
Supply only fuel filters complete greasing all as directed.
Supply only primary element filter complete greasing all as directed.
Supply only Actuator sedemac make complete greasing all as directed.
Supply only secondary element filter complete greasing all as directed.
Supply and fix Battery 180 AH for 100 KVA @ vikram enclave Make : Exide, TATA green, Amaraja etc or equivalent complete greasing all as directed.
Supply only Fuel filter cartridge suitable for rotary FIP complete greasing all as directed.
Supply only primary Air filter for 500 KVA complete greasing all as directed.
Supply only lub oil filter 234 for 500 KVA complete greasing all as directed.
Supply only primary element for 6H.413.10.0.00 Air cleaner complete greasing all as directed.
Supply and fix Mild Steel class 'C' diesel pump exhaust pipe upto 3 mtr matching with existing pipe dia with one layer of10mm thick asbestos rope insulation so that the exhaust should be out side of tin shed and including all fitting clamp/ structural steel supports complete all as specified and directed by Engr-in-charge.
M&L for insulating mat of size 2m x lm x 2.5 mm complete greasing all as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 400 Sqmm 3.5 core complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Indoor/Outdoor type
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm,Indoor/Outdoor type
Excavation in trenches, n. exc. 1.5m wide and n. exc. 1.5m in depth; for laying of cable, n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point
M&L fine sand, filling in trench for cable cushioning and gently punned down by manually with hands complete all as specified and directed. cable cushoining complete greasing all as directed.
Material and labour Brick protection cover to LT underground cable with Sub Class 'B' over burnt laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10 mm complete specified and directed.
Supply and laying tubes 40 mm dia steel water tube light grade galvanised with all fittings laid in trenches complete all as specified and as directed.
Supply and laying tubes 50 mm dia steel water tube light grade galvanised with all fittings laid in trenches complete all as specified and as directed.
Decarburizing/ cleaning complete LT 415 volts 3 phase panel/ bus bar chamber with electrical connections complete bus bar from the bus bar chamber, cleaning with CTc, connection of all control cables, welding the broken doors properly and ensure proper decarburizing, refixing the same after applying Backtol red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/ out-going system complete incl replacement of defective rusted bolts & nuts and Removing existing old paint by scraping from LT Panels, material labour for two coats of synthetic enamel paint (1st quality) by spraying only including writing SM/MES No and in/ out going details, capacity in white paint complete all as specified and directed.
M&L for removing electrical/ mechanical connections of old Lt UG cable from MCCB/ busbar of existing LT panel of size from 16 sqmm to 240 sqmm, 3.5/4 core incl cutting/ removing the burnt end/ jointed area after refixing to MCCB/busbar with new aluminium thimble/ lugs set incl covered with proper insulated tape, clamps, nuts, bolts etc if req etc all as specified and directed by Engr-in-charge.
Supply and install ON LOAD change over switch 415V 4 pole of capacity 400 Amps in open execution type fixing in existing panel if req then including necessary modification in the panel and incl dismantling old one. Make L&T/havells/GE
Supply and install ON LOAD change over switch 415V 4 pole of capacity 100 Amps in open execution type fixing in existing panel if req then including necessary modification in the panel and incl dismantling old one. Make L&T/havells/GE
Supply and fixing indication lamp , LED type color RYB complete all as directed.(RYB is count one)
Supply, fixing, testing and commissioning of CT 100-400/5 of CT, class of accuracy class 1 upto 5 VA incl disconnecting old usv meter removed from bus bar, fixing new CT to bus bar with suitable clearance, secondary wiring with FRLS insulated copper conductor and lugs with suitable size complete all as directed.
Supply, fixing, testing and commissioning CT 500-1000/5, class of accuracy class 1 upto 5 VA incl disconnecting old usv meter removed from bus bar, fixing new CT to bus bar with suitable clearance, secondary wiring with FRLS insulated copper conductor and lugs with suitable size complete all as specified and as directed.
M&L for MCCB 4 Pole, 415 V, Adjustable type , with Microprocessor release 630 Amps with breaking capacity 50 KA complete all as specified and as directed.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 320 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 35 KA complete all as specified and as directed.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 35 KA complete all as specified and as directed.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and as directed.
M&L for MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA complete all as specified and as directed.
Supply only lugs of 10 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 16 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 25 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 35 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 50 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 70 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 95 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 120 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 150 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 185 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 240 Sqmm sizes complete all as specified and as directed.
Supply only lugs of 300 Sqmm sizes complete all as specified and as directed.
Maintenance / repair/ servicing of 3 phase servo voltage stabilizer 150 KVA, Make : Aplab checking all the connections, earthing, coils, level of oils, showing parameters by display, display switch for set all parameters, including replacement of necessary unserviceable parts like LED RYB indicator lamps, 4 way porcelain terminal, gaskets, pre sets, toggle switches, display, PCB controller ckt, meters etc complete all as specified and as directed. Note : (i) Connector, PCB controller ckt, Resistance, lugs etc. measured and paid separately under relevant item of this schedule as supply only. (ii) Labour for taking down, dismantling, connecting back and re-fixing shall be included in the unit rate quoted. (iii) Replacement of other minor parts like LED RYB indicator lamps, 4 way porcelain terminal, gaskets, pre sets, toggle switches, dimmer, meters etc are included in quoted rates of this item.
Maintenance / repair/ servicing of 3 phase servo voltage stabilizer (b) 250 KVA, Make : Aplab checking all the connections, earthing, coils, level of oils, showing parameters by display, display switch for set all parameters, including replacement of necessary unserviceable parts like LED RYB indicator lamps, 4 way porcelain terminal, gaskets, pre sets, toggle switches, display, PCB controller ckt, meters etc complete all as specified and as directed. Note : (i) Connector, PCB controller ckt, Resistance, lugs etc. measured and paid separately under relevant item of this schedule as supply only. (ii) Labour for taking down, dismantling, connecting back and re-fixing shall be included in the unit rate quoted. (iii) Replacement of other minor parts like LED RYB indicator lamps, 4 way porcelain terminal, gaskets, pre sets, toggle switches, dimmer, meters etc are included in quoted rates of this item.
Supply only Accessories Connector, lug, resistance etc complete all as specified and as directed.
Supply only SVS PCB Control card Make : SVS complete all as specified and as directed.
S&F Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red color and fixed with M.S clamps, bolts, nuts of approved size for LT 25X20 cm, for HT 25X20 cm size all as directed.
S&F Electric Shock and its treatment Chart prakashan safetic Board of 4 x 3 x 0.5 feet size in three language Hindi, english and Bangali with diagram and fixed with M.S clamps, bolts, nuts of approved size all as specified and directed.
M&L preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of upto 9.00 metre length including MS clamps ,cable protection pipe bracket fitted with street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting from 2.1 mtr height from the top of caping/ bottom of pole as per site condition and numbering of poles complete all as specified and as directed by Engr-in –charge. Note: Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer.
S&F for three pole power contactor, 415 Volts, MNX-12, conform to relevant IS, Range from 12-30 Amp AC-3, I Robust and suitable for hostile applications for street light control including electric connection complete. Make L&T Cat No CS94108 or equivalent in Siemens / ABB.
S&F Digital street light timer Crono 240 VAC base/Din mounting Digital type suitable for street light control including taking down old one complete all as specified and as directed. ( Make : L& T or equivalent)
M&L for PVC cable end terminal boxes outdoor type, 30x20cm, PVC door, sintex box provision for cable incoming and outgoing from bottom, comprising of one MCB SP 6-32 Amps, cable glands suitable and one porcelein connector four way complete fixed on wall/pole with necessary clamps, screw etc all as specified and directed by the Engr-in-Charge. Make : Sintex Model No GSJB 3020 or equivalent.
M&L for LED flood light luminaire 135 Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.Make : Crompton Greaves Cat No : LFLN - 135-CDL/60 or equivalent in Philips/Havells/Bajaj.
S & F Building security light fitting,LED type, suitable for 19W LEDs complete with driver etc mounted on 25 mm dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall with suitable bolts, nuts, saddles including connection with 2 core PVC insulated sheathed flexible cable with mulltistranded copper conductor from celing rose to fitting terminal upto a length of 2m including taking down old CFL security light fitting all as specified and as directed. Make- Philips (Greenline Smart) Cat Part no. BRP042 LED 19 CW MR S1 PSU GR or equivalent in Bajaj/CG
M&L for Unifoldintegral flood light 35 Watt with driver inside a housing, highly efficient,reliable and study compared to similar LED, halogen and metal halide flood light, IP protection 65 class-I, driver intergal connection, incl taking down old one complete all as specified and as directed. (Make: Philips cat part No-BVP120 LED 35 CW FG SI PSU GR or equivalent Havells /Bajaj/CG)
M&L for outdoor inverted pyramid tripod type bollard LED luminaries, 10 watt with IP 65 protection,including suitable size of wire from joint box to connector including taking down old unserviceable fitting complete all specified and directed. Make: CG cat part No-LBLSN-10-CDL or equivalent Havells /Bajaj/philips
M&L Sub main wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit complete fixed to wall / ceiling / pole etc incl one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. (Note :-(i) PVC rigid conduit with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 2.5 sqmm single core cable, one run of 1.5 sqmm earth continuity wire to be measured as one length.
M&L LED Post top lantern decorative 360 deg indirect light 40 Watt LED made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection including taking down old unserviceable fitting all as specified and directed. Make : CG cat No LPTO-40-CDL or equivalent in Philips/havells/bajaj.
M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore,medium grade, 2.5 metres length,buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire and GI pipe 40 mm medium grade for earthing lead protection to the extent of maximum 7.5 m, earth wire electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI bolts & nuts complete all as per Electrical plate No 2 of SSR Part-I, connected to panel/DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4 Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm Dia TMT bars in both ways, MS frame made with 40X40X6 mm angle Iron, MS Funnel with 20 mm bore , medium grade GI watering pipe, wire mesh, earth excavation return filling, removal of surplus soil etc complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead 32x6 mm galvanised strip and GI pipe 50 mm medium grade for earthing lead protection to the extent of maximum 7.5 m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI bolts & nuts complete all as per Electrical plate No 3 of SSR Part-I, connected to panel/DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4 Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm Dia TMT bars in both ways, MS frame made with 40X40X6 mm angle Iron, MS Funnel with 20 mm bore , medium grade GI watering pipe, wire mesh, earth excavation return filling, removal of surplus soil etc complete all as specified and directed.
Supply and fix battery charger of 12 Volt with 5 AH to 250 AH charging capacity for AMF Panel, Bike, Truck baterry charger, DG's battery charger with all leads and all necessary parts of reputed make complete all as specified abnd directed by Engr-in-charge.
M&L for maintenance/ repair of Diesel Engine make of Kirloskar DM 26, 20 HP, 1500 RPM with piston cylinder arrangement and dismantle complete engine and replace the wear out gaskets, nuts, bolts and all necessary parts complete as directed. Notes : (i) Parts required to be replaced shall be included in unit quoted price. However, labour element involved in replacement is included in unit rate quoted against this item. (ii) Necessary work for realignment such as relocation and replacement of foundation bolt shall be deemed included in the rate. (iii) Replacement of brush set, cylinder piston, head joint, nozzle set, greasing, nuts, bolts and other necessory fitting etc involved in quoted prices (iv) Any minor repairs involved to make the motor completely functional, even if not mentioned in this item, shall be carried out by the Contractor without any extra cost to the department.
supply First Aid box including all necessory medicines
supply only 4.5 kg filled CO2 fire extinguiser with guideline and operational manual and including all necessory parts complete all specified and directed by Engr-in-charge.
M&L for repair/ servicing for APFC panel upto 125 KVA capacity, checking all connection and tighting/ refixing and repair the existing unserviceable connection in proper way and setting the capacitor in such a way that power factor is being above 0.95 and also checks all meters fucntioning, indacating light if found any fault in meter then same be replaced/ servicing and replacing the unsv indicating lights, replacing/ split the exist capacitor of 10 KVAr into 2 Nos 5 KVAr and another 12.5 KVAr to 6 & 6.5 KVAr as per site condition complete all as specified and directed by Engr-in-charge. Note : replacement of meters, indicating lights, spliting/ replacing capacitor and any minor/ major parts are inclusive in quoted rate.
Supply and fix Electric Distribution board of 800x600x200 mm size with lighting arrangement and computerized typing with line diagram complete all as specified and directed by Engr-in-charge.
M/s Santosh Industrial Corporation
JOTSHNA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .