Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹5.1 L+₹3,600 (0.71%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹5.6 L+₹51,425 (10.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY |
Tender Value
₹5.1 L
EMD Value
₹10,240
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
SPL REPAIR WORK TO WATER SUPPLY LINES TO BLOCK OF OFFRS MD ACCN (P-146), OFFRS SINGLE LIVING ACCN (P-79), OFFRS MESS COMPLEX (P-121) INCLUDING OFFRS MESS STAFF LIVING AREA AT 663 ARMY AVN (R AND O) AT SHARIFABAD UNDER AGE(I) CIF (K)
2023_MES_597311_1
CA NO. AGE (I) CIF (K)-08/2023-24
Open Tender
Civil Works - Water Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹10,240
Yes
18 Jul 2023
22 May 2023
21 Jun 2023
22 May 2023
19 Jun 2023
5 Jun 2023
Amount
Taking up or down GI water tubing and connections of 20 mm bore, including cleaning for re-fixing or removal from site for the following sizes (bore of pipe), complete all as specified and as directed by the Enginee-in- Charge. Note :- Earth work shall be measured and paid under respective item of BOQ.
Description all as per serial item No 01 here-in-before, but 25 mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Description all as per serial item No 1 here-in-before, but 50 mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Description all as per serial item No 1 here-in-before, but 80 mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Steel water tubing of nominal bore 50 mm, medium grade galvanised ISI marked as per IS:1239 Part-I with all fittings including short lengths, fixed to walls/roof, concealed in wall and ceiling or laid in trenches/floors complete with all fittings ( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by the Enginee-in- Charge.
Description all as per serial item No 5 here-in-before, but 80mm bore, complete all as specified and as directed by the Enginee-in- Charge.
M&L for 25 mm bore, 3- layer PPR (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having therrnal slability for hot & cold water supply all PPR plain & brass threaded polypropylene random fittings, laid in trenches or in floors or in ceiling and fixed to walls, complete all as specified and as directed by the Enginee-in- Charge.
Description all as per serial item No 5 here-in-before, but 32 mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Making connection of 16-40mm dia PPR distribution branch with PPR main by providing and fixing tee including cutting and making fusion joint etc, complete all as specified and as directed by the Enginee-in- Charge.
S&F in replacement 25mm bore PPR Gate valves (brass insert) as per requirement of the site, complete all as specified and as directed by the Enginee-in- Charge.
Description all as per serial item No 5 here-in-before, but 32 mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Plain cement concrete 1:4:8, type D-2, using 40mm graded crushed stone aggregate, as in foundation filling and mass concrete, road cuttings etc., complete all as specified and asdirected by the Engineer-in-Charge.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes, laying pipes CI/GI etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading , leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed by the Engineer-in-Charge.
Cutting existing steel tubing 40mm or 50mm bore for alterations or additions, complete all as specified and as directed by the Engineer-in-Charge.
Taking out damaged broken lagging from pipes and providing lagging to pipes of 25 mm bore, used in internal water supply or plumbing all round with, 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg /cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh, covering with POP layer, complete all as specified and directed at site by the Enginee -in-Charge .
Description all as per serial item No 18 here-in-before, but 32mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Supply and fixing in replacement of CI Sluice valves PN 1.6 flanged and of sizes for 80mm bore complete with iron wheel head and spindle including material and labour for flanged joints and replacement of nuts and washers etc., complete all as specified and as directed by the Engineer-in-Charge.
Brick masonry valve chamber of size 0.60m x 0.6m x 0.6m internal dimension suitable for sluice valve, with 100mm thick PCC (1:3:6) type C-2 for foundation, one brick wall in cement mortar (1:6), 40mm thick PCC (1:2:4) type B-1 for coping, rendering in cement mortar (1:4) 15mm thick internally and externally flush pointed in same mortar as the work proceeds. Flooring shall be 40mm thick in PCC 1:2:4 type B-1 laid over 75mm thick hard core including provision of mild steel sheet cover 3.15mm thick on 40mm x 40 x 6mm angle iron frame work with two coat of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation, earth work and demolishing the damaged valve chamber and removing debris, complete all as specified and directed at site by the Engineer-in- Charge.
Note :- An amount of Rs. 19,150.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
JK BUILDERS AND ENGINEERS
M/S A Q ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .