| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC 1890 NEW SHOBHAPUR COLONY VEHICLE FACTORY ROAD JABALPUR MP 482009 | JABALPUR | MADHYA PRADESH | 482009 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹38.2 L+₹7,249.87 (0.19%)Rejected-Finance 14 L N Y MARKET RANJHI JABALPUR MP 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹39.9 L+₹1.8 L (4.59%)Rejected-Finance D 154 ADARSH NAGAR JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹42.1 L+₹3.9 L (10.3%)Rejected-Finance 316 VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP | JABALPUR | MADHYA PRADESH | 482001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹42.4 L+₹4.2 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
24 Sept 2024, 5:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR/ MAINT TO ROOF SHEETS, FALSE CEILING AND ALLIED WORKS IN THE AOR OF AGE B/R-I UNDER GE (W) JABALPUR
2024_MES_671847_1
8757/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹97,600
19 Nov 2024
4 Sept 2024
30 Sept 2024
5 Sept 2024
24 Sept 2024
17 Sept 2024
5 Sept 2024 - 12 Sept 2024
Amount
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for coving, benching, coping etc at up to four storey including removing of rubbish from the premises complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
Taking Down old roof treatment of any description from roof upto Four storey Building including removing of old plaster, PCC, APP and any other type roof treatment and cleaning of surfaces of old concrete floor/ terrace by picking incl. taking down existing deteriorated / decayed tar felt PCC tiles or any type of treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. complete and removing of rubbish from the premises all as specified and directed.
Removing building materials to a distance exceeding 250 mtr but not exceeding 500 mtr complete all as specified and as directed. Note: Rate quoted by contractor is for inclusive of loading, unloading and stacking/spreading at location as directed by Engineer-in-charge. Nothing will be paid in extra in this regard..
M & L for 25 mm thick PCC 1:2:4 type (B-0) using 12.5 mm graded stone aggregate mixed with water proofing as per manufacturer instructions as in roof padding/ Coving etc upto Four storey building complete all as specified and as directed. .
M & L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping, benching etc upto four storey complete all as specified and as directed. .
M&L for 10 mm thick rendering in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface to maintain the proper slope of roof surface etc upto and including Four Storey complete all as specified and directed.
M&L for Providing water proofing treatment with super thermo APP modified water proofing memberane in roof upto Four Storey building by Apply two coat of Bituminous base Aluminium paint @ 0.20Ltr/Sqm over One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non woven fabric shall be laid in roof surfaces with lap of 100 mm and the over lap shall be sealed by flame laid over one coat of industrial bitumen 85/25 @ 1.20Kg per Sqm over water base bitumenous primer @ 0.40 Ltr/Sqm over cleaned plastered surface complete all as specified and as directed..
M&L for Precast PCC plain factory made tiles, ISI marked, 22 mm thick of size 250 mm x 250 mm, fabricated using grey cement & no pigments laid over 15 mm thick cement mortar (1:3) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces at upto Four storey complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of timber scantlings as in unframed work 40Sq Cm and over in section, in any position complete all as specified and directed.
M&L for Roof trusses (framed), trussed,post,rafters, purlins, tube crane, gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, wind ties etc. conforming Fe 410 -W (GdeE- 250) quality ''A'' complete all as specified and as directed.
M&L for Second class hardwood as in scantlings and clean sawn timber framed and fixed complete all as specified and directed.
Dismantling of Old roof sheet of any description (Asbestos corrugated, semi corrugated,polycarbonate, fibre glass sheet etc) as in roof covering complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering incl ridge complete all as specified and as directed.
M&L for 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws in patches ( Area of patch should not be more than 20.00 Sqm) complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for 0.71 mm Plain, Aluminium sheeting, Alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashing (length andgirth as fixed) complete all as specified and directed.
S&F in repairs 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer as in roof, wall etc complete all as specified and directed.
S&F for 10mm thick Hgh quality Polycarbonate sheet including all fixing arrangements, fixing with mild steel flats, screw fasteners, sticking liquid as per manufacturers instructions etc complete all as specified and directed.
Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed..
M&L for Brick work using old size of fly ash bricks with straight or curved on plan exc 6m mean radius built in cement mortar 1:6 etc complete all as specified and directed.
M&L for 5mm thick cement plaster in cement mortar 1:3 as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) mixed with WPC on brick work or concrete surfaces finished even and smooth without using extra cement in wall, chajjas, partiations complete all as specified and directed. NOTES: 1 WPC shall be measured and paid separately. 2. The rate quoted by contractor shall be inclusive upto G+2 storey buildings.
M&L for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of chalk whitening primer complete all as specified and as directed.
Prepration of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coats of synthetic enamel paint over a coats of a pink primer complete all as specified and directed.
M&L for preparation of new painted surfaces of steel and iron surfaces of any description, over 10cm in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and directed.
Dismantling of wall and ceiling boards of any description any thickness, including cover fillets complete all as specified and as directed.
M & L for 4 mm thick Non asbestos fibre cement building designed boards fixed or laid/ inserted to timber/GI/Aluminium frame work and painted with two coats white distemper oil emulsion complete all as specified and as directed.
Refixing only reusable the ceiling boards retrived from Srl item No 34 above in the position complete all as specified and as directed.
S & F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre and intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre in level and fixed in required position complete all as specified and as directed.
M&L for applying heat reducing Coating as roof treatment after Cleaning of roof slab surface of any height filled all cracks / undulations with cement morter 1:2 mixed with water proofing compound, cured and applying three coats pidilite product Dr fixit roof seal water proofing sealant or equivalent of approved brand complete in all as specified and as directed.
Taking down eaves gutters and rain water pipes (any size or pattern ),including all fittings,heads,shoes,bends,swan necks etc.including cleaning or refixing complete all as specified and as directed.
S&F for 110 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings joints fixed to walls complete all as specified and as directed.
S&F for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F 110 mm dia PVC (SWR ) bends any radius complete all as specified and as directed.
S&F 75 mm dia PVC (SWR ) bends any radius complete all as specified and as directed.
S&F 110 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed.
S&F 75 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed.
S&F 110 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed.
S&F 75 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed.
M&L for disconnecting existing tanks of 250 to 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting as in required position, reconnecting and re-fixing in position complete all as specified and directed
M&L for disconnecting existing tanks of 500 to 1000ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting as in required position, reconnecting and re-fixing in position complete all as specified and directed
S&F in repair for CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors for 20mm bore of pipe jointed with adhesive including Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor and all necessary fittings etc complete all as specified and directed.
S&F in repair for CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors for 25mm bore of pipe including Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor and all necessary fittings etc complete all as specified and directed.
Rai Construction Co (BID ID -3110035)
RP ANAND (BID ID -3108171)
M/s PARASRAM MULCHANDANI (BID ID -3110739)
JAIDEV SINGH CHADHA (BID ID -3108434)
Tiki Water proofing Co (BID ID -3105135)
chandra builders (BID ID -3100861)
Kirti Chandeliya and Assosicates (BID ID -3109893)
a k builders (BID ID -3111165)
Hemant Associate (BID ID -3111274)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3103905)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .