Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | ₹34.8 L Quoted ₹35.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹40.3 L+₹5.3 L (15.1%)Rejected-AOC S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹40.3 L+₹5.3 L (15.1%) | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | OM INFRA L2 | shanti enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Supply, laying, fixing and testing 150 mm dia (wall thickness 5.4 mm) heavy duty MS Pipe conforming to IS: 1239/3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. including welding, cutting, and grinding works, laid in trenches, or fixing in wall, ceiling and floor complete and making good the disturbed surface similar to existing excavation & providing cement concrete blocks as supports, anticorrosive treatment with coal tar/asphalt tape and painting with two or more coats of synthetic enamel paint of post office red colours per IS- 10221, in and including disconnected/ dismantling and taking out of rusty/damaged MS pipes as required complete all as specified and directed. | 12 | RM | 4,500 ₹54,000 | 2,200 ₹26,400 Lowest |
| 2.00 | All as per item No. 1 above but 100 mm. dia (wall thickness 5.4 mm) heavy duty MS Pipe complete all as specified and directed. | 12 | RM | 3,000 ₹36,000 | 2,000 ₹24,000 Lowest |
| 3.00 | All as per item No. 1 above but 80 mm. dia (wall thickness 4.85 mm) heavy duty MS Pipe complete all as specified and directed. | 12 | RM | 2,500 ₹30,000 | 1,800 ₹21,600 Lowest |
| 4.00 | Supply, laying and testing of 50 mm dia medium grade GI Pipe with all fittings laid in trenches/open including taking down old unserviceable pipe complete all as specified and directed. | 12 | RM | 450 ₹5,400 | 400 ₹4,800 Lowest |
| 5.00 | Supply, laying and testing of 80 mm dia medium grade GI Pipe with all fittings laid in trenches/open including taking down old unserviceable pipe complete all as specified and directed. | 6 | RM | 800 ₹4,800 | 700 ₹4,200 Lowest |
| 6.00 | Supply, laying and testing of 100 mm dia medium grade GI Pipe with all fittings laid in trenches/open including taking down old unserviceable pipe complete all as specified and directed. | 6 | RM | 950 ₹5,700 | 900 ₹5,400 Lowest |
| 7.00 | Supplying, fixing and testing in repairs of double flanged butterfly valve of PN 1.6 rating, CI, gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and SS 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of 150 mm dia size including taking down old unserviceable one complete all as specified and directed. | 2 | Each | 10,000 ₹20,000 | 9,000 ₹18,000 Lowest |
| 8.00 | Supplying, fixing and testing in repairs of double flanged butterfly valve of PN 1.6 rating, CI , gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and SS 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of 100 mm dia size including taking down old unserviceable one complete all as specified and directed. | 2 | Each | 8,000 ₹16,000 Lowest | 8,000 ₹16,000 Lowest |
| 9.00 | Supplying, fixing and testing in repairs of double flanged butterfly valve of PN 1.6 rating, CI , gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and SS 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of 80 mm dia size including taking down old unserviceable one complete all as specified and directed. | 2 | Each | 6,000 ₹12,000 | 5,000 ₹10,000 Lowest |
| 10.00 | S&F in repairs Cast Iron Non-return valves, conforming to IS 13095 of size 150 mm dia including taking down old unserviceable one complete all as specified and directed. | 2 | Each | 20,000 ₹40,000 | 18,000 ₹36,000 Lowest |
Tender Value
₹40.0 L
EMD Value
₹79,990
Closing Date
15 Jun 2026, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR/REPLACEMENT MAINT OF FIRE HYDRANT SYSTEM AND CONNECTED WORKS AT TECH AREA AT AFS YELAHANKA
2026_MES_765072_1
8510/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF)Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹79,990
Yes
11 Sept 2026
13 May 2026
22 Jun 2026
13 May 2026
15 Jun 2026
27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, laying, fixing and testing 150 mm dia (wall thickness 5.4 mm) heavy duty MS Pipe conforming to IS: 1239/3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. including welding, cutting, and grinding works, laid in trenches, or fixing in wall, ceiling and floor complete and making good the disturbed surface similar to existing excavation & providing cement concrete blocks as supports, anticorrosive treatment with coal tar/asphalt tape and painting with two or more coats of synthetic enamel paint of post office red colours per IS- 10221, in and including disconnected/ dismantling and taking out of rusty/damaged MS pipes as required complete all as specified and directed. | - | RM | - | - |
| 2 | All as per item No. 1 above but 100 mm. dia (wall thickness 5.4 mm) heavy duty MS Pipe complete all as specified and directed. | - | RM | - | - |
| 3 | All as per item No. 1 above but 80 mm. dia (wall thickness 4.85 mm) heavy duty MS Pipe complete all as specified and directed. | - | RM | - | - |
| 4 | Supply, laying and testing of 50 mm dia medium grade GI Pipe with all fittings laid in trenches/open including taking down old unserviceable pipe complete all as specified and directed. | - | RM | - | - |
| 5 | Supply, laying and testing of 80 mm dia medium grade GI Pipe with all fittings laid in trenches/open including taking down old unserviceable pipe complete all as specified and directed. | - | RM | - | - |
| 6 | Supply, laying and testing of 100 mm dia medium grade GI Pipe with all fittings laid in trenches/open including taking down old unserviceable pipe complete all as specified and directed. | - | RM | - | - |
| 7 | Supplying, fixing and testing in repairs of double flanged butterfly valve of PN 1.6 rating, CI, gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and SS 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of 150 mm dia size including taking down old unserviceable one complete all as specified and directed. | - | Each | - | - |
| 8 | Supplying, fixing and testing in repairs of double flanged butterfly valve of PN 1.6 rating, CI , gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and SS 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of 100 mm dia size including taking down old unserviceable one complete all as specified and directed. | - | Each | - | - |
| 9 | Supplying, fixing and testing in repairs of double flanged butterfly valve of PN 1.6 rating, CI , gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and SS 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of 80 mm dia size including taking down old unserviceable one complete all as specified and directed. | - | Each | - | - |
| 10 | S&F in repairs Cast Iron Non-return valves, conforming to IS 13095 of size 150 mm dia including taking down old unserviceable one complete all as specified and directed. | - | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
8510Merged.pdf
Tender Documents • 1.07 MB
BOQ_856888.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .