Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹41.3 LAccepted-AOC 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE KALIMATA MANDIR ROAD PATHANKOT PUNJAB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹45.7 L+₹2.3 L (5.23%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹47.0 L+₹3.6 L (8.20%)Rejected-Finance MASTER BUILDING DALHOUSIE ROAD DALHOUSIE ROAD PATHANKOT PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹48.1 L+₹4.7 L (10.9%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L-4 | Rejected-Finance Other than Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
REPAIR / MAINT OF HT NETWORK, SWITCHGEARS AND OTHER CONNECTED ITEMS AT AF STATION PATHANKOT
2022_MES_507658_1
CWEAFJ-31/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Pathankot
₹90,000
Yes
1 Apr 2022
12 Feb 2022
14 Mar 2022
12 Feb 2022
12 Mar 2022
26 Feb 2022
60 days
Amount
Disconnecting defective Outdoor / Indoor Transformers of capacity upto 750 KVA from HT/LT side, taking out complete Transformer Oil, storing the same in suitable container (to be arranged by the contractor) opening the top cover and lifting the core assembly by means of tripod and chain pulley block carefully to check its condition, refilling the transformer oil after complete dehydration / filtration if required (to be paid separately) and necessary repairs re-fixing complete core assembly fixing the top cover and complete core assembly fixing the top cover and re-installation complete all as specified and directed.
Notes : 1. In case of Pole mounted Transformer the contractor shall make arrangements for lowering and taking down the same from the Two Pole / Four Pole structure to ground carefully. The quoted rate shall be deemed to be inclusive of this aspect. 2. The Contractor's Mechanic / Skilled Tradesman shall visit the site for first inspection of the Transformer and in case of major Repairs / Replacement in Transformer which can not be undertaken at site the transformer shall be shifted to civil workshop and the cost shall be paid separately under relevant items. 3. Cost of Dehydration / Filtration and other necessary repairs shall be measured and paid separately under the relevant item.
Transporting the defective Transformer for repair from Site to civil workshop and vice versa, Strip opening of Transformer and removing the top cover for repair, taking out the burnt-out core alongwith HT/LT coil (windings) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing the accessories in Transformer body and connecting up, filling in the dehydrated transformer oil and connection with existing electrical system HT/LT and commissioning complete on load of capacity not exceeding 200 KVA complete all as specified and as directed. Note : The Transformer Oil will be measured and paid separately under the respective item.
All as per the description of Serial Item No 2 here-in-before but capacity above 200 KVA and upto 750 KVA complete all as specified and as directed.
Winding of HT / LT coil of different type, capacity and make of transformer with approved quality supper enamelled copper wire / strips of approved make of suitable gauge and number of turns alongwith allied materials like cork sheet, fibre glass insulations, paper insulations, cotton / empire tape and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site and as directed.
All as per the description of Serial Item No 4 here-in-before but with superior quality super enamelled aluminium wire / strips of appropriate gauge and number of turns with allied material all as specified and as directed.
Reconditioning of LT coil of Aluminium / Copper wound Transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed.
Replacement of defective worn out HT Bushing Rod (stud) complete made of copper/brass with nuts and washers oil seal including threading at both ends for HT bushing of Outdoor / Indoor Transformer of various sizes upto 200 KVA as per site requirement complete all as specified and directed.
All as per the description of Serial Item No 7 here-in-before but capacity above 200 KVA and upto 750 KVA complete all as specified and as directed.
Replacement of defective worn out LT Bushing Rod (stud) complete made of copper/brass with nuts and washers oil seal including threading at both ends for HT bushing of Outdoor / Indoor Transformer of various sizes upto 200 KVA as per site requirement complete all as specified and directed.
All as per the description of Serial Item No 9 here-in-before but capacity above 200 KVA and upto 750 KVA complete all as specified and as directed. Makes for Serial Item No '07' to '10 : ABB / SEIMENS / CROMPTON
Silica gel breather assembly complete upto 750 KVA Transformer all as per the sample approved / site requirement fixed in repairs complete all as specified all as directed.
Replacement of silica gel in existing breather assembly up to maximum level of transformer upto 750 KVA complete all as specified and directed by Engr-in-Charge. Note : Replacement of Silica gel in one Transformer will be considered as one Job.
Temperature gauge circular dial type of standard size and dia suitable for Transformer upto 750 KVA, fixed in repairs, complete all as specified and directed. Make : AE / ITE / KIRLOSKAR
Top gasket made of 3mm thick cork sheet with suitable holes for Transformer including providing suitable size of bolts, nuts and washer for transformer top cover fixed in repairs, complete for any capacity upto 200 KVA all as specified.
Top gasket made of 3mm thick cork sheet with suitable holes for transformer including providing suitable size of bolts, nuts and washer for transformer top cover fixed in repairs, complete for any capacity above 200 KVA and upto 750 KVA all as specified.
Supply and top up / refilling of insulating Transformer Oil conforming to IS-335 1993 amended upto date with breaking capacity not less than 45 KV including taking out old unserviceable Oil all as specified and directed. Make : SAVITA / POWERLINK / POWER OIL
Dehydration including filtration and cleaning of Transformer Oil at different locations by stream line method dehydration plant including testing of samples before and after dehydration and filtration. The dielectric strength shall not be less than 45 KV at 2.5 mm gap after dehydration all as directed. Notes : 1. Test results before and after filtration to be recorded as per the sample provided by Engr-in-Charge. 2. The quoted rate is deemed to be inclusive of making necessary connections to Filtration Plant from Transformers and Switchgear Oil duly removing the inlet and outlet connections. 3. For topping up Transformer oil will be measured and paid separately under relevant item of Schedule.
Tapping Switch / Gear changer mechanism for varying HT voltage in steps for Transformer capacity not exceeding 200 KVA fixed in repairs, complete all as specified and as directed.
Tapping Switch / Gear changer mechanism for varying HT voltage in steps for Transformer capacity above 200 KVA upto 750 KVA fixed in repairs, complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Fixing only Steel Tubular swaged Poles type 410 SP-55 (11.0 mtr long), including including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable pole all as specified and as directed. Note : Steel Tubular Swaged Poles shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only Steel Tubular swaged Poles type 410 SP-31 (9.0 mtr long), including including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable pole all as specified and as directed. Note : Steel Tubular Swaged Poles shall be issued 'Free for Fixing' under Schedule 'B'.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) including taking down old unserviceable ACSR conductor all as specified and as directed. Make : JAIPURIA / ALUMINIUM IND / ICC / NICCO / ALIND
Galvanised Guard wire / Cradles / Stay wires complete as required at site including taking down old unserviceable wire all as specified and as directed.
Stay assembly for LT Steel Tubular Poles comprising of 7/10 SWG galvanized MS stranded Stay Wire of required length, minimum tensile strength 70 Kg/Sqmm (grade-2 quality) fixed to pole with and including GI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400 x 14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65 x 90mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6mm including necessary excavation and earth work any type strata PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50 metres all as specified and shown in Plate No 1 of MES SSR Part-I, including taking down old unserviceable Stay assembly complete all as specified and as directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade including taking down old unserviceable insulator complete all as specified and directed.
Shackle type insulator porcelain vitreous white, brown or green including galvanised M.S. straps 31 x 5mm size, 100mm height, 115mm dia including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete including taking up of old unserviceable insulator complete all as specified and directed. Makes for Serial Item No '32' to '35' : BHEL / PACTIL / MYSORE PORCELAINS /JAIPURIA
Switch Air break, gang operated (GOD) with 12 Nos insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 200 Amps complete including taking down old unserviceable GOD any type, all as specified and directed. Make : JAIPURIA / PACTIL / ANDREW YULE / MYSORE ELECTRIC / ABB / UNIVERSAL
Periodical maintenance of Air Break Gang Operated Switches (GOD) capacity 200 Amps fixed on Two Pole / Four Pole structure after taking proper electric shut down with all precaution from MPH tightening of all jumpers, PG clamps, connection after taking proper shut down with all precaution including painting all steel structure by applying two coat of synthetic enamel paint over a coat of primer, greasing and repair male and female contact, wire mesh strip, drop out fuses, locking arrangement by unscrewing nuts, bolts etc. complete all as specified and directed.
Danger Notice Plate, for HT, of size 25cm x 20cm x 1.5mm thick mild steel sheet, vitreous enamelled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, including taking down old unserviceable insulator complete all as specified and directed.
Danger Notice Plate, for LT, of size 20cm x 15cm x 1.5mm thick mild steel sheet, vitreous enamelled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, including taking down old unserviceable Danger Notice Plate complete all as specified and directed.
Lightning Arrestor expulsion type having rated voltage 11 KV and discharge current 65 KA suitable for 11000 Volt with mounted on MS plate 8 mm thick duly painted with aluminum paint bottom of size of lightning arrester including connection with earth strip connecting device including taking down old unserviceable Lightening Arrestor any type, complete all as specified and directed. Make : PACTIL / CROMPTON / ALSTOM / OBLUM / JAIPURIA
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to at least 3.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two adjacent poles.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on HT / LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
Painting of Steel Tubular Pole any type with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Painting of PCC Pole any type with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all exposed surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Spray Painting of LT Three Phase Busbar Chamber of any size fixed on channel with two coats of synthetic enamel paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all exposed surface and marking of MES No complete all as specified and as directed.
Fixing only in repairs 11 KV Moving Contact for GOD complete with all fittings including taking down old unserviceable Contact, complete all as specified and directed. Note : Moving Contact shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only in repairs 11 KV Fixed Contact for GOD complete including taking down old unserviceable Contact, complete all as specified and directed. Note : Fixed Contact shall be issued 'Free for Fixing' under Schedule 'B'.
LT Line Spacers / Separators made of Epoxy / SMC material 1.1 KV grade suitable for holding 02 Lines of ACSR conductor complete all as specified and as directed.
LT Line Spacers / Separators made of Epoxy / SMC material 1.1 KV grade suitable for holding 04 / 06 Lines of ACSR conductor complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 100 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 50 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed. Makes for Serial Item No '52' to '54' : JINDAL PIPES / TATA / BST / PRAKASH SURYA
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 95 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles, fixed in repairs, complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 120 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles, fixed in repairs, complete all as specified and directed. Makes for Serial Item No '55' & '56' : UNIVERSAL CABLES / ASIAN CABLES / KEI INDUSTRIES LTD / FINOLEX / POLYCAB / GLOSTER CABLES LTD / CCI / NICCO / HAVELLS
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 120 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles, fixed in repairs, complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 95 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles, fixed in repairs, complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 50 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles, fixed in repairs, complete all as specified and directed. Makes for Serial Item No '57' to '59' : UNIVERSAL CABLES / KEI INDUSTRIES LTD / FINOLEX / POLYCAB / GLOSTER CABLES LTD / HAVELLS / RPG CABLES
Cable jointing kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, fixed in repairs, complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, fixed in repairs, complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for Indoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, fixed in repairs, complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for Indoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, fixed in repairs, complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for Straight Through Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for Straight Through Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, fixed in repairs, complete all as specified and directed.
Cable jointing kit for 1100 Volts grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10 to 35 Sqmm, fixed in repairs, complete all as specified and directed.
Cable jointing kit for 1100 Volts grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, fixed in repairs, complete all as specified and directed.
Cable jointing kit for 1100 Volts grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to 400 Sqmm, fixed in repairs, complete all as specified and directed. Makes for Serial Item No '60' to '68' : DENSON / M-SEAL / BIRLA 3M / RAYCHEM / CABSEAL
M&L for Calibration of HT VCB indoor type 11 KV with calibration of all protective devices or relay according to load, minor repair to wiring connector block etc. all as specified and directed. Note : 1. Calibration is to be done by authorised service person of OEM. 2. No Extra payment will be made for repeated calibration carried out during the contract period.
Resin encapsulated Vacuum bottles suitable for 11 KV VCB Panel of capacity 400 Amps 18 KA all as specified and directed. Make : ENGLISH ELECTRIC / GE / ABB / SEIMENS
Supplying, installing, testing and commissioning Constant Voltage (CV) Battery Bank (Location at Main Power House and Old Power House) for VCB panel with 12 Nos maintenance free batteries of 2 volts 60 Amps alongwith battery stand and battery charger including initial charging and complete wiring in conduits with HT Panels. The Charger shall be equipped Alarm that will ring on blowing of fuse and in the eventuality of Short Circuit. All the protection to Charger and its Meters shall be provided with rating MCB only. Makes : EXIDE / ANARON / OKAYA / AMCO
Platform for installation of Transformer of size 3000mm x 2500mm x 1200mm with brick construction in cement motor 1:4, PCC 1:3:6 type C-2 in foundation, 100mm thick PCC 1:2:4 type B-1 in floor, Brick Masonry Steps on one side, XPM Jalli fixed on angle iron post of size 50 x 50 x 6mm and Openable type Gate with locking arrangement, earth work in any type of soil including plastering to Brick Masonry work in cement mortar 1:4 and painting to steel surfaces with two coats of synthetic enamel paint over a coat of red-oxide primer and two coats of colour wash over a coat of white wash on plastered surface complete all as specified and as directed.
Repair to HT Panel having VCB (Vacuum Circuit Breaker) 11 KV rating of capacity 250 MVA and current rating up to 800 Amps by replacing defective / worn-out parts, with the same make and capacity adjustment of gaps for smooth operation all as detailed below by Switch Off complete HT/LT electric supply of Sub Station and isolating the HT Vacuum Circuit Breaker 11 KV, Three Phase, 400 Amps capacity by disconnecting all incoming/outgoing HT cable carefully and checking the serviceability of unserviceable VCB step-wise such as primary insulation, secondary insulation, complete wiring system, auxiliary switches tripping system, tripping mechanism, vacuum interrupter, safety shutter, motor charging system / mechanically charging spring, earthing system busbar, insulators current transformer and other related spares such as Over Current and Earth Fault Relays, meters and other control in the presence of AGE E/M complete including cleaning of all spares properly, removing all dust and dirt particles unserviceable spares parts shall be measured and paid for separately under relevant items and refixing the same after repair and testing on full load complete all as specified and directed.
(a) Cleaning of VCB with air blower and removing dust particles. (b) Cleaning of insulating paces of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the acring contact gap of vacuum interrupter and if the gap exceeds the permissible limis, re-adjusting as recommended. (d) Replacing the fixed and moving contact if the thickness of contacts is not proper. (e) Cleaning the main contacts to remove carbon or some unwanted particles if visible. (f) Dismantling and cleaning the insulated surfaces and arc-barrier with CTC and CRC. (g) Checking / Repair / Replacement of all electrical wiring for Electrical / Manual Operation including measuring IR values. (h) Checking of all parts of cradles for proper alignment and greasing etc. (j) Checking of all Nuts / Bolts, Springs, Levers \ Latches connection etc. and adjustment as required and recommended. (k) Recording IR value of CT's, PTs.
(l) Cleaning of Bus Bar spout. (m) Replacement of defective indicator lamps etc. (n) Checking of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Make of VCB : CG / ABB / Alstom / Ariva / Kirloskar. Notes : 1. The servicing shall be carried out through service engineer of manufacturer. 2. No employee of any authorised dealer shall be hired for servicing of VCB. 3. Any major spare part, if required, shall be paid separately under the respective item.
Supply and Fixing in repairs Parts of HT VCB 11 KV, AC Three Phase, 50 Hz Indoor type complete as per existing make all as specified and directed with the following :-
Control wiring of HT VCB panel with suitable size of copper wire complete with colour code ferrules and tinned copper lugs.
Tripping Coil 24 Volts DC.
Bakelite Housing Set.
Spout Set (Set of Three) Shower and Rose Contacts.
Auxiliary Switch.
Limit Switch.
Rotary Switch.
Auxiliary Contactor.
Closing Coil 24 Volts.
Tripping Lever.
Charging Lever.
Changing Gear for VCB.
Neon Indicator LED type Lamp assembly 110 volts DC Make : SEIMENS / L&T/ MEI / LEGRAND
Tripping Pin.
Push Button.
Spring Charging Motor complete 220 Volts.
Ammeter 0-150 Amps CT ratio 150/5 Amps as per sample Make : Dhoot instruments Pvt Ltd.
Voltmeter 0-150 Amps PT ratio 11/24 V as per sample Make : Dhoot instruments Pvt Ltd.
Spray Painting of complete Transformer with two coats of heat resistant weather proof grey synthetic enamel paint after cleaning / removing dust, rust or carbon etc. including writing MES No / SM No complete all as specified and as directed of the following capacities :-
(a) Transformer of capacity 63 KVA to 100KVA
(b) Transformer of capacity 150 KVA to 250 KVA
(c) Transformer of capacity 300 KVA to 750 KVA
MCCB Three Pole, 415 Volt, 400 Amps capacity with rupturing capacity 36 KA with adjustable thermal magnetic trip unit/release with Ics = 100% Icu complete all as specified and as directed.
MCCB Three Pole, 415 Volt, 400 Amps capacity with rupturing capacity 36 KA with adjustable thermal magnetic trip unit/release with Ics = 100% Icu complete all as specified and as directed.
MCCB Three Pole, 415 Volt, 250 Amps capacity with rupturing capacity 36 KA with adjustable thermal magnetic trip unit/release with Ics = 100% Icu complete all as specified and as directed.
MCCB Three Pole, 415 Volt, 200 Amps capacity with rupturing capacity 36 KA with adjustable thermal magnetic trip unit/release with Ics = 100% Icu complete all as specified and as directed.
MCCB Three Pole, 415 Volt, 160 Amps capacity with rupturing capacity 25 KA with adjustable thermal magnetic trip unit/release with Ics = 100% Icu complete all as specified and as directed.
MCCB Three Pole, 415 Volt, 125 Amps capacity with rupturing capacity 16 KA with adjustable thermal magnetic trip unit/release with Ics = 100% Icu complete all as specified and as directed.
MCCB Three Pole, 415 Volt, 63 Amps capacity with rupturing capacity 16 KA with adjustable thermal magnetic trip unit/release with Ics = 100% Icu complete all as specified and as directed. Makes for Serial Item No '76' to '82' : L&T / SCHNEIDER / ABB / SEIMENS / LEGRAND / HAVELLS
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI Strip of size 32 x 6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on Electric Plate No. 03 of SSR-2009 Part-I, complete all as directed.
M/S SHRI RAM BUILDERS
INDIA ELECTRIC WORKS
Vijay Kumar Contractor and Engineers
Bidder Name
Vijay Kumar Contractor and Engineers
INDIA ELECTRIC WORKS
M/S SHRI RAM BUILDERS
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .