Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 CrAdmitted-Finance NAGPUR MAHARASHTRA | NAGPUR | MAHARASHTRA | 440000 | ₹6.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹7.5 CrAdmitted-Finance | ₹7.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹7.6 CrAdmitted-Finance BLOCK NO 758 EAGLE NEST BEHIND CHOPRA COURT ULHASNAGAR 421003 DIST THANE | 421003 | ₹7.6 Cr | L3 | Admitted-Finance |
| 4 | L4₹7.9 CrAdmitted-Finance 286 2 PARAG STATION ROAD BUDHWAR PETH KARAD SATARA | PUNE | MAHARASHTRA | 412206 | ₹7.9 Cr | L4 | Admitted-Finance |
| 5 | L5₹8.1 CrAdmitted-Finance | ₹8.1 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ADARSH INFRAINTERIO PVT LTD L5 | Eagle Infra India Ltd L3 | VIJAY BUILDERS AND CONSTRUCTIONS PVT LTD L1 | Skyway Infraprojects Pvt. Ltd. L6 | Kaishar Interiors Pvt Ltd L7 | SD INTERBUILD (INDIA) PRIVATE LIMITED L2 | SHAH EPC SERVICES AND PROJECTS PVT LTD L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Civil Work | ||||||||||
| 2.00 | Demolishing existing masonry work for all thickness inclusive of RCC Patlis, cutting reinforcement bars etc complete as directed & instructed by Engineer In Charge. Walls denoted in the drawing to be demolished, starting from top and progressively coming down, care to be taken so as not to damage the floor slab, beams, columns, adjacent walls, doors & windows. In any given area, walls to be demolished prior to breaking the existing floor. Demolition of existing wall inclusive of removal of plasters, wall dado, other finishes & cleaning etc. | 260 | Cum | 1,081.2 ₹2.8 L | 1,000 ₹2.6 L | 2,000 ₹5.2 L | 2,400 ₹6.2 L | 2,778 ₹7.2 L | 1,350 ₹3.5 L | 1,500 ₹3.9 L |
| 3.00 | RCC Structure denoted in the drawing to be demolished, starting from top and progressively coming down, care to be taken so as not to damage the floor slab, beams, columns, adjacent walls, doors & windows. In any given area, RCC Structure to be demolished prior to breaking the existing floor. Demolition of existing RCC structure inclusive of removal of reinforced steel, plasters, wall dado, other finishes & cleaning etc. | 10 | Cum | 2,252.5 ₹22,525 | 2,000 ₹20,000 | 2,500 ₹25,000 | 4,500 ₹45,000 | 3,815 ₹38,150 | 2,350 ₹23,500 | 5,000 ₹50,000 |
| 4.00Existing Doors and/or Frames to be dismantled, during the process all require precaution to be taken to salvage the door frames and the same shall be covered and stacked on site at allocated space with no additional cost to it, all safety measure to be followed. Extreme precautions to be taken so as not to damage the adjacent wall & RCC members . Any damages arising out of negligence shall be made good by the Contractor at no extra cost. The material shall be stacked anywhere in ACTREC campus as per the instruction of EIC. | ||||||||||
| 5.00 | Single Leaf - 900/1000/1200 x 2400 | 30 | Nos | 180.2 ₹5,406 | 500 ₹15,000 | 500 ₹15,000 | 1,300.1 ₹39,003 | 1,500 ₹45,000 | 440 ₹13,200 | 400 ₹12,000 |
| 6.00 | Double Leaf -1200/1500/1800/2100 x 2400 | 10 | Nos | 315.35 ₹3,153.50 | 500 ₹5,000 | 600 ₹6,000 | 1,430.11 ₹14,301.10 | 1,800 ₹18,000 | 440 ₹4,400 | 400 ₹4,000 |
| 7.00 | Providing & applying Pest Control & Anti-termite treatment by appointing a specialized agency. All work shall in general be executed as specified in IS : 6313 Part II-1981 & as per approved specification of the agency having special know-how for the job. All necessary work to ensure uniform distribution & proper penetration of treatment of treating solution shall be done according to the instruction of the Engineer. The specialized agency shall give a 10 Years Service Guarantee in writing for the job done. Mode of measurement to be on carpet-area of floor and not the area of surface treated. This includes treatment to floor area, Walls, Soil Surrounding pipes, Waste & Conduits, Expansion Joints, Junction of the Wall & the floor, Timber & Carpentry Works, Gypsum related works, etc all complete as per the instructions of architect. | 2,200 | Sqm | 165 ₹3.6 L | 200 ₹4.4 L | 45 ₹99,000 | 135 ₹3.0 L | 60 ₹1.3 L | 67 ₹1.5 L | 75 ₹1.6 L |
| 8.00 | Providing and Laying in line and level up to specified thickness, Lightweight Aerated Block filling to raise the specified area in steps with Aerated blocks & Cement Mortar in CM 1 : 5 as directed with watering, cleaning, curing and finishing in one level etc Complete.
Up to 300 mm high | 40 | Cum | 9,911 ₹4.0 L | 5,000 ₹2 L | 8,500 ₹3.4 L | 8,450.65 ₹3.4 L | 12,426 ₹5.0 L | 5,850 ₹2.3 L | 6,000 ₹2.4 L |
| 9.00 | Chemical Waterproofing :- Surface Preparation: Cleaning the surfaces with Wire brushing and washing treatment receiving surface area with water, so as to make the surface totally dust free to receive the treatment. Cracks shall be treated by chasing open using electrical cutter machine to form a “V” space groove of approx. 4 to 6 mm wide and 10 to 15 mm deep. The groove shall be cleaned with compressed air and thereafter sealed with polymer modified mortar which shall be admixed with Waterprrofing Compound @ 2kg or equivalent per bag of cement. Apply polyurethane/Silicone sealant to the junction of dry wall and RCC slab to fill the gap.Apply bond breaker strip (100 mm) at the junction of drywall/RCC slab embedded between two coats of waterproof coating. Providing and applying a single component waterbased eco-friendly elastomeric copolymer waterproof liquid membrane of make aprooved by Engineer In Charge having Elongation > 250% as per ASTM 412 and crack bridging ability up to 2mm width as per ASTM C 836 .The system includes self priming coat of 50% dilution with water which should be applied at the rate of 8-10 sq.mt /ltr before application of 2 undiluted of make aprooved by Engineer In Charge, by brush or roller at the rate of 1.1/ Ltr /sq.mt/ in self priming & two coat , to achieve a total DFT of 500 Microns and allow it to dry. The second part consists applying smooth CM 1:3, 15 mm thick plaster on wall admixed with integral waterproofing compound of make aprooved by Engineer In Charge @ 0.2 ltr/bag of cement complete as per manufacture specification. | 248 | Sqm | 675.75 ₹1.7 L | 1,500 ₹3.7 L | 1,300 ₹3.2 L | 1,560.12 ₹3.9 L | 1,500 ₹3.7 L | 1,138 ₹2.8 L | 1,500 ₹3.7 L |
| 10.00 | Providing and making Core cut of 100mm dia in RCC slab of thickness up to 300mm, with core cutting machine inclusive of filling of core with fire retardant sealant of approved make & as per the manufacturer's specification, cleaning etc complete. Note: The contractor should determine the location of beams/post tensioned tendons before carrying out the operation, getting prior approval from the builder/structural consultant and cutting all reinforcement by gas cutting machine or as directed etc. complete.
Core cutting for Slab/Wall. Dia : 150 mm - 300 mm | 10 | Nos. | 1,802 ₹18,020 | 1,000 ₹10,000 | 2,500 ₹25,000 | 2,600.2 ₹26,002 | 11,400 ₹1.1 L | 2,025 ₹20,250 | 5,000 ₹50,000 |
Updated dates
Tender Value
₹7.7 Cr
EMD Value
₹15.4 L
Closing Date
18 Oct 2025, 3:00 pmClosed
Director TMC
Office of Engineering services, Second Floor, Khanolkar Shodhika , ACTREC Kharghar Node, Navi Mumbai - 410210
Execution of Internal Civil and MEP Works on the 1st Floor of Shantilal Shanghvi Paediatric Cancer Center (SSPCC) at ACTREC, Kharghar, Navi Mumbai
2025_TMC_873598_1
ET-48/CIVIL AND MEP WORK SSPCC/2025
Open Tender
Civil Works
365 days
ACTREC, Kharghar
As per Tender Document
2 documents required · 2 mandatory
₹0
₹15.4 L
ACTREC,Kharghar
7 Jan 2026
18 Aug 2025
20 Oct 2025
18 Aug 2025
18 Oct 2025
18 Aug 2025
18 Aug 2025 - 3 Sept 2025
3 Sept 2025
Amount
Civil Work
Demolishing existing masonry work for all thickness inclusive of RCC Patlis, cutting reinforcement bars etc complete as directed & instructed by Engineer In Charge. Walls denoted in the drawing to be demolished, starting from top and progressively coming down, care to be taken so as not to damage the floor slab, beams, columns, adjacent walls, doors & windows. In any given area, walls to be demolished prior to breaking the existing floor. Demolition of existing wall inclusive of removal of plasters, wall dado, other finishes & cleaning etc.
RCC Structure denoted in the drawing to be demolished, starting from top and progressively coming down, care to be taken so as not to damage the floor slab, beams, columns, adjacent walls, doors & windows. In any given area, RCC Structure to be demolished prior to breaking the existing floor. Demolition of existing RCC structure inclusive of removal of reinforced steel, plasters, wall dado, other finishes & cleaning etc.
Existing Doors and/or Frames to be dismantled, during the process all require precaution to be taken to salvage the door frames and the same shall be covered and stacked on site at allocated space with no additional cost to it, all safety measure to be followed. Extreme precautions to be taken so as not to damage the adjacent wall & RCC members . Any damages arising out of negligence shall be made good by the Contractor at no extra cost. The material shall be stacked anywhere in ACTREC campus as per the instruction of EIC.
Single Leaf - 900/1000/1200 x 2400
Double Leaf -1200/1500/1800/2100 x 2400
Providing & applying Pest Control & Anti-termite treatment by appointing a specialized agency. All work shall in general be executed as specified in IS : 6313 Part II-1981 & as per approved specification of the agency having special know-how for the job. All necessary work to ensure uniform distribution & proper penetration of treatment of treating solution shall be done according to the instruction of the Engineer. The specialized agency shall give a 10 Years Service Guarantee in writing for the job done. Mode of measurement to be on carpet-area of floor and not the area of surface treated. This includes treatment to floor area, Walls, Soil Surrounding pipes, Waste & Conduits, Expansion Joints, Junction of the Wall & the floor, Timber & Carpentry Works, Gypsum related works, etc all complete as per the instructions of architect.
Providing and Laying in line and level up to specified thickness, Lightweight Aerated Block filling to raise the specified area in steps with Aerated blocks & Cement Mortar in CM 1 : 5 as directed with watering, cleaning, curing and finishing in one level etc Complete. Up to 300 mm high
Chemical Waterproofing :- Surface Preparation: Cleaning the surfaces with Wire brushing and washing treatment receiving surface area with water, so as to make the surface totally dust free to receive the treatment. Cracks shall be treated by chasing open using electrical cutter machine to form a “V” space groove of approx. 4 to 6 mm wide and 10 to 15 mm deep. The groove shall be cleaned with compressed air and thereafter sealed with polymer modified mortar which shall be admixed with Waterprrofing Compound @ 2kg or equivalent per bag of cement. Apply polyurethane/Silicone sealant to the junction of dry wall and RCC slab to fill the gap.Apply bond breaker strip (100 mm) at the junction of drywall/RCC slab embedded between two coats of waterproof coating. Providing and applying a single component waterbased eco-friendly elastomeric copolymer waterproof liquid membrane of make aprooved by Engineer In Charge having Elongation > 250% as per ASTM 412 and crack bridging ability up to 2mm width as per ASTM C 836 .The system includes self priming coat of 50% dilution with water which should be applied at the rate of 8-10 sq.mt /ltr before application of 2 undiluted of make aprooved by Engineer In Charge, by brush or roller at the rate of 1.1/ Ltr /sq.mt/ in self priming & two coat , to achieve a total DFT of 500 Microns and allow it to dry. The second part consists applying smooth CM 1:3, 15 mm thick plaster on wall admixed with integral waterproofing compound of make aprooved by Engineer In Charge @ 0.2 ltr/bag of cement complete as per manufacture specification.
Providing and making Core cut of 100mm dia in RCC slab of thickness up to 300mm, with core cutting machine inclusive of filling of core with fire retardant sealant of approved make & as per the manufacturer's specification, cleaning etc complete. Note: The contractor should determine the location of beams/post tensioned tendons before carrying out the operation, getting prior approval from the builder/structural consultant and cutting all reinforcement by gas cutting machine or as directed etc. complete. Core cutting for Slab/Wall. Dia : 150 mm - 300 mm
Making openings in existing walls for Cables, Service pipelines, AC ducting etc. without damaging the surroundings and making good the affected areas with smooth plaster in mix proportion 1:4, inclusive of lintel support in Cuddapah stone of thickness 25mm to be provided where ever required. Cost to be inclusive of filling the excess opening with brick bats and finishing the same in smooth plaster in cement mortar 1:4 & applying waterproofing treatment, proper curing, giving supports to walls etc complete & disposal of debris at location off the premises at specified location or as directed by Site -in-charge.
Providing and constructing Aerated Block masonry walls of specified thickness at all required locations and at all heights in cement mortar 1:4, including RCC patli 150 mm thick with nominal reinforcement after every 1000-1200 mm height in foundation/ superstructure including striking joints, raking out joints, watering and scaffolding etc. complete. Aerated blocks shall be first class & of approved make. The item includes making and braking of openings for passage of services and AC ducts by providing adequate lintels and support structure to cater to such openings. All block work shall be in line level and plumb. The adjacent sides on all the edges of the wall shall be cleaned & treated with Hack-Aid-Plast. The item is inclusive of all fittings, fixtures and hardware; tools and tackles; centring & shuttering, scaffolding etc. required to complete the work to the satisfaction of the Engineer in-charge. All thickness from 100mm to 200 mm thick
Providing & applying 12 mm thick cement plaster in single coat in cement mortar 1:4, with clean coarse sand of F.M. 1.5, in line, level and plumb, to receive pop finish in all location including providing and fixing GI chicken mesh (24 gauge) at junction of RC members and masonry wall, scaffolding, curing, GI corner guards, joinery guards, racking / chiselling of concrete surface to maintain line and level, etc. complete. The Plastering works shall generally confirm to IS 1661 ( Part III). 6mm deep groove shall be provided at skirting level. The item is inclusive of all fittings, fixtures and hardware; tools and tackles; centring & shuttering, etc. required to complete the work to the satisfaction of the Engineer in-charge.
Providing & Applying perlite based Gypsum plaster with Bulk density of 650-710 Kg/m3 and finesses of 95% passing through 150 micron like “Gyproc” make One Coat Elite (N2+) or equivalent on wall/RCC & block surfaces (with Trowel Finish on Wall) including ceiling. Rate to include for Surface Preparation, filling cracks in the background if any, surface cleaning/curing (if required) ,applying 12 mm to 15 mm thick Gypsum and finishing in line and level with trowel with neat and smooth surfaces free of undulations, cracks, levelling marks etc or any other deformities arising out of poor workmanship. Rate to include for finishing of Electrical Switch Boxes, light points, fan hook points, DB’s etc. Rate to include for providing & Erecting MS frame scaffolding, as per the directions of Site Engineer.
Providing and constructing RCC patli 150 mm thick with nominal reinforcement for door. raking out joints, watering and scaffolding etc. complete. The item is inclusive of all fittings, fixtures and hardware; tools and tackles; centering & shuttering, scaffolding etc. required to complete the work to the satisfaction of the Engineer in-charge. MS structure support should be considered wherever the opening is exceeding 900 mm.
Providing & laying Glazed vitrified floor tiles of specified size ( thickness to be specified by the manufacturer) with water absorption less than 0.08% & confirm to IS : 15622 of approved make, colour & shade etc. as directed by the Architect / PMC. The tiles to be laid over 20 mm thick bed of CM 1:4, including surface preparation, cement float, providing necessary slopes, cleaning & grouting joints with neat white cement slurry mixed with matching pigments. Proper joints to be maintained as per the site requirements. Size as per the 3d design and recommendation of architect.
Vitrified Tile - 01 (Toilets, water cooler area)- Anti Skid tiles
Vitrified Tile - 02 (Passage, Arrival area and other areas) - Premium Quality
Vitrified Tile - 03 (Nursing station)- Premium Quality
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. - AHU Rooms
Providing and cladding Vitrified tiles for skirting of approved make and sample in pattern as per detailed drawings in cement paste on a backing coat of cement mortar in ratio of 1 : 3. The rate should be inclusive of cleaning joints and grouting them with neat white cement paste with pigmented additives to match shade of the tile. Skirting to be fixed flush with finished surface of wall in line and level and 6 mm wide groove to be made in wall at the junction of skirting and finished surface of wall etc. complete matching to flooring.
Vitrified Tile - 02
Vitrified Tile - 03
Providing & cladding Glazed vitrified tiles (Jointless) of specified size on wall ( thickness to be specified by the manufacturer) with water absorption less than 0.08% & confirm to IS : 15622 of approved make, colour & shade etc. as directed by the Architect / PMC. The tiles to be laid over 20 mm thick bed of CM 1:4, in proper position in proper line & level, including surface preparation, cement float, providing necessary slopes, cleaning & grouting joints with neat white cement slurry mixed with matching pigments. Proper joints to be maintained as per the site requirements. The rate should also be inclusive of applying temporary supports to the cladded stone as directed by site in charge. Size as per the 3d design and recommendation of architect.
Vitrified Tile - 01. (Toilet Area)
Vitrified Tile - 02 (Designer Tile) (IP Room Toilet, Male & Female Toilet, Handwash areas, Coffee area)
Vitrified Tile - 03 (Passage, Staricase wall(1.2m Ht))
Providing and fixing Hand wash counter with top made out of 19 mm thick Granite slab of approved shade laid on 35 mm thick one side polished Cudappah with 25 mm thick bedding of 1 : 4 cement mortar in between, supported on 35mm thick both sides Cudappah verticals with all exposed edges machine cut double machine polished in true plane and level with matching cement paste curing flinishing the joints neat etc. complete including making grooves in walls for fixing and making good the surfaces as directed. Providing, 100mm high front facia and 150mm high band ( splash guard) above the counter top of same shade Granite. All exposed surfaces of platform to be finished in same granite slab. Necessary cut-outs for wash basins to be provided and all cut-outs, exposed edges to be half round bull nosed with mirror polished. Cost to also include making necessary cut-outs for taking pipes through counter top. Only top length one side shall be measured. Vertical length or entire perimeter shall not be measured.
Providing and constructing 600 mm wide & 750 mm high counter with top fabricated from 10 mm thick approved sample of Corian laid on 19 mm thick commercial ply backing with approved industrial glue, supported on 19 mm thick commercial ply verticals. The 50 mm high Corian Band ( Splash Guard) shall be provided above the counter top. Cost to be inclusive of shutters of 19mm thick Commercial ply finished in approved shade of 1.5 mm laminate on all exposed surface and balancing laminate on internal surfaces inclusive of necessary teak wood beading and frame work finished in approved shade of melamine polish to match the shade of the laminate or as directed. Cost to be inclusive of horizontal shelves in 19mm thick commercial ply finished in approved laminate. Hardware to include dead locks with SS finished keyhole, brush SS finish handle, SS tower bolt, magnetic ball catches etc. complete. Only top length one side shall be measured. Vertical length or entire perimeter shall not be measured.
Providing and constructing 600 mm wide & 750 mm high counter with top fabricated from 10 mm thick approved sample of Corian laid on 19 mm thick commercial ply backing with approved industrial glue, supported on 19 mm thick commercial ply verticals. The 50 mm high Corian Band ( Splash Guard) shall be provided above the counter top. The Front facia of counter is cladded with approved shade of tile
Providing & Fixing 19 mm thick gang saw cut mirror polished ( pre polished) machine cut granite strips for ramp of required size of approved shade, colour & texture laid over 20 mm thick base cement mortar 1: 4 ( 1 Cement : 4 Coarse Sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing & polishing to edge to give high gloss finish etc. complete at all levels.
Providing & fixing 600 mm - 900 mm wide ledge in proper line & level, made out of 19 mm thick machine cut & polished granite slab of required size of approved shade, colour & texture laid over 20 mm thick bed of CM 1:4, including surface preparation, cement float, joints treated with white cement mixed with matching pigment, curing, polishing & final cleaning of finished ledge etc. as directed. Rate shall be inclusive of moulding & nosing.
Providing & Fixing 19 mm thick gang saw cut mirror polished ( Pre molded & pre polished) machine cut granite for Jambs of required size of approved shade, colour & texture laid over 20 mm thick base cement mortar 1: 4 ( 1 Cement : 4 Coarse Sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, molding & polishing to edge to give high gloss finish etc. complete at a1l levels. The rate should also be inclusive of applying temporary supports to the jamb stone as directed by site in charge. 150 mm wide Granite Threshold Patti
Structural steel work in single or built up section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Providing and fixing GI frame which includes 48mm studs (0.55mm thick having one flange of 34 mm and another flange of 36 mm made of GI steel) placed at 610 mm c/c vertically, in 50mm thick floor and RCC ceiling channel (0.55mm thick having equal flanges of 32mm made of GI steel). Rate shall be also inclusive of 48mm studs horizontal @ skirting level, 1200mm & 2400mm level from floor level reinforced with seasoned Sal wood. Structural Steel support to be provided as required. with 48mm Studs
FIRST SKIN OF PARTITION : Providing and fixing Skin of Standard Plasterboard (Conforming to IS 2095 Part 1 & BSEN 520) having density of >570 kg/cum, screw fixed vertically on either side of existing framework studs with 25mm long Drywall Screws at 300mm centres. The screw fixing of the Standard Plasterboard to the metal framing at the periphery, openings and cut edges should be at 150mm centres. The horizontal & vertical joints of the Standard Plasterboard on both sides of the metal framework must be staggered to avoid through and through joints. All joints to be taped & finished with 50mm wide Paper tape & All-Purpose Joint compound (Confirming to ASTM C475). Necessary cut-outs shall be provided for taking of supply and return air ducts/openings which shall be neatly finished after fixing of ducts thereby leaving no gaps. The layer should be finished so as to take on second skin in Gyp/Ply/MDF or Paint/wall paper directly. (Mode of measurement - Length x height).
Providing and filling 50mm thk rock wool insulation of density as follows of approved make, wrapped in RP tissue Paper enclosed Bags ( 600 mm X 600 mm ) and completely sealed from all sides, as per manufacturer's specifications with necessary frame work supports etc. complete in between the solid partitions for sound insulation from bottom of partition to the slab level of the partition. The GI framework is included in the rate and No extra cost for the same shall be entertained later. Structural Steel support to be provided as required. 48 Kg/ M3
Providing and fixing Skin of Standard Plasterboard (Conforming to IS 2095 Part 1 & BSEN 520) having density of >570 kg/cum, screw fixed vertically on either side of existing framework studs with 25mm long Drywall Screws at 300mm centres. The screw fixing of the Standard Plasterboard to the metal framing at the periphery, openings and cut edges should be at 150mm centres. The horizontal & vertical joints of the Standard Plasterboard on both sides of the metal framework must be staggered to avoid through and through joints. All joints to be taped & finished with 50mm wide Paper tape & All-Purpose Joint compound (Confirming to ASTM C475). Necessary cut-outs shall be provided for taking of supply and return air ducts/openings which shall be neatly finished after fixing of ducts thereby leaving no gaps. The layer should be finished so as to take on second skin in Gyp/Ply/MDF or Paint/wall paper directly. (Mode of measurement - Length x height). The partition should be finished so as to take on wall paper/paint directly by applying suitable base coats, primer coats, etc. complete. Necessary cut-outs shall be provided for taking of supply and return air ducts/openings which shall be neatly finished after fixing of ducts thereby leaving no gaps. Rate should be including cost of grooves mentioned in detailed drawing.
Providing and fixing Aluminium frame includes box section of sizes - 50mm x 25mm x 1.62mm (thickness) forming a grid of not more than 600mm c/c both directions. Rate shall be inclusive of Double Skin tapered edge 12.5mm thick Gyp board (conforming to IS 2095-1982 & 2542-1981) screw fixed with 25mm dry wall screw at 300mm c/c to both sides of existing framework studs. Necessary cut-outs shall be provided for taking of supply and return air ducts/openings which shall be neatly finished after fixing of ducts thereby leaving no gaps. All complete as per manufacturer's specification & instruction of Engineer In Charge. Cost inclusive of 100 to 150mm wide 19mm thk. MDF with 6mm groove for installation of glass partition
Providing and fixing of 132mm thick Drywall system (tested for fire rating of 120 mins.) which includes fixing of Floor & Ceiling channel (0.55 mm thick, 72mm wide & having two flanges of 30 mm each) to the RCC Floor and Ceiling Slab with 8mm Dia 40mm long Anchor Fasteners @ 600 mm c/c respectively. The Wall Studs (0.55 mm thick, 70 mm wide having one flange of 34mm another of 36 mm) are placed at maximum distance of 610mm c/c in Floor and Ceiling channel. These Sections/profiles are rolled with GI Steel (120 GSM & 230 MPa Yield Strength) conforming to IS 277. Provide 99x9x2500x0.90 mm Fixing channel Behind Horizontal Board Joints. 50mm thick @48 kg/cum density Rockwool Insulation shall be provided in the cavity with the help of insulation hold strap fixed @1200mm c/c. Then two layers of 15mm Fire resistant gypsum Plasterboard having density of >880 kg/cum is screw fixed on either side of metal system using Self tapping 3.5x25/38mm drywall screws spaced at 150mm centres on all joints and 300mm centres in the field of plasterboards. Screw fixing is done mechanically. The horizontal & vertical joints of the Gypsum Plasterboard on both sides of the metal framework must be staggered to avoid through and through joints. All joints to be taped & finished with 50mm wide Paper tape & All-Purpose Joint compound (Confirming to ASTM C475). All perimeters and penetrations to be sealed with Fire & Acoustic sealant along with baker rod as per manufacturer’s specifications. All the material should be used as per manufacturer's specifications as per their fire resistant tested assemblies.
2 hours fire rated glazed Door system with 14 mm thick EW category fire rated glass with 2 hours fire rated framing system- : Providing and fixing of tested fully glazed steel fire rated double leaf door with 120 minutes of integrity and radiation control (EW 120) fabricated with 1.6 mm thick galvanized steel sheet. The door frames are manufactured from 1.6 mm galvanized steel sheet pressed to form a profile of 35 mm x 60 mm on the vertical sides and 50 x 60 mm on the horizontal side. The door shutter would have a top rail and side rail 60 mm x 60 mm and a bottom rail of 110 mm x 60 mm. The sections have a special insulating infill. The overall door opening is 2600 mm x 2600 mm. The test is conducted in IFTS as per EN 1634-1: 1999. The glass should be Contraflam Lite, 14mm clear 120 min fire rated (EW 120) Non Wired Toughened Interlayered glass with a light transmission of 86% and a sound reduction of 37 dB and manufactured in UL & TUV audited Facility and including UL-EU Certification. The glass should be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be held in its place with the help of 1.6 mm GI beading and a special ceramic tape with cross section of 5 x 20 mm as per the test evidence. The maximum glazing size should be not more than 1250 mm x 2840 mm (w x h) or 3.55 sq mt in total area which should be clearly mentioned in the test certificate.
The shutters should be fixed to the frame using Dorma SS Ball Bearing Hinges of size 100 mm x 89 mm and 3 mm thickness or equivalent. Beading should be attached using 4 mm x 35 mm SS screws at a distance of 75 mm from the edges and 150 mm c/c henceforth. The door should be fitted with Dorma Mortise Sash lock 952F and door closer TS 83 of Dorma make or equivalent. The inactive leaf should be fixed to the frame using 1200mm long Dorma tower bolt no 9114306 or equivalent.
Providing and fixing of 132mm thick Drywall system (tested for fire rating of 120 mins.) with MS frame work 50mm thick @48 kg/cum density Rockwool Insulation shall be provided in the cavity with the help of insulation hold strap fixed @1200mm c/c. Then two layers of 15mm Fire resistant gypsum Plasterboard having density of >880 kg/cum is screw fixed on either side of metal system using Self tapping 3.5x25/38mm drywall screws spaced at 150mm centres on all joints and 300mm centres in the field of plasterboards. Screw fixing is done mechanically. The horizontal & vertical joints of the Gypsum Plasterboard on both sides of the metal framework must be staggered to avoid through and through joints. All joints to be taped & finished with 50mm wide Paper tape & All-Purpose Joint compound (Confirming to ASTM C475). All perimeters and penetrations to be sealed with Fire & Acoustic sealant along with baker rod as per manufacturer’s specifications. All the material should be used as per manufacturer's specifications as per their fire resistant tested assemblies.
Providing and fixing Single Glazed System ( ARCHITECT /CLIENT HAS A RIGHT TO CHOOSE ANY ONE MAKE AS PER MOCK UP PERFOMANCE ): Supply and installation of Single glazed mullion free demountable glass partition using 10mm/12mm toughened glass in proprietary SAA approved anodised aluminium sections or polyester powder coated of size upto 45 mm x 25 mm as per architect’s approval with acoustic rating of Rw35 db (STC 30DB) with third party test certificate. Rate to include required accessories as per the manufacturer’s specifications and shall be inclusive of all accessories like dry gasket in clear transparent color and removable clip in finished aluminium beads on each side at base track. Glass to Glass joint should be with "I" Section in clear flush polycarbonate finish of 3mm ghost joint. Partition height: Maximum 2700mm. System thickness: All aluminium sections shall be anodised to colour chosen by architect to a thickness of 30 microns
Providing and fixing Skin of Standard Plasterboard (Conforming to IS 2095 Part 1 & BSEN 520) having density of >570 kg/cum, screw fixed vertically on either side of existing framework studs with 25mm long Drywall Screws at 300mm centres. The screw fixing of the Standard Plasterboard to the metal framing at the periphery, openings and cut edges should be at 150mm centres. The horizontal & vertical joints of the Standard Plasterboard on both sides of the metal framework must be staggered to avoid through and through joints. All joints to be taped & finished with 50mm wide Paper tape & All-Purpose Joint compound (Confirming to ASTM C475). Necessary cut-outs shall be provided for taking of supply and return air ducts/openings which shall be neatly finished after fixing of ducts thereby leaving no gaps. The layer should be finished so as to take on second skin in Gyp/Ply/MDF or Paint/wall paper directly. (Mode of measurement - Length x height).
The surface should be finished so as to take on wall paper/paint directly by applying suitable base coats, prime coats, etc. complete. Necessary cut-outs shall be provided for M&E services which shall be neatly finished leaving no gaps. Rate should be including cost of groove mentioned in detailed drawing.
Providing and fixing Second Skin of MDF which includes of desired thick exterior grade MDF screw fixed with wooden screws to Existing first skin of Partition. Care should be taken that the joint should be staggered to avoid leakage. The second layer of MDF shall be stopped 75mm above false ceiling in that area. The partition should be finished so as to take on wall paper/paint directly by applying suitable base coats, primer coats, etc. complete. Necessary cut-outs shall be provided for taking of supply and return air ducts/openings which shall be neatly finished after fixing of ducts thereby leaving no gaps. Rate should be including cost of grooves mentioned in detailed drawing. (Mode of measurement - Length x height up to false ceiling).
18 mm thick MDF
Providing and fixing Finishing Skin of laminate cladded to Existing skin of Partition. The ply to be pasted with approved shade and sample 1.5mm thick laminate. Mode of measurement to be actual Laminate area.
Providing and fixing of 6 mm thick annealed SGG Planilaque Evolution (premium GRIHA rated lacquered glass from Saint-Gobain) or equivalent manufactured industrially by curtain coating process with PU lacquer (50 micron thick), conforming to EN 16477 standards for back painted glass , of approved color by Architect/ Client fixed with compatible SGG Glassmate Ultrafix or equivalent - Neutral Alkoxy based Silicone having Shear Bond Strength (Dry, 24 hours), greater than 450 kpa and tack free time of 10 to 30 mins compatible for installation of mirror and lacquered glass / SGG Glassmate Mirror mounting tape MIRROR MOUNTING TAPE - 1.5mm(thk) / 2mm(thk) Double Adhesive VLC Ultra High Performance (UHP) Adhesive tape of 3M Tapes for instantaneous adhesion, compatible with mirror and lacquered glass having Shear bond strength (Dry, 15 mins) of 250 to 350 kpa) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure. The contractor should submit test reports for backpainted glass from manufacturer - High humidity Resistance (conforms to BS EN 1036 1999); Color fastness ISO 105B02 standard & Mechanical Resistance ISO 7784 ( Taber Abrasion test ) ISO 2409 ( Cross Hatch Test ) standard The manufactured backpainted glass should be environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strenght (1000 MPa) & tensile strenght (40 MPa),same as float glass
P/F MDF based fluted panel of approved make of size 2400 mm Htx width 120 mm and thickness 18 mm. Necessary cut-outs shall be provided for taking of switchess thereby leaving no gaps
Providing & fixing Mirror panelling using 6mm thick mirrior of approved make cut in required sizes, with edges machine polished / bevelled. The mirrior to be fixed on a backing of 12 mm thick commercial plywood stuck to the wall / partition by means of SS Studs with necessary supports in the partition etc. all complete.
Providing and fixing pelmets of size 200mm x 300mm, with verticals upto 1mtr. high & made of 19mm thk pre- lam board along walls and partitions , or glazing with necessary aluminium support. The rate to be inclusive of all accessories, such as anchor fasteners etc. complete. The cost should include prelam vertical upto 1 mm high on one side and 12.5 mm gypsum with paint finish on the other side. Kindly note if framework ht. for fixing pelmet is more than 500 mm then paint finished MS Frame work to be used.
Providing & fixing up to 125 mm wide Ledge made out of 6 mm thick. Commercial ply finished with 12 mm thk. Corian of approved colour & shade. Corner & edges shall be polished. Rate shall be inclusive of fittings, fixtures and hardware; tools and tackles etc. required to complete the work to the satisfaction of the Engineer in-charge.
Providing and fixing approved make PVC Sliding type trap doors .The frame is made from 19mm ply by cutting slats of width 10cms as per the manufacturer instructions. The frame is fabricated using vertical and horizontal member. The vertical member is cut in “L” shape Trap door is cut to form a carpet and grip section with slider. Spiral track and surface track is screwed to the frame. The carpet is rolled and inserted in the track by widening the gap between the two sides. The gap can be widened by inserting the wooden piece slightly larger than internal width.For stability, the lateral movement of frame is restricted by providing cross support at all the four corners and in the middle section.Frame to be hung from ceiling upside down with supports made in “T” shape.The cross support and support provided at middle is nailed to the frame.The trap doors shall be installed as per the manufacturer specifications and instrcutions with beading etc complete.
Size: 300 mm x 300 mm
Size: 450 mm x 450 mm
Providing and supplying fixing seating of size as er requirement (L) x 650mm (D) x upto 500mm Ht made out 50mm x 50mm Aluminum frame work cladded with 19mm thk commercial ply boxing part in the bottom of the seat and Side exposed to be finish with Approved shade laminate the seat of the unit to be finish with 100mm thk Cusion cladded in required slope with Artifical leather / fabric of approved shade. Vendor need to consider all required necessary fittings Hardware ,Adhesive all Complete as per Architect and PMC's Instruction. Mode of measurment running length of the seating
Providing & fixing a portal of 150mm wide and depth as per requirement made of 18mm thk commercial ply & necessary framework for portal, finished with 1.5 mm thk Laminate of approved shade and colour on all external / visible surface etc. as directed by the Architect / PMC. The Laminate to be fixed on proper position in proper line & level with help of Appd. adhesive which including surface preparation & cleaning. The rate should also be inclusive of applying temporary supports to the cladded laminate as directed by site in charge. All complete as per detail dwg. approval of designer & instruction of Engineer In Charge.
Providing & fixing a portal of 150mm wide and depth as per requirement made of 18mm thk commercial ply & necessary framework for portal, finished with 1.5 mm thk Laminate of approved shade and colour on all external / visible surface etc. as directed by the Architect / PMC. The Laminate to be fixed on proper position in proper line & level with help of Appd. adhesive which including surface preparation & cleaning. The rate should also be inclusive of applying temporary supports to the cladded laminate as directed by site in charge. All complete as per detail dwg. approval of designer & instruction of Engineer In Charge.
Providing & constructing laminate finished storage of width 450 mm to 600 mm & size as mentioned below, with top, sides & bottom in 18 mm thick commercial ply, back in 8 mm thick commercial ply, intermediates in 18 mm thick commercial ply @ 375 m c/c, shutters with framework as per drawings in 18 mm thick commercial ply. All external surfaces to be finished in approved 1.5 mm thick laminate, with balancing laminate on the interior surface. All exposed edges to be finished in approved PVC edge binding. Rate shall be inclusive of hardware such as locks, auto closing hinges for shutters, handles, door stopper, Tower bolt, SS key holes of approved make etc all complete.
Full Height Storage : Height : 2100 mm / 2400 mm, Width : 450 mm / 600mm
For Toy Storage
For Dustbin Storage
Providing and fixing DB shutters with top & sides in 19mm thick commercial plywood and finished in approved 1.5mm thick laminate from all exposed sides and 1mm thick balancing laminate on the inner side. The shutters to be in 25mm thick commercial grade block board finished in approved shade 1.5mm thick laminate with appropriate beading and framework made in seasoned teak wood of section 50mmX 75mm, finished in colour polish matching the colour of the laminate. Rate to be inclusive of providing and fixing of Aluminium Grill of size 250 x 75mm (on each shutter) for ventilation, finished in approved shade powder coating, approved SS handle, tower bolts, Locks, magnetic ball-catch, hinges, SS keyhole etc complete as directed.
Providing and fixing Metal Locker units of size 315mm length x 300 mm height x 300mm depth (clear) along with provision for shoe tray where each and every component to be made from CRCA, given through 7 step Anti rust treatment and approved shade powder coating, concealed flush type handle with inbuilt locking facility and provision for indexing and numbering.
Providing and fixing in position Working counter – 600mm deep made out of 19mm thick.commercial grade plywood for top, bottom, sides, intermediate verticals, shutters, shelves etc. with necessary wooden members supports. A well seasoned teakwood trim of section 38mm x 25mm finished with matching colour melamine polish to be fixed on edge of counter top. All external surfaces to be finished in 1.5mm thick. approved shade laminate with balancing laminate on the inner side. All exposed edges shall be covered with matching wooden trim / lipping polished with matching shade.
Fixed drawer pedestal shall be provided with 3 nos. of drawers. Height of each drawers shall be as per drawing / instruction of designers. Drawer shall consist of 12mm thick. commercial plywood sides & back, 9mm thick commercial plywood for base while facia shall be of 19mm thick. commercial plywood finished in approved laminate. Approved shutter profile with multi drawer lock for all the drawers shall be provided. Each drawer shall slide on a pair of telescopic drawer sliders including Readymade metal keyboard tray - 1 no. Counter top shall be provided with matching powder coated metal wire manager at the given location. The drawer unit shall be finished with 1.5mm thick approved shade laminate on all exposed sides and 1mm thick laminate internally.
Supply of Non Wired Toughened Fire Resistant Glass- Required to open on both side (inside & outside) Type - EW Class (EW120). 2 Hr Fire Rated Glass.Contraflam Door Lite - 11 mm Thick. Lock etc all complete as per approved sample & as per detailed drawings & instruction of Engineer In Charges.Size : 1500mm X 2400mm
Supply of Non Wired Toughened Fire Resistant Glass- Required to open on both side (inside & outside) Type - EW Class (EW120). 2 Hr Fire Rated Glass.Contraflam Door Lite - 11 mm Thick. Lock etc all complete as per approved sample & as per detailed drawings & instruction of Engineer In Charges.Size : 2400mm X 2400mm
Supply of single glazed stiled glass door with GI Frame.Type - EW Class (EW120). 2 Hr Fire Rated Glass. Contraflam Door Lite - 11 mm Thick Lock etc all complete as per approved sample & as per detailed drawings & instruction of Engineer In Charges.
Size : 1050mm X 2350/2400mm (D3)- Preconsultation, Consulting, admin
Size : 1800mm X 2350/2400mm (D5) -Admin, Coffee Shop
Size : 1500mm X 2350/2400mm (D4) - Waiting
Providing and fixing single leaf 35 mm thick solid flush door finished with 1.5mm thk approved shade laminate on both sides, mounted on approved make fittings as mentioned below,Door to be mounted on pproved make floor spring / Concealed Door closer. Hinges - 4 Nos per shutter, Handle, Floor mounted Door Stoper, Lock, Door frame specs as per specfied in general note no etc all complete as per approved sample & as per detailed drawings & instruction of Engineer In Charges.
Size : 1200mm X 2400mm (single leaf) (D2A) - Toilet etc
Size : 1050 mm X 2400mm with Vision Panel (D1) - Consultant, Injection, Nurse, Counselling, Joint Clinic etc
Size : 1200mm X 2400mm (single leaf) (D2) - Dietician, Blood Sample, Admin, CTU, Medical Social etc
Providing and fixing single leaf Metal Fire Doors of approved make with a vision panel 310mm X 310mm & without panic bar (For Fire Exit) of 60 minutes Rated Insulated Fire Door Tested in accordance to BS: 476 Part – 20 and IS: 3809: 1979, CNP – 2150Door Frame: Providing of Door Frame of section 120mm X 70mm with fire intumescent seal strip of size 10mm X 4mm for fire and smoke sealing mounted in the grooves of the frame and coated with fire retardant intumescent Primer coating. Hinges: Providing of ball bearing hinges of approved size with S.S. Screws - 4 nos per shutter. Door Closer: Door Closer to be of fire rated of approved make. Handle: Fire rated approved Make & size handles in SS finish to be included in cost.
Size : 900mm X 2350/2400mm (Single leaf) FD3 - IT rack, Electrical, LV Shaft
Size : 900mm X 2350/2400mm (Double leaf)
Size : 900mm X 2100mm (Single leaf) (FD7)
Providing and fixing double leaf Metal Fire Doors of approved make with a vision panel 310mm X 310mm & without panic bar (For Fire Exit) of 60 minutes Rated Insulated Fire Door Tested in accordance to BS: 476 Part – 20 and IS: 3809: 1979, CNP – 2150Door Frame: Providing of Door Frame of section 120mm X 70mm with fire intumescent seal strip of size 10mm X 4mm for fire and smoke sealing mounted in the grooves of the frame and coated with fire retardant intumescent Primer coating. Hinges: Providing of ball bearing hinges of approved size with S.S. Screws - 4 nos per shutter. Door Closer: Door Closer to be of fire rated of approved make. Handle: Fire rated approved Make & size handles in SS finish to be included in cost.
Size : 1500mm X 2350/2400mm (FD4) - Staicase
Size : 1800mm X 2350/2400mm (FD5) - AHU
Providing and fixing a table manufactured as mentioned below.
At most top & working top shall consist of 19mm thick. + 9mm thick. commercial plywood finished with approved shade of Corian. Top as per design shall supported on 35mm thick. plywood verticals finished with approved shade of corian.
Front apron to be made out of 19mm thick. + 9mm thick. commercial plywood finished with approved shade Corian along with neatly prepared 10mm thick polished grooves & 50 mm wide bottom skirting as mentioned in detailed drawing.
Desk should consists of CPU space, shelf to place monitor as per finishes mentioned in drawing & readymade metal keyboard trays - 3 nos.
All exterior surfaces shall be finished with approved shade of Corian & inner surface with matching shade 1mm thick laminate.
All exposed edges shall be covered with matching wooden trim / lipping polished with matching shade.
Fixed drawer units (2 Nos.) shall be provided with 3 nos. of drawers. Height of each drawers shall be as per drawing / instruction of designers. Drawer shall consist of 12mm thick. commercial plywood sides & back, 9mm thick commercial plywood for base while facia shall be of 19mm thick. commercial plywood finished in approved veneer & melamine polish. Each drawer shall have approved brushed S.S finish profile of approved make handle along with multi drawer lock. Each drawer shall slide on a pair of telescopic drawer sliders. Desk top shall be provided with matching powder coated metal wire manager at the given location. The drawer unit shall be finished with approved melamine polish finished veneer on all exposed sides and with matching laminate of approved shade internally. The other Drawer unit (1 No.) should be movable supported on approved make.
Providing and applying Plaster of Paris punning (Anhydrous Gypsum) up to 12-15mm thick over the newly/ existing plastered surface or wherever specified to prepare the surface even and smooth including all leads and lifts, Edge protection for corners etc complete as directed by the Engineer In Charge. Rate to be inclusive of surface preparation by hacking, sand papering & applying a coat of cement slurry (if required) including all incidentals.The rate shall be inclusive of making 6 mm groove as per design requirements.For punning thickness more than 12mm, chicken/PVC mesh (inclusive in rate) to be used. The surface punned to be kept ready to take on paint/wall paper. All complete as per instruction of Engineer In Charges.
Providing and spreading the Bubble Guard Sheets of approved make on the floor to be protected The size of sheet 6' X 4' , D – 8 ( i.e. 8 mm Diameter Bubbles ) & Grammages : 250 gsm. The rate shall be inclusive of removing bubble guard sheets on completion of other works to expose the flooring.
Providing & Fixing approved make Cement Board ceiling using hot dipped galvanised steel section, exposed surface with pre coated capping, main Tee of size 15 x 32mm at every 1200mm. C/c maximum & rotary stitched cross Tee of size 15 x 32mm at every 600 C/c & sub cross Tee of size 15 x 32mm at 1200mm c/c & Wall Angle of size 19 x 19mm fixed to the periphery of the wall. The above grid is suspended at every 1200mm c/c in both direction using butterfly clip with 4mm thick MS rod. All Sides Micro Tegular silhouette reveal profile grid system shall be provided.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in plain/perforated Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
INSTALLATION (Suspension System): To comprise Intermediate channel of size 45mm x 0.55mm thick with two flanges of 15mm each suspended at 1200 mm clipped to spring runner 30mmx0.5mm thick in triangle shape spaced 600 mm, centres along with the runner ,bracket and connectors for spring runners securely fixed to structure using GI soffit cleats fixed to ceiling with 6mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized level clips spaced at 1200 mm centre along with the runner by approved suspension and bracket and connectors for spring runners. Wall angle 19x22 with clips to be secured to the wall at 450 mm maximum centres.
Supply and Installation of 12 mm thk Pet panels sspended from true ceiling shaped as mentioned below. The composition is 100% PET, minimum 50% recycled PET with LOW VOC and green tag
Rectangular 1350mm length Cloundshape
Rectangular 1200mm dia circle
Providing and fixing Metal ceiling in wooden finish - Panelized Torsion Spring smooth texture with framework in 50mm x 25mm x 1.62mm thick. aluminium box section framework @ 600mm c/c both ways suspended from RCC slab. Rate to be inclusive of all kinds of profiles and cut outs required for light fixtures, Speakers, Smoke detector, trap doors and AC grill in the ceiling. All complete as per detailed drawing / instruction of Architect / Engineer In Charge. 24" x 96" panels or as decided by architect/EIC with multiple linear planks in varying heights and widths with planks per panel configurations. Fixing mechanism as per the manufacturers specification and manual. All accessories required shall be provided and procured from the manufacturers. No third party material is permitted unless specified and instructed by Engineer incharge.
Providing and fixing fameline U Baffle Aluminium panel ceiling manufactured by Approved Supplier in approved wooden colour consisting of panel size 25 mm width X 100 mm deep & Gap between two baffle is 75mm clear with using 0.6 mm thick, panel length upto 5 mtr, Coil Coated on a fully automatic powder coating line, and roll formed from enamelled corrosion resistance Aluminium alloy (Al. Mg) for higher strength and good roll forming characteristics. Panels shall be clipped to a G.I slotted angle 2 mm thick, Wooden Colour coated, one leg of the carriers with cut outs to hold the panels in a module of 150 mm. Panel carrier shall be suspended by means of threaded rod at a distance of 1.2 mtr c/c. (Actual distance of threaded rod/carrier to be calculated based on the actual drawing). The gap between two baffle C/C 150mm. The rate inclusive of Labour, tools, related hardware & supervision etc all complete.
Providing and fixing axiom / end Profile in USG / Armstrong or equivalent make with necessary suspension system as per the manufacturer's specification.
100 mm High
Providing and applying three coats of Lustre Emulsion paint of specified make to all internal walls/ceilings, of approved color over a coat of primer including preparation of surface by thorough cleaning and wetting and applying ready made putty 2mm thick of Aprroved make or equivalent as per manufacturer specification fully to give a smooth and even surface before painting and curing as per specifications to the entire satisfaction of Engineer In charge. Rate including all leads and lifts, shifting, scaffolding etc. complete for all heights & levels. The paint shall be anti-bacterial & anti-fungal, fully washable.
Providing and applying Primer, of approved or equivalent make on internal wall / Partition surfaces, wherever required at all heights to give an even and uniform level, after thoroughly sand papering existing surfaces to remove dust, dirt etc. and repairing dents, cracks, holes with POP to achieve level surface and applied over a coat of primer and putty of approved make and equivalent as per manufacturer specification fully to give a smooth and even surface including thoroughly brushing the surface free from water / mortar dropping and other foreign matter and sand papered smooth, complete per manufacturers specifications and as directed.
Providing and applying three coats of Synthetic Enamel Paint of approved manufacturer and of required shade on surfaces to give an even shade including two coats of anti-corrosive Metal primer on ferrous surfaces of approved make as per manufacturer's specification to give a smooth surface including thoroughly brushing the surface free from water / mortar dropping and other foreign matter and sand papered smooth all materials and labour complete.
Providing and fixing Frosted film of approved make on Glass Partition in pattern as per drawings as per manufacturer's specifications etc. complete.Rate of film shall be inclusive of submission Parent company warranty of 10 years for film installed on site. All complete as per manufactures specification & instruction of Engineer In Charge.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete
Providing and fixing white orissa pan (Indian WC) of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor/ Presmatic Push Cock operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specificatio and as per direction as well as approval of Engineer-in-charge.
Providing & Fixing in position Under counter Wash basins including waste coupling all necessary plumbing fixtures.
Providing Health Faucet in W.C.
Providing & Fixing in position 2 in 1 Angle Cock .
Providing & Fixing in position U Shaped Bottle Trap.
Providing & Fixing in position Basin Tap/long neck pillar cock without sensor.
Providing & Fixing in position Waste Coupling .
Providing & Fixing in position Nahni Trap.
Providing & Fixing Hand Dryer in W. C.
Providing Toilet Paper Holders in W.C.
Providing Soap Dispensers.
Providing and fixing Swing Handicap Grab Bar-S.Steel Code No EGR S02,Swing
Providing & Fixing in position Robe Hooks.
Providing & Fixing in position Towel Rod
Providing and fixing in position CPVC pipes conforming to IS: 15778:2007 (Grade SDR-11) with all fittings, brass threaded adaptors and specials, solvent cement/threaded jointing, effecting proper connections, cutting chases in walls and floors and making good (including making connection with existing pipework), Note: Pipe work in shafts, ceiling voids and terrace shall be supported/ fixed on MS structural supports with U-clamps complete with nuts and washers.Cost for MS structural work for supports shall be included in the rates all complete. ( Pipework inside the toilets and pantry etc),pipes confirming to ASTM standards with necessary fittings, and above 50mm dia pipe fitting shall be schedule 40 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge.Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 (internal piping) Note : 1) Solvent Cement shall be of make and grade as specified by the manufacturer of CPVC piping system. 2) The entire CPVC piping system shall be installed, tested and commissioned following the recommendation of the manufacturer.
1" C class pipe with bends
1.5" C class pipe with bends
2" C class pipe with bends
Supplying, and fixing, GM ball valves conforming to IS 1703 with necessary connecting fittings like flanges, nuts and bolts etc., complete.
25 mm dia (Screwed ends)
Supply and fixing, of PVC soil, waste and vent pipes (SWR) confirming to IS13592 : 1990, type B with rubber ring (confirming to IS 5382) 6kg/sqcm with solvent joint inclusive of all necessary specials like bends, tees, offsets, doorbends, junctions, screw type caps with rubber rings for cleanout pipe ends, etc., suspended under floor slabs/fixed on walls or on pipe racks in shafts. All suspenders, saddles, pipe packs are to be quoted separately under relevant items.( Inclusive of verticals & horizontals at Internal Toilets )
4" PVC Pipe
3" PVC Pipe
Providing & Fixing 18 mm thick gang saw cut mirror polished ( Pre molded & pre polished) machine cut granite for urinal partitions of required size of approved shade, colour & texture laid over 20 mm thick base cement mortar 1: 4 ( 1 Cement : 4 Coarse Sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, molding & polishing to edge to give high gloss finish etc. complete at all levels.
Providing and fixing Modular partition for restroom cubicles made out of Approved make - ______ Series or equilevent as per Manufacturer's specifications. Including Doors with follwing accessories to be provided.
a )Aluminum Top Rail “SS” finish
b) “SS” Coat Hook with Door Stopper
c) “SS” Thumb turn c/w occupancy indicator,
d) “SS” Hinges
e) Aluminum “U” channel
f) Aluminum “F” channel
g) “SS” Adjustable Leg
h) “SS” Screws
Size - 1475 (L) x 1100 (w) with door
The fabric shall be Pre-stressed composite material of High Tenacity Polyester Yarn with PVC Coating & Micro-Aerated. Fabric shall be Soltis~96, coated fabric to provide subtle view of the side of the blind and insulates and dissipates heat. Fabric shall be GREENGUARD Indoor Air Quality & Children & School Certified. Composition: 39% Polyester / 61% PVC Weight:400 g/m2 Thickness:0.45 mm Visible Light Transmission: 3% - 5% (N-N) Solar Transmission : 4% - 21% Solar Reflectance : 7% - 70% Solar Absorption : 9% - 89% Tensile Strength (Warp/Weft): 220/220 daN / 5cm Tearing Strength (Warp/Weft): 30/25 daN Management system for Quality : ISO 9001 Fire Retardancy:M2 (NFP92-507) Fabric Warranty: 5 Years. comprising of Roller Tube shall be of extruded Aluminium alloy 38mm O.D (or as per system dimension) with a minimum wall thickness of 1.0mm duly anodised for long life. Clutch shall be wrap spring design with high strength fibreglass reinforced polyster assembly and high carbon steel springs to transmit motion from driving to driven members of clutch mechanism. Clutch shall operate by directionally with the use of an endless beaded chain. Clutch mechanism shall be crash proof, prevent slippage and shall raise and lower smoothly to any desired height.Clutch shall never need adjustment. Idler shall be of high strength fibreglass reinforced polyster,consisting of an outside sleeve and centre shaft. Sleeve shall provide bearing surface for roller tube and rotate freely on centre shaft, providing smooth, quiet and long wearing operation. Brackets shall be of tomised steel powdercoated to give superior finish. Bracket shall accommodateoverhead, side or face mounting with clutch assembly on either end of the roller. Bottom of the blind shall be provided with aluminium tube powder coated in a colour matching to the fabric. The fabric shall be enclosed in the suitably created pocket along with the tube. The tube shall be closed from sides with end caps to give a neat look.
Providing and fixing Anti Bacterial Fabric patient curtain of approved shade and colour. Cost also to include the fixing of 20 mm. dia. Heavy gauge Powder coated Aluminium pipe with end brackets to hang the curtain. All complete as per instruction of designer & Architect. Should be chemically tested stain retardant with track system of aluminium anodised section.
Providing and laying 1.5mm thick Anti-static vinyl flooring in roll form of width not less than 1.2 m of approved make over prepared existing surface and joined by cord welding to make it seamless, at all levels, as per manufacturers specifications including coving rounded junction between floor & wall with approved adhesive. Rate shall include all materials, preparation of base surface, adhesive for fixing, finishing the surface, providing 0.05mm thick & 12mm wide copper strip at required interval and work at all levels etc., complete. All complete as per instruction of Engineer In Charge
Providing, fixing and installing in position Hand Railing system of approved make, satin finish 304 grade stainless steel having 2 mm thick tube with 75mm dia handrail modular and 22mm dia pipe at 3 levels along the running length of ramp and vertical supports in 38mm dia SS pipes @ 1500mm c/c, with necessary supports, anchor fasteners, supports, base plates, SS counter sunk screws. The joinery should be assembled at site, including installation complete in all respect (height 1000mm). All complete as per manufacturer's specification & instruction of designers.
Supply and Installation of Guard Rail etc. complete as per manufacturer's specification & instruction of designers and Engineer In Charge.
Supply and installation of Laminate finish ledge all complete
Supply and installation of wooden patterns all complete
Supply and installation of wall art all complete
Supply and installation of Metal rafter Partition as per reference image
Supply and installation of Storage wooden rafter Partition as per reference image Providing & constructing laminate finished storage of width 450 mm to 600 mm & size as mentioned below, with top, sides & bottom in 18 mm thick commercial ply, back in 8 mm thick commercial ply, intermediates in 18 mm thick commercial ply @ 375 m c/c, shutters with framework as per drawings in 18 mm thick commercial ply. All external surfaces to be finished in approved 1.5 mm thick laminate, with balancing laminate on the interior surface. All exposed edges to be finished in approved PVC edge binding. Rate shall be inclusive of hardware such as locks, auto closing hinges for shutters, handles, door stopper, Tower bolt, SS key holes of approved make etc all complete.
Refixing of existing door panels with cleaning, making good, trnasporting from stored location and Polishing as directed by Engineer In Charge
Single Leaf - 900/1000/1200 x 2400
Double Leaf -1200/1500/1800/2100 x 2400
Supply and installation of Tables with following specifications
Table Top : 25mm thick pre laminated E1 grade ply board finished table top with reverse waterfall edge In approved shade laminate & 2mm thick PVC edge binding matching to laminate on all 4 sides. Adequate supports to be provided to the work surface for preventing it from sagging. The Metal finish 500 mm length flip up with rubber beading on soft close hinges should be provided on the work surface for wire management. The Scallop to be considered on table top for mounting monitor arm if required.
Under structure : The Workstation legs should have "A" leg design with trapezoidal profile section. The open table base should be assembled from the main beams, and end legs. The table base should be made of Metal with powder coated in approved shade finish. The base structure should be able to support the worktop of above mentioned length without intermediate support. And on the side of the table, which are facing the passage side should be consider with gable end with metal modesty panel with clip in arrangement. The leg supporting system should have adjustable levellers.
Cable carrier : Metal cable tray of width 200 mm x height 180 mm and length as per WKS in approved powder coated finish matching to under structure shade to be provided along main spine to carry the data and power cables with proper segregation for data and power along the workstations. The cut-out of 400 mm on the side of the cable tray (lengthwise) to be consider to access the additional power point in the cable tray located below each worktop. The reverse cable tray below flipper box to be considered for MEP switch socket . The metal riser box of size : 400 mm x 100 mm x 700 mm ht from the finish floor to be considered for wire management from floor junction box till bottom of the table.
Side Storage : The structure and the shelves is made out of 18mm thick pre-laminated E1 grade MFC board ,which are adjustable in height. The shutters are made out of 18mm(PLB), and fitted by hinges. Finger cut groove for shutters ,normal locking unit and levellers are considered.
Back Storage : The structure and the shelves is made out of 18mm thick pre-laminated E1 grade MFC board ,which are adjustable in height. The shutters are made out of 18mm(PLB), and fitted by hinges. Finger cut groove for shutters ,normal locking unit and levellers are considered. This is the combination of open and closed stoarge as per reference image. The size of the open storage is 700mm (L) x 450mm (d) x 750mm on both side of the back storage.
Size - 1200 x 600mm x 750mm.
Size - 1650 x 750mm x 750mm.
Size - 1600 x 600mm x 750mm.
Size - 1500 x 750mm x 750mm.
Meeting Table - 1050mm dia x 750mm (H)
Cabin Table -Table Size -1425mm x 750mm x 750mm , Side Storage -1000mm x 400mm (d)
Cabin Table -Table Size -1500mm x 600mm x 750mm , Side Storage -1050mm x 450mm (d)
Cabin Table -Table Size -1445mm x 600mm x 750mm , Side Storage -1050mm x 450mm (d)
Cabin Table -Table Size -1950mm x 750mm x 750mm , Side Storage -1200mm x 450mm (d)
Size : 450 mm (L) x 450 mm (W) x 725 mm (H) Providing & Fixing of mobile pedestal storage unit of size : 450 mm (L) x 450 mm (D) as per the layout. The storage unit shall have equal 3 Drawer unit( 2 Drawer +1 Filing cabinet) formed in approved 19mm thk Prelaminate board finish and intermediate side shelves finished with 12mm thk prelaminated board. The Edges finished with approved matching PVC edge band as per the details complete. The drawer unit formed in Prelaminate boards with central locking mechanism and concealed handle and all the necessary hardware.
Medium back Chairs : Stafff chairs- Back: Standard Soft mesh Lumbar: height adjustable lumbar Seat: Standard upholstered with foam Seat depth: Standard seat depth of 2" (51mm) Arms : height adjus table arms with soft arm caps Back-Lock: Standard one lock position at upright Tilt tens ion: standard tilt tension Seat height adjustment: Pneumatic seatheight adjus tment of 5" (127mm)Casters : Standard with hard casters
Medium back Chairs : Stafff chairs- Back: Standard Soft mesh Lumbar: height adjustable lumbar Seat: Standard upholstered with foam Seat depth: Standard seat depth of 2" (51mm) Arms : height adjus table arms with soft arm caps Back-Lock: Standard one lock position at upright Tilt tens ion: standard tilt tension Seat height adjustment: Pneumatic seatheight adjus tment of 5" (127mm)Casters : Standard with hard casters
Loose Furniture (as per 3d presentation and approved by Engineer In Charge/ Consultant)
waiitng area chairs- 2 Seater- 2-SEATER CUSHIONED - CUSHIONED TANDEM (LEATHERITE) FIXED ARMS - Inside Structure PU Moulded with Metal Base Duly Powder coated in SS Matt Finish.
waiitng area chairs- 3 seater - 3-SEATER CUSHIONED - CUSHIONED TANDEM (LEATHERITE) FIXED ARMS - Inside Structure PU Moulded with Metal Base Duly Powder coated in SS Matt Finish.
waiitng area chairs- 4 seater- 4-SEATER CUSHIONED - CUSHIONED TANDEM (LEATHERITE) FIXED ARMS - Inside Structure PU Moulded with Metal Base Duly Powder coated in SS Matt Finish.
waiitng area chairs- 5 seater - 5-SEATER CUSHIONED - CUSHIONED TANDEM (LEATHERITE) FIXED ARMS - Inside Structure PU Moulded with Metal Base Duly Powder coated in SS Matt Finish.
Preconsultation - Side table - Providing & Making Side table with 25mm thick table top finish with approved laminate & M.s Powder coated legs. As per 3d presentation and approved by Engineer In Charge/ Consultant 900mm(L) x 450mm(W) x 550mm(H)
Joint Clinic Table _ Table - Providing & Making Side table Table with BSL Top of 25mm thk with 2 side post forming & Side Edges finished with PVC Edge banding supported by MS bracket. Frame in Stainless Steel with center pipe of 60mm dia & base pipe 45mm T. 900mm dia x 750mm (H)
Nurse Duty Room Table - Table - Providing & Making Side table Table with BSL Top of 25mm thk with 2 side post forming & Side Edges finished with PVC Edge banding supported by MS bracket. Frame in Stainless Steel with triandle tapperd legs with wooden finish powder coating. 2400mm x 1050mm x 750mm
Nurse Duty Room Chairs- Chairs - Providing PP chair as per refernce image in 3d presentation and approved by Engineer In Charge/ Consultant
1. HVAC - BOQ LOW SIDE CHW AIR HANDLING UNITS
SECTION-I AHU (FLOOR MOUNTED/CEILING SUSPENDED)
AIR HANDING UNITS
ElECTRIC HEATER:- Supply, installation, testing and commissioning of Tubular type AHU mounted non‐flameproof Electric Air Heater Unit made out of 1mm thick GPSP sheet having 30mm flange. AISI 304 stainless steel Electric tubular heaters without fins having low watt density are provided with support brackets. The unit shall be equipped with safeties such as adjustable type primary thermostat, secondary thermostat manual reset type and Air flow switch to prevent the heater from operating without airflow. It shall be provided with a separate wall mounting control panel having suitable rating incomer MCB, ON/Trip indication light, contactor, Thyristor module to operate 0‐100% as per demand, terminal for AHU/Blower interlock, grounding terminal, power and control wiring. The unit shall be BMS compatible. (For 1KW capacity Heater units Single Phase Wiring and 1.5KW capacity onwards Three Phase Wiring) The unit shall be CE certified. (Capacity as specified below)
EC fan shall be complete with the controller
Cooling Coil Inlet Temp : 6.66 Deg C
Cooling Coil Outlet Temp : 12.22 Deg C
Maximum fan outlet velocity : 550 m/min
Maximum velocity of air across cooling coils and filter : 2.5 m/s
Motor speed : 1450 rpm
AHU 02 (Floor mounted) Type :AIR HANDLING UNIT Capacity : 15.9 TR USGPM : 38.16 USGPM Total Air Qty : 6500 CFM Fresh Air Qty : 1725 CFM Entering air condition :- DB 76.3 °F / WB 62.9 °F ESP :60 mm Wg (Contractor to carry out static pressure calculations and submit for Consultant's approval before procurement) (Air Mixing chamber With FA & RA Volume control dampers) & Thermal Brake : YES Complete with EC fan controller and compatiable with BMS. AHU Outlet shall have Fire retardant canvass connection, GI Volume control damper and Motorised Fire Damper Electric Heater :-25 kw
1 No of Spare EC Fan for Each Fan Size
1 No of Spare Filter set for Each AHU ( MERV-08, MERV-13)
Supply, installation, testing and commissioning of Bacnet IP DDC Controller, it shall be of equippted with onboard UIO's {10AI , 5AO , 7Di , 3DO, & 10 Points (min. requirement)} for EC fan soft integraion in Modbus485/ BACnet MSTP (with 20% spare). BTL certified must be listed as BACnet Building Controller ( B-BC) or BACnet Advanced Application Controller (B-AAC) , DDC must be freely programmable controller with a variety of integration interfaces. A fully customizable LCD display with a role-based access, the controller must be useful in various HVAC scenarios. Using the LCD as a part of an application the operator must be able to read and set control values, read alarms, set schedules, and configure the controller. The controller must be useful in various building scenarios, it shall be equipped with a variety of open communication protocols over IP and serial buses, like BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU/ASCII. ( the control panel shall have facility to operate mannually in case auto operation fails.)
Differential pressure switch for pre filter
Differential pressure switch for post filter
Duct Mounted Temp and RH Transducer
Duct Mounted CO2 Sensor
SECTION-II- CHW PIPING AND VALVES
INSULATED CHILLED WATER PIPING :
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) With thermal Insulation of Polyurethane foam pipe section having density of 36 kg/m3 & thermal conductivity of 0.023 W/m.K @ 10℃ mean temperature confirming to ASTM C177/ASTM C518. It shall have burning rate of 100 mm confirming to IS:11239 & water absorption of 2% confirming to ASTM D2842. Material shall have water vapour permeability of 3 ng/s.m.Pa confirming to ASTM E96. Insulation material shall be covered with 26 SWG Aluminum cladding sheet.
65 mm dia. ( 50 mm Thick PUF insulation)
50 mm dia. ( 50 mm Thick PUF insulation)
INSULATED VALVES
Supplying, fixing, testing and commissioning of following valves,strainers, gauges in the chilled water plumbing duly insulated to the same pecifications as the connected piping and adequately supported as per specifications
All valves and strainers shall have CI/DI body for sizes 65 mm and upwards. For sizes 50mm and below it shall have brass body.
FULLY LUGGED BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & 0- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
65 mm dia
BALL VALVES : (INSULATED)
Supply, installation, testing and commissioning of S S Ball Valves of approved make (PN16 rating) complete as per technical specifications.
50 mm Dia
BALL VALVES WITH STRAINER : (INSULATED)
Supply, installation, testing and commissioning of S S Ball Valves with Strainer of approved make (PN16 rating) complete as per technical specifications.
50 mm Dia
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled water circulation including insulation as specified
65 mm dia
AUTO AIR VENT WITH BALL VALVE
32 mm Dia
BALL VALVES( FOR DRAIN) : (INSULATED)
Supply, installation, testing and commissioning of Ball Valves of approved make (PN16 rating) complete as per technical specifications.
25 mm dia
PIBCV VALVES WITH ACTUATOR (INSULATED)
Supply, Installation, testing and commissioning of Pressure independent type 2 way Balancing and modulating Control valves in a single Unit of Valve as per specifications. The PICV valve for the AHU / CSU shall be suitable for 24V AC power supply, valve price to include 240/24V transformer, complete with installation and interconnecting copper piping along with actuator, controller and transformer for the valves. The valves shall be PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded. DN 40 & DN 50 Cast Iron Body, Ext. Threaded. DN 65 to DN 250 Cast Iron body, flanged connection. Duly mounted with Spring Return Modulating actuator IP42/54 Accordingly type suitable for 24V AC. Quoted price to include power supply panel (with IP 44 Enclosure) consisting of 230V Incomer, 230V/24V AC supply for PICV Valve and thermostat, along with supply & installation of 10mtr of power cabling and earthing from the transformer to the valve actuator. BMS connectivity shall be there for Actuator set point from BMS system.
65 mm Dia
50 mm Dia
TEMPERATURE SENSOR & CABLING
Supply & installation of 15mtr of 4C X 1.5 sqmm Copper Cable (flexible sheilded). Quoted price to include FRLS condiuit, earthing from the temp sensor to the PICV valve alongwith Cable termination & glands.
PRESSURE GUAGES WITH BALL VALVE
Pressure gauges with plastic coated syphon tube & ball valve1/2" dia., range 0 to 14 Kg/cm2, Stainless steel or Brass stem.
TEMPERATURE GUAGES
4" Dia Stainless Steel bulb with SS304 thermowell and other accessories.
Temp. Range 0 to 50º C
Supply, installation, testing and commissioning of drain piping of U-PVC pipe with 9 mm thick nitrile insulation and protective coating including all fittings, bends, flanges, and accessories etc.
50 mm dia
Note :- Quantities of chilled water / drain piping shall be as per final Approved shop drawings.
General Note :- AHU shall have Isolation valve, Strainer, thermowell with Temp. Gauge, Pressure Gauge with Syphon at Supply line and Isolation valve with Actuator with bypass line, thermowell with Temp. Gauge, Pressure Gauge with Syphon at Return line.
SECTION II : FANS
MIXED FLOW INLINE TYPE TOILET EXHAUST FAN
Forward Curved Fans
Electrical Room Exhaust Air Fan 250 CFM @ 10 mm wg Static Pr.
CABINET TYPE TOILET EXHAUST FANS
Supply, installation, testing & commissioning of single skin Cabinet type Inline fans for Exhaust Air suitable for installing in any position in the vertical or horizontal ducts. The casing shall be constructed of galvanised steel . The fan shall be DIDW with forward/Backward curved impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply or 220 + 10% volt single phase 50 cycles AC supply. In addition all fresh air fans shall be provided with prefilters & necessary accessories to mount the filters. All exposed fan shall be provided with 20 Gauge GI canopy weather proof anti corrosion protection with two layer of epoxy paint.
Toilet Exhaust Air Fan 700CFM @ 15 mm wg Static Pr.
Toilet Exhaust Air Fan 600 CFM @ 15 mm wg Static Pr.
PROPELLER TYPE EX FAN
SMOKE EXHAUST AIR FANS
AXIAL FANS FOR SMOKE EXHAUST SYSTEM
Supplying, installing, testing and commissioning of smoke spill fans. Fan, casing, motor, drive shall be suitable for smoke exhaust application & thermally rated for 250ºC for 2 hours as per [BS-7346 Part-2 : 1090] Class-H. Motors shall be High Temperature resistance smoke venting type suitable for 415+10% volts, 50 cycles , 3 phase AC supply with IP 55 protection, static pressure shall be as indicated. Each fan shall be with TEFC squirrel cage induction motors, all fan shall be with flexible fire proof connection at inlet and outlet. Suitable spring isolators to provided along with the fans. Spring mount Isolater to have Efficiency of above 90%. Quoted price to include MS structural work required for mounting the fans as indicated in the drawing. All Normal mode fans to have IE 3 Motors & Fire mode fans to have IE 3 motor.
Smoke exhaust air fan for common area
CFM : 8500 CFM @ 25 mmWG
Mode :-Fire
Dia :-800 mm
Power :- 3.0 kW
Noise Level @ 3 MTR :- 74 dB(A)
Efficiency :- 65%
Note-Contractor shall check out static Pressure calculation based on actual site conditions and submit to consultant approval before procurement.
SECTION-III AIR DISTRIBUTION PRODUCTS
AIR DISTRIBUTION
Air distribution rectangular ducting made out of G.S. sheet including collars, conforming to IS 277 including bracing, flanges, turning vanes, fastners, rivets, gaskets, nuts & bolts, etc. as per specifications. All exposed ducting shall have 2 finish coats of apporoved color, conforming to relevant BIS Codes and SMACNA Standard.
Duct Size 0 - 750 mm : 24 Gauge
Duct Size 751 - 1500 mm : 22 Gauge
DUCT ACOUSTIC INSULATION
Supply, Installation, testing and commisioning of Acoustic insulation material for ducting, the material shall be Open Cell Elastomeric Nitrile Rubber (NBR) with density of acoustic insulation material shall be within 140-180 Kg/m3. Thermal conductivity of insulation material shall not exceed 0.047 W/(m.K) at mean temperature of 20C as per EN 12667. The insulation material shall be Class 1 as per BS 476 Part 7, 1987 for surface spread of flame & UL 94 (HB, V-0) in accordance to UL 94, 1996. The acoustic insulation material shall have Microban®* antimicrobial product protection and shall pass Fungi / Mould Resistance as per DIN EN ISO 846 method A and Bacterial Resistance as per DIN EN ISO 846 method C, from an independent testing agency. The acoustic insulation material shall have good sound absorption, damping and barrier properties. The acoustic insulation material shall be dust and fibre free Adhesives to be GRIHA/IGBC compliant. Installation should be as per manufacturers SOP.
15 MM Thick
AHU ROOM ACOUSTIC INSULATION
Walls and ceiling of air handling unit rooms may be provided with acoustic lining. Material shall be processed from Nitrile rubber open cell foam.The material should be fibre free. The density of the same shall be 140-180 Kg/m3. The material should have thermal conductivity not exceeding 0.05 W/Mk. The maximum surface temperature of material shall withstand is 1050C. and minimum temp shall be -200C. Thickness shall be as specified. The material should confirm to class 1 rating for surface spread of flame as per BS 476 Part 7 & HBF, HF1 & FH 2 in accordance with UL 94, 1996. Thickness shall be as specified. Surface shall be cleaned and two coats of adhesive recommended by the manufacturer should be applied on the walls. The foam sheets should be cut to required size and a layer of adhesive should also be applied to it. When it is tack dry it is stuck to the walls / ceiling. All longitudinal and transfer joint shall be covered with 22-gauge 50 mm wide GI strip with screws. Acoustic lining of walls shall be terminated approximately 15 cm above the finished floor to prevent damage to insulation due to accidental waterlogging in plant/AHU / fan rooms.
25 MM Thick
DUCT THERMAL INSULATION
Supply, Installation, testing and commisioning of Thermal insulation for ducting, the material shall be Closed Cell Elastomeric Nitrile Rubber (NBR) laminated with >90% pure 12 microns ALU Foil. The thermal conductivity of insulation material shall not exceed 0.035 W/(m.K) at mean temperature of 0 deg C as per EN 12667. The insulation material shall be fire rated Class O as per BS 476 Part 6:1989 for fire propagation test and Class 1 as per BS 476 Part 7, 1987 for surface spread of flame. Density of insulation material shall be between 40 to 55 Kg/m3. The Insulation material shall be Moisture Diffusion Resistance Factor or ‘µ’ value of insulation material shall be minimum 7,000 without any external barrier as per EN 12086. Adhesives to be GRIHA/IGBC compliant. Installation should be as per manufacturers SOP.
19 MM Thick
Supply, installation, testing and commissioning of flexible connections constructed of fire resistant rexin material, as per approved shop drawing. The Flexible Duct Connector consisting of a flame retardant fabric, secured to galvanized sheet metal on either side by a double lock seam inserted between the equipment / air duct and the ductwork to provide a wear resistant Air tight flexible connection to eliminate vibrations, noise and rattles.
Supplying & fixing of powder coated extruded aluminium Supply/Exaust/Fresh Air Grills with aluminium volume control dampers as per specifications.
Supplying and fixing of supply air square diffusers of powder coated aluminium with OBD (aluminum volume control collar damper (Colour shall be as per Arch req) as per specifications complete as required.
All diffusers to have flange size 600mmX600mm to suite type grid ceiling
Supplying and fixing of return air square diffusers with volume control damper as per specifications complete as required.
All diffusers to have flange size 600mmX600mm to suite type grid ceiling
Supplying and fixing of supply air Round diffusers of powder coated aluminium with OBD (aluminum volume control collar damper (Colour shall be as per Arch req) as per specifications complete as required.
Supply, Installation, Testing and balancing of powder coated extruded aluminum Slot Diffusers. Each slot to have a 180 degree adjustable air pattern controller.
2 slot diffusers (1" slot width)
Supply, installation, testing and balancing of aluminum hit & miss type damper anodized in matt black shade in accordance with the approved shop drawings and specifications. The damper to be at the rear of the slot diffuser and separate for each individual slot. The dampers should be such that it can be operated from the front face of the slot diffuser and provides the flexibility of modulating the air flow in each slot individually as per site requirements
Damper for 2 slot diffuser (1" slot width)
Supply, installation, testing & commissioning of flexible ducts with inner and outer skin with Metallised polyester & helical spring sandwitched in between along with clamps & accessories.
Insulated flexible ducts with 25 mm thick fiber glass insulation between the inner and outer skin:
200 mm Dia Insulated Flexible Ducting
Supply & installation of factory fabricated Plenum boxes for slot diffusers constructed with 22 gauge GI sheets with single / double inlet connections as per approved drawings, sizes as mentioned below complete with butterfly damper. The plenum shall have 6 mm thick acoustic insulation from inside.
250 mm wide x 325mm high (Length shall vary as per the approved layouts)
Supply, Installation, testing and balancing of aluminium powder coated jet nozzles in accordance with the approved shop drawings. The jet nozzles to have an arrangement 360 º swivel of the nozzle there by providing flow adjustment upto 30 º in all directions.
Nozzle size: 280 mm Dia
Supply, installation, testing and balancing of circular butterfly dampers in the jet nozzle, damper should be adjustable from the centre of the jet nozzle, without requiring the removal of the jet nozzle.
280 mm Dia
Supplying, installing, testing and commissioning of Powder coated extruded aluminum, non vision air transfer door grilles, with flange at both side as per approved shop drawing.
Supply, installation, testing and balancing of aluminum volume control damper anodized in matt black shade in accordance with the approved shop drawings and specifications
Supply, installation, testing and comissiong of back draft gravity dampers manufactured from high quality aluminium alloy extrusions and assembled using screw fixing, welding and soldering techniques to form a robust construction. The blade pivot mechanism shall incorporate nylon bushes and stainless steel pins to ensure maintenance free operation.
Supply, installation, testing and commissioning of fusible link type fire damper with all necessary fire sleeves for installation in the wall, fire damper to be UL555 listed and to have atleast 90min fire rating. Coated price to be include Fusible link for fire damper (UL555 Certified)
Motorized Volume control dampers with actuator (with ON/OFF/STATUS) as specified. For item specification please refer specifications & drawings and complete the works in all respective ways
Motorised Volume Control Dampers - For AHU-01 &02 Fresh air
Actuators (4NM)
Control Panel (with IP 52 Enclosure) & Wiring
Supply, installation, testing and commissioning of motorised fire damper complete with control panel, inter connecting wiring at locations shown in approved shop drawings and as per specifications. Fire Damper to be UL555S listed and to have at least 1½ hour fire rating.
Fire Dampers
Actuators (3NM)
Actuators (4NM)
Control Panel (with IP 65 Enclosure) & Wiring
Note : -Dampers and accessories to be suitable for smoke exhaust purpose & the panel to be capable of receiving a signal from PLC panel / Fire alarm.
Note :- Quantities ofDucting / dampers & insulation shall be as per final Approved shop drawings.
Electrical (SECTION-IV HVAC RELATED ELECTRICAL WORKS)
Supply, installation, testing and comissiong of starter panel (IP 54 Rating) with DOL/Star Delta/VFD starter of required capacity incoming switch gear (MPCB), overload relay , control accessories like Elmex connectors, ferrules etc. with ON/OFF push button & indicating lamps (ON/OFF/TRIP), facility of control wiring for remote operation. Also potential free contacts to be provided for BMS. The panels to be designed considering 'Type 2' coordination.
3.0 kW : DOL Starter (Smoke Exhaust fans)
L.T. Power Cables
Supply, handling, laying proper connections testing and commissioning of following sizes of 1.1 kV grade XLPE insulated Armored Copper/ Aluminum conductor cables in an approved manner as required.
4C X 4 Sq.mm. XLPE, FRLS, Armoured Cable with Copper Conductor.
L.T. Power Cables Terminations
Supplying and erecting double compression type brass Cable Glands for XLPE with brass washers, rubber rings complete erected with cable ends leads including supply and erecting crimping type Cu/Al lugs confirming to IS suitable for cables evenly crimped with high pressure tools and connected to switch gear terminal with brass or cadmium plated nut bolt in an approved manner.
Terminations to be carried out with double compression brass glands and suitable lugs / ferrules.
4C X 4 Sq.mm. XLPE, FRLS, Armoured Cable with Copper Conductor.
Earthing Conductor
Supplying, laying of following mentioned earthing conductors connecting the following continuous earth conductors.
8 SWG. GI wire
CABLE TRAY
Supply and installation of hot dip galvanised iron cables trays as per technical specifications with mounting accessories, necessary bends couplers etc. for suspending from ceilings, beams or steel structure or on columns and walls. The rates to include for supply & installation of all the required structural steel supports, grouting, anchor fastner, G.I. hardware, etc.
Size 50 x 50 mm For elecical cable
CIRCUIT CUM POINT WIRING
GENERAL NOTE : For actual wire length , Contractor shall study the drawings before quote.If any deviation in length/points is found in BOQ & Drawing as per site condition, contractor to highlight the same to client/PMC.
Wiring of following light points with 2R x 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible HR FR-LHS LF wires in embeded 25mm dia. heavy duty HR FR-LHS LF PVC conduit as per IS 9537 part-3 including providing and fixing of 6 amps single pole rocker operated flush mounted switches of approved quality colour make and design in 1.6 mm thick GI box and earthing of fixture and the outlet box with 1.5 Sq.mm PVC insulated copper conductor stranded flexible HR FR-LHS LF wire. (Green Wire)
MCB controlled Primary point (from DB MCB to 1st light point)
Length of Mains Wiring for Primary Point may be assumed as 20 m
MCB controlled Secondary point ( from light point to light point )
Length of Mains Wiring for Secondary Point may be assumed as 10 m
Primary point with switch ( from switch board to first point - cost of switch & board included)
Length of Wiring for Primary Point may be assumed as 6 m
Secondary point without switch ( from light point to light point - cost of switch & board NOT included)
Length of Wiring for Secondary Point may be assumed as 5 m
Wiring for following 250 volt single phase and neutral 6 amps switch socket outlet with 2R x 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible HR FR-LHS LF wires in embeded 25mm dia. heavy duty HR FR-LHS LF PVC conduit as per IS 9537 part-3, including providing and fixing of 6 amps switch and 6A 3 pin socket of approved make colour and design in 1.6 mm thick GI box with grid plate and earthing of third pin of the socket outlet and the GI box with 2.5 Sq.mm PVC insulated copper conductor stranded flexible HR FR-LHS LF wire. (Green Wire)
6A switch socket (on SB Half point)
6A switch socket (individual)
Primary Point
Length of Wiring for Primar Point may be assumed as 10 m
Secondary Point
Length of Wiring for Secondary Point may be assumed as 5 m
Wiring for following 250 volt single phase and neutral 6 amps switch socket outlet with with 3C x 4 sq.mm Cu YWY 1100 volt grade XLPE insulated FRLS PVC outer sheathed copper conductor, including providing and fixing of 6 amps switch and 6A 3 pin socket of approved make colour and design in 1.6 mm thick GI box with grid plate. (For UPS Power Point)
6A switch socket
Primary Point
Length of Wiring for Primar Point may be assumed as 10 m
Secondary Point
Length of Wiring for Secondary Point may be assumed as 5 m
Wiring for 250 volts single phase and neutral 6/16 amps switch and socket outlet with 2R X 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible HR FR-LHS LF wires in embeded 25mm dia. heavy duty HR FR-LHS LF PVC conduit as per IS 9537 part-3, including providing and fixing of 16 amps switch and 5 pin socket of approved make and design in 1.6 mm thick GI boxes with grid plates and earthing the third pin of socket outlet with 1.5 Sq. mm PVC insulated copper conductor stranded flexible HR FR-LHS LF wire.
6/16A switch socket
Length of Wiring for Primar Point may be assumed as 10 m
Supply, installation & wiring of plug point with 3 phase industrial socket having CRCA sheet metal enclosure with 32A, 3 pin plug and earth socket and 32A, 3 pin, plug top with 32A, triple pole MCB, mains, switchgears with continuous earth wire.
Wiring for Exhaust fan point with 2 x 2.5 sq. mm. Insulated copper conductor 1100 volts grade stranded flexible HR FR-LHS LF wires of approved make in 25mm dia. 2mm thick embeded PVC HMS conduit including providing and fixing of 6 amps flush mounted switch at the normal switch level in 2 mm thick GI box and 6 amps 3 pin flush mounted socket outlet near exhaust fan and earthing of exhaust fan through the third pin of the socket outlet and GI box with 1.5 sq. mm. PVC insulated copper conductor strande flexible HR FR-LHS LF wire. (For percentage of metalic and non-metalic conduits which are to be considerd, kindly refer note 17 in preamble above in this section) (Average Length-8m)
Providing and fixing of Exhaut fan along with of size 300 mm.
Providing point wiring for 1 No. 20 Amp Socket mounted on an independent switchboard controlled by Single 20 Amp Single Pole Switch mounted on switchboard of toilet using using 2 X 4 sq. mm copper conductor PVC insulated FRLSH wires in rigid PVC MMS conduits in RCC slab & in Brick Walls of 25 mm, concealed in ceiling & walls with necessary pull boxes complete with 20 Amp single pole switch of approved make fixed on 50 mm depth concealed hot dipped GI outlet boxes with earthing screws flushed with wall and continuous earthing up to main switchboard from the Socket switch board using 2.5 sq. mm. PVC insulated FRLSH green color copper earth-wire including rate of GI box & termination lugs if required. Rate shall include circuit wiring from DB to Geyser switch.All Concealed Conduits to be clamped with approved shaddles with rust free screw/Nails.(Average Length-10m)
20 Liter Geyser
DB to SB circuit wiring
Providing circuit wiring for switch board controlled by MCB alredy installed in DB by using 2 X 1.5 sq. mm copper conductor PVC insulated HR FR-LHS LFH wires in rigid PVC HMS conduits in RCC slab & in Brick Walls of 25 mm, concealed in ceiling & walls with necessary pull boxes and continuous earthing up to main switchboard from DB to Switch board by using 1.5 sq. mm. PVC insulated HR FR-LHS LFH green color copper earth-wire.
Providing circuit wiring for switch board controlled by MCB alredy installed in DB by using 2 X 2.5 sq. mm copper conductor PVC insulated HR FR-LHS LFH wires in rigid PVC HMS conduits in RCC slab & in Brick Walls of 25 mm, concealed in ceiling & walls with necessary pull boxes and continuous earthing up to main switchboard from DB to Switch board by using 2.5 sq. mm. PVC insulated HR FR-LHS LFH green color copper earth-wire. (Including SB to SB Looping)
Providing circuit wiring for switch board controlled by MCB alredy installed in DB by using 2 X 4 sq. mm copper conductor PVC insulated HR FR-LHS LFH wires in rigid PVC MMS conduits in RCC slab & in Brick Walls of 25 mm, concealed in ceiling & walls with necessary pull boxes and continuous earthing up to main switchboard from DB to Switch board by using 2.5 sq. mm. PVC insulated HR FR-LHS LFH green color copper earth-wire.
PVC pipes
Supply and laying of 2 mm thick rigid FRLS PVC conduits in concealed conduit system using conduit accessories like junction boxes, collars, bends, elbows, binding wires, etc.
25 mm dia conduit
20 mm dia conduit
Sensor
Supply, Testing & Commissioning of Flush mount 360 degree ceiling mount sensor that combiner PIR, IR and Lux level control. The Sensor can also be placed in an automatic“Daylight Harvesting” mode for energy savings.
DISTRIBUTION BORDS / LT PANEL
LT PANEL
Design, fabrication, assembling, supply, installation, testing and commissioning of Main LT panel, Main Distribution Panels, Sub Distribution panels and Final Distribution panels suitable for 415 V, 3 phase, 50 Hz, 4 wire power supply system.
Panels shall be fabricated out of 2 mm thick CRCA sheet steel in cubical formation, compartmentalized in Form 3b Construction, floor mounted, free standing and shall be dust and vermin proof. 3 mm thick cable gland plate, shall be provided both at the top and the bottom of the panel.
Final distribution panels shall be fabricated out of 1.6 mm thick CRCA sheet steel and shall be wall mounted. All large panels shall be provided with lifting hooks. Distribution panels shall be fabricated in accordance with the specifications IS 61439 TYPE TESTED
FIRST FLOOR LIGHTING AND POWER PANEL
Incoming (1 No.)
125 amps,25KA FP MCCB with following accessories:
Phase indicating light through 415 / 110 V PT, primary & secondary of PT shall be protected by 2 amps SP MCB's. (1 Set)
Load Manager conserve EM 6400 with KWH reading for Grid supply (1 Set)
Class – C, 20KA, TVSS surge arrestor(Lines to Neutral) & (Neutral to Earth) suitable for 3 phases, 4 wire. (1 No.)
Breaker ON / OFF / TRIP indicating lights with control MCB’s. (1 Set)
Bus Bars
125 amps ,25kA,FP Aluminium bus bars with coloured heat shrinkable insulated sleeve. (1 Set)
Outgoing
80 amps, FP MCCB (2 No.)
63 amps, FP MCB (7 No.)
32 amps, FP MCB (5 No.)
25 amps, FP MCB (3 No.)
32 amps, DP MCB (1 No.)
16 amps, DP MCB (6 No.)
FIRST FLOOR LIGHTING AND POWER PANEL As described above
DISTRIBUTION BOARDS
Supply, installation, testing and commissioning of the following FDB's fabricated out of 1.6 mm thick CRCA sheet steel, double door construction, powder coated with approved shade and partitions to segregate phases. Approved lockable covers with padlocking arrangement for each phase, recessed in wall or surface mounted final distribution boards of the following description:
-Class - C (For SPN final distribution boards) (lines to Neutral) (Neutral to earth) suitable for 1 Phase as per specification and Class - C (For TPN final distribution boards) (lines to Neutral) (Neutral to earth) suitable for 3 Phase as per specification
12WAY TPNLDB
Incoming
32 amps FP MCB
Outgoing
25 amps DP ELCB ,30ma - 03
10 amps SP MCB - 15
16 amps SP MCB - 15
All MCB/RCCB/RCBO shall be of …10.. KA (Ics) breaking capacity.
12 WAY SPN ELDB
Emergency Lighting Distribution Board ELDB 12 Way SPN DB consisting of 4 KVA Inverter with 15 minutes Battery Backup, MCB in enclosure with required rack to mount battery & inverter & shall comprise of Incomer :
Incoming Breaker
32A, 10KA, 230 volts, 50 Hz., AC DP, RCBO-1 No.
Outgoing Breakers
10A, ,230 volts, 50 Hz., AC SP MCB - 10 Nos
All MCB/RCCB/RCBO shall be of …10.. KA (Ics) breaking capacity.
Used for - EMERGENCY LIGHT DB
12WAY TPN PPI NPDB-1,2 & 3
Incoming
63 amps FP MCB
Outgoing
32 amps DP ELCB ,30ma - 03
10 amps SP MCB - 00
16 amps SP MCB - 36
All MCB/RCCB/RCBO shall be of …10.. KA (Ics) breaking capacity.
12WAY TPN PPI UPSDB
Incoming
32 amps FP MCB
Outgoing
25 amps DP ELCB ,30ma - 03
25 amps SP MCB - 00
16 amps SP MCB - 36
All MCB/RCCB/RCBO shall be of …10.. KA (Ics) breaking capacity.
12WAY VTPN DB FOR EQUIPMENT
CABLES, MAINS, SUB MAINS AND CABLE TRAYS
Supplying & laying of following 1100 volt grade XLPE insulated PVC inner sheathed and FRLS PVC outer sheathed aluminium conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning.
3.1/2 core 95 sq.mm
3.1/2 core 50 sq. mm
Supplying & laying of following 1100 volt grade XLPE insulated FRLS PVC outer sheathed copper conductor armoured cable as per specification in existing trenches, cable trays ducts , clamped to wall with suitable clamps, including fixing bolts, connecting testing and commissioning.
4 core 16 sq.mm
4 core 6 sq.mm
4 core 4 sq.mm
4 core 2.5 sq.mm
3 core 6 sq.mm
3 core 2.5 sq.mm
Providing Mains Wiring from Meter panel panel to DB using copper conductor PVC insulated FR wires in rigid PVC conduits of 32 mm and 1.8mm wall thickness ISI mark, concealed in wall & ceiling with necessary boxes/pull boxes complete with continuous earthing up to main switchboard from the Distribution board using PVC insulated green color copper earth-wire.
4 sq.mm copper wire
6 sq.mm copper wire
2.5 sq mm copper wire
1.5 sq.mm copper wire
Cable end termination of the following XLPE insulated FRLS PVC outer sheathed aluminium/copper conductor armoured cables of 1100 volt grade including supplying and fixing of bimettalic crimping lugs, double compression glands with earthing.
3.1/2 core 95 sq. mm. Aluminium Cable
3.5 core 50 sq. mm Aluminium Cable
4 core 16 sq. mm copper cable
4 core 6 sq. mm copper cable
3 core 6 sq. mm copper cable
4 core 4 sq.mm copper cable
3 core 2.5 sq.mm copper cable
Supply and fixing of Hot Dipped Galvanised factory fabricated GI ladder type cable trays, with radial bends, suspenders and supports as per specification and of the following sizes as per standard manufacturers specifications.
100 mm (W) X 50 mm (D)
Supply and fixing of Perforated Type Hot Dipped Galvanised factory fabricated GI cable trays of the following sizes as per standard manufacturers specifications including providing GI suspenders and supports as per specifications.
100 mm (W) X 50mm (D)
G.I. Trunking/ Raceway & all other accessories
G.I. Trunking / Duct / Raceway & all other accessories – 50 x 40mm (W x H) - (16 SWG - 1.6 mm) with cover without partition
G.I. Trunking / Duct / Raceway & all other accessories – 100 x 40mm (W x H) - (14 SWG - 2mm) with cover without partition
INSTALLATION OF LIGHTING FIXTURES
Installation of the following lighting fixtures with all fixing accessories etc. as required.
24W-Recessed LED Down Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
36W-2'-0" X 2'-0" Recessed LED Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
24W-Suspended Cylindrical Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
24W-SuspendedLinear Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
24W-Recessed LED Down Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
3W Per-Meter LED Cove Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
3W Per-Meter Concealed Linear LED Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
24W-Recessed Twin light Fixture (Philips or Equivalent as confirmed by Client/Architect)
24W-Suspended Cylindrical Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
1X36W LED Single Luminaire Ceiling Mounted Surface Down Light Fixture (Philips or Equivalent as confirmed by Client/Architect)
SUPPLY OF LIGHTING FIXTURES
Supply of the following lighting fixtures with all fixing accessories etc. as required.
24W-Recessed LED Down Light Fixture (Equivalent as confirmed by Client/Architect)
36W-2'-0" X 2'-0" Recessed LED Light Fixture ( Equivalent as confirmed by Client/Architect)
24W-Suspended Cylindrical Light Fixture ( Equivalent as confirmed by Client/Architect)
24W-SuspendedLinear Light Fixture ( Equivalent as confirmed by Client/Architect)
24W-Recessed LED Down Light Fixture ( Equivalent as confirmed by Client/Architect)
3W Per-Meter LED Cove Light Fixture ( Equivalent as confirmed by Client/Architect)
3W Per-Meter Concealed Linear LED Light Fixture ( Equivalent as confirmed by Client/Architect)
24W-Recessed Twin light Fixture ( Equivalent as confirmed by Client/Architect)
24W-Suspended Cylindrical Light Fixture ( Equivalent as confirmed by Client/Architect)
1X36W LED Single Luminaire Ceiling Mounted Surface Down Light Fixture ( Equivalent as confirmed by Client/Architect)
EARTHING INSTALLATION (FOR POWER DISTRIBUTION SYSTEMS, UPS SYSTEM, DG SETS & EPABX)
Supply and fixing of following bare copper /GI tapes / wires including all necessary fixing accessories and effecting connections as per specifications.
50 x 6 mm thick GI tape.
32 x 6 mm thick GI tape.
25 x 3 mm thick GI tape.
8 SWG GI wire
FIRE FIGHTING INTERNAL BOQ
AUTOMATIC 'SPRINKLERS SYSTEM
Supply,Installation , Testing , Commissioning of 15 mm dia. quartzoid bulb type Brass Gun Metal pendent sprinkler head set to operate at 68 Deg C (UL/FM Approved) and as per IS 9972(For tower foot print area) as per specification and directed/approved by Engineer-in-Charge K factor:80
Supply,Installation , Testing , Commissioning of 15 mm dia. quartzoid bulb type Brass Gun Metal upright sprinkler head set to operate at 68 Deg C (UL/FM Approved) and as per IS 9972 (For tower foot print area) as per specification and directed/approved by Engineer-in-Charge K factor:80
Galvanised "C" class pipes (IS 1239 Part "I") including cutting, screwing, welding etc providing all G.I. forged fittings if pressure is PN 25 and maleable fittings if pressure is PN 20 and below (IS 1239 Part "II") such as bends, reducers, flanges, with G. I. clamps , hangers, using GS angles (along with zinc coating of 75 micron 555 GSM), channels complete with anchor, bolts wooden cleates, clamps etc including cutting holes and chases in brick or RCC walls / slabs and making good the same to the approval of Architect / Consultants, complete. as per specification and directed/approved by Engineer-in-Charge
Including painting with 2 coats of zinc primer & 2 coats of synthetic enamel fire red paint & with labeling on fire pipe of approved make
Testing hydraulically 1.5 times of the working pressure required at each floor
Pipes upto 50mm dia threaded joints or soctet welding , 65mm and above butt welding joint after making groove
Cost shall be inclussive of labeling & Flow direction on fire pipe
150 mm dia.(Vertical inside fire shaft)- GI PIPE
100 mm dia.- GI PIPE
80 mm dia- GI PIPE
65 mm dia.- GI PIPE
50 mm dia. - GI PIPE
40 mm dia.- GI PIPE
32 mm dia.- GI PIPE
25 mm dia- GI PIPE
Supply,Installation , Testing , Commissioning of Normal type Rosette plate for sprinkler as per false celling details all accessories as per specification and directed/approved by Engineer-in-Charge
Supply, installation, testing & commissioning of Stainless steel corrugated braided flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be 30 bar pressure rating and with union / reducer collar, clamps etc. as required.
1500 mm long 25 mm dia
1000 mm long 25 mm dia
PORTABLE FIRE EXTINGUISHERS
ISI marked (IS 14609) portable fire extinguishers, A.B.C. dry powder(Mono Ammonium phospate 90% filling chemicals) type of with pressure gauge, discharge hose and nozzle and complete in all respects including initial fill.supoort details as per drawing as per specification and directed/approved by Engineer-in-Charge
PLUMBING
FIXTING OF INTERNAL SANITARY FIXTURES & FITTINGS
Receiving,Fixing,Testing and commissioning of Wall Mounted type Glazed Vitreous Chinaware European Water Closet Pan, PVC Anti-microbial seat cover, C.I Chair bracket (painted with two coats of enamel paint over a coat of primer)/ rack bolt, nuts brass screw, washer all accessories required to complete the WC installation cost shall be inclusive of cutting, grooving, making good the walls etc. complete as per drawings, specifications and direction of the engineer-in-charge.
Receiving,Fixing, testing and commissioning of Indian Orrisa / Indian pan type Glazed Vitreous China ware Water Closet Pan, Open Flush Tank with Internal Fittings including supply of P/S trap, 32 mm Waste Pipe from Flush Tank to water closet, soil pipe upto outside face of toilet wall including cutting, grooving, making good the walls etc. all complete as per drawings, specifications and direction of the engineer-in-charge.
Receiving,Fixing,Testing and commissioning of Concealed Flush tank and flush plate, 6/3 Dual Flush Tank, Cost shall be inclusive of 32mm pipe from flush tank to water closet and required accessories including cutting, grooving, making good the walls etc. complete as per drawings, specifications and direction of the engineer-in-charge.
Receiving,Fixing,Testing and commissioning of Wall hung/Counter top Hand Wash Basin, & pillar cock, including fixing of C.P. Waste Coupling and C.P. Bottle Trap, 15mm C.P. threaded Inlet connections from Angle Stop cock to Basin, fixing of MS/CI brackets, including drilling holes in walls, grooving and making good the damages etc. complete as per the direction of engineer-in-charge.
Receiving,Fixing Glazed vitreous Urinal with senor operated tap System including fixing of CP Waste Coupling and CP Bottle Trap including fixing of M.S. brackets for the same, including drilling in walls and making good the damages etc. complete as per the direction of engineer-in-charge.
Receiving,Fixing,testing and commissioning of Health faucet with flexible pipe 1.5 m long, wall hooked complete as required.
Receiving,Fixing, Testing and commissioning of 15 mm dia CP brass 2-way short body bib cock with CP wall flange as per direction of engineer-in-charge.
Receiving,Fixing,Testing and commissioning of C.P. Angle Stop Cock with C.P. wall flange including fixing of 600 mm long flexble tube etc complete as per direction of engineer-in-charge.
Internal Drainage (soil, Waste & Vent)
SITC of uPVC SWRSWR Type B 6 kg/sq cm confirming to IS 13592 laying,jointing pipes in sunken and raised areas. with necessary cutting to be done to the required length including short pieces, assorted fittings such as plug/plain tee, bend, single/double Y, offsets etc. as per IS 14735, jointing with solvent cement, clamping on slab using G.I support such as hanger, Split clamp, saddle clamp etc. (not less than 555 GSM (75 Micron). galvanization thickness). giving water-tightness test for the pipes complete as per directions of engineer-in-charge. (Inside toilet)
75 mm dia
110 mm dia
SITC of uPVC pipes SWR Type B as per IS 13592 and fittings confirming to IS 14735 of approved makes, concealed / exposed on walls of following diameters for Waste pipe with required fittings and jointing material etc. including short pieces, assorted fittings such as plain tee, bend, single/double Y, offsets etc. as per IS 14735, jointing with solvent cement complete, as per directions of engineer-in-charge. Pipe works shall be supported with Hot dipped galvanized supports such as split clamp, saddle clamp GI trheaded rod etc. of 555 GSM (75 Micron). galvanization. (Inside toilet)
40mm dia
SITC of 75 mm uPVC Nahani Trap as per IS 14735 with water seal not less than 50 mm, with material and labour etc. complete as per directions of engineer-in-charge.
SITC of 75 mm uPVC multitrap as per IS 14735 with water seal not less than 50 mm, with material and labour etc. Multitrap shall be supported with slotted angle, GI theraed rod of 555 GSM (75 Micron). galvanization complete as per directions of engineer-in-charge.
SITC of Stainless Steel grade 304 Grating for floor trap Round /square including frame & provision of cockroach trap and fixing on tiles, including water proofing of the trap etc.complete as per direction of engineer-in-charge.
INTERNAL WATER SUPPLY
SITC of CPVC pipe of SDR11 including labour following sizes, pressure rating conforming to ASTM D-2846 for water supply including all types of fittings in provided grooves, equivalent jointing material, including testing and making good to the damages by bringing them to good original condition and complete in all respects including redoing the plaster to original condition complete as directed by engineer-in-charge. (Inside toilet)
SITC of full bore CPVC Ball valve (Solvent welded) with union and following diameter & approved make with material and labour etc complete as per directions of engineer-in-charge.
15 mm dia
20 mm dia
25 mm dia
INTERNAL STORM WATER
AC Drain pipe
SITC of UPVC SWR class A pipe 6kg/sq cm as per IS 13592 with necessary cutting to be done to the required length including short pieces, assorted fittings such as plug/plain tee, bend, single/double Y, offsets etc. as per IS 14735, jointing with rubber rings in vertical connection and solvent weld in horizontal connection, clamping on wall by G.I support (not less than 555 GSM (75 Micron). galvanization thickness)with U clamp, Square slotted support, threaded rod, and giving water-tightness test for the pipes laid in the sunken portion (AC Drain) along with making holes in walls/floor grooving and redoing the same and brick support etc. complete as per directions of engineer-in-charge. (Inside toilet)
HOT WATER SUPPLY (CENTRALIZED HEAT PUMP WOULD PROVIDE HOT WATER)
SITC of cPVC pipe of SDR11 of following sizes for inside toilet/Kitchen with all necessary fittings & accessories like tees, bends, elbows, reducers, unions, nipples, etc. / including concealing the pipes in walls or under floors, making chases in the walls, fixing in the wall with clamps and making good the wall surface etc. complete hydraulic pressure testing conforming to ASTM D-2846 for water supply after laying the pipes as specified including making holes in the walls or floors as required and making good to the damages by bringing them to good original condition and complete in all respects including redoing the plaster to original condition complete as directed by engineer-in-charge. (Inside toilet)
20 mm dia
15 mm dia
SITC of insulation to hot water pipe of following diameter with elastomeric nitrile rubber sleeve of approved make of 9 mm thickness concealed in toilets including covering the nitrile rubber with a protective tape and fire retardant resin etc. complete as directed by engineer-in-charge. (Rate to be quoted per m of pipe length)
20 mm dia
15 mm dia
SITC of forged brass ball valve with forged brass ball suitable for operating pressure of not less than 10 kg / sq.cm of the following size (Cost shall be inclusive of recieving necessary union/flange connection)
20 mm dia
15 mm dia
SITC of C.I. Non-return valves as per IS:5312 (of PN 10) swing check type with required flanges, nuts, bolts and gaskets etc. complete
15mm dia
ELV & PAFA BOQ
Detectors
Supply, installation, testing & commissioning of Analogue Addressable Photoelectric Smoke detectors with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). Detector should have drift compensation feature & integrated EMI/EMC circuit to monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.The detector shall have IP 44 protection catagory & ambient temperature -20⁰C to + 60⁰C. The quoted item shall completely comply to the technical specification.Shall be Vds approved according to EN 54-5, 54-7, 54-17, 54-29 or UL with LED design provides 360° viewing angle including detector mounting base, junction box & required accessories complete. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector)
Supply, installation, testing & commissioning of Analogue Addressable Multi - Sensor detectors (Heat + Smoke) with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). Detector should have drift compensation feature & integrated EMI/EMC circuit to monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.The detector shall have IP 44 protection catagory & ambient temperature -20⁰C to + 60⁰C. The quoted item shall completely comply to the technical specification.Shall be Vds approved according to EN 54-5, 54-7, 54-17, 54-29 or UL with LED design provides 360° viewing angle including detector mounting base, junction box & required accessories complete. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector)
Supplying, installation, testing & commissioning of Response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Addressable Fire Alarm System
Alarm Initiating Devices
Supply, installation, testing & commissioning of Addressable Manual Call Points Dual action Break Glass Type . The same shall be square in shape & made of ABS plastic material. Surface / Flush Mounting. It shall have a "Pull in case of fire " message embedded on the MCP. The addressable module shall be enclosed in a junction box & with required accessories. The quoted item shall completely comply to the technical specification.shall be UL or Vds approved
Notification Appliance
Supply, installation, testing & commissioning of Addressable loop Powered Sounder / Hooter. The sounder shall be made of ABS plastic material & have the Db level of minimum 85dBs and a multi tone facility, wall / ceiling mounted with mounting base & required accessories complete. The quoted item shall completely comply to the technical specification.shall be UL or Vds approved.
I/O Modules
Supply, installation, testing & commissioning of Addressable Telephone Module with Surface/wall mounting box & required accessories. Complete Integration of Cable from TM to third party system panel are also included in scope along with commissioning. The quoted item shall completely comply to the technical specification.shall be UL or Vds approved.
For Telephone Jack
Supply, installation, testing & commissioning of Addressable Monitor Module with Surface/wall mounting box & required accessories. Complete Integration of Cable from MM to third party system panel are also included in scope along with commissioning. The quoted item shall completely comply to the technical specification.shall be UL or Vds approved.
For Monitoring Flow Switch & Tamper Switch
Supply, installation, testing & commissioning of Addressable Relay Control Module with surface/ wall mounting box & required accessories complete (for Third party integration). Integration of Cable from RCM to third party system panel are also included in scope along with commissioning. The quoted item shall completely comply to the technical specification.shall be UL or Vds approved.
For PA System integration
For Access Control Panel integration
For AHU
For MSFD
Cables & Conduit
Supply & laying of 2 Core x 1.5 or 1.0 Sq.mm, Multistrand Annealed Bare Copper Conductor- Class 5, Overall Shielding, Twisted pair, XLPE insulated, FRLSH Armoured cable, RED in colour, laid on cable tray / wall / slab or structure with necessary GI saddles & spacer at 0.4 meters interval. complete with Lugs, Cable Compression Glands, Cable tags and ferruling. scope shall also include required end termination using gland, lugs & required accessories. Note- Refer cable technical specification (Red in Colour)
Supply & laying of 2 Core x 1.5 or 1.0 Sq.mm, Multistrand Annealed Bare Copper Conductor- Class 5, Overall Shielding, Twisted pair, XLPE insulated, FRLSH Flexible cable, RED in colour, laid on cable tray / wall / slab or structure with necessary GI saddles & spacer at 0.4 meters interval. complete with Lugs, Cable Compression Glands, Cable tags and ferruling. scope shall also include required end termination using gland, lugs & required accessories. Note- Refer cable technical specification (Red in Colour)
Supply, Installation Testing and commissioning of 25 mm diameter MMS FRLS PVC CONDUIT concealed in ceiling slab/wall, Floors complete with PVC adaptor, Junction boxes, bends couplings, PVC bushes, check nuts, rope pulling (Fish wire) and Clearance of any choked conduit is Contractor's responsibility. all accessories. (FOR MCP VERTICAL DROP)
Fire Fighting Telephone
Equipment
Supply installation Testing & commissioning of Addressable Fire Fighter Telephone Jack with Stainless steel face plate & metal junction box & required accessories.
Cables & Conduit
Supply & laying of 2 Core x 1.5 Sq.mm, Multistrand Annealed Bare Copper Conductor- Class 5, Overall Shielding, Twisted pair, XLPE insulated, FRLSH Armoured cable, RED in colour, laid on cable tray / wall / slab or structure with necessary GI saddles & spacer at 0.4 meters interval. complete with Lugs, Cable Compression Glands, Cable tags and ferruling. scope shall also include required end termination using gland, lugs & required accessories. Note- Refer cable technical specification (For FFT Integration)
Supply & laying of 2 Core x 1.5 Sq.mm, Multistrand Annealed Bare Copper Conductor- Class 5, Overall Shielding, Twisted pair, XLPE insulated, FRLSH Flexible cable, RED in colour, laid on cable tray / wall / slab or structure with necessary GI saddles & spacer at 0.4 meters interval. complete with Lugs, Cable Compression Glands, Cable tags and ferruling. scope shall also include required end termination using gland, lugs & required accessories. Note- Refer cable technical specification (For FFT Integration)
Supply, Installation Testing and commissioning of 25 mm diameter MMS FRLS PVC CONDUIT concealed in ceiling slab/wall, Floors complete with PVC adaptor, Junction boxes, bends couplings, PVC bushes, check nuts, rope pulling (Fish wire) and Clearance of any choked conduit is Contractor's responsibility. all accessories.(FOR FFT TELEPHONE JACK VERTICAL DROP)
Public Address System
Speakers
Supply, installation, testing & commissioning of EN 54-24 certified 6 Watt Cone type Ceiling Mounted metal grill Speakers with line matching transformer, Power tapping: 1.5W/3W/6W & screw clamp mounting with required accessories. (Colour - White) Note - Vendor to consider backbox if mounted on non false ceiling or surface area.
Switcher Console And Hardware
Cables And Conduits
Supply & laying of 2 Core x 1.5 Sq.mm, Multistrand Annealed Bare Copper Conductor- Class 5, Overall Shielding, Twisted pair, XLPE insulated, FRLSH Armoured cable laid on cable tray / wall / slab or structure with necessary GI saddles & spacer at 0.4 meters interval. complete with Lugs, Cable Compression Glands, Cable tags and ferruling. scope shall also include required end termination using gland, lugs & required accessories. Note- Refer cable technical specification (Colour- Grey)
IP CCTV Surveillance System
IP Cameras
Supply Installation, testing & commissining of Indoor/outdoor type 5 MP Fixed Lens Network Dome Camera with 1/2.5" progressive scan CMOS, integrated 2.8mm Fixed Lens, Resolution- 2688 ×1520@30fps, Minimum Triple Stream Support, Inbuilt Smart IR LED upto 20m distance, 0.01 lux color/0 lux with IR LEDs on, H.264 and H.265 encoding support, 120dB True WDR, True Day/Night, BLC, Built in Power over Ethernet (PoE), & 12VDC operated, in-built features-motion detection, tampering alarm, IP66 & IK10 protection, ONVIF Profile S & G compliant, with Junction box & required accessories. (Location- Lift Lobby)
Supply, Installation, Testing & Commissioning of 5MP Dome Camera, True Day Night camera with IR Illuminator, 1/2.8” 5 Megapixel progressive scan CMOS, 2560x1920 (5MP), DC/ P Iris, AGC - Auto/Manual, WDR, 120dB, Triple streams, Varifocal lens 2.8 - 12 mm, Remote Focus, BLC, 3DNR, with Edge Analytics, Motion Detection & Tampering detection, Profile G, S, T supported, Auto White Balance, Privacy Mask, high power LEDs IR with upto 30m IR distance, Min 256GB SD Card Slot provision, PoE, IP 66 & IK10 Having Operating temp range : –30°C to 55° C, Embedded Cyber Security, NDAA Compliant, ONVIF compliant, UL, BIS
Supply, Installation, Testing & Commissioning of Indoor Fish Eye 360 deg Panaromic type IP Camera, Minimum 5 MP resolution, 1/3"CMOS 360 degrees panaromic view lens, Cameras auto iris with fisheye lens minimum of 1.16 mm, with minimum Illumination of 0.3 lux (Colour) & 0.01 lux (B/W) Cameras(high resolution cameras/ 25 FPS) camera should be True Day/night,Motion, True WDR, tamper and audio detection, Electronic shutter,White balance,BLC,DC IRIS, Anti-flicker,Vandal proof Housing(IEEE802.3 CLASS 3 / wattage less than 6 watts.) IP66 & IK10, NEMA 4X Ratings,with required fixing accessories such as stand etc. Camera should be POE Enabled & should be FCC & UL listed/Approved & also ONVIF (S, G & T) compliant. Camera shall also comply to Cyber security norms, with Basic Edge Analytics features such as Motion detection, Tamper detection, Video blur detection.Software Simulation results to be provided for Coverage of Cameras with Resolution, lens, Target distance, PPM range, dead zone etc., as required.
Cables & Conduit
Supply, laying & testing of Cat 6 UTP Armoured cable including labelling and end termination with connectors both end.
ELV NETWORKING SYSTEM + IP PABX SYSTEM
ACTIVE COMPONENTS
Note- Following configuration & details to be provided by Vendor during Network switch configuration & Handing Over. Vlan configuration on L3 switch and L2/edge switches, Identifying application wise port requirement on L2/edge switches, Port wise Vlan assignment on L2/edge switches, Inter Vlan restrictions / Access rules to be configured, Apply QoS for Voice Vlan, Configuring IP address for each switch, Configuration Information/ training, IP address details, configuration and backup of each switch. Mapping, Numbering, tagging details etc. 1 nos of VLAN to be created on same network as below a) CCTV separate VLAN network
SITC of Basic L2 features 48 Port PoE auto-sensing 10/100/1000 Manageble Network Switch with 2 SFP Port and 2 X 1G Uplink Ethernet Ports. including standard connectivity & required accessories. (For Camera)
SITC of auto-sensing 10/100/1000 Network 48x1G PoE+ , 2x1G, 2xSFP Managed Switch including standard connectivity & required accessories. Core Switch for IT Infrastructure.(IPABX)
SITC of auto-sensing 10/100/1000 Network 24x1G PoE+ , 2x1G, 2xSFP Managed Switch including standard connectivity & required accessories. Core Switch for IT Infrastructure.(IPABX)
PASSIVE COMPONENTS
SITC of CAT 6, 48 port Loaded Patch Panel with accessories.
SITC of CAT 6, 24 port Loaded Patch Panel with accessories.
SITC of CAT-6 Patch Cord - 1 meter (at n/w rack side)
Faceplate IO's RG11 CATV Co-axial I/O Network Keystone Jack + Gang Box + Face Plate (for IP TV)
Faceplate IO's RJ45 CAT6 LAN I/O Network Keystone Jack + Gang Box + Face Plate (for DATA)
Faceplate IO's RJ45 CAT6 LAN I/O Network Keystone Jack + Gang Box + Face Plate (for Telephone)
IP PBX TELEPHONE
IP Telephony Instrument With Digital Display, Handsfree Speaker with the facility of - Mute, Flash, pause & Redial
Operator Phone with speed dial extention.
IP Phone with Video call facility for management team
SIP Phone (Hybrid)
NETWORK RACK & ACCESSORIES
Supply & installation of 15U 800 X 1000mm (D) Floor/Wall mount Rack with Front Glass Door, Fan Tray on Top (4nos.), Perforated Rear Doors, Openable Entry at the Bottom for the Cable entry, Casters, 5 nos. Fixed shelf, Cable Basket for Cable Dressing & 3 Nos Horizontal Power Strip with 5/15 A Universal Sockets (having both flat and round pin), hardware & accessories to mount the passive & active equipments.
CABLES & CONDUITS
Supply, laying & testing of Cat 6 UTP cable including labelling and end termination with connectors both end. (FOR TELEPHONE)
IT NETWORKING SYSTEM
ACTIVE COMPONENTS
Note- Following configuration & details to be provided by Vendor during Network switch configuration & Handing Over. Vlan configuration on L3 switch and L2/edge switches, Identifying application wise port requirement on L2/edge switches, Port wise Vlan assignment on L2/edge switches, Inter Vlan restrictions / Access rules to be configured, Apply QoS for Voice Vlan, Configuring IP address for each switch, Configuration Information/ training, IP address details, configuration and backup of each switch. Mapping, Numbering, tagging details etc.1 nos of VLAN to be created on same network as below
SITC of Basic L2 features 48 Port Non PoE auto-sensing 10/100/1000 Manageble Network Switch (Cisco Catalyst 9300 48-port data only), Network Essentials with 4 x 10G Network Module Uplink Ethernet Ports. including standard connectivity & required accessories.(For Data Network)( Details in annexure 1)
SITC of Basic L2 features 24 Port PoE auto-sensing 10/100/1000 Manageble Network Switch (HPE Aruba Networking CX 6100 24G Class4 PoE 4SFP+ 370W Switch) with 4x10G fixed uplinks Ethernet Ports including standard connectivity & required accessories. (For WiFi Data Network)
PASSIVE COMPONENTS
SITC of CAT 6, 48 port Loaded Patch Panel with accessories.
SITC of CAT 6, 24 port Loaded Patch Panel with accessories.
SITC of CAT-6 Patch Cord - 1 meter (at n/w rack side)
SITC OM4 50/125µm, Internal Riser Distribution Cable, OD 6mm, ULSZH, 6 core fiber (2 runs from core switch configured on 3rd floor server room)
SITC of fully loaded 12 port LIU (12 x LC OM4 Duplex Adaptors (24F), 24 x OM4 LC Pigtails. 24 x Splice protectors. Splice trays (2) and cable glands)
Patch cord, OM4, LC, 2F, 2.0m
WiFi ACCESS POINT
SITC of Wi-Fi Aps HPE Aruba Networking AP-515 (RW) Dual Radio 4x4/2x2 802.11ax Internal Antennas Unified Campus AP( Details in annexure 1)
NETWORK RACK & ACCESSORIES
Supply & installation of 15U 600 X 800mm (D) Floor/Wall mount double section Rack with Front Glass Door, Fan Tray on Top (4nos.), Perforated Rear Doors, Openable Entry at the Bottom for the Cable entry, Casters, 5 nos. Fixed shelf, Cable Basket/ manager for Cable Dressing - 4 nos & 1 No Horizontal Power Strip with 5/15 A Universal Sockets (having both flat and round pin), hardware & accessories to mount the passive & active equipments.
CABLES & CONDUITS
Supply, laying & testing of Cat 6 UTP cable including labelling and end termination with connectors both end.
Supply & Installation of HMS 25 mm dia, FRPVC conduit including all accessories e.g. deep junction box, bends etc. for concealing in slab / wall & spacer saddles for open on slab / wall. Colour - Grey
Access Control System
Card & Card Readers
Supply, installation, testing & commissioning of Multi Technology Card Reader (Proximity / Mifare / Smart Card / Bluetooth/ Biometric) Should be capable of reading multi-format cards, bluetooth and NFC. Support OSDP, Should have encrypted communication to the controllers. Should have read range of atleast 5 cms with access cards even when the bluetooth option of reader is enabled. complete with mounting box, plate & required accessories. (only bluetooth hardware to be considered)
Hardware & Controller
Supply, installation, testing & commissioning of Access Door Controllers controlling 4 doors (4 Readers) with minimum 4 Monitor inputs, 4 Relay outputs suitable for EM Lock & Swing barrier integration, 4 Exit switch button inputs, Fire trigger inputs, shall have build in onboard Ethernet (TCP / IP) port, Capable of storing 250,000 cards capability & 99,999 Transactions log. complete with power coated Encloser, Power supply unit, in-built Battery backup for 4 hrs & required accessories. Note - Integration with Elevators Controller (E-Lip software) & Lift Display unit on TCP/IP network or any other protocal including hardware connection are also included in scope. Vendor should carryout sample test before submitting offer & technical approval of ACS controller.
Supply, installation, testing & commissioning of surface mounted Electro Magnetic single door locks With Feedback having capacity of holding force of 600/1200 lbs with Armature plate, mount brackets & required accessories.
Supply, installation, testing & commissioning of Exit Switch Button (Bell push type) with mounting back box, plate & accessories.
Cables & Conduit
Supply, Fixing, Testing and Commissioning of 8C x 1.00 Sq.mm. FRLS, Flexible, Shielded with Aluminium Mylar tape, ATC multi stranded conductor Cable with required accessories. (Colour: Grey) for Reader
Supply, Fixing, Testing and Commissioning of 4C x 1.00 Sq.mm. FRLS, Flexible, Shielded with Aluminium Mylar tape, ATC multi stranded conductor Cable with required accessories. (Colour: Grey) for EM Lock
Supply, Fixing, Testing and Commissioning of 2C x 1.00 Sq.mm. FRLS, Flexible, Shielded with Aluminium Mylar tape, ATC multi stranded conductor Cable with required accessories. (Colour: Grey) for Exit switch
Supply, laying & testing of Cat 6 UTP cable including labelling and end termination with connectors both end. From controller to switch
Supply & Installation of HMS 25 mm dia, FRPVC conduit including all accessories e.g. deep junction box, bends etc. for concealing in slab / wall & spacer saddles for open on slab / wall. Colour - Grey
ACTIVE COMPONENTS
PASSIVE COMPONENTS
CABLES & CONDUITS
Broadband Coax, Series 11, 14 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, Aluminum Braid Shielding, PE Jacket, Waterblocked
Broadband Coax, Series 6, 18 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, Aluminum Shielding, PVC Jacket
MGPS BOQ
Miscellaneous items
Supply, Installation, Hook up, Testing , Commissioning Zone Alarm Panel Touch screen (tender makes only), NFPA 99 compliant, located in each wing of each floor, to give view of services of a). Med Air4 b). Med Vacccum c). Med Oxygen . The factory shall be panel shall be NFPA 99 compliant, floor mounted mounted in corrosion proof enclosure. The gas labels shall colour coded by gas type-service parameter-unit - Normal/Alarm (Lo&Hi)-Location. Panel indicators shall be Power On & Normal, System Fault warning, Each self test, Mute for 80 dBA Audible & Visual alarm, field programmable & readily connectible to Central Alarm Panel through 4-20mA/Potential free contacts. As per tender technical specifications
Supply/ Installation/ Testing/ Commissioing of Medical Gas Distribution Zone / Area Valve Box(tender makes only), NFPA 99 compliant, for local isolation of service distributors on floor, factory made in corrosion proof enclosure with hinged temper proof door in 18 swg 1 coat of surface tolerant primer & 2 coat of polyurathene with marine grade heat resistance thickness having opaque door with pull ring & gauge window complete with gas labels & pressure/ vacuum gauges. As per attached Tech Specs & Layout drawings for valves sizes
Supply, Installation, Testing, Commissioing of Medical Gas Isolation valves (tender makes only), bare on line, NFPA 99 compliant, High tensile bronze/ brass 4 bolt bronze body double seal union ball type with TFE/ Viton seal 400 psig isolation valves with K type pipe stubs-Medical Grade Copper pipe for fixing in the Floor Local Zone Valve box,Area Valve Boxes, Bare for wards in HWCC building As per tender technical specifications
Supply, Installation, Testing, Commissioing of as per NFPA 99 Level 6020 Medical Grade Gas distribution piping (tender makes only) manufactured from phophorpus deoxidized non arsenical copper to BS EN 1412:1996 grade CW024A manufactured to metric outside diameters having mechanical properties in accordance with BS EN 13348:2008-R250 half hard for sizes up to 54 mm or BSEN 133348:2008-R290 fro larger sizes in ready made built up trenches as per applicable standard, open execution on internal / external walls, in vertical shafts, above false ceilings as also inside removable trunking, in walls by chasing cutting compelete with factory made fittings such as tee/ elbow/ crossover/ wall sleeves etc., complete with vertical & horizontal supports and termination at both ends, colour coded painting etc. As per tender technical specifications
12mm ID x 0.7 mm thick
15 mm ID x 0.9 mm thick
22mm ID x 0.9 mm thick
28 mm ID x 0.9 mm thick
35 mm ID x 0.9 mm thick
42 mm ID x 1.2 mm thick
54 mm ID x 1.2 mm thick
76 mm ID x 1.5 mm thick
108 mm ID x 1.5 mm thick
Supply, Installation, Testing, Commissioing of Medical Gas specific terminal Outlets (tender make only) , NFPA 99 compliant,geometric quick fix type for breathing air/surgical air/medicall vacuum/medical oxygen complying & matching with correct medical gas probe according to the gas service outlets to be fitted in bed head panels. As per tender specifications
In Bed Head Panel
Medical Oxygen
Medical Air
Medical Vaccum
Supply, Installation, Testing, Commissioing of Vacuum Unit complying with ISO100793 :2000 for ward areas consisting of 0-760 mbar vaccum regulator, vaccum filter & 1000 ml vacuum collection jar made from polycarbonate/ polysulphone material As per tender technical specifications
Supply, Installation, Testing, Commissioing of Oxygen flow meters with humidifier bottle complying with ISO 15002:2008 range of 0-15 LPM, 3-5 psig humidifier setting As per tender technical specifications
Supply, Installation, Testing, Commissioing of Hi pressure antistatic medical hoses colour coded in respect of each gas as per ISO standard As per tender technical specifications
Supply, Installation, Testing, Commissioing of Low pressure silicone tube medical hoses colour coded in respect of each gas as per ISO standard As per tender technical specifications
Supply, Installation, Testing, Commissioing of Bed Head Panel Extruded Aluminum 3 mm thick sheet, duly rendered resistant to UV/ Chemical/ Corrosion/ Pollution resistant, while Surface mounted housing conforming to NFPA 99 standard suitable for fixing gas outlets, power socket & switch modules with identified colour , nurse call button complete with barrier between gas & power section etc. complete with Rails, IV Pole,Document basket, Monitor tray , LED luminaire with switch etc. As per tender technical specifications
Non Intensive Type I
Horizontal – 2*O2+2*Vac gas outlets, 2 sets of 2*5/15A nos universal switch socket ,1*ELCB, 1*Tel,1*LAN,1*Nurse Call Module
Supply,Installation,Testing,Hookup, Commissioing of Dummy runners will be of modular design and shall be made inextruded aluminium profiles, which can be assembled together toform each of different models catered for different applications. The lengths of the units are customizable to suit different requirements and can be joined to form extended lengths for multiple beds layout.The units will be of surface mounted type and the front covers shall be of modular design for ease of installation and maintenance on site. All screws or fasteners will be hidden for easy cleaning. Material :- Extruded Aluminium Grade:- ALU 6063 T5 Surface Finishing:-Power Coating Color:-off-White (Standard) L x W x D :-Customizable X 200 mm X 65 MM
SD INTERBUILD (INDIA) PRIVATE LIMITED (BID ID -3287521)
Eagle Infra India Ltd (BID ID -3284725)
SHAH EPC SERVICES AND PROJECTS PVT LTD (BID ID -3274951)
ADARSH INFRAINTERIO PVT LTD (BID ID -3279928)
Skyway Infraprojects Pvt. Ltd. (BID ID -3300319)
Kaishar Interiors Pvt Ltd (BID ID -3294057)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.77 MB
MEP.rar
Additional Documents • 16.11 MB
TD.pdf
Tender Documents • 2.71 MB
Civil.rar
Additional Documents • 15.43 MB
CivilTechSpecs.rar
Additional Documents • 7.40 MB
MEPTechSpecs.rar
Additional Documents • 7.78 MB
AnnexureForm.xls
Additional Documents • 0.12 MB
MEP2.rar
Additional Documents • 10.04 MB
BOQ_918343.xls
BOQ • 0.74 MB
Download all tender documents and submit your bid