Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC HOUSE NO 142 GALI NO 07 PREM VIHAR NANGLI SAKRAWATI NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | ₹23.9 L Quoted ₹25.0 L | L1 | Accepted-AOC Accepted due to lowest rate quoted |
| 2 | L2₹25.1 L+₹10,446.80 (0.42%)Rejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹25.1 L+₹10,446.80 (0.42%) | L2 | Rejected-Finance Rejected due to highest rate quoted |
| 3 | L3₹25.8 L+₹78,237.80 (3.13%)Rejected-Finance | ₹25.8 L+₹78,237.80 (3.13%) | L3 | Rejected-Finance Rejected due to highest rate quoted |
| 4 | L4₹28.4 L+₹3.4 L (13.5%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹28.4 L+₹3.4 L (13.5%) | L4 | Rejected-Finance Rejected due to highest rate quoted |
| 5 | L5₹36.9 L+₹11.9 L (47.6%)Rejected-Finance | ₹36.9 L+₹11.9 L (47.6%) | L5 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | sheetal engineering L3 | M/S Anand Enterprises L4 | Ridhi engineers and builders L7 | M/s.sagar enterprises L5 | M/S LADPURIA ENTERPRISES L6 | S K ENGINEERS AND CONTRACTOR L1 | M/S PARKASH ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for attending complatints of street light, flood light,high mast light mounted at any height in pole/hanger in domestic and tech area of AFS Rajokri and connected road light by checking connection , serviceability of fittings, SMC boxes , MCB, thimbles or any other minor fault complete all as specified and directed. Note- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra as and when required or any other T&P, Grese for attending complaints of Hanger light/high mast light shall be done by contractor.(c) Complaints shall be rectified with in 24 Hours.if contractor fails to attend the complaints a recovery of Rs 500 per day shall be deducted from payment due to contractor(e) Weekly inspection of all security lights/street lights of area under AFS Rajokri shall be carried out and report shall be submitted to Engr-in-chage without any delay. | 2,000 | Each complaint | 33 ₹66,000 | 20 ₹40,000 Lowest | 250 ₹5,00,000 | 50 ₹1,00,000 | 80 ₹1,60,000 | 41 ₹82,000 | 50 ₹1,00,000 |
| 2.00 | Supply and fixing in rerplacement LED type street light 35 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. | 35 | Each | 1,300 ₹45,500 Lowest | 1,500 ₹52,500 | 1,850 ₹64,750 | 1,800 ₹63,000 | 1,400 ₹49,000 | 1,400 ₹49,000 | 1,300 ₹45,500 Lowest |
| 3.00 | Supply and fixing in replacement LED type street light 60 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed. | 100 | Each | 1,500 ₹1,50,000 Lowest | 1,500 ₹1,50,000 Lowest | 2,500 ₹2,50,000 | 2,000 ₹2,00,000 | 2,100 ₹2,10,000 | 1,600 ₹1,60,000 | 1,500 ₹1,50,000 Lowest |
| 4.00 | Supply and fixing in replacement LED type street light 90 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. | 100 | Each | 2,300 ₹2,30,000 | 1,800 ₹1,80,000 Lowest | 2,850 ₹2,85,000 | 3,500 ₹3,50,000 | 2,700 ₹2,70,000 | 1,800 ₹1,80,000 Lowest | 2,500 ₹2,50,000 |
| 5.00 | Supply and fixing in replacement LED type flood light 70 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 20 | Each | 2,100 ₹42,000 | 2,000 ₹40,000 | 3,500 ₹70,000 | 2,500 ₹50,000 | 2,000 ₹40,000 | 1,990 ₹39,800 Lowest | 2,400 ₹48,000 |
| 6.00 | Supply and fixing in replacement LED type flood light 100 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 20 | Each | 2,500 ₹50,000 | 2,500 ₹50,000 | 3,500 ₹70,000 | 2,700 ₹54,000 | 2,600 ₹52,000 | 2,190 ₹43,800 | 1,900 ₹38,000 Lowest |
| 7.00 | Supply and fixing in replacement LED type flood light 120 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 30 | Each | 3,300 ₹99,000 | 2,800 ₹84,000 | 3,500 ₹1,05,000 | 4,700 ₹1,41,000 | 3,000 ₹90,000 | 2,100 ₹63,000 | 2,000 ₹60,000 Lowest |
| 8.00 | Supply and fixing in replacement LED type flood light 250 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. | 20 | Each | 3,999 ₹79,980 | 6,000 ₹1,20,000 | 4,500 ₹90,000 | 6,500 ₹1,30,000 | 4,500 ₹90,000 | 3,190 ₹63,800 Lowest | 7,000 ₹1,40,000 |
| 9.00 | Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500k (warm white or cool day white as per site requirement), inbuilt surge protection = 5 Kv, 50000 Hrs burning hours including gountong of light grade pipe of suitable length on post complet all as specified and directed.. | 20 | Each | 2,300 ₹46,000 | 2,500 ₹50,000 | 9,900 ₹1,98,000 | 5,500 ₹1,10,000 | 3,800 ₹76,000 | 2,200 ₹44,000 Lowest | 2,900 ₹58,000 |
| 10.00 | Supply and fixing in replacement LED Bollard 8 watt 230 watt volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500K/3000K as required at site, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. Note- (1)Earth work and PCC shall be included in quoted rate.(2) Model and design shall be finalized by dept. | 40 | Each | 1,700 ₹68,000 | 2,000 ₹80,000 | 3,500 ₹1,40,000 | 2,500 ₹1,00,000 | 1,900 ₹76,000 | 1,500 ₹60,000 Lowest | 2,000 ₹80,000 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
20 Oct 2025, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR AND MAINTENACE OF DG SETS SECURITY LIGHTS EARTHING INFRASTRUCTURE AND OTHER ALLIED WORKS AT AF STN RAJOKRI UNDER GE (AF) GURGAON
2025_MES_730649_2
GE/GUR-/NIT-63/2025-26
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹94,000
8 Dec 2025
3 Oct 2025
22 Oct 2025
3 Oct 2025
20 Oct 2025
13 Oct 2025
Amount
M&L for attending complatints of street light, flood light,high mast light mounted at any height in pole/hanger in domestic and tech area of AFS Rajokri and connected road light by checking connection , serviceability of fittings, SMC boxes , MCB, thimbles or any other minor fault complete all as specified and directed. Note- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra as and when required or any other T&P, Grese for attending complaints of Hanger light/high mast light shall be done by contractor.(c) Complaints shall be rectified with in 24 Hours.if contractor fails to attend the complaints a recovery of Rs 500 per day shall be deducted from payment due to contractor(e) Weekly inspection of all security lights/street lights of area under AFS Rajokri shall be carried out and report shall be submitted to Engr-in-chage without any delay.
Supply and fixing in rerplacement LED type street light 35 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.
Supply and fixing in replacement LED type street light 60 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.
Supply and fixing in replacement LED type street light 90 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.
Supply and fixing in replacement LED type flood light 70 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement LED type flood light 100 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement LED type flood light 120 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement LED type flood light 250 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500k (warm white or cool day white as per site requirement), inbuilt surge protection = 5 Kv, 50000 Hrs burning hours including gountong of light grade pipe of suitable length on post complet all as specified and directed..
Supply and fixing in replacement LED Bollard 8 watt 230 watt volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500K/3000K as required at site, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. Note- (1)Earth work and PCC shall be included in quoted rate.(2) Model and design shall be finalized by dept.
S&F in replacement of PVC SMC boxes with hinged door fixing of size 333mmx233mmx120 mm with MS clamp made to shape with necessery nut bolts and washers complete comprising of Aluminium busbar 63 Amps capacity of suitable size mounted over porcelain insulator withMS clamp nut bolts & washers incl MCB 6 Amps and making incoming and outgoing connections by taking out loops of cable of any size incl necessary excavations and other civil works all as specified and directed. Make- 1.Sintex 2.Universal 3.SMS
S&F in replacement LED rope light tri colour light saffron/white/green 8 watt per meter capacity capacity 120 no of LEDS with 15 RM legth with IP 65 Protection wrapped around poles of any length , height location and connection to electric cable/wire with the help of ladder/hydra as per site requirement complete all as specified and directed. Make- orient,havells,Bajaj
S&F in Rep/Replacement of cable PVC insulated unarmored for connection 2.5 Sqmm 3 core copper conductor duly drawn from junction box to street light fitting on poles in heavy duty rigid PVC conduit pipes complete all as specified and directed. MAKE- 1. Havells 2.Finolex 3.wipro
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of poles with one coat of primer and two coats of aluminium paint of approved make incl writing pole nos on white backgrounds with black paint , complete all as specified and directed.
M&L for painting the surface of PCC poles of any size with one coat of primer and two coats of appex exterior paint of approved make incl writing pole nos on white backgrounds with black paint complete all as specified and directed.
S&F in replacement of existing unserviceable driver circuit with new one of any make or any model on existing LED street light fittings of wattage 45 to 120W complete all as specified.
S&F in replacement of existing unserviceable driver circuit with new one of any make or any model on existing LED Flood light fittings of wattage 60 to 200W complete all as specified.
S&F in replacement of existing unserviceable surge protector with new one of any make or any model on existing LED street/Flood light luninatrie of wattage 45 to 200W complete all as specified.
M&L street light bracket made out from GI Pipe 32 mm bore, light grade, 1.2 m long bent to shape including fixing 02 set of clamp made out from MS Flats of size 25x5 mm complete with nuts and bolts and washers of suitable size duly painted with two coats of aluminium paint over a coat of red oxide primer all as specified and directed .
S& Laying XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with standard aluminium conductor of size 25 Sqmm 4 core all as specified and directed.
S& Laying XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with standard aluminium conductor of size 10 Sqmm 4 core all as specified and directed.
S&F in replacement of timer switch for security light duly steel enclosed with locking arrangement fixed to wall/pole / existing panel by means of clamp.nut,bolt washers or by welding including following items-(a) MCCB 63 A 16 KA 4 Pole-01 Nos,(b) MCB SPN 16-40 Amp - 01 Nos, (c) Power Contactor ML3 40Amp , 3 Pole- 01 No, (d) Time switch analog dial type - 01 Nos, (e) Bypass arrangement for testing/repair of light.
Supply and fixing in replacement LED aviation light 10 watt duly enclosed in die cast aluminium casting with Red polycarbonate dome for better illumination, Integral driver , Supper flux 5mm 302nos LEDs incorporated with Ingress Protection : IP65, Protection against short-circuit, Protection against surge, Wide operating input voltage range 100 – 270VAC,burning hr 50,000Hrs.complete all as specified and directed.
M&L for testing the earth resistance value of any type of earthing such as chemical conventional in any location with the help of IS 9223 certified earth resistance meter by using three point/ fall of potential/star delta method as directed complete all as specified and directed by Engr-in-Charge. Note-(i) Earth test shall be carried out quaterly and report shall be submitted to Engr-in-Charge.(ii) Contractor has to provide caliberated Earth test meter.
M&L in replacement for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L in replacement Aluminium strip 25X3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and base insulators complete all as specified and as directed.
M&L in replacement GI strip 32X6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and base insulators (porcelain /PVC/rubber) complete all as specified and as directed.
M& L in replacement for earth continuity conducted or main earthing lead fixed to wall/ceiling on batten or recess or chases or buried in ground or drawn in conduit/pipe or other directed situation for earthing etc as required 20x3 copper strip all as specified and directed.
S&F in replacement SMC/DMC insulator for seperation of earth strip from wall /ceiling including fixing aceessoriese such as nut bolt etc complete all as specified and directed.
M&L in repair/replacement for Earthing to machinary with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth strip of size 32x6mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 40 mm dia medium grade and connected to machinary including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
supply and replace of maintanance free unserviceable battery 12 V, 120 AH with initial charging and testing compleete all as specified and as directed. Make: Amaron/Exide/Microtek.
supply and replace of maintanance free unserviceable battery 12 V, 90 AH with initial charging and testing compleete all as specified and as directed. Make: Amaron/Exide/Microtek.
Maintenance / repairs to AMF panels, by skilled technician and replacement of unserviceable spares as specified below for capacities up to 250 KVA DG set including replacement of controle wiring with FRLS copper conductor cables with appropriate gauge and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified power factor all as specified and directed at site.
Supply in replacement only electronic timer any type for 0 to 10 Sec (on Delay)
Supply only in replacement electronic timer any type for 0 to 60 Sec (off Delay)
supply only in replacement Power contactor MNX 35
supply only in replacement Power contactor MNX 70
supply only in replacement Power contactor MNX 110
Supply only in replacement starting relay with sequence timer and master timer
Supply only in replacement Under voltage relay
Supply only in replacement over voltage relay
M&L for repaire/replacement of battery charger for AMF panel with existing Capacity complete all as specified and directed by Engr-In-Charge.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed by EIC.
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole or similar works complete all as specified and directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete for fixing of pole complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for copings of poles/stay/panels complete all as specified and directed.
Supply and erect true vertical steel tubular swaged pole confirming to IS-2713 part-II 410 SP-31 ,9.0 meter long complete with MS base plate of 6 mm thick of size 300x300 mm , finial taper plug, cap , bolt, nuts, eashers including painting externally with two coats of aluminium paint over a coat of red oxide primer for exposed portion and two coats of black bituminious paint for embeded portion in concrete as well as throughout internally including povision of white and blue colour strips with fluorescent paint upto 1.5 mtr height and numbering of pole complete all as specified and directes by engr-in-charge.
M&L for rewinding of motor of 5 hp capacity installed at High mast light complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
Returning, filling in including spresding leveling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
M&L for laying or grouting GI pipes 50 mm dia medium grade for cable protection in trenches / poles or mounting gate/garden light complete all as specified and as directed.
S& F in replacement of Solar Street Light fitting 20 watt all in one made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light, which increases the backup time complete all as specified and directed.
Supply and installation in replecement of Hot dipped Octagonal galvanized iron pole 8 mtr height, SMC/DMC Insulator and busbar for three phase a cable connection and MCB SP 6 Amp duly enclosed in pole with cover and cover shall be connected with metal chain, nut bolt for its proper sealing with necessary Foundation RCC 1:1:5:3 with 8Nos.16 mm dia tor bar as main bars and 8mm dia.Tor bars strips@190mm c/c as this reinforcement shall confirm to IS : 1786 latest edition.The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia,PVC sleeve cast foundation for cable entry,Excavation,RCC and reinforcement etc as per manufacturer recommendation and the cost of necessary foundation , steel bars , strip and pole top mounted bracket (single or double as per site requirement and directed ) as per Manufacturer instructions complete all as specified and as directed by Engr-in-charge.
M&L for refilling Diesel exhaust fluid (DEF) suitable for CPBC IV Generatoe set . The DEF shall be supplied in sealed container of 20 ltrs complete all as specified and directed
M&L for overhauling of trolley suitable to mount DG set by performing following Tasks. (a) Greasing of all mecahnical parts of trolley.(b) Painting of all metallic parts by applying two coats of synthetic enamel paint paint over a coat of primer of trolley.(c ) Welding of broken metallic parts.(d) Replacement of bush and bearing of trolley wheels. (f) Replacement of all tyres of including their tubes. (g) Any repair work required to make the trolley functional.(h) Repairing of leaf spring.
M&L for inspection , servicing and repair of DG sets 100 KVA capacity with B check by authorised service engineers of manufactureres of the following capacities including minor repairs and replacement of worn out spares such as fuel filter, hose pipes, injector nozzles, cut out, electrical wiring, self starter, dynamo / alternator and tightening of nut bolts, washers, changing of lubricating oil, etc; complete including testing on load all as directed by performing following tasks (a) S&F in repair lubrication of oil filter.(b) S&F in repair by pass filter.(c) Cleaning of hydraulic governer.(d) S&F Checking and toping up of coolant.(e) S&F in repair fuel filter.(f) S&F in repair air cleaner element. (g) Cleaning of radiator complete set.(h) Engine oil as per manufacturer specification and any other checking as per manufacturer instruction.
All as per item No 60 here in before but 62.5 KVA DG Set Make - Kirloskar complete all as specified and as directed by Engr-in-charge.
All as per item No 60 here in before but 10/20/25 KVA DG Set Make - Kirloskar complete all as specified and as directed by Engr-in-charge.
All as per item No 60 here in before but 250 KVA DG Set Make - Kirloskar complete all as specified and as directed by Engr-in-charge.
S&F Solenoed switch suitable for upto 100 KVA DG Set complete all as specified and as directed by Engr -in-charge.
S&F in repair ring gear of flywheel suitable for DG set upto 100 KVA complete all as specified and as directed by Engr-in-charge.
S&F in replacement of AVR VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set upto 100KVA complete all as specified and as directed by Engineer -in-charge.
M&L for disconnection and opening of self starter assemlly 12/24 volt for repair from DG set upto 100 KVA and repair unserveceable part of self starter suitable size as required on site complete all as specified and directed. Note:- Rate are deemed to be include all worn out part including gear and winding complete all as specified and as directed by Engr-in-charge.
M&L for discaling of cooling system of DG set upto 100 KVA by radiwash with two times circulation of rediwash by means of running of engine and cleaning of fan blades, crakcase breather, radiator and its fins by means of high pressure air or water complete all as specified and as directed by Engr-in-charge.
Supply only the following items of DG Set of various capacity complete all as specified and as directed by Engr-in-charge :-
(a) Battery terminal, lug, bolts type suitable for heavy duty battery 12/24 V.
(b) Battery leads for copper conductor multiwired 35 Sqmm.
(c) Hinges for DG set door of any size, any type as required on site.
(d) Servo cool plus Radiator coolent.
(e) Low viscosity synthetic Engine oil 15W40.
Dismantling existing U/S battery charger and S&F of SMPS type battery charger suitable for 12V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG set is not in use complete all as specified and as directed by Engr-in-charge.
S&F 'V' belt for fan pulley (set of 2 Nos) for DG set upto 100 KVA complete all as specified and as directed by Engr-in-charge.
S&F 'V' belt for alternator and water pump assembly for DG set upto 100 KVA complete all as specified and as directed by Engr-in-charge.
S&F fuel hose pipe from fuel filter to fuel pump for DG set upto 100 KVA complete all as specified and as directed by Engr-in-charge.
M&L for cleaning of fuel tank to DG Sets emptying the fuel carefully and removing all sedimented particles including scales using wire brushes and kerosene inculding replacement of worn out transparent fuel level indicating tube inculding necessary fixing arragements and marking fuel levels on the tank using white synthetic enamel paint all as specified and directed for following capacity of DG Sets:-
(a) 100KVA capacity
(b) 250 KVA Capacity
(c) 62.5 KVA Capacity
(d) 10/25/20 KVA Capacity
Supply and fixing in replacement, radiator assembly complete including all accessaries such as radiator core comprising copper tubes, fins, upper and lower tanks, radiator frame, inlet and outlet pipes, radiator cap etc,complete all as directed for capacity. Make - Kirloskar.
(a) 100KVA capacity
(b) 62.5 KVA Capacity
(c) 10/25/20 KVA Capacity
S&F fuel pipe from fuel tank to fuel filter for DG Set upto 100 KVA complete all as specified and as directed by Engr-in-charge.
S&F in replacement of 63 to 160 Amps, 415V, 50 Hz, MNX Power contactor of coil voltage 240V complete all as specified and as directed by Engr-in-charge.
M&L for attending of any breakdown of standby power supply in any location, whenever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature ie engine, alternator, control panel/AMF pael etc complete all as specified and as directed by Engr-in-charge. Note- (i) The cost of replaced spare parts will be paid and measure seperatly. (ii) If complaint is not attended by contractor with in five hours the penalty of Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile No who will receive the complaint round the clock.
M&L for opening/taking out of injector of DG set of any type/capacity /make upto 100 KVA disconnection and opening of fuel injector assembly carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit including calibration of injector , checking the allignment and making proper fuel connector and testing for smooth operation complete all as specified and as directed by Engr-in-charge.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set commection testing complete all as specified and as directed by Engr-in-charge.
M&L for complete overhauling/servicing of turbo charger, opening/taking out of turbo charger of DG set upto 100 KVA capacity, disconnection of air supply connection pipe etc including replacement of turbo charger repair kit, calibration testing of turbo charger system complete and re-assembling the same fitted with DG set properly in original position, checking the allignment and making all connection, testifng for smooth operation from authorised rep or service engineer from the manufacturer complete complete all as specified and as directed by Engr-in-charge.
Supply only conventional type 4 wire , 3½ digit LCD display which can measure Earth resistance / Earthing measurement instrument ranges of 0.01 ohm to 1999 ohm with rechargeable internal Ni-MH battery . It is certified as per IS-9223. Make: shanti, motwane.
Supply only digital type multimeter LCD display which can measure current , voltage and conituity with inbuilt buzzer sound with IEC 61010 complete all as specified and directed. Make: Fluke 302 plus or equivalent.
supply only Highly insulated FRP Earth/Discharge rod of assembled height 15ft in section 03x5ft height. Die cast alu. Grounding "C" clamp. ISI marked PVC insulated multi-stranded 440/11000V grade transparent copper cable 35sq.mm (length 25ft) as per IS-694.
M&L for carrying out horizontal boring below roads/PCC hard sanding/Drains all as specified as directed for inserting GI pipe of the following sze with a depth upto 1.5m & length of road upto 12 m of the suitable for 40 & 80 mm dia GI pipe
S& Laying XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with standard aluminium conductor of size 6 Sqmm 2 core all as specified and directed.
M/S PARKASH ENTERPRISES (BID ID -3460111)
sheetal engineering (BID ID -3454837)
M/S Anand Enterprises (BID ID -3455406)
M/s.sagar enterprises (BID ID -3460789)
M/S LADPURIA ENTERPRISES (BID ID -3460820)
Ridhi engineers and builders (BID ID -3455721)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments63.pdf
Tender Documents • 0.45 MB
BOQ_821444.xls
BOQ • 1.09 MB
CorrigendumBOQandDate.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .