| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.5 L+₹6.2 L (21.8%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹35.4 L+₹7.1 L (24.9%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹36.8 L+₹8.5 L (30.0%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹38.7 L+₹10.3 L (36.5%)Rejected-Finance TULSI ASTHA FLAT NO 1 PLOT NO 54 SECTOR 12 VASHI NAVI MUMBAI THANE 400 703 | THANE | MAHARASHTRA | 400703 | L5 | Rejected-Finance BEING L5 |
Tender Value
₹32.3 L
EMD Value
₹64,600
Closing Date
22 Feb 2021, 6:00 pmClosed
GE AF THANE
Kolshet Road,Sandoz Baugh post,Thane 400607
PROVISION OF CERTAIN B/R AND E/M SANCTIONED MAJOR REVENUE ,SPECIAL REPAIR AND MINOR WORKS AT AT SITE P UNDER GE (AF) THANE
2020_MES_400054_3
8976/E8
Open Tender
Civil Works - Others
Item Rate
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹64,600
Yes
9 Mar 2021
16 Feb 2021
23 Feb 2021
16 Feb 2021
22 Feb 2021
16 Feb 2021
16 Feb 2021 - 16 Feb 2021
Amount
Demolition of cement concrete (unreinforced) of any description and in any position provided as in roof padding, roof curb etc,complete all as specified and directed by Engr-in-charge. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place as directed by the Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil ,complete all as specified and directed by Engr-in-charge.
Surface dressing n.exc 15cm deep in soft/loose soill ,complete all as specified and directed by Engr-in-charge.
Excavation in trenches n,exc 1.5m depth and 1.5m width for foundation n.exc 10 sqm on plan and n.exc 1.5m depth getting out in Soft/loose Soil,complete all as specified and directed by Engr-in-charge.
M&L for Plain Cement concrete ,type D-2 (1:4:8) using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete complete all as specified and directed by Engr-in-Charge.
M & L for TMT bars 10 mm dia and over, cut to length bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips ,quality confirming to TMT bars ,complete all as specified and directed by Engr-in-Charge.
M & L for TMT bars for 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips ,quality confirming to TMT bars ,complete all as specified and directed by Engr-in-Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) on flat rough finished surface of concrete , complete all as specified and directed by Engr-In- Charge
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc on Flat rough finished surface of concrete ,complete all as specified and directed by Engr-In- Charge
M&L for Reinforced cement concrete (nominal mix) in type B-1 (1:2:4) (using 20mm graded crushed stone aggregate) as in slabs supporetd on walls, beams and columns in floors, roofs,landings, balconies, canopies, deck slabs and in shelves and the like ,complete all as specified and directed by Engr-In- Charge
M&L for Reinforced cement concrete (nominal mix) in type B-1 (1:2:4) (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span ,complete all as specified and directed by Engr-In- Charge.
M&L for Pre-cast cement concrete block masonry 1:3:6 Type C-1 (using 20mm stone graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed by Engr in Charge
Material and labour for 15 mm thick plaster in cement mortar (1:4) in two layers, i.e 10mm thick in bottom layer & 5 mm in top layer mixed with integral water proofing compound as per manufacturers instruction on brick or concrete surfaces of wall finished fair and even ,complete all as specified and directed by Engr-In- Charge. Note :- Water proofing compound shall be measured and paid separately under relevent item of Sch 'A'.
Supply only integral water proofing compound ,complete all as specified and directed by Engr-In- Charge.
M&L for rendering 10mm thick in CM 1:6 finished even & smooth with sagol finish to internal surfaces , complete all as specified and directed by Engr-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing as mentioned is SSR Part-II, complete all as specified and directed by Engr-in-charge.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing as mentioned is SSR Part-II, complete all as specified and directed by Engr-in-charge.
S&F Anodised aluminium window and ventilator shutters, fixed type with out sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc , complete all as specified and directed by Engr-in-charge.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sq.m in each pane , complete all as specified and directed by Engr-in-charge.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, in any type of soil, complete all as specified and as directed.
S&F coloured non skid ceramic tiles (square/rectangular) area of each tile exceeding 0.11Sqm but n.exc 0.18 Sqm,in floors set and jointed in neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:4 ,complete all as specified and as directed by Engr-in charge.
M&L for medium grade G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors, complete all as specified and directed by Engr-in-charge.For the following sizes:-
For 15mm bore dia
For 20mm bore dia
S&F Bib tap, for 15mm Bore dia of pipe, cast copper alloy cromium plated with crutch or butterfly handle , fancy type ,screwed down, screwed for iron pipe or for brass ferrule , complete all as specified and directed by Engr-in-charge.
S & F Stop valves, for 15mm Bore dia of pipe, , cast copper alloy cromium plated, screwed down, high pressure, with crutch or butterfly handle ,fancy type screwed both ends for iron pipe or for unions and fixed , complete all as specified and as directed by Engineer-In-Charge.
S&F Pillar tap ,for 15mm Bore dia of pipe, cast copper alloy chromium plated, with capstan heads, , screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed fancy type , complete all as specified and as directed by Engineer-In-Charge.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed , complete all as specified and as directed by Engineer-In-Charge.Of the following sizes:-
Of 20mm dia
S&F PVC connections 15mm size with PTMT nuts of length with brass connector as mentioned below , complete all as specified and as directed by Engineer-In-Charge.
Of length 600mm long
S&F Brass Cromium plated Towel rail of 20 mm dia, D type , and 60 cm long , complete all as specified and as directed by Engineer-In-Charge.
S&F Wash basins, Vitreous China (flat back or angle back type) size 600x480mm, including cutting for and pinning in ends of brackets or erecting stand but inclusive of fixing and supply and waste pipe of 32 mm dia, taps,chain and plug and porcelain stopper and including brackets , complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 10mm thick in CM 1:3 as in ceiling , complete all as specified and as directed by Engineer-In-Charge.
S & F Vitreous China WC (Pedestal pattern white) including fixing bolts with PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 ltr capacity, seat cover black closed pattern with flat bottom, and mild steel chromium plated and flush pipe PVC 32mm dia for low level cistern , complete all as specified and directed by Engr-in-charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white including seat and cover, connection to trap, and to flushing pipe, antisyphonage pipe etc complete including making good to floor (excluding fixing bolts, lushing cistern and flush pipe) complete all as specified and as directed
S&F in repair PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern Complete all as specified and as directed by Engineer-In-Charge
S&F in repair vitreous china squatting pan, 'orrisa; pattern, size 580X440mm white, with integral foor rest ( excluding flushing cistern and flush pipe) including seat and cover connection to trap complete all as specified and directed by engineer-in-charge
S&F in repair PVC cabinet mirror of size 550X400X75mm including necessary shelves made of PVC sheets of minimum 5mm thick and mirror fixed on the front side of the shutter complete all as specified and as directed
S&F in repair Vitreous China urinals half stall type including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by Engineer-in- Charge
S&F 500 Ltr Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and , complete all as specified and directed by Engr-in-charge.
S&F low level flushing system plastic valveless syphonic action type white with inlet ball valve float chain and ball (of capacity 10 ltrs ISI marked inck 32mm PVC flush pipe ,complete all as specified and as directed by Engineer-In-Charge.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including seat cover , complete all as specified and as directed by Engineer-In-Charge.
S&F 150 mm extruded aluminium alloy handle , fabricated type, anodised, complete all as specified and as directed by Engineer-In-Charge.
S&F ,in repair ,Wash basins, Vitreous China (flat back or angle back type) size 550x400mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing and supply and waste pipe, taps, waste,chain and plug and porcelain stopper but including brackets complete all as specified and as directed
S&F 20mm Ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed , complete all as specified and directed by Engr-in-charge.
S&F in repair Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed
S&F ,in repair ,Bib taps, fancy type chromium plated, size 15mm, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed
S&F 110 mm bore PVC (SWR)soil, vent and waste pipes,Single socketed, in any length with rubber ring joint, laid in trenches or in floors ,complete all as specified and directed by Engr in Charge..
S&F 110 mm bore PVC (SWR)soil, vent and waste pipes,Single socketed, in any length with rubber ring joint, fixed to walls ,complete all as specified and directed by Engr in Charge.
S&F 110mm bore PVC (SWR) junction single , (single T) equal or unequal ,complete all as specified and directed by Engr in Charge.
S&F 75 mm bore PVC (SWR)soil, vent and waste pipes,Single socketed, in any length with rubber ring joint, laid in trenches or in floors ,complete all as specified and directed by Engr in Charge.
S&F 110mm bore PVC (SWR) junction single , (single Y) equal or unequal ,complete all as specified and directed by Engr in Charge.
S&F 110mm bore PVC (SWR) bends any radius ,complete all as specified and directed by Engr in Charge.
S&F 110mm bore PVC (SWR) vent cowl ,complete all as specified and directed by Engr in Charge.
S&F 110mm PVC (SWR) traps 'P' ,complete all as specified and directed by Engr in Charge.
M&L 75mm PVC (SWR) multi Floor trap, plain with grating including jointing with solvent cement ,complete all as specified and directed by Engr in Charge.
M&L 110mm PVC (SWR) gully trap, including jointing with solvent cement ,complete all as specified and directed by Engr in Charge.
M&L for Preparing new plastered surfaces of wall and applying two coats of acrylic weather coat paint exterior grade over a coat of weather coat primer, complete all as specified and directed by Engr In Charge.
M&L for preparing New plastered surfaces, priming plastered surface over a coat of primer and applying two coats of OBD on walls ,complete all as specified and directed by Engr in Charge.
Removing excavated soil exc 50m and n.exc 250 m and deposited at a level n.exc 1.5m above the starting point ,complete all as specified and directed by Engr in Charge.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m ,complete all as specified and directed by Engr in Charge.
M&L for Hardcore of gauge n exc. 63mm,Broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface ,complete all as specified and directed by Engr in Charge.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. built in cement mortar converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m ,complete all as specified and directed by Engr in Charge.
M&L Sand filling under floors including watering & consolidation complete all as specified and directed ,complete all as specified and directed by Engr in Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed .
M&L for Providing, Plain cement concrete type B1 1:2:4 (using 20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps, coping etc complete all as specified and as directed by Engr-in-charge.
S&F Health Faucet with 8 mm dia one meter long flexible tube and wall hook chromium plated, screwed down, for iron pipe or for brass ferrule (Make :Jaquar ALD-573 ) or equivalent including 2 way cock CP brass complete all as specified and as directed .
S & F swivel shower of Brass Chromium plated of any colour for fixing with 15mm pipe. complete all as specified and as directed by Engineer-In-Charge.
M&L for applying cold bituminous primer @ 0.40litres per Sqm confirming to IS 3384 and laying APP modified polymeric membrane with single central non woven polyester reinforcement not less than 4mm thick and weighing 3.50 to 4.00 kg per Sqm over and including blown type bitumen of grade 85/25 conforming to IS:702 in hot state @1.2 kg per Sqm of surface area, sealing all over laps of 75mm in length side and 100 mm on width side of membrane by torching the same all as per manufacturer's instructions or authorised applicators including rendering 10 mm thick in CM (1:3) including one coat of bituminous aluminium paint complete all as specified and as directed .
Taking down cement plaster of any description on brick walls / Ceiling including raking out joints, hacking for key, scrubbing down with water complete all as specified & as directed.
Taking down chowkhats or frames not exc 1.5 sqm with shutters (without taking off shutters from the frames) complete all as specified and as directed by Engineer-in-charge
Taking down door Chowkat or frames Exc 1.5 sqm but not exc 4 sqm each (without taking off shutters from the frames) ,complete all as specified and as directed by Engineer-in-charge
Dismantling unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises ,complete all as specified and as directed by Engineer-in-charge
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles ,complete all as specified and as directed by Engineer-in-charge
Material & labour for rendering 10 mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished even and smooth (without using extra lime or cement) ,complete all as specified and as directed by Engineer-in-charge .
M&L for Glazed ceramic tiles Coloured and size of tiles 450x350x7mm thick in wall/dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match incl 10mm thick rendering in CM (1:3) ,complete all as specified and as directed by Engineer-in-charge .
M&L for preparaing plastered or unplastered surfaces of old walls, Washing, rubbing down and applying one coat of white wash on ceiling ,complete all as specified and as directed by Engineer-in-charge .
M&L for preparaing plastered or unplastered surfaces of old walls including Washing, rubbing down and applying one coat of Oil bound distemper on walls ,complete all as specified and as directed by Engineer-in-charge .
M&L for Preparation of old steel surfacesof any description over 10cm width & girth not otherwise described and applying one coat of synthetic enamel paint ,complete all as specified and as directed by Engineer-in-charge.
M & L for preparation of old wooden surface of any description over 10cm width & girth not otherwise described and applying one coat of syithetic enamal paint ,complete all as specified and as directed by Engineer-in-charge.
M & L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamal paint over a coat of wooden primer ,complete all as specified and as directed by Engineer-in-charge.
M&L machine cut cudappa stone slab 15-20mm thick over 20mm thick (1:4) CM cement screed base as in jambs and soffits of lintel laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed by Engineer-in-charge
S&F IInd class hard wood plain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints ,complete all as specified and as directed by Engineer-in-charge.
Plain, framed,panelled shutters 35mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats ,complete all as specified and as directed by Engineer-in-charge.
S&F for 35mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or reounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chawkats ,complete all as specified and as directed by Engineer-in-charge.
S&F door sliding bolt aldrop 300mm long aluminum anodised all as specified and as directed by Engineer-in-charge ( Make-classic/Shalimar.)
S&F aluminium anodized barrel tower bolt 150mm long extruded section ,complete all as specified and as directed by Engineer-in-charge.
S&F extruded aluminium alloy handles 100mm fabricated type, anodised complete all as specified and as directed by Engineer-in-charge.
S&F butt hinge of Mild steel 125 mm long ,complete all as specified and as directed by Engineer-in-charge.
S&F Mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate,complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel Surface of any description, n exc 10cm in width or girth and applying two coat synthetic enamel painting over a coat of priming with red oxide zinc chrome when unconnected with other painting or when painted in a different tint , complete all as specified and as directed by Engr-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge.
M&L for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engr-in-Charge.
M& L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base ,complete all as specified and as directed by Engr-in-charge.
M&L for 75mm thick PCC type B- 2, 1:2:4 (40mm graded crushed stone aggregate) as in sub base ,complete all as specified and as directed by Engr-in-charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engr-in-charge
S&F 6mm thick polycarbonate sheet of superior quality in semi circle shape on roof of desired colour and fixed with aluminium metal flat /angle/tee sections including rubber beadings and silicon water proofing sealent for joining the sheet to get required shape ,complete all as specified and as directed by Engr-in-charge.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed by Engr-in-charge.
Dismantling boarding, any description, fixed in any position with nails ,complete all as specified and as directed by Engineer-in-charge
S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605x605mm,complete all as specified and as directed by Engineer-in-charge.
S& F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long ,complete all as specified and as directed by Engineer-in-charge
M&L for Exposed metal frame ceiling with calcium silicate board 6mm thick of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Note:-Frame work for ceiling shall be measured and paid separately under relevent item of Sch A),complete all as specified and as directed by Engineer-in-charge
M&L for Plain Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and as directed by Engr-in-charge
S&F Collapsible steel gates,top hung ,consisting of channel pickets,pivoted flat bars ,top and bottom runners ,brass handle etc as specified errected in position and seuring runners with holdfasts and brackets ,complete all as specified and as directed by Engineer-in-charge
M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed by Engr-in-charge
M&L for plain cement concrete type D2 1:4:8 (using 40mm graded crushed stone aggregate )as in foundation,filling and mass concrete complete all as specified
S&F mild steel Plates,(plain or chequered), Fe 410-W (Gde E - 250) quality - A, channels, square cut or notched (ordinary and counter sunk) forming with riveted, bolted or welded attachment ,complete all as specified and as directed by Engineer-in-charge
S&F saftey wiremesh of superior quality for arresting falling concrete ,complete all as specified and as directed by Engineer-in-charge
M&L for preparation of new Steel surfaces of any description over 10cm width of girth applying two coats of synthetic enamel paint over coat of red oxide primer etc complete all as spcd and as directed by Engr-in-charge
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) ,complete all as specified and as directed by Engineer-in-charge
Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) ,complete all as specified and as directed by Engineer-in-charge
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface including 15mm thick screed bed in CM 1:4 ,complete all as specified and as directed by Engineer-in-charge
M&L for Plain Cement concrete type C- 2,1:3:6 (using 40mm graded crushed stone aggregate) 50mm thick in sub base of floor ,complete all as specified and as directed by Engineer-in-charge.
S&F Anodised aluminium frame Powder coated (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. ,complete all as specified and as directed by Engineer-in-charge.
M&Lfor 5mm thick plain colour PVC sheet in strips & channel feathered at the edge for fixing on solid PVC wall lining and solid PVC partition inclusive of solvent cement and fix at site ,complete all as specified and as directed by Engineer-in-charge.
M&L for Prelaminated particle board exterior grade with both side decorative choice lamination 18/19mm thick ,complete all as specified and as directed by Engineer-in-charge
M&L for Second class hard wood plain fillet square or rectangular in clean sawn sectional area exc 6 n.exc 13 sq cm secured with nails or brads complete all as specified
M&L for sheet glass ordinary quality and glazing with oil putty 6.3mm/8mm area exc 0.5sqm in each pane including grinding polishing and rounding of edge glass exc 4 n.exc 8mm thick ,complete all as specified and as directed by Engineer-in-charge
S&F Steel locking bolts with mild steel electro galvanized plate and bright bolt not less than 10mm dia 100mm size ,complete all as specified and as directed by Engineer-in-charge.
S&F brass barrel tower bolt exruded section length of bolt 75mm, with cast or sheet barrel and rolled or cast bolts ,complete all as specified and as directed by Engineer-in-charge.
S&F Butt hinge of brass with mild steel hinge pin bright polished and fixed type B-12 of size 50mm,complete all as specified and as directed by Engineer-in-charge.
S&F 50mm dia polished hard wood knob fixed with srews, complete all as specified and as directed by Engineer-in-charge
M&L for rolled section as in framing for cladding,glazing and the like fixed with angle cleats etc Fe-410 Gde E-250 ,complete all as specified and as directed by Engineer-in-charge
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 ,complete all as specified and as directed by Engineer-in-charge
M&L for powder coated aluminium Door/ window/ sliding window / Ventilator / partition frames and shutters using standard aluminium powder coated sections including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws, anodised aluminium fittings suitable Nylon gasket, nylon rollers, maruthi locks, handles, concealed star lock, aluminium F channel for fixing aluminium grill and all necessary fittings and fixtures etc all as specified etc complete of standard sections and fixing to cudappa stone/granite stone with necessary bolts/screws complete all as specified and as directed by Engineer-in-charge.
S&F aluminium anodized grill of 4.75 x 7.75 mm, size of opening 10cm, size of mesh RG 103 (as per royal grill) with aluminium channel `F' angle 20mmx15mm fixed to aluminium frame work complete all as specified and as directed by Engineer-in-charge
M&L for Granite ,20 mm thick machine cut ,work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including 15mm thick screed bed and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,complete all as specified and as directed by Engr-in-Charge
S&F coloured non skid ceramic tiles (square/rectangular) area of each tile exceeding 0.06 Sqm but n.exc 0.11 Sqm,in floors set and jointedin neat cement slurry and pointed in coloured cement to match over all incl 15mm thick screed bed in CM (1:4),complete all as specified and as directed by Engineer-in-charge
Taking up or down 15mm dia steel tubing and connections, segregating serviceable pipe for reuse ,complete all as specified and as directed by Engineer-in-charge. (Note: Old serviceable tubes and other connected accessories retrived from this item shall be used agaist relevent item of Sch A)
Refixing old steel tubing of 15mm dia and connections in new or old position (Walls, ceiling, floors, etc.) ,complete all as specified and as directed by Engineer-in-charge
Supply and fix ,in repairs, brass chromium plated shower rose of 125mm size fixed in 15 mm dia pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge
Supply and fix ,in repair, shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) ,complete all as specified and as directed by Engineer-in-charge.
supply and fix , in repair ,cast iron Nahani trap of 100mm dia including jointing to waste pipe fixed in cement concrete type 1:2:4 type B1 ,complete all as specified and as directed by Engineer-in-charge.
Dismantling of existing water tank and removing to store capacity exc 500 lit and n exc 1000 lit ,complete all as specified and as directed by Engineer-in-charge.
M&L for Plain Cement concrete type C2 (1:3:6) (40mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for providing Joist, channel, angle, or tee sections,Fe-410-W(Grade- E-250) quality-B fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed by Engineer-in-Charge.
Hard drawn steel wire fabric exc 4kg /sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt M&L for TMT bars of dia 10mm and above for handles Complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in bed to PVC pipes 100mm dia including packing under and haunching against the sides of pipes after they are laid and tested ,complete all as specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete (RCC) Nominal mix in cement concrete ,type B1 1:2:4 ( using 20 mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engr-in-Charge.
Use and waste of Formwork for Rough finished surfaces to concrete to sides of pillars, posts, struts, piers, columns and stanchions (Square, rectangular or polygonal) complete all as specified and as directed by Engr-in-Charge.
M & L for 40 mm thick Plain cement concrete type B -0 (1:2:4) using 12.5 mm graded crushed stone aggregate as in sub base, sub floors complete all as specified and as directed by Engineer-in-charge.
S&F Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. ,complete all as specified and as directed by Engineer-in-charge.
M&L for ATT the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area ,complete all as specified and as directed by Engineer-in-charge.
M&L for ATT Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed by Engineer-in-charge.
M&L for ATT Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed by Engineer-in-charge.
M&L for ATT Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engineer-in-charge.
M&L for Plain Cement concrete 75 mm thick ,type C-2,1:3:6 (using 40mm graded crushed stone aggregate) for plinth protection ,complete all as specified and as directed by Engr-in-Charge
S&F Fe 410 -W (Grade- E- 250) quality- A Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed by Engr-in-Charge
M&L for 15mm thick mineral fiber board fine fissured in true horizontal level of size 600mmx600mm as in false ceiling, including hot dipped galvanised section, exposed surface with percolated capping, main and cross runners centre to centre of size 24mmx32mm having 0.27mm gauge at every 1200 mm centre to centre and wall angle of size 19mm x 19mm having 0.35mm gauge fixed to the periphery of the wall. the grid shall be suspended at at every 1200 mm centre to centre on both directions with using 3mm thick pre-straightened GI wire to ceiling complete with all fixtures such as necessary bolts, nuts and washers as per manufacture's instructions and as directed by Engr-in-charge
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm ,complete all as specified and as directed by Engr-in-Charge
S&F Waste coupling 32mm bore dia of discharge pipe of PTMT (half or full threaded) . (Minimum weight 32mm-45gms) ,complete all as specified and as directed by Engr-in-Charge.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering ,complete all as specified and as directed by Engr-in-Charge
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed by Engr-in-charge
M&L for 40mm thick PCC type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in sub floor, sub bases, floor and paving, complete all as specified and as directed by Engr-in-charge
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of sperture 1.40mm and fixed with stainless steel wire staples ,complete all as specified and as directed by Engineer-in-charge
S&F Urinal spreader of any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed by Engineer-in- Charge
M&L for machine cut Kota stone flooring 20 to 25 mm thick laid, jointed with grey cement slurry and pointed with coloured cement to match the shade of Kota stone as in floor, treads etc including rubbing and mirror polishing laid over and including screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6 , complete all as specified and directed by Engr-in-charge.
M& L for Boring of road crossing in any kind of soil/rock strata all as specified and directed by Engineer-in-Charge.(Note:-All the tools and plants or machninery required for boring shall be included in quoted rates,no extra rate shall be paid on this acccount)
Supply & laying un reinforced precast cement concrete cable cover class HV type 1, flat, size 250mm x 150mm x 40mm , complete all as specified and directed by Engr-in-charge.
Supply & laying GI pipe light graded of size 50mm dia in trenches and fixing on wall / pole with help of suitable size MS clamp for cable protection all as directed.
Supply & laying XLPE insulated of size 4 core 16 Sqmm ,1100 V grade, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminum conductor, complete all as specified and directed by Engr-in-charge.
S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc , complete all as specified and directed by Engr-in-charge.
S&F MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 5 to 32 Amps , complete all as specified and directed by Engr-in-charge.
S&F MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 32 Amps , complete all as specified and directed by Engr-in-charge.
Earthing complete with galvanised steel earth plate electrode 60 cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal round level) with edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and GI washers earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around bottom and top of earth plate as shown in electrical plate No. 3 of SSR Part-I and connecting to earthing test point and testing on completion including PCC 1:3:6 type C2 for earthing pit, GI light grade protection pipe of size 15mm dia, watering pipe 20mm bore medium grade, CI cover and frame necessary earth works and PCC work etc complete all as specified. Earth plate shall be surrounded by alternate layer of charcoal of coke and common salt 15cm thick all around the earth plate including bottom and top. (Note: PCC chamber shall be constructed at least 1.5mtr away from the earth electrode and pipe for watering shall be slanting manner)
M & L for point wiring complete with 1.5 Sqmm (Nominal area) PVC insulated multi stranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including PVC concealed conduict ISI marked and conduit fittings including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc c, complete all as specified and directed by Engr-in-charge. (Note:- Cost of MS sunken box and bakelite sheet included in the rate).Of the following:-
for one light point/fan point/5 Amps switch socket/bell/engagement light controlled by one switch
one three pin socket outlet 5 Amps on the independent board
one three pin socket outlet 5 Amps on the same board complete all as specified.
S&F switch Piano type single pole one way 5 Amp,230 Volt , complete all as specified and directed by Engr-in-charge. . Make: Havells/Anchor/Legrand
S&F socket two in one ,3 Pin 5 Amps 230 Volt , complete all as specified and directed by Engr-in-charge. , Make: Havells/Anchor/Legrand
M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked , complete all as specified and directed by Engr-in-charge. Make: Havells/Anchor/Legrand
S&F ,ceiling fan ,1400 mm sweep ,single phase 240 V,AC Complete with all fitting items including 3 core copper flexible wire from ceiling rose to Fan complete all as specified and directed. Make: Bajaj/Crompton/Havells
Supply,fixing and testing of LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin.Make: Bajaj/Crompton/Havells
S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 4 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed.Make: Havells/Indoasian/HPL
M&L for sub main wiring of PVC FRLS insulated unsheathed two single core 4 sqmm copper multi stranded conductor including one run of single core copper conductor of size 4 sqmm as earth wire drawing into concealed PVC conduit , complete all as specified and directed by Engr-in-charge.Make: HPL/Havells/Paragon
Suppy and fixing Wall mounted fan 400mm sweep 220V, single phase AC with and including three core wire from fan to socket point complete with all necessary T&P required and making good suface finish , complete all as specified and directed by Engr-in-charge.Make: Havells/Bajaj/Crompton.
Taking down old serviceable solar street light along with solar panel, disconnecting all electrical coneection and bracket from the solar light and solar panel deposited to MES Store after petty repair , complete all as specified and directed by Engr-in-charge.(Note: Old serviciable solar panel,solar lights and connected fittings retrived from taking down shall be used under relevent item of BOQ).
Fixing only old serviciable solar street light fitting with and including solar street light,solar panel alongwith bracket,nut,bolts and washer on pole mouned and checking of its all connection after completion of the work , complete all as specified and directed by Engr-in-charge.
Supply & fix GI pipe light graded of size 50 mm dia in trenches and fixing on wall / pole with help of suitable size MS clamp for cable protection , complete all as specified and directed by Engr-in-charge.
S&F DG Set battey of capacity 12 Volts, 65 Ah complete with autobat invatower heat sealed low maintenance battery made with low antimony selenium alloy (LASA) in positive and negative elctrodes,Instant cranking,high density with extreme power with and including polyethylene envelope separators with glass mat vibration resistant for longer life , complete all as specified and directed by Engr-in-charge.Make: Exide/Amaron
Supply,Fabrication and fixing angle iron frame of equal angle iron/MS rod/MS Sheets/Bends/Tee /Collars/Blank Flange etc of existing size and specification cut to size and welding of tank,valve pit covers of any size and specification , complete all as specified and directed by Engr-in-charge.
Supply ,installation,fixing ,testing and commissiong of Inverter type air cooled split air conditioners electric driven single phase AC supply with R-32/R-410 refrigerant, 240 Volts 50 Hz, comprising of all components e.g. Outdoor condensing unit indoor blower unit, wall/roof mounting with suitable brackets as recommended by manufacturers confirming to Bureau of Energy Efficiency(BEE) not less than 3 Star rating, complete including copper piping of adequate size and of required length as recommended or directed duly insulated with suitable insulating material e.g. glass wool, plywood, moulded thermocoal etc initial charging of refrigerant eco friendly as specified and recommended by manufacturer all as specified and directed by Engineer in Charge of capacity 2 TR. Make- Carrier, Bluestar, Hitachi
S& F voltage stabilizer of capacity 5 KVA working range between 170-270 V,with built in thermal overload protection,high &low voltage cutoff,time delay system with accuracy of ± 5 % all as specified and as directed by Engineer-in-charge., Make- Volina, V-Guard
M&L for sub main wiring of PVC FRLSH insulated unsheathed two core 6 sqmm copper multi stranded conductor including one run of single core copper conductor of size 6.0 sqmm as earth wire drawing in concealed PVC conduit complete all as specified and directed.Make: HPL/Havells/Paragon (Note: Three lengths of 6 Sqmm cable shall be measured as one length)
S&F, in repair ,wall mounting type AC timer having Delay Time Facility, Auto & manual switch ,Suitable for window ,splits type AC of capacity 1.5/2 TR.Operating on AC input Supply: 230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals all as specified and directed by Engineer-in-Charge.
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SPN of capacity 20 Amps , complete all as specified and directed by Engr-in-charge.
S&F, in repair ,Steel water tubing 80mm dia bore ISI marked medium grade galvanised including tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road or laid in floors complete all as specified.Make: Jindal/Prakash Surya/Supreme
S&F, in repair , Steel water tubing 40mm dia bore ISI marked medium grade galvanised including tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road or laid in floors complete all as specified.Make: Jindal/Prakash Surya/Supreme
S&F, in repair ,Steel water tubing 25mm dia bore ISI marked medium grade galvanised including tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road or laid in floors complete all as specified.Make: Jindal/Prakash Surya/Supreme
S&F, in repair , Steel water tubing 20mm dia bore ISI marked medium grade galvanised including tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road or laid in floors complete all as specified.Make: Jindal/Prakash Surya/Supreme
S&F, in repair ,Steel water tubing 15mm dia bore ISI marked medium grade galvanised including tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road or laid in floors complete all as specified.Make: Jindal/Prakash Surya/Supreme
S&F, in repair ,Gun metal globe valve class-II with iron wheel both end screwed for iron pipe 40mm dia bore complete all as specified.
S&F, in repair ,Gun metal globe valve class-II with iron wheel both end screwed for iron pipe 25mm dia bore complete all as specified.
Supply and fixed gun metal globe or gate valve 15 mm with iron wheel head screwed both ends for galvanised iron pipe fixing for each earthing pit , complete all as specified and directed by Engr-in-charge.
Supply, install & testing in replacement of Cast iron sluice valve class PN-1.6, conforming to IS complete suitable for 80mm bore of pipe with flanged ends and drilled gun m etal spindle, CI gate with brass ring and iron wheel handle, cast iron cap etc complete including installation, jointing including jointing material and testing all as specified.Make: Kirloskar/Venus
S&F, in repair , gun metal globe or gate valve 20 mm with iron wheel head screwed both ends for galvanised iron pipe , complete all as specified and directed by Engr-in-charge.
M&L for making connection from existing 80/40/25/20 mm GI pipe by inserting "Tee"/Reducer of any dia complete including excavation and earth work , complete all as specified and directed by Engr-in-charge.
S&F, in repair ,Rotational moulded polyethylene water storage tanks of capacity 1000 ltrs triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I
M&L for providing valve chember including necessary earth work in any type of soil PCC 1:3:6 in base concret brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50x50x6mm MS complite with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of size 900mmx900mmx900mm , complete all as specified and directed by Engr-in-charge.
M&L for providing valve chember including necessary earth work in any type of soil PCC 1:3:6 in base concret brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50x50x6mm MS complite with 2 coat of synthatic enameled paint over a coat of red oxide on all steel work and 2 coats of white washing on plastered surface of valve chamber of size 450mmx450mmx450mm .
Supply ,Installing ,Fixing and testing of metallic ventilair exhaust fan ,230 mm sweep,1400 rpm ,single phase 240 V,AC Complete with all fitting items including 3 core copper flexible wire from ceiling rose to Exhaust Fan , complete all as specified and directed by Engr-in-charge. Make: Bajaj/Crompton/Havells
M&L for cutting opening in cement concrete/brick wall for exhaust fan including making good distrubed surface , complete all as specified and directed by Engr-in-charge.
M & L for point wiring complete with 2.5 Sqmm (Nominal area) PVC insulated multi stranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including steel concealed conduit medium quality and conduit fittings for 3 pin 15 amp multi core swich socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc , complete all as specified and directed by Engr-in-charge. (Note:- Cost of MS sunken box and bakelite sheet included in the rate)
S & F Switch piano type single pole 1way 15 amp on laminated sheet top cover , complete all as specified and directed by Engr-in-charge. (Note:- Cost of sheet cover included point wiring)
S & F Switch piano type 6 pin 16 amp ,230 volts , complete all as specified and directed by Engr-in-charge.
S & F PVC Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings ,with backlite 20 mm back plate , complete all as specified and directed by Engr-in-charge.
S & F Air circulator fan ,230 V single Phase oscillating type ,450 mm sweep ,suitable for wall mounting , complete all as specified and directed by Engr-in-charge.
S & F LED tub light fixture ,environmental friendly,energy efficient and ready to used 18 W ,LED 6000K ( 4 feet) , complete all as specified and directed by Engr-in-charge.
S & F Batten for LED tub light fixture , with extruded aluminium heat sink ,environmental friendly,energy efficient and ready to used for 18 W ,LED 6000K ( 4 feet) ,including electric connection with PVC copper flexible twin core cable,1.0 Sqmm from ceiling rose to light fittings, complete all as specified and directed by Engr-in-charge
Supply ,Installing ,Fixing and testing of metallic ventilair exhaust fan ,200 mm sweep,1400 rpm ,single phase 240 V AC ,air delivery 100 CFM ,Complete with all fitting items including 3 core copper flexible wire from ceiling rose to Exhaust Fan , complete all as specified and directed by Engr-in-charge. Make: Bajaj/Crompton/Havells
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SPN of capacity 32 Amps , complete all as specified and directed by Engr-in-charge.
S & F Switch socket combination 5/16 Amp , 5 in1 ,complete all as specified and directed by Engr-in-charge.
S & F and installation of storage type vertical water heater 25 lit capacity ,5 star rating 230 Volts, 50 Hz ,including automatic thermal cut out, fuisible plug for protection, no return valve and metal connector for hot and cold water, with On/Off indicator, ,complete all as specified and directed by Engr-in-charge.
S & F,15mm dia steel tubing and connections, segregating serviceable pipe for reuse ,complete all as specified and as directed by Engineer-in-charge.
S & F, PVC connections 15mm size with PTMT nuts of length 600mm ,complete all as specified and as directed by Engineer-in-charge.
M/s Shree Construction Co
Vinod Enterprises
Atharva Enterprises
sahajanand const co.
DARSHAN CONSTRUCTION Co.
sapana enterprises
A G ENTERPRISES
Vishal Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .