SE (CIVIL) AVVNL AJMER
O/O SE (CIVIL), HATHI BHATA POWER HOUSE , AVVNL , AJMER
Replacement of smoke detector system at Vidyut Bhawan Ajmer
2026_AVVNL_601249_1
AVV2627WSOB00276
Open Tender
Civil Works
Percentage
90 days
O/O SE (CIVIL) AVVNL AJMER
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹1,180
AO O and M AVVNL AJMER and MD RISL JAIPUR
₹22,000
Yes
28 Sept 2026
28 Sept 2026
23 Oct 2026
28 Sept 2026
22 Oct 2026
28 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Raj. Electric-2025 | - | - | - | - |
| 1 | SITC of UL 7th edition and FM certified photoelectric Analog addressable Smoke detector with mounting base & LED etc. as required. | 250 | Each | 2,606 | ₹6,51,500 |
| 2 | SITC of UL 7th edition / FM certified Analouge Addressable type Rate of Rise Heat Detectors with mounting base & LED etc. as required. | 10 | Each | 2,499 | ₹24,990 |
| 3 | SITC of UL 7th edition / FM certified Addressable sounder with strobe light, Direct powered from FACP with sound level 90 dB and programmable from the panel etc. as required. | 10 | Each | 4,538 | ₹45,380 |
| 4 | SITC of UL 7th edition / FM certified Addessable Manual Call point (MCP) with LED / FIRE Indication Etc. as required. | 5 | Each | 3,582 | ₹17,910 |
| 5 | SITC of UL 7th edition / FM certified Microprocessor based inteligent, Analogue addressable,modular, Fire Alarm Control Panel with each loop capacity of 250 detectors/devices with minimum Loop length up to 2.0 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24 AH 2 x 12V, SMF Lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, Touch screen display unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port (both RS485 & Ethernet), Serial port for printer, two supervisory inputs, two position key switch and USB port for programming. including the cost of all accessories Etc. as required.Loop expansion card | 1 | Per Loop | 82,745 | ₹82,745 |
| 6 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required. 25 mm | 1,000 | Mtr | 45 | ₹45,000 |
| 7 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. 2 x 1.5 sq.mm | 2,000 | Mtr | 43 | ₹86,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.90 MB
TDsmokedectector.pdf
Tender Documents • 3.44 MB
BOQ_1065786.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .