| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-Finance | L1 | Accepted-Finance Valid documents received and accepted | |
| 2 | L2₹18.5 L+₹1.7 L (10.1%)Accepted-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Accepted-Finance Valid documents received and accepted | |
| 3 | L3₹28.9 L+₹12.1 L (72.1%)Accepted-Finance | L3 | Accepted-Finance Valid documents received and accepted |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Sept 2023, 6:00 pmClosed
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
REPAIRS/ RENEWALS/ PERIODICAL MAINT TO LT EQUIPMENTS AT VARIOUS SUB STATIONS IN DOMESTIC AND TECHNICAL AREA AT AFA HYDERABAD.
2023_MES_612414_2
8354/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AFA) Hyderabad
As per tender pages
4 documents required · 4 mandatory
₹500
GE (AFA) Hyderabad
₹40,000
Yes
4 Oct 2023
7 Aug 2023
6 Sept 2023
7 Aug 2023
4 Sept 2023
21 Aug 2023
7 Aug 2023 - 20 Aug 2023
Amount
Disconnecting and taking out existing ACBs from housing and cleaning, rubbing and overhauling the mechanical parts and making serviceable of Local/Remote electrical operation of the panel incl Greasing Oiling , replacement of UNSV Trip coil, Breaker System ,Gear Pinion, roller Switch and re-assembling the same, Servicing of 440V in door ACB 630A to1600A capacity, fixed type/ MDO/ EDO checking of quality of Air interrupter, insulation resistances, static contact resistance, Testing (IR value, ratio test, polarity test) , connection testing and calibration of relay including all other functional tests of the ACB, panel complete all as specified and as directed. Location:- Sub Stn No 7, Sub Stn No 11, Sub Stn No 02, Sub Stn No 08, Sub Stn No 15, And Sub Stn No 05.
Disconnecting all incoming and outgoing cables, removing the servo stabilizer Transporting to local work shop opening, servicing/repairing the stabilizer including draining out the unserviceable transformer oil, dismantling and inspection of parts, and replacing the worn out/unserviceable spares of capacity 10 to 15 KVA and transporting back to location installing and connoting up the incoming and outgoing cable all as directed. Note: (i) All spares except filling of oil required for replacement including rewinding shall be measured paid separately. (ii) All spares shall be suitable for the existing Make and Model of the Servo Stabilizer/ Isolation Transformer.
Same as per item No (2) above but servo stabilizer of capacity 40KVA.
Supply and fix in repairs MCCB adjustable thermal & fixed magnetic release 4 pole 50 kA 400 A including dismantling and taking out the existing unserviceable MCCB , connecting up complete all as directed at site. Make :L&T/Standard /Schneider/Legrand
Supply and fix in repairs Change Over Switch 400 Amps, front operated, open execution type including dismantling and taking out the existing unserviceable Change over Make :L&T/Standard /Schneider/Legrand
Supply and fix in repairs Change Over Switch 250 Amps, front operated, open execution type including dismantling and taking out the existing unserviceable Change over Make :L&T/Standard /Schneider/Legrand
Supply and fix in repairs Change Over Switch 160 Amps, front operated, open execution typeincluding dismantling and taking out the existing unserviceable Change over Make :L&T/Standard /Schneider/Legrand
Supply and fix in repairs Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply - 01 No
Supply and fix in repairs 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No
Supply and fix in repairs LED indicating lamps with holder for main supply - (R-Y-B)
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 100 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, including taking down old unserviceable. The feeder pillar shall be comprising of the followings :-
(i) MCCB 4 pole 200 Amps, 16 KA, 415 Volts - 01 Nos
(ii) MCCB 4 pole 40 Amps, 16 KA, 415 Volts - 07 Nos
(vi) LED indicating lamps with holder for main supply - 1 Set of 3
Note : Suitable capacity of Aluminum Bus Bar with PVC sleevesfor all MCCB's cast to be inluded.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised iron 32 x 6 mm strip connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 4 of MES Schedule Part-I (2009) and all as directed. Note: (i) Cost of GI strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover, test point etc.
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 185 sqmm 3.5 core including dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 95 sqmm 3.5 core including dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 25 sqmm 4 core including dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 100 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, including taking down old unserviceable. The feeder pillar shall be comprising of the followings :-
(i) MCCB 4 pole 125 Amps, 25 KA, 415 Volts - 01 Nos
(iv) Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply - 02 No
(v) 3 Pole power contactor of AC 3 duty rating of 50 amps having 240 volts rated coil and having 2 NO + 2 NC - 02 Nos
(vi) LED indicating lamps with holder for main supply - 1 Set of 3
(vii) Instrumental control wiring MCB 2 Amps - 03 Nos
(ix) ON/OFF Push Buttons -02Nos.
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 500 amps/Ph and 250A/Neutral, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, including taking down old unserviceable. The feeder pillar shall be comprising of the followings :-
(i) MCCB 4 pole 400 Amps, 35 KA, 415 Volts - 02 Nos
(i) MCCB 4 pole 125 Amps, 25 KA, 415 Volts - 01 Nos
(iii) MCCB 4 pole 63 Amps, 16 KA, 415 Volts - 10 Nos
(iv) Changeover switch 400A,4pole-01No.
(vi) LED indicating lamps with holder for main supply - 2 Set of 3
Note : Suitable capacity of Aluminum Bus Bar with PVC sleeves for all MCCB's Changeover Switch cost to be inluded.
S&F bus bar boxes made out of 3 mm thick CRCA sheet , front opening aluminium bus bar strips of 100 Amp and 200 mm long each , insulator, nut/bolts incl one no of 200 Amps MCCB FP 25 kA as incoming, MCB TPN 63 A 16 kA-01 No, MCB TP 25 KA-02 Nos as outgoing, terminating the existing incoming and outgoing cables and necessary glands, lugs, after Remove the unsv extg bus bar box, disconnecting the cable, uncoiling the loop etc alongwith earth work, painting with 2 coats of synthetic enamel paint over a coat of red oxide primer complete with 40x 6 mm angle iron support of length not less than 0.5 m grouted on PCC plateform for proper fixing arrangements complete all as specified and directed
Demolition & dismantling Cement concrete plateform on floor of any description and in any position not otherwise specifically complete all as specified and directed by Engr- in- charge.
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in platform, filling and mass concrete, coping to pole for embedding stay road all as specified, including necessary form work and applying two coats of white wash to exposed surface of coping/platform all as specified.
M&L PCC 1:4:8 type D2 using 40mm graded stone aggregate for pole foundation filling and mass concrete all as specified.
Material and labour for providing PCC 1:3:6 type C-2 mix using 40mm graded stone aggregate for stay wire all as directed.
M&L Pre-cast cement concrete block masonry type C1 (1:3:6) using 20mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in mortar, complete, for foundation/platform/pedestal etc, all as specified and directed by Engr- in- charge.
M&L for rendering 10mm thick on brick/concrete/ block masonery surface in Cm (1:6) finished fair all as specified and directed by Engr- in- charge.
M&L and laying for stone course boulders exceeding 7 cm and upto 15 cm to avoid growth of grass/weeds and protection against soil erosion at outdoor electrical sub station all as specified and directed by Engr-in -Charge.
Taking down unserviceable mat sheet and S&F Fire retardant / extinguishing electric insulated synthetic mat suitable for electric system of 2.5mm thick, confirming to relevant IS/IEC codes, tested for breakdown strength, tensile elongation properties, insulation resistance, effect of acid, alkaline, diesel and transformer oil leakage, current test, fire test etc., having a minimum width of 100mm including all pasting materials such as PU resin, chemi bond (hardener), special PVC adhesive and fixed in electrical installation complete as per sample all as specified and as directed.
S&F Dry type Fire Extinguisher (For A-B-C type of fire) Packed in 4.5 Kg Cylinder (ISI marked) with necessary fixing arrangement on wall complete all as specified and directed by Engr- in- charge. Make:- GE TECH/UNIMAX/ CEASEFIRE
S&F Electric Shock Treatment chart (as per sample) in language English & Local (Telgu) on PVC sheet with white colour letter on red colour base complete all as specified and directed by Engr- in- charge.
L and S ENTERPRISES
Allied Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .