Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹17.0 L+₹1.6 L (10.2%)Rejected-AOC | L2 | Rejected-AOC not found lowest | |
| 3 | L3₹17.5 L+₹2.1 L (13.7%)Rejected-AOC NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC not found lowest | |
| 4 | L4₹17.6 L+₹2.2 L (14.4%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC not found lowest | |
| 5 | L5₹17.9 L+₹2.5 L (16.1%)Rejected-AOC B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC not found lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
22 Jun 2022, 6:00 pmClosed
GE Basoli
GE Basoli PO lakhanpur Distt Kathua JK
REPAIR AND MAINTENANCEOF SECURITY LIGHTS, ROAD LIGHTS, SOLAR LIGHTS AND STAND BY GENERATOR SETS AT BASOLI STATION UNDER GE BASOLI
2022_MES_526393_1
GE/BAS-20/2022-23
Open Tender
Civil Works
Item Rate
180 days
Basoli station
class E Catg b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Basoli
₹40,000
Yes
29 Dec 2022
26 May 2022
24 Jun 2022
26 May 2022
22 Jun 2022
9 Jun 2022
Amount
Repair / rectification for street light/ perimeter light/ flood light any type, capacity & make to make the security / street lights in serviceable condition as intimated by JE EM/ Engineer-in-Charge after rectification/ trace out the fault which includes removing of street/ security light fitting from LT / HT PCC/ Steel tubular/ Swan neck poles, refixing after repair, tightening of loose connection on ACSR conductor / with bus bar chamber / in DB, replacement of lamp, lamp holder, capacitor,replacement of connection wire or any other part and refixing in proper alignment on GI Pipe bracket or by other means as per site requirement including replacement of screws, nuts , bolts washers as required proper connection with PVC insulation tape etc complete to keep the light in serviceable condition through out the period of contract by repairing on time all as directed to the entire satisfaction of JE EM/ Engineer-in-Charge Note:- (i) Worn out / damaged/ Unserviceable parts to be replaced shall be measured and paid for separately under relavant items of Sch " A' as supply only and fixing is deemed to be included under this item. (ii) All the T&P and transportation required for the work shall be arranged by the contractor which shall be deemed to be included in quoted rate. Contractor shall provide the all type of T&P i.e. tools, insulation tape, ladder any type etc to electricial for attending the complaints. The quoted rate include the cost of minor items i.e. screws, nuts, washers for light fitting etc. (iii) Contractor shall provide & maintain the register regarding 100% serviceability of security lights duly signed by the JE/ Engineer-in-Charge , Contractor , unit rep. (iv) The work will be carried out on at as per direction of JE/ Engr-in-Charge. (v) The electrician shall receive the complaint from JE/ Engineer-in-Charge on complaint slip and after completion of job the slip shall be deposited to JE/ Engineer-in-Charge daily duly signed by users. The printed complaint slip and complaint register shall be arranged by the contractor without any extra cost. (vi) An inventory for the parts/ spares which are found unserviceable and requir replacement with new parts/ spare shall be prepared and kept in record duly signed by Engineer-in-Charge and Contractor.
Excavation in trenches not exc 1.5m wide and not exc 1.5 mtr deep and getting out in any type of soil complete all as specified and directed .
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. (Punned thickness shall be measured)
Material and labour for well burnt, old size Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable with width equal to length of brick complete all as specified and directed.
Supply only and replaced under the item No.1 Driver electronic compact type suitable for LED street light fitting 30-70 Watt as per sample/required at site complete all as specified and directed.
Supply only and replaced under the item No.1 Driver electronic compact type suitable for LED street light fitting 90 Wattas per sample/required at site complete all as specified and directed.
Supply only and replaced under the item No.1 Driver electronic compact type suitable for LED street light fitting 120 Wat tas per sample/required at site complete all as specified and directed.
Supply and fix in repair / replacement LED street light fitting of capacity 45 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 and impact reistance of IK07 with high power LEDs as light suorce with electronic chip and driver (lamp type 45W LED) efficacy 100 Lm/W 5700 K suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement LED street light fitting of capacity 60 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 and impact reistance of IK07 with high power LEDs as light suorce with electronic chip and driver (lamp type 60WLED) efficacy 100 Lm/W 5700 K suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement LED street light fitting of capacity 35 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 with high power LEDs as light suorce with electronic chip and driver (lamp type 35WLED) efficacy 100 Lm/W 5700 K suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement flood light of capacity 45 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 made out pressure die cast aluminium housing suitable lens & tughened glass with high power LEDs as light source with electronic chip and driver of of make polycab /Philips/Jagubar with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement flood light of capacity 50 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 made out pressure die cast aluminium housing suitable lens & tughened glass with high power LEDs as light source with electronic chip and driver of make polycab /Philips/Jagubar with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in eplacement flood light of capacity 60 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 made out pressure die cast aluminium housing suitable lens & tughened glass with high power LEDs as light source with electronic chip and driver of of make polycab /Philips/Jagubar complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in eplacement flood light of capacity 200 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 made out pressure die cast aluminium housing suitable lens & tughened glass with high power LEDs as light source with electronic chip and driver of of make polycab /Philips/Jagubar complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix replacement of three core copper conductor multi-stranded type PVC insulated and sheathed of 2.5 sqmm, 1100 volts grade and connected to the street light from over head line or Junction boxes complete all as specified and directed.
Supply and fixing in replacement PVC conduit 25mm dia medium grade for fixing along the pole with 02 Nos clamps per pole the connections from junction box to street lights all as specified and directed.
Taking out old unserviceable poles of PCC/MS from ground by dismantling foundation and provide new by Supply and errect steel tubular swaged pole type 410 SP-31 (9 meter long) complete with cast iron / MS base plate, top plate welded with MS round sheet with necessary nuts, bolts and wahsers duly painted with a coat of red oxide primer and two coat of aluminum paint including black and yellow strip 30cm in height above the copying of the pole complete all as specified and as directed.
M&L for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly complete all as specified and as directed.
M&L for PCC ( 1 : 2 : 4 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly complete all as specified and as directed.
Supply and laying , in replacement, in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 10 sq mm X 2 core stranded conductor, complete all as specified and as directed.
Supply and laying, in replacement, in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 10 sq mm X 4 core stranded conductor, complete all as specified and as directed.
Supply and laying , in replacement, in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 16 sq mm X 2 core stranded conductor, complete all as specified and as directed.
Supply and laying , in replacement, in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 16 sq mm X 4 core stranded conductor, complete all as specified and as directed.
Supply and laying , in replacement, in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 25 sq mm X 3.5 corestranded conductor,complete all as specified and as directed.
S&F in replacement DWC high density polyethelene pipes having dia 63mm/50mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930 (Part-I & II) for protection of underground cable laid along pole/ along wall / in PCC on GL/ Roof and including all fittings as required at site complete all as specified and as directed.
Supply and fix in replacement for junction box of size 300x250x150mm made out of 1.6 mm thick CRCA sheet powder coated front hinged door with openable and self closing arrangements including aluminium bus bar 3 Phase 4 wire system of size 20mm x 5mm fixed on SMC/DMC insulators and cable entry glands for connections and MCB SP 6 Amps-01 No all as required and fixed to poles with MS clamp made out of MS flat iron of size 25x5mm and including nuts, bolts and washers complete all as specified and directed.
S&F in replacment of smart integrated solar street light LED with built in mono crystalline panel, litheium ferro phosphate battery MPPT charge controller and PIR Sensor with colour temperature 6000 to 6500 K capacity 12 W all in one standard, complete all as specified and as directed.
S&F in replacment of smart integrated solar street light LED with built in mono crystalline panel, litheium ferro phosphate battery MPPT charge controller and PIR Sensor with colour temperature 6000 to 6500 K capacity 15 W all in one standard complete all as specified and as directed.
Supply and fix in replacement Off load change over switch four pole with sheet metal enclosure of capacity 63 Amps , 415 Volts,Ac with necessary nuts, bolts and washers including necessary electric connections incl taking down all as specified and directed
Supply and fix in replacement Off load change over switch four pole with sheet metal enclosure of capacity 100 Amps , 415 Volts,Ac with necessary nuts, bolts and washers including necessary electric connections incl taking down all as specified and directed
S&F in repair structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, complete all as specified and as directed.
M&L for comprehensive maintenance and repair of diesel engine of DG sets 160 KVA capacity installed at various locations, by periodical servicing maintenance as per OEM recommendations, repair including replacement of defective/ unserviceable spare parts, tracing & removing of any fault/error indication or meassage showing/ indicating on display screen, greasing to doors/ over hauling to various parts, cleaning of DG set, inspecting the serviceability of all parts and testing on full load after periodical service/ repair by manufacturer's authosied workshop , complete as recommended by OEM and BOO, all as specified and as directed. NOTE:- Parts shall be replaced on recommandation of BOO and shall be measured and paid for seperately under respective items. The maintenance of above mentioned DG sets carried out will be measured as one unit)
All as per Srl Item No 34 above but DG Set of 100 KVA capacity complete all as specified and directed by BOO. NOTE:- The maintenance of above mentioned DG set carried out will be measured as one unit)
All as per Srl Item No 34 above but DG Set of 63.5KVA/50 KVA capacity complete all as specified and as directed by BOO. (Note: The maintenance of above mentioned DG set carried out will be measured as one unit)
All as per Srl Item No 34 above but DG Set of 40 KVA/30 KVA capacity complete all as specified and as directed by BOO. (Note: The maintenance of above mentioned DG set carried out will be measured as one unit)
Notes for Sr Item No 34 to 37:- The BOO will examine the DG set at the time of opening of DG set by approved firm engineer or trained mechanic by the approval of GE, the following shall be covered as under :- (i) New spare parts and engine oil shall be measured and paid separately under respective items. (ii) Labour charges for replacement of old engine oil and old defective spare parts shall be deemed included in quoted rates. (iii) Cost of routine lubrication/ greasing to spare parts, lubricants/grease, tightening of nut, bolts and washers etc. shall deemed to be included in quoted rates. (iv) Cost of fixing and transportation of all components/ spare parts required being repair, of DG sets from site to workshop for repair and workshop to site after repair shall be deemed included in quoted rates. (v) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per TI-04 of 1984 and maintenance record, prepared/ maintained by contractor and signed by concerned JE E/M, Engineer-In-Charge and Contractor. This maintenance record shall be produce to Garrison Engineer whenever asked. (vi) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per following periodicity: a) Stage-I (Monthly): (i) Cleaning of air cleaner/ filter. (ii) Changing of lubricants and oil filter elements. (iii) Cleaning of fuel tanks and cleaning of fuel filter elements. (iv) Cleaning of radiator cooling fins and top up of coolant. v) Cleaning of line cylinder head fins, in case of air cooled engines. (vi) Checking of all electrical instruments/indicating or any other gauge i.e. frequency meter,voltmeter, ammeter, revolution meter, Hrs run meter, water temp gauge, fuel gauge etc for satisfactory functioning. (b) Stage-II (Quarterly): (i) Changing of engine oil, if required, and clean the pre-cleaner bowl. (ii) Check/ open radiator fins, and clean, if chocked/ blocked. (iii) Check button filter in banjo bolt of feed pump. (iv) Drain the water from water separator, if provided. (v) Check all external fasteners as per specified torques. (vi) battery lead connections and top up distiled water in battery. (vii) Check belt alignment and belt condition. (viii) Check turbo changer. (ix) Leakage in air take/ exhaust of exhaust piping (x) Lubrication to the turbo charger,Oil filter. (xi) Cleaning of fuel tank of DG set 160 to 30KVA any type(inbuilt in canopy/ separate storage tank) by removing all silt /dirt/ all residual, foreign particles any type etc, removing any type of leakage by welding/brazing and writing date of cleaning with synthetic enemel paint complete all as specified and as directed.
Replacement of existing UNSV parts with new parts (fixing shall be paid against Srl item No. 44 of DG set 160 KVA (a) Fuel Filter
(b) Oil filter
( c) Fan belt
( d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
(f) Air filter
Replacement of existing UNSV parts with new parts (fixing shall be paid against Srl item No. 45 of DG set 100 KVA (a) Fuel Filter
(b) Oil filter
( c) Fan belt
(d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
( f) Air filter
Replacement of existing UNSV parts with new parts (fixing shall be paid against Srl item No. 46 of DG set 62.5/50 KVA (a) Fuel Filter
(b) Oil filter
( c) Fan belt
(d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
( f) Air filter
Replacement of existing UNSV parts with new parts (fixing shall be paid against Srl item No. 47 of DG set 40/30 KVA (a) Fuel Filter
(b) Oil filter
( c) Fan belt
(d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
( f) Air filter
Replacement of old damaged battery lead with new battery lead of copper conductor of 50 Sqmm cross-sectional area, multistranded, single core, PVC insulated fitted with lugs/ terminals at one end and brass terminals at other end, complete all as specified and as directed by Engineer-In-Charge. (Note: The battery lead replaced shall have colour as per colour coding. The brass terminal provided on battery end side shall be measured & paid separately.)
Supply only injection nozzle for DG set of 160 to 100 KVA capacity, if found defective by OEM and BOO during comprehensive serviceing of DG set, complete all as specified and as directed.
All as per Srl Item No 64 above but DG Set of 62.5 to 30 KVA capacity complete all as specified and as directed by BOO.
Supply only coolant fluid of make as approved by GE /BOO suitable for radiator of DG set of any capacity/make and shall be topup during comperehensive service of DG set, complete all as specified and as directed .
Supply only Engine oil/ lubricant, 20 W 40 grade or any other grade as recommended by OEM of Engine or BOO suitable for DG set of any capacity and any make, and shall be topup during comperehensive service of DG set, complete all as specified and as directed .
Taking out FIP from DG set of 30/40 KVA capacity, transportation to manufacturer's authorised service centre and recallibration & transpotation to same or other location as directed incl. replacement of all necessary spare parts such as delivery valves , plunger , 'O' ring spring etc complete all as specified and directed.
All as per Item No 68 above but DG Set of 62.5/100 KVA capacity complete all as specified and as directed by BOO.
Repair and maintenance of DG set control panel, checking all the electrical connections of engine/alternator/ control panel instruments ie lub oil, pressure gauge,temprature gauge, ameter, battery , volt meter,ac volt meter,ac ameter, frequecny meter etc, calibration of modules microprocessor, tightening all the connection, replacement of defective wiring & cable and lugs of DG set of cap 30KVA to 63KVA DG set and replacing of the following parts as under :-
Voltmeter digital/analog type 96x96mm having range as per existing
Ammeter digital/analog type 96x96mm having range as per existing
Frequency meter digital/analog type 96x96mm
M&L for replacement of battery 12 volt, 80 AH heavy duty maintenance free including initial charged complete in all respects. Make Exide Note:- Item shall be executed as per recommandation of BOO.
M&L for replacement of battery 12 volt, 150 AH heavy duty maintenance free incl initial charged complete in all respects. Make Exide Note:- Item shall be executed as per recommandation of BOO.
M&L for repair and maintenance to door of DG set , including taking down door to the work shop from site and fixed suitable new hinges incl welding work if required and painting the same as existing colour and refixing the same on DG set complete and as directed. Note:- Item shall be executed as per recommandation of BOO.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. (Note: The rate quoted include cost of min 7.5 metre earthing wire .)
M&L for errecting of old steel tubular /PCC LT pole retrieved from taking out and errecting at a place where required and specifically directed by GE and planted in the earth in PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation all as specified and directed. Note :- Earth work and PCC work shall be measured and paid separately.
S&F in repair and replacement engine parts of 40 KVA DG Set Piston rod, Piston ring, self starter and bush etc complete all as specfied and directed. Note :- The item shall only be executed after recommandation of BOO and shall be repaired through authorised rep/workshop of manufacturer only.
Standard engineers
M/S SURINDER KUMAR MAHAJAN
kailu construction co
KAPOOR AUTOMOBILES
BALKRISHAN GUPTA AND SONS
KALSI CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .