| 1 | L-1₹16.4 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹16.7 L+₹28,805 (1.75%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹17.6 L+₹1.2 L (7.11%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹18.4 L+₹2.0 L (12.2%)Rejected-Finance | L-4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹18.9 L+₹2.5 L (15.3%)Rejected-Finance B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹19.3 L
EMD Value
₹38,660
Closing Date
26 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO NP-16 (CSS) UNDER GE (NORTH) UDHAMPUR
2020_MES_367161_1
CWE/U(N)-46/2020-21
Open Tender
Civil Works
Item Rate
180 days
Udhampur
as per tender
7 documents required · 7 mandatory
₹500
GE (North) Udhampur
₹38,660
Yes
29 Sept 2020
6 Aug 2020
28 Aug 2020
6 Aug 2020
26 Aug 2020
14 Aug 2020
60 days
Amount
False ceiling with Everest Fibre Cement Designer tile Ivory/white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 595mmx595mm and any one of the design (occeanic , lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @120 gms, both sides inclusive) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet and cross T of size 15x32mm made of 0.30mm sheet spaced between main T at 600mm c/c from a grid of 600x600mm and wall angle of size 15x20mm made of 0.30mm thick sheet and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers grills, light suspended from ceiling using GI soffit cleats fixed to existing rafters, purlin etc with dash fastners Gl adjustable rods of 3mm dia with galvanised butterfy level clips, spaced at 1200mm c/c along main T, bottom exposed width of 15mm of all T-sections shall be centre black pre-painted with polyester paint and having a load bearing capacity of 12 kg/sqm and refixed all existing electric wiring and fixture including dismantling of existing false ceiling, complete at all heights as directed by Engr-in-Charge.
BLANK
Taking down cement plaster or wall tiles dado/skirting of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
10mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
Preparing of surfaces by complete removal of existing treatment from plastered or unplastered old decorated surfaces of wall, chajjas, etc. by brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying two coats of oil bound distemper over and including a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Preparing plastered or unplastered new surfaces of walls and applying two coats of cement base paint, complete all as specified and as directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Taking down steel windows/ventilators with frames with shutters (without taking off shutters from frames) each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) not exceeding 2.5 sqm , complete all as specified and directed by Engineer-in Charge.
S&F Factory made Pressed Steel windows / Ventilators with glazed & gauzed shutters (Combined with side hund shutter incl box type hinges) steel handle and necessary tacking arrangement, peg stay complete with one shop coat of red oxide zinc chrome primer complete all specified and as directed. Note: (i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3. (ii) Rate quoted are included for wire gauzed & glazed window complete & shall be measured as overall out to out one side only.
BLANK
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.50 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge. Note :- The laying of the membrane shall be got done by zuthorized applicator of the membrane manufacturer.
40 mm thick Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in roof padding over APP WPT laid & fair and even including making joints of size 6mm wide and 10 mm deep filled with bitumen mastic (1:1), complete all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound, complete all as specified & directed by Engr-in-Charge. (Make : Dr Fixit, LW+, STP Ltd No 1 (L) & SIKA or equivalent as specified in PS)
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Non skid, light coloured, white printed ceramic jointfree/rectified tiles 8 to 10mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and including laid with spacers and pointed with liquid epoxy grout to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Coloured glazed ceramic tiles 600mm x 300mm x 7mm / 450 mm x 300 mm x 7 mm thick on vertical surfaces of walls as in dado, skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over & including 10 mm thick rendering in CM (1:3) complete, all as specified. Note : Decision of GE will be final binding with respect to approval of size of tiles from the above options.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , complete all as specified and directed by Engineer-in Charge.
Description all as per item No 26 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wallnut colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm wallnut colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, and PCC 1:3:6 filling in back recess profile complete all as specified and as directed by Engr-in-Charge.
200mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed by Engr-in- Charge.
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark)
Stainless steel butt hinges (ISI Marked) 'Medium weight' 100 mm size, fixed to steel/angle iron frame by welding , if required, complete all as specified and directed by Engr-in- Charge.
150 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate, fixed to frame, complete all as specified and as directed.
Mild steel, 300 mm, ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified.
Floor door stopper of aluminium alloy long and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length of cover plate 150mm, complete all as specified.
Drapery rod (MS conduit) of dia not less than 22 mm having a corrugated virgin PVC extrusion on it & finials of approved shade with standard MS powder coated/ brackets, fixed to walls with rawl plugs and steel screws, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including cutting chases of wall for concealed pipeline all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
20 mm bore galvanised steel water tubing medium grade (ISI Marked) with and including cutting chases of wall for concealed pipeline all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
25 mm thick flush shutters,solid core construction,with block board core and ply wood face pannels and one face is covered with decorative face veneer with lipping/frame to match all as specified.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in IS-1003 Part-1; supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
35 mm thick flush shutters,solid core construction,with block board core and ply wood face pannels and one face is covered with commercial face with lipping/frame to match all as specified.
Vitreous China wash down water closet pedestal pattern white pan EWC with plastic water closet seat, back, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device accessories set and all fittings, connections including making connection, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. MAKE: Cera Model Combiflush twin flush as per Cat Part No. 2603 or equivalent in performance of makes as specified in PS.
Oval under counter wash basin, white flat back size 560 x 470mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron suitable size embedded in PCC block with PCC 1:2:4 type B-1 and HDPE pipe bend 32mm dia & CP getting with holes, complete all as specified and as directed by Engr-in-Charge. Make: Cera cat part No 1005A(Ivory colour) or equivalent in performance of makes as specified in PS.
Red/black granite (of any type) tiles 16-18 mm thick machine cut, bedded andjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with rounding off/moulding to edge (half round) of stone of any description, such as in steps, cooking platform and other similar situations including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified.
Pillar cock swan neck fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm with adjustable flanges, complete all as specified and as directed by Engr-in-Charge.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by Engr-in-Charge
Chromium plated shower roses with or without swivel joints, 125mm size, including fix into steel pipe or union of bore 15mm complete all as specified and as directed by Engr-in-Charge.
Bib taps long body , cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar Cat Part No CON-037KN or equivalent of makes specified in cera.
Hand shower (health faucet) brass CP with 8mm dia 1.0 meter long flexible tube with wall hook, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar Cat part No ALD - 573 or equivalent of makes specified in PS.
Soap dish fancy type chromium plated fixed with brass screws and wooden/plastic cleats complete all as specified.MAKE Jaquar cat part No-ACN-1131N/ or equivelent aproved.
Aluminium tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs. complete all as specified in repairs. (ISI Mark)
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
PVC connections 15 mm size with PTMT nuts of length 600 mm and washers, complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or laying cables, for shafts, wells, cesspits, manholes, pier holes, for cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 250mm bore pipes all as specified.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed by Engr-in-Charge.
Removal of excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point , complete all as specified and as directed by Engr-in-Charge.
Reinforced concrete pipes 250mm bore ,class NP3,laid and jointed complete with coller all as specified and as directed.
TMT mild steel bars, 8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab, chullah hoods and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in coping,gola etc including all necessary form work, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes/soil pipes (any size, type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., for (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by Engr-in- Charge.
75 mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and as directed by Engr-in- Charge.
PVC (SWR) bend with acess door any radius, for 110 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
PVC (SWR) bend with acess door any radius, for 75 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
PVC (SWR) multi/single floor trap, 75mm diameter of outlet, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engr-in-Charge.
Providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exceeding 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Non skid coloured ceramic tiles of size 400x400mm not less than 7mm thick in floors, etc., set and jointed in neat cement slurry and including laid with spacers and pointed with liquid epoxy grout to match over and including 15 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:4, including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Vitreous China urinal, half stall type, including CP spreader and HDPE waste pipe and bends complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified and as directed by Engr-in-Charge. Make : CERA (Model - URINAL Large 420 x 395 x 635 mm Cat. No. S4020102) or equivalent model of makes specified in PS.
Stop valves, fancy type chromium plated cast copper alloy concealed type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm , fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Angular stop cock/Angle cock with wall flange, fancy type, brass, chromium plated, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixing in repair, complete all as specified and as directed by Engr-in-Charge Make : Jaquar Cat Part No - CQT-23059 or equivalent of makes specified in PS.
S&F 50mm bore High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 including necessary fittings sockets/bends /reducers/Tee etc fixed complete to walls, ceilings or in floors, complete all as specified and as directed by Engr-in-Charge
Vitreous china water closet, 'Squat pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including P or S trap, including PCC lean 1:4:8 type D-2 ,fixed in repais, complete all as specified and as directed by Engr-in-Charge.
75 mm thick, Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base for laying floor finishes including finishing the surfaces even and rough , complete all as specified and as directed by Engr-in-Charge.
Factory made,digital matt finish, paving coloured tiles, heavy duty, size 300 x 300 x 10mm thick laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4, including jointed with neat cement slurry and including laid with spacers and pointed with liquid epoxy grout to match the shade of tiles, complete all as specified and directed by Engineer-in-Charge. Make: Durastone of Somany or equivalent in Bell/Nitco/Johnson/AGL.
Preparation old surfaces including complete removal of existing treatment and applying three coats of white wash on ceiling all as specified
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / fan / bell controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 85 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Description all as per item above No 85 above but but one 3/5 pin 5 Amp socket outlet on independent board .
Description all as per item No 85 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole one way 5 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Supply & fixing Slim linear LED lighting fixture 20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Make SYSKA Ordering Code -SSK-SQ1801 / WIPRO Product Code-D532065/ Havells Ordering Code -LHEXBYPNIN1W020specifications.
Supply & fixing Slim linear LED lighting fixture 10 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Make : Havells cat Pt No LHEWEBP7IN1W010 or equivalent in performance of makes as specified in particular specifications.
LED bulk head luminaire, 10/12 watt surface mounting type extruded aluminium body with diffuser and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells cat Pt No LHEOAOP7UZ6W010, 230V or equivalent in performance of makes as specified in particular specifications.
Supply and fixing LED Street Light fitting 20Watt, New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with acrylic, powder coated, pressure die cast aluminium compact high power LED tube light with heat resistant toughened Glass, Corrosion resistant, isolated driver low heat generating LED (Make of LED shall be CREE/Necia/Osram) including nuts, bolts, washers with suitable size/dia 40mm GI pipe bracket for fixing of street light including making all connection, complete all as per the direction of Engg-in-Charge. Make :SYSKA cat No. SSK-NST-20W or Havells/CG or equivalent in performance of makes as specified in particular specifications.
Note for Srl item Nos 93 to 96 : (i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as per the directions of Engg-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
BLANK
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
MCCB 4 pole,415 volts 160 Amps with breaking capacity 16 KA with thermal adjustble, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
MCB SP, 6 to 32 Amps, 'C' series, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 40 to 63 Amps, 'C' series,240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 'C' series,240 Volts including providing copper thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Supply and fix sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armoured heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 70 sqmm 3.5 core, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose.
Supply and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old pipe, complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 113 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Alishan Builders
KUMAR CONSTRUCTION CO
MADAN LAL SHARMA AND SONS
MAHAJAN TRADING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .