| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹43.9 L+₹94,664 (2.20%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹44.4 L+₹1.4 L (3.37%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹44.8 L+₹1.9 L (4.40%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹44.9 L+₹1.9 L (4.46%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
15 Jun 2024, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
REPAIR/MAINT INCLUDING REPLACEMENT OF DAMAGED FLOOR AND WALL TILES AND ALLIED WORKS, REPAIRS TO FLOORING, SUNKEN AND ALLIED WORKS AT KV AREA, REPAIR / REPLACEMENT OF WATER SUPPLY DISTRIBUTION LINE AND REPAIR/MAINT INCLUDING REPLACEMENT OF OUTDOOR LT
2024_MES_655812_1
C/8764/2024-25/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹84,000
Yes
23 Jul 2024
24 May 2024
22 Jun 2024
24 May 2024
15 Jun 2024
8 Jun 2024
Amount
Demolition of un-reinforced cement concrete of any description not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
Cleaning the surfaces of brick/rcc using wire brush , brooming down and washing down with water to remove dust etc. and brushing with neat cement slurry @0.5 kg/sqm with acrylic based polymer modified cementitous composite (Pidifine 2K) @ 0.50 kg/sqm, complete all as specified and directed.
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed
M&L 10mm thick rendering on fair faces of brick work or concrete surface in CM (1:3) using water proofing compound @ 3% by weight of cement in sunken portion, complete all as specified and directed.
M&L for PCC (1:5:10) type E-2 (using 40mm graded crushed stone aggregate) as in sunken portion, complete all as specified and directed.
M&L 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in sunken portion, complete all as specified and directed.
S&F in repair vitreous china squatting pan ,"Orissa pattern" white, size 580x 440 mm with integral foot rest, 'P' or 'S' trap, including connection to trap, and to flushing pipe, CI anti -syphonage pipe, complete all as specified and directed.
S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm bore, complete all as specified and directed.
M&L in repair PVC(SWR) gully trap, setting and jointing with solvent cement 125/110mm, complete all as specified and directed.
S & F in repairs, cast iron nahani trap 75mm dia with grating including jointing to waste pipe fixed in CM (1:2:4) type B1 (using 20mm graded crushed stone aggregate), complete all as specified and as directed.
S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in let, ball valve, float and handle with and including 32mm dia PVC flush pipe, complete all as specified and directed.
S & F in repairs, 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends, complete all as specified and directed.
Taking down soil/ waste vent and rain water pipes including all fittings of any size and pattern in any position, complete all as specified and directed.
S & F 75mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, fixed to wall with and including clamps, complete all as specified and directed.
S & F 110mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, fixed to wall with and including clamps, complete all as specified and directed.
S&F 110mm bore, PVC (SWR) bends of any radius, complete all as specified and directed.
S&F 75mm bore, PVC (SWR) bends of any radius, complete all as specified and directed.
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed.
S & F 110 mm bore PVC (SWR) junction single (Single `Y') equal or unequal with access door complete all as specified and directed.
Taking down 15mm bore steel water tubing and connection from wall /ceiling in concealed position including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
S&F steel water tubing and connection, medium grade, 15mm bore with all fitting fixed concealed to wall or in ceiling complete and making good surfaces with CM (1:3), complete all as specified and directed.
Re-fixing old steel tubing and connection, 15mm bore, in new or old position with new fittings, complete on wall/ceiling, complete all as specified and directed. (Note : Serviceable steel tube obtained from taking down shall be re-used)
S&F in repair 15mm bore, fancy type, chromium plated, stop valves,concealed type, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repair 15mm bore bib taps, cast copper alloy, chromium plated, two way, long body, fancy type, with capstan head, screwed down, screwed for iron pipe, compelete all as specified and directed.
Taking down cement plaster on brick or concrete wall surface including racking out joints, hacking for key, scrubbing down with water, etc, compelete all as specified and directed.
M&L 15mm thick rendering in CM (1: 6) on fair faces of brick work or concrete surfaces finished surfaces fair and even, complete all as specified and directed.
M & L for rendering 15mm thick (10mm + 5mm) in two coats on fair faces of brick work or concrete surfaces of wall in CM (1:4), mixed with integral water proofing compound at top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item as supply only.)
M&L for rendering 5mm thick in CM (1:3) on fair faces of brick work or concrete surfaces, rendering finished even and smooth (without using extra cement) as in ceiling, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whiting primer, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistance primer, complete all as specified and directed.
M&L for 40mm thick, PCC (1:2:4) type B-0, (using 12.5mm graded crushed stone aggregate) as in alternate bays and finished the surface even and smooth using extra cement, complete all as specified and directed. Note- Glass strips shall be measured and paid separately.
M&L for 38mm deep glass dividing strips, 3mm thick inserted in position, conform to design, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backin), removing serviceable tiles to store and rubbish off the premises, complete as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
All as per item No 35 here-in-before but as in skirtings/Dado incl rendering 10mm thick in CM (1:4) as backing coat to receive wall tie, complete all as specified and directed.
M&L glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering back coat in CM (1:4), complete all as specified and directed.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in deep for foundation etc. or for shaft, wells, cesspits, manhole, pair house etc. n. exc. 10 Sqm on plan and getting out in any type of soil, complete all as specified and directed.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Cutting of road/hard standing plinth protection of building/path for laying of pipe line of any size, complete all as specified and directed.
Taking up or down 80mm bore steel water tubing and connection from wall/ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
Taking up or down 50mm/40mm bore steel water tubing and connection from wall/ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
Taking up or down 25mm bore steel water tubing and connection from wall/ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
Taking up or down 20mm bore steel water tubing and connection from wall/ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
S&F CPVC pipe of size 75mm bore in trenches high pressure CPVC pipes shedule 40 pipes and plain CPVC shedule 80 fittings including all necessay fittings, like elbow, tee, socket, seducer, bushings, step over bends, end caps, end plugs, etcand with CPVC solvents cement, complete all as specified and directed.
S&F CPVC pipe of size 50mm dia in trenches high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc and with CPVC solvents cement, complete all as specified and directed.
S&F CPVC pipe of size 40mm dia in trenches high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc and with CPVC solvents cement, complete all as specified and directed.
S&F CPVC pipe of size 25mm dia in trenches high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc and with CPVC solvents cement, complete all as specified and directed.
S&F steel water tubing and connection, medium grade, 25mm bore with all fitting fixed to wall and ceiling or laid in floor, complete all as specified and as directed.
Re-fixing old steel tubing and connection, 25mm bore, in new or old position with new fittings, complete on wall, ceiling, floors etc, complete all as specified and directed. (Note : Serviceable steel tube obtained from taking down shall be re-used)
S&F steel water tubing and connection, medium grade, 20mm bore with all fitting fixed to wall and ceiling or laid in floor, complete all as specified and as directed.
Re-fixing old steel tubing and connection, 20mm bore, in new or old position with new fittings, complete on wall, ceiling, floors etc, complete all as specified and directed. (Note : Serviceable steel tube obtained from taking down shall be re-used)
M & L for PCC (1:3:6) type D2 (using 40mm graded crushed stone aggregate) complete for making good to the excvated portion of road/hard standing/plinth protection of building etc, complete all as specified and directed.
M & L for cutting existing steel tubing of size 40/50mm for alterations or additions (each cut measured), complete all as specified and directed.
M & L for screwing existing steel tubing of size 40/50mm for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and directed.
S&F gun metal gate valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe of 50mm bore including taking down old unsrviceble gate valves, complete all as specified and directed.
S&F gun metal gate valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe of 40mm bore including taking down old unsrviceble gate valves, complete all as specified and directed.
S&F gun metal gate valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe of 32mm bore including taking down old unsrviceble gate valves, complete all as specified and directed.
S&F gun metal gate valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe of 25mm bore including taking down old unsrviceble gate valves, complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head, screwed both ends suitable for fixing with CPVC/GI pipe of 20mm bore, complete all as specified and directed.
S&F in repair CPVC ball valve of size 50mm dia suitable for CPVC pipe, complete all specified and directed.
S&F in repair CPVC ball valve of size 25mm dia suitable for CPVC pipe, complete all specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete for base support frame for water tanks at roof top/ground floor including dismantling of old cross arms, bracings, supports etc, complete all as specified and directed.
Supply, fabricating. installing., testinging and commissioning of outdoor type LT feeder pillar box of suitable size factory fabricated, cubical panel, wall/floor mounted single door, dust and vermin proof CPRI approved made out of 3. 15 mm thick CRCA sheet alongwith both side cable alley of width not less than 200 mm each side for termination of cable with provision for top and bottom cable entry mounting on 50x50x5mm Angle iron supports at the base wiht coper busbar of capacity 400 Amp, duly painted with synthetic |enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring. necessary cable glands, lugs etc. proper arrangement for ventilation with and including the following accessories including taking down old unserviceable LT panel/feeder pillar box of any size:- INCOMING (i) MCCB 200 Amps, AC 4 pole 415 Volt 36 KA Breaking Capacity thermal magnetic release range 200-250A, with suitable rotary extendable handle for operation of MCCB-01 No. OUTGOING (i) MCCB 100 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release 80-100A, with suitable rotary extendable handle for operation -03 Nos. (ii) MCCB 63 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 63-80A, with suitable rotary extendable handle for operation - 03 Nos (iii) lsolator four pole 80 Amp- 04 Nos. (iv) MCB SPN 63 Amp, "B" Curve, 10 kA - 08 (v) Digital voltmeter with all accessories for incoming (vi) Digital ammeter with all accessories for incoming & each outgoing (vii) Phase indicating lamp LED Type (R-Y-B) for incoming and each outgoing connections
Supply, fabricating, installing, testingng and commissioning of outdoor type LT feeder pillar box of suitable size factory fabricated, cubical panel, wall/floor mounted single door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet alongwith both side cable alley of width not less than 200 mm each side for termination of cable with provision for top and bottom cable entry mounting on 50x50x5mm Angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories including taking down old unserviceable LT panel/feeder pillar box of any size : INCOMING (i) MCCB 630 Amps, AC 4 pole 415 Volt 50 KA Breaking Capacity thermal magnetic release range 500-630 Amp with suitable rotary extendable handle for operation -02 Nos.(one working & one spare) (ii) On-Load changer over panel mounted open execution type 4 pole, 630 Amps, AC, 415 Volt with extended suitable handle for two source DG Supply and two source main supply including interlocking between supply- 02 Nos. OUTGOING (i) MCCB 400 Amps, AC 4 pole 415 Volt 36 KA Breaking Capacity thermal magnetic release range 320-400, with suitable rotary extendable handle for operation- 02 Nos. (one working & one spare) (ii) MCCB 250 Amps, AC4 pole 415 Volt 36 KA Breaking Capacity thermal magnetic release range 200-250, with suitable rotary extendable handle for operation -02 Nos.(one working & one spare) (iii) MCCB 160 Amps, AC 4 pole 415 Volt 36 KA Breaking Capacity thermal magnetic release range 200-250 with suitable rotary extendable handle for operation -02 Nos (iv) Isolator Four pole 80 Amp - 06 Nos., (v) MCB SPN 63 Amp, "B" Curve, 10 kA - 08 Nos. (vi) Digital voltmeter with all accessories, (vii) Digital ammeter with all accessories (viii) Phase indicating lamp LED Type (R-Y-B) for incoming and each outgoing connections
M&L for earthing complete with GI earth plate elecrode of size 600mm × 600mm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip 32 mm x 6mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work pre-cast RCC(1:2:4) type B-1 pit cover 50mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10mm dia TMT bar embedded in precast cover slab and PCC(1:2:4) type B-1 concrete pit and angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect, protected by 40mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed. Note: (i) Proper earthing pit should be provided with pit cover. (ii) Cost of GI strip from earthing to LT panel/bus bar shall deemed to be included in the unit quoted rate.
Supply, fabricating, installing, testing and commissioning of outdoor type LT bus bar box of size not less than 900 mm (L) x 900mm (b) x 450mm (d) of suitable size factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounting on 40x40x5mm Angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size cable glands, lugs etc, proper arrangement for ventilation including taking down old unserviceable bus bar box of any type and size, complete all as specified and directed.
Taking down/out unserviceable UG cables of any cross sectional area and connections including bricks, GI pipes, etc of any descriptions, laid in trenches and/or fixing with walls/poles, complete all as specified and as directed.
Relaying of serviceable LT UG cable carefully of any cross sectional area and connections including inserting into new DWC pipe, laid in trenches and/ or fixing with walls / poles, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
M&L for 80mm bore GI tubing, light grade, with necessary fittings such for cable protection, laid in trenches, complete all as specified and directed. Note: Excavation earth work shall be measured and paid separately.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminimum conductor, 1100 Volts grade, in trenches/fixed on wall for cross- sectional area of cable of size from 185 Sqmm 3.5 core, complete all as specified and directed. Note: Excavation earth work shall be measured and paid separately.
Horizontal boring under the road (with manual method) below 1m from the road surface and dia of hole not exc. 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed.
Note: An amount of Rs.58,825.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
BHARAT ELECTRIC
M/S BIJAY KUMAR SHIVA
B L SHARMA
M/S SARDAR MAL NAHATA
M/S. NARENDRA KUMAR GARG
M/S RATHIN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .