| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.0 LAccepted-AOC Y 49 Y BLOCK HAUZ KHAS SOUTH WEST DELHI NEW DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹53.9 L+₹88,374.01 (1.67%)Rejected-Finance | L2 | Rejected-Finance L2 bidder | |
| 3 | L3₹56.8 L+₹3.8 L (7.08%)Rejected-Finance | L3 | Rejected-Finance L3 bidder | |
| 4 | L4₹57.6 L+₹4.6 L (8.72%)Rejected-Finance | L4 | Rejected-Finance L4 bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Apr 2021, 5:00 pmClosed
Executive Engineer
Estate Office, CCS HAU, Hisar
Construction of lecture hall/examination hall and Under Graduate Lab adjoining to the existing building of College of Fisheries Science at CCSHAU, Hisar (including PH and EI works)
2021_HRY_166698_1
3212
Open Tender
Civil Works
Works
180 days
CCS HAU
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
₹1 L
Yes
2 Jun 2021
30 Mar 2021
12 Apr 2021
30 Mar 2021
8 Apr 2021
30 Mar 2021
Amount
Civil work 1 to 84:- Earth work excavation in ordinary soil exclusive of compensation of earth- {HSR 6.2 (b)} (b) Earth-work undressed with a combined lead upto 15 metres including breaking of clods
Dressing of earthwork :- (i) New work or remodelling work {HSR 6.3(i)}
Earth work in excavation in foundations, trenches, etc .in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches ,stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres (HSR 6.6)
(a) Earth filling under floors with surplus soil, excavated from foundation and taken only from outside the building plinth, in 15 cm layers, including ramming watering and consolidating lead upto 30 metres {HSR 6.13 (a)}
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 m and lift upto 1.5 m. (a) soft/loose soil {HSR 6.25 (a)}
Extra for centering and shuttering for sides and soffits of beams haunchings. Girders, bressumers and lintels. {HSR 9.7 (45% of labour rate)}
Extra for smooth exposed concrete finish as desired which is not to be touched or plastered but is to be left as it comes out of the shuttering for columns (square or rectangular or polygonal in plan) {HSR 9.9(45% of labour rate)}
Extra for smooth exposed concrete finish as desired which is not to be touched or plastered but is to be left as it comes out of the shutting for corbel, parapets, fascias and other similar items.(45% labour rate of item No. 9.11)
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth. (HSR 10.28)
Cement concrete 1:4:8 with stone aggregate 40 mm nominal size in foundation and plinth (HSR 10.39)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59)
Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work , placing and fixing in position, complete at the ground level or in first storey (HSR 10.77)
Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in tiles and channels and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete at the ground level or in first storey (HSR 10.78)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects (HSR 10.81)
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects. (HSR 10.82)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. (HSR 10.86)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by item nos. 10.82,10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centring and shuttering , laid in position, complete in all respects (HSR 10.89)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects, (For work upto 1.5 metres below ground level) (HSR 10.90)
(a) Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 {HSR 10.95 (a)}
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with 2 coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded. (HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth (HSR 11.2)
First class brick work laid in cement sand mortar 1:4 in foundation and plinth (HSR 11.4)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7+ Note) Ist Storey
2nd Storey
11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure {HSR 11.48(a)}
11.43 cm thick brick wall with every fourth course reinforced with hoop-iron laid in 1:4 cement stone dust (from crusher) mortar in superstructure. (HSR 11.51)
11.43 cm thick brick wall laid in cement stone dust (from crusher) mortar 1:4 in superstructure (HSR 11.53)
Providing 5.72 cm brick dalli facing with brick size 22.86 cm X 11.43 cm X 5.72 cm thick to be obtained after cutting of bricks laid in cement sand mortar 1:3 on RCC lintels, beams fascia etc. including centring and shuttering complete. (HSR 11.98)
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)
Providing and fixing cast iron rain water non pressure pipe, I.S.I. mark with ears with screw and wooden plugs fixed on wall face including filling joints with spun-yarn and cement mortar 1:2 excluding head and shoe, etc. {HSR 13.45(a)} (a) 100 mm dia pipe
Extra over rate of item nos. 13.43 and 13.45(a) in case lead joints are used instead of cement joints {HSR 13.46(a)}
Providing and fixing C.I. plain bends in position with gutter, etc. {HSR 13.49(a)} (a) for 100 mm dia pipe
Top khurra 0.6 m X 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13..50)
Bottom khurra on ground 1.2 m X 0.6 m consisting of brick-on-edge laid in cement mortar 1:3 over 75 mm cement concrete 1:8:16 including 12 mm thick cement plaster 1:3 (HSR 13.57)
Cement concrete 1:2:4 gola 10 cm X 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64 )
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round gavanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvazied mild steel item (galvanizedd @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre of centre along main 'T'. The suystem should rest on periphery walls/partitions with the heop of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling (HSR 14.1)
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in flooring laid in any patterns as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles {HSR 14.89} Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in skirting / dado laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles {HSR 14.90} Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 ( {HSR 14.92 (b)} (b) Size of ceramic glazed tiles 300 mm x 450 mm
Providing edge moulding to 17-20 m thick granite stone counters, vanities etc. including machine polished to edge to give high finish etc. complete as per design apprvoed by Engineer-In-Charge (Moulding) {HSR 14.98 (i)} (i) Single moulding
12 mm thick cement plaster 1:6 on walls (HSR 15.7)
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12) Ist storey
2nd Storey
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52)
Cement pointing 1:2 deep variety on brick and tile work (HSR 15.60 )
Cement pointing 1:2 flush on flat brick flooring (HSR 15.71)
Cement pointing on stone slab pavement with cement mortar 1:2 (HSR 15.73)
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :- (HSR 15.77 (a) Vertical
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :-{HSR 15.77 (b)} (b) Horizental
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead , linseed oil, varnish and chalk mitti including finishing the surface to required finish complete (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping, etc. (HSR 16.2)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.3)
Applying priming coat with metal primer on new steel or iron work including preparation of surface (HSR 16.9)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Providing two coats of exterior acrylic emulsion paint . {HSR 16.79 (b)} (b) 1st quality
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Proving and fixing 35 mm thick glazed door and windows shutters of commercial hard wood such as hollock, champ, chikrassy and chaplash, etc.. (Based on HSR 17.30 (a) + 17.24 (c ) (a) 35 mm thick ( 4 mm thick glass panes)
Providing and fixing 12 mm thick and 150 mm wide pelmet of commercial ply wood without 25 mm dia teak wood curtain rod and brackegts including fixing with 25 mm x 3 mm M.S. flat, 10 cm long and plugs. (Teak) etc. complete. {HSR 17.63 (-) 17.89 (c)}
Providing and fixing 150 mm hasps and staples with necessary screws, etc., complete- (HSR 17.78(b) (b) aluminium
Supplying and fixing hydraulic door closer, I.S.I. mark, with necessary screws , etc., complete- {HSR 17.82 (c )} (c) I.S.I. designation No. III ( size of door 851 mm to 1000 mm)
Providing and fixing sliding bolt with nuts and screws, etc., complete. {HSR 17.83 (b) (ii)} (b) Aluminium (ii) size 250 mm X 16 mm
Factory manufactured solid flush door shutters, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops, etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- (a) commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminated core and lipped edges :- {HSR 17.93(a)} (i) 25 mm thick
(iii) 35mm thick
Wrought iron and mild steel (using angles, flats square bars. tees and channels) ladders, grills, gratting frames, window guards, iron door openable or fixed stair case or parapet or any other type of railing , gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Supplying openable steel doors and windows, of standard steel sections (HSR 18.24)
Fixing steel windows in walls with lugs, embedded in 15 cm x 11.43 cm X 7.5 cm cement concrete blocks, of 1:3:6 mix, excluding fixing of glass panes but including cost of cement concrete for lugs (HSR 18.29)
Supplying and fixing glass panes including special metal sash putty of approved make {HSR 18.30 (b)} (b) Glass panes 4 mm thick, exceeding 40 sq dm areas
Providing and fixing 15 mm to 18 mm thick Z-black granite stone (polished) on worktop including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete (NS)
Providing and fixing C.I. grating over 100 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Earth filling under floors with dune sand (tibba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete. (NS)
Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continous chemical barrier under and all round the column pits, wall trenches, basement excavation, top surface of plinth filling junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits etc., complete as per PWD specifications (plinth area of the building at ground floor only shall be measured of payment (NS) (The material i.e. Chlorphriphos Emulsifiable concentrate 20% with 1% conentration shall be arranged by the contractor)
Providing and fixing 19 mm thick BWR grade-II block board (ISI mark) of approved make shutters for cabinet including cost of iron hinges, screws etc. complete fixed in position but excluding cost of primer and paint. (NS)
Providing and fixing 20 mm dia stainless steel pipe of 14 guage as curtain rod including brackets, screws etc., complete in all respects as directed by Engineer-in-Charge. (NS)
Providing and fixing 25 mm dia fancy curtain rods of Vista make including cost of brackets, nails, screws, gutties /rawl plugs, fancy rings etc., complete in all respects. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in flooring including matching grains laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in skirting including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing writing desk 1’-7/8” wide consisting of following (1st row) :- (i) Steel frame work not taken in this item and shall be paid separately (ii) Wood work (a) Top portion consisting of 25 mm thick commercial type block board of approved make finished with 1.0 mm thick plastic laminated sheet of approved make, shade & colour (ISI mark) Shisham wood beading/ edging of size 3” x ¾” on all sides as per architectural drawing and design (b) FRONT PORTION Consisting of 2’-0” high paneling with well seasoned shisham wood strips of size ¾” x 3” (vertical) with ¼” wide groove (ship lap joint) fixed over steel frame with screws, complete in all respect as per architectural drawing and design. Including cost of screws, nails, adhesive spirit polishing and drilling holes in steel frame etc.
Providing and fixing seating arrangement (bench-cum-desk middle row) consisting of following:- (i) Steel frame work not taken in this item and shall be paid separately. (ii) WOOD WORK (a)BENCH – SEATING PORTION Consisting of 4 Nos. shisham wood strips of size 3.1/4” x 1” and 1 No. strip of size 3¼”x 1¼” on 1’-5” wide horizontal portion and 5 Nos. shisham wood strips of size 3¼” x 1” on vertical/ back portion with 1/16” wide groove (ship lap joint) fixed with screws/ nails etc. in the steel frame along with shisham wood beading/ edging of size 1 ½” x ¾” on front edge (b) DESK – WRITING PORTION (1’-7/8” WIDE) Consisting of 25 mm thick commercial type block board of approved make finished with 1.0 mm thick plastic laminated sheet of approved make, shade & colour (ISI mark) along with shisham wood beading / edging of size 3”x ¾” on three sides/ edges (except front side), fixed in frame with screws/ nails etc. complete the job in all respect as per architectural drawing and design including cost of screws, nails, fevicol, spirit polishing and drilling holes in the steel frame etc
Providing and fixing seating arrangement (bench only last row) consisting of following:- (i) Steel frame work not taken in this item and shall be paid separately. (ii) WOOD WORK (a) BENCH SEATING PORTION Consisting of 4 Nos. shisham wood strips of size 3.1/4” x 1” and 1 No. strip of size 3¼”x 1¼” on 1’-5” wide horizontal portion and 5 Nos. shisham wood strips of size 3¼” x 1” on vertical/ back portion with 1/16” wide groove (ship lap joint) fixed with screws/ nails etc. in the steel frame along with shisham wood beading edging of size 1 ½” x ¾” on front edge (b) BACK TOP PORTION (0-3”/ 0’-4” WIDE) Consisting of 25 mm thick commercial type block board of approved make finished with 1.0 mm thick plastic laminated sheet of approved make, shade & colour (ISI mark) along with shisham wood beading / edging of size 3”x ¾” on three sides/ edges (except front side), fixed in frame with screws/ nails etc. complete the job in all respect as per architectural drawing and design. Including cost of screws, nails, fevicol, spirit polishing and drilling holes in the steel frame etc.
Public health work 85 to 118:- Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawing including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimension, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc., night signals, profiles, pegs, sight rails, boning rods, crossing over trenches, for access to the houses, watching, fencing, etc., fixing and maintenance of caution boards, refilling of trenches, watering of refill, in 15 cm layers, ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, up to a lead of 1 K.M. in ordinary soil {HSR 6.10(a)} (a) for depth of excavation not exceeding 3 metres below ground level
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth.(HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41)
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. {HSR 28.18(b)} INCLUDING COST OF SPECIALS (i) 15 mm internal diameter of pipe line
(ii) 20 mm internal diameter of pipe line
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. (HSR 28.21) (a) 15 mm dia
(b) 20 mm dia
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 28.24 (b) (b) 22.86 cm thickness wall
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including repointing, replastering, replacing bitumen and colour or white washing where required. {HSR 28.26(b)} (b) 115 mm thickness of roof of floor
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. {HSR 28.29 (b)} (b) 20 mm internal diameter
Making connection with the existing G.I branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 28.34)
Constructing brick masonry inspection chambers sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/C.C. topping. 50 mm thick with 455 mm x 455 mm/ 455 mm x 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. {HSR 29.84(a)} (a) size 450 mm x 450 mm in side ( with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg. With C.C. topping )
Extra for over 0.30 meter depth of inspection chamber:- {HSR 29.85 (a)} (a) 450 mm x 450 mm
Providing slat glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with is: 651 and their lowering, cutting, jointing and testing as desired in HSR item No. 29.38, 29.39, 29.40, including the cost of jointing materials as well as carriage, loading, unlloding stacking, handing, re-handling etc. complete in all respects to the satisfaction of Engineer-In Charge. (HSR 29.95) 150 mm internal dia
Providing and fixing in position best Indian make vitreous chinaware sinks with complete fittings as fully described in item no. 30.51 above (HSR 30.52) WHITE (a) 600 mmx450mmx200mm
Providing and fixing in position best Indian make vitreous chinaware laboratory singks (to the approval of the Engieer-in-charge) (HSR 30.60) WHITE (f) 530 mm x 350 mm x 180 mm
Providing and fixing 40mm G.I waste pipe embedded in walls or lead waste pipe weighing 4.46 kg/ metre and 3.0 mm thick up to floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)
Providing and fixing in position best Indian make shower with 15 or 20 I/d out let. {HSR 30.66(c )} (c) C.P. brass with revolving joint
Providing and fixing in position 15 mm i/d C.P brass bib cocks of best quality ( as required by the Engineer-in-charge) {HSR 30.75(a)} (a) Bib cock lond body.
Providing and fixing 15mm C.P brass laboratory cock swan neck of best quality ( to the approval of the Engineer-in-charge) (b) Two way (HSR 30.78)
Cutting chase in brick walls in cement or in floor for embedding G.I. or H.C.I. pipe lines and making good the same to its original condition {HSR 30.95(a) (a)size 75 mm X 75 mm
Providing and fixing in position automatic brass ball valves in tanks {HSR 30.110 (b)(ii)} (b) WITH PLASTIC BALL (ii) 20 mm internal diameter
Providing and fixing HDPE WATER STORAGE TANKS of sintex, diplas O.K. Supreme make with covers/ lids marked with IS: 12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow & scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction of Engineer-in- Charge. (HSR 30.119) 1000 Ltr. Capacity
Supply of GI pipe 'B' Class ISI Marked Ravindra/Jindal/Parkash(Surya) Make. (NS) (a)15 mm i/d
(b)20 mm i/d
Supply of GI Union Couplings of UNIK/UNCO make . (NS) (a)15 mm i/d
(b) 20 mm i/d
Supply of Gun Metal Peet Valve ISI Marked of DRP/Leader/Bajaj make (NS) (a) 20 mm i/d
Supply of PVC pipe 6 kg/cm² pressure of ISI marked of Prince / Supreme/Skipper make (as approved by the Engineer-in-Charge). (NS) a) 90 mm i/dia (3” i/dia) size
Supply and fixing of PVC floor traps (Heavy duty) of 80mm i/dia (3" i/dia) outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)
Providing and installation of self contained drinking water cooler of fully stainless steel body (FSS) with refrigerant R-134 A, cooling capacity 120 liters per hour and storage capacity 120 liter suitable on operating power supply 230 ± 10 %, 50-Hz single face AC complete in all respect. Make = Usha/Voltas/Blue star as approved by the Engineer Incharge (N.S.)
Providing and fixing in position R.O.water purifier (to be fixed with water cooler) having at least 50 ltrs./hour purification capacity and fully automatic operation with auto start and auto off system and as per complete specification of the manufacturer complete in all respect. (NS) Make:- KENT-ELITE Model.
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (NS)
Electrical work 119 to 1 Supplu and erection of blanking sheet in existing distribution board (HSR 31.16)
MINIATURE CIRCUIT BREAKER AND ISOLATOR:(HSR 31.17) Supply and erection of miniature circuit breaker/isolator 240/415 V in the existing distribution board including making necessary connections (a) Miniature Circuit Breakers of 9 K.A. breaking capacity (ii)6-32 amp. SP MCB
(ii) 32 amp. TPN MCB
(ii) 63 amp. TPN MCB
Supply & erection of fittings & accessories: (HSR 31.18) (xxvi) S/E of hexagonal M.S. box 1.60mm thick having each side 8 cms., 7.5cms deep, top covered with M.S.lid by means of screws including 10 mm dia 30cm long mild steel rod made into suitable suspension hook and erected in RCC slab.for erection of fan, the bottom covered with 3mm thick bakelite sheet with suitable holes, painting etc. complete with all labour and material required to complete the job.
PIPE LAYING: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required :-(HSR 31.21) (xxx) S/E of PVC pipe of 6 Kg. pressure, laid 1 metre below ground level complete including digging refilling of the trenchy with jointing etc. (a) PVC pipe 65mm dia.
EARTHING (HSR 31.22) (i) Earthing with G.I. earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required
(ii) Extra for charcoal or coke and salt for pipe earth electrode.
(xii)Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15mm dia G.I. pipe from earth electrode as required.
UNDERGROUND CABLES Supply and erection of underground cable loose in existing pipe or trenches complete with necessary connections.(HSR 31.26) (xli) 4 x 25 sqmm(armoured)
(xliii) 4 x 50 sqmm(armoured)
S/E of suitable compression type brass cable glands for underground cable (HSR 31.28) (iii) 25 sqmm to 50 sqmm cable 3 to 4 core.
BUS BAR CHAMBER (a) copper S/E of metal clad bus bar chamber made from 1.6mm thick M.S. sheet fixed with rag bolts on wall or on existing pedestal/angle iron frame including bonding to earth, detachable top and bottom painting and necessary connections etc.(Copper bars duly tinned).(HSR 31.31) (ii) 100 amp. 4 bars of 55 cm each (cross section 25mmx3mm), chamber over all size 60 cm x 45cm x 18 cm
Miscellaneous (HSR 31.35) (i) Supply of M.S. Pipe (B-Class) for suspension rod of ceiling fan including threading if required. (a) 15mm dia
(ix)Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of Engineer-in-charge of the work. (e) 25 sqmm
(g) 50 sqmm
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe (HSR 31.40) (i) Size 1.5 sqmm(3/0.81mm)
(ii) Size 2.5 sqmm(3/1.05mm)
(iii) Size 4 sqmm(7/0.85mm)
(v) Cable size 10 sqmm(7/1.35mm)
S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. Recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer-in-charge of the work (HSR 31.41) (v) 4-wat TPN (Horizontal) (8+12)
(vi) 8-way, TP&N (Horizontal) (8+24)
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work (HSR 31.44) (ii) 25mm dia
S/E of 50mm dia 1.5 mtr long GI bracket (B-class) making an angle 10 to 15 degree with horizontal plane for mounting street light.(HSR 31.53)
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 31.56) 10 amp. 1 way switch
20 amp.switch
10 amp. Socket
16 amp. socket
Fan regulator
Blinkng plate
Pdg. and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 31.57) 1 & 2 Modules
3 Modules
6 Modules
12 Modules
Supply, installation testing and commissioning of wall/free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3mm thick for separately cable alley to BBC from switch chamber extended solid copper bars upto cable alleys shall provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection (Only outer area on all sides shall be measured) (HSR 31.63)
Supplying and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (HSR 31.64)
Suppluy and erection of module case circuit breaker single pole/4 pole on wall on existing prdestal including boundaing to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction oof the Engineer-in-charge of work (HSR 31.69) (iv) 4 pole MCCB 6amp. to 63 amp
S/E/T/C of multicore telephone conductor 0.5 mm complete in all respect. ( HSR 31.78 ) i ) 2 Pair Telephone
S/E/T/C of cat-6 cable in existing PVc conduit /PVc channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 31.80)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator etc. {NS} i) 1200mm sweep. Make: Usha, Orient, Crompton.
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)
S/E of LED Street Light of system voltage < 70/72watt IP66 Multiple LED with Lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen < 72watt LED should be 7700 or above in cool day light 5700K Lumen efficency > 110lm/w. Power Factor >.95 with connections street light / PCC Poles with Bracket i/c 3 year defect liability period and free replacement in case of non functioning of the light fixture Make Philiphs , Havell's , Wipro,Bajaj , HPL (NS)
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5600K to 6500K), Power factor >0.95, CRI (Ra) >80, LED Lamp efficiency ≥ 140 lm/w, Average life > 50000 hours, complete with all accessories as required with connections (Industrial) Make: Havells (NS)
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Nos.(ii) Air flow (CMH) -1450 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D + 3D Auto etc. complete in all respectMAKE :- O General/Toshiba/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge. (NS)
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
Supply Installation testing & commissioning of 24 Port POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Switch should offer Wire-Speed and Non-Blocking Switching with 24 10/100/1000 RJ45 PoE/PoE+ Ethernet ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port Populated with 10G MMF. Access switch should support minimum 16K MAC addresses and minimum 4K active VLANs. Access switch should support up to 8 hardware queues per port Access Switch should support full Layer 2 features like STP, RSTP, LACP, ACL, QoS, IGMP v1/v2 from day 1. Access Switch should support minimum 1K IPv4 routes.The Access Switch should support IPv6 management features like IPv6 ping, IPv6 trace route, IPv6 Telnet, IPv6 TACACS, IPv6 and IPv6 RADIUS.Access switch should support minimum 4K ACL rules ACL per Switch.Access switch should support SNMP v1/v2/v3, SSH, NTP and web managementAccess switch should have 1G of RAM and 2G of Flash Memory.MAKE : RUCKUS/CISCO/HP (NS)
Supply Installation testing & commissioning of 10GBASE-SR,SFPP MMF LC CONNECTOR with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : BROCADE/CISCO/HP
Supply Installation testing & commissioning of SL Series Category 6 Modular Jacks, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of Category 6 Patch Cord 7feet, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of 24Port loaded Straight Jack pannel, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of 18U Wall Mount rack with front glass door lockable, Fans 90 Cfm 230 Vac, PDU Horizontal 5Amp with 6 Schokets, Cantilever Tray-1U, Horizontal PVC Cable Manager and Hardware front panel Mtg. including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/NETRACK/VPRO (NS)
Supply Installation testing & commissioning of AP Management License with 3 years comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : RUCKUS/CISCO/ARUBA (NS)
Supply Installation testing & commissioning of Indoor Access Point with secure Mounting Bracket and with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : The Access Point should have 2 auto MDX, auto-sensing 10/100/1000 Mbps RJ-45, with POE support on one port, and one USB port. AP should be IOT ready from day 1. The APs should support the IEEE 802.11a, 802.11b, 802.11g , 802.11n & 802.11ac Wave2 standards. It should support minimum 3 MU-MIMO clients simalteniously. The AP must support Dual Band Concurrent Operation - 2.4GHz and 5GHz. Should support 3 spatial streams on both radio bands for an aggregate capacity of 1.75 Gbps including 450Mbps on 2.4Ghz.The access points should be centrally managed. In some small isolated environments the AP should be able to function as a full-fledged stand-alone access point without the requirement of a controller.Security mechanisms should be in place to protect the communication between the Access Point controller and the Access Points.Since most radio interference come from the WLAN network itself the vendor should specify what mechanisms such as beam steering/ adaptive antenna technology/ beamforming are available in combination to focus the energy on the destination STA and minimize radio interference with the surrounding of the AP. The vendor should specify if the activation of such feature is still compatible with 802.11n spatial multiplexing. Since the WLAN network will be using an unlicensed band the solution should have mechanisms that reduce the impact of interference generated by other radio equipment operating in the same band. The access point should be able to detect clients that have dual band capability and automatically steer those client to use the 5GHz band instead of the 2.4GHz band.The antennas to be dual polarised and should be integrated inside the access point enclosure to minimize damage and create a low profile unit that does not stand out visually. The access point should support 802.1q VLAN tagging.The access point should support WPA2 enterprise authentication and AES/CCMP encryption. AP should support Authentication via 802.1X and Active Directory. Implement Wi-Fi alliance standards WMM, 802.11d, 802.11h and 802.11e .The Access Point should provide for concurrent support for high definition IP Video, Voice and Data application without needing any configuration. This feature should be demonstratable. AP should provide minimum 23 dBm Radio output power for 2.4Ghz and 5Ghz both. (EIRP should be limited as per govt regulation for indoor AP's).Should support Transmit power tuning in 1dB increments in order to reduce interference and RF hazards .Device antenna gain (integrated) must be at least 3dBi and should provide automatic interference rejection of about 10dB.Upto 16 BSSIDs per AP for multiple differentiated user services (e.g. voice). should support upto 500 clients per AP. Should support IPv4 and IPv6 from day one. The access point should support following security mechanism: WEP, WPA-PSK, WPA-TKIP, WPA2 AES, 802.11i. System should support Authentication via 802.1X, local authentication database, support for RADIUS and Active Directory.Mechanism for physical device locking using padlock /Kensington lock / equivalent. Operating Temperature: 0°C - 40°C, Operating Humidity: upto 95% non-condensing. Should be UL 2043 plenum rated and comply to WEEE/RoHS. Should be EN 60601-1-2 Medical compliant. (MAKE : RUCKUS/CISCO/ARUBA) (NS)
CCTV:-Supply Installation testing & commissioning of 4MP IP Network Dome Camera with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Image Sensor : 1/3” 4 Megapixel Progressive scan CMOS sensor or better ,Effective Pixels : 2688(H)x1520(V)) or better , Electronic Shutter : Auto/Manual, 1/3(4)~1/100000s, Scanning System : Progressive , Mini. Illumination : 0.08Lux/F2.0(Color); 0Lux (IR on), S/N Ratio : More than 50dB , Min. IR LEDs Length ≥50m, Day/Night : Auto(ICR) / Color / B/W,Back Light Compensation : BLC / HLC / WDR(120DB) ,White Balance : Auto/Natural/Street Lamp/Outdoor/Manual ,Motion Detection : Off/On (4Zone, rectangle),Focal Length : 2.8mm,Angle of View : H: 104° ,V: 57° ,Video Compression : H.265+/ H.265 ,Resolution : 4MP (2688x1520)/3MP(2304x1296)/ 2MP(1920× 1080)/720P(1280× 720),Frame Rate (3 Stream) : Main stream (4MP (1 ~ 25/30fps)) & Sub stream : D1(1 ~ 25/30fps)& Third Stream : 720P (1 ~ 25/10fps),Digital Zoom : 16x,Bit Rate : H.265: 14 ~ 9984Kbps,Network Ethernet : RJ-45 (10/100Base-T) ,Protocol : HTTP; HTTPs; TCP; ARP; RTSP; RTP; UDP; SMTP; FTP; DHCP; DNS; DDNS; PPPOE; IPv4/v6; QoS; UPnP;NTP; Bonjour; 802.1x; Multicast; ICMP; IGMP; SNMP,SD Card : Min 128GB SD card support,Power Supply : DC12V, PoE (802.3af),Working Environment : -30°C~+60°C / Less than 95%RH (no condensation),Ingress Protection : IP67 ,Audio Interface : Built-in-Mic,Intelligence (IVS) : Tripwire, Intrusion, Object Abandoned/Missing ,Advanced Intelligent Functions : Face Detection MAKE : DAHUA/PANASONIC/HONEYWELL/HYUNDAI (NS)
Supply Installation testing & commissioning of Video Management Server with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : MAKE : DAHUA/PANASONIC/HONEYWELL/HYUNDAI (NS)
Supply Installation testing & commissioning of outdor 4*4 box with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : STRONGER/MOLEX/AMP) (NS)
Supply Installation testing & commissioning of 6TB surveillance hard disk with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : WD-PURPLE/SEGATE (NS)
Supply, Installation, Testing & Commissioing of 86" interactive flat panel, IR touch technology, IPS Panel UHD Native Resolution ( 3,840 x 2,160), Brightness 330 Nits; Contrast ratio 1100:1, response time :8ms, Orientation Landscape CONNECTIVITY (Input) Video / Audio HDMI (3), RGB / Audio In(Input) External Control RS232C In, RJ45 (Input) USB USB 2.0 (3, Front : 2ea, Bottom side: 1ea Only for software update), USB 3.0 (3), Touch Out(USB2.0,B Type) (2)(Output) Video / Audio HDMI (1), Optical Output / Audio Out with OPS i5 system Touch type IR Available object size for touch Ø3 mm ↑ Response Time 60ms ↓ (Android) / 100ms ↓ (Windows) Accuracy 1.5mm Interface USB 2.0 Protection Glass Thickness 4T (Anti-Glare) make:-Samsung/LG/Panasonic (NS)
Supply, Installation, Testing, Commisioing of Interactive Digital Podium system with 16" interactive screen EMR technology, also available Gooseneck Microphone inbuilt Aluminium plated system Interface : USB, Pressure sensitive. Still image Resolution: XGA,SXGA,720P, 1080P, FRAME RATE 20 FRAMES/SEC. Image Mode: Normal/photo/Text/Slide/Film/Gray. Inputs- VGAx 2, HDMIX 1, Video x 2, Audiox 2 Outputs- VGA x 2, hHDMIX 1 VIDEOX1 AUDIO X1. Make:-AHA/Digital Podium Media (NS)
Two-Way 4" Coaxial Ceiling Loudspeaker with Frequency Range: 74 Hz - 20 kHz, Power Capacity (low-Z): 60 W Cont. ProgramMax. SPL: 102 dB @ 1m ave., 108 dB peak, Nominal Impedance: 8 ohms (in irect/bypass 8Ω setting), 70V/100V Transformer Taps capable,Make:-Bose/JBL/Audio tek. (NS)
Dual Channel Power Amplfier - 300W Analog Input Signal to Noise Ratio (ref. rated power, 100V, 20Hz - 20kHz) at 8 ohms) > 104dB Frequency Response (8Ω, 20 Hz - 20 kHz) +/-0.5dB Crosstalk (below rated power) 20 Hz to 1 kHz > 80dB also shall have GPIO/AUX Port – Recall presets, mute channels, monitor faults, power on/off the amplifier, and more through a combined GPIO/AUX Port. make:-Bose/JBL/Audio tek (NS)
Wireless Handheld Microphone System, Carrier frequency range 500.1 MHz – 864.9 MHz, Switching bandwidth 30.5 MHz (depending on local regulations), Audio bandwidth 35 to 20,000 Hz, Signal to Noise 120 dB-A, Up to 16 pre-programmed frequencies per group make:-Bose/AKGAudio tek (NS)
Wireless Presenter Set Microphone System, Carrier frequency range 500.1 MHz – 864.9 MHz, Switching bandwidth 30.5 MHz (depending on local regulations), Audio bandwidth 35 to 20,000 Hz, Signal to Noise 120 dB-A, Up to 16 pre-programmed frequencies per group make:-Bose/AKG/Audiotek (NS)
12x8 Digital Signal Processor with Digital link and AEC , 12 Analog Inputs (with 48v Phantom Power per Channel), 8 Analog Outputs, 12 Control Inputs and 6 Logic Outputs for GPIO Integration, Maximum Input Level: +20dBu with 0dB input gain,+8dBu with 12dB gain, Digital Input Impedance: 110 ohm (AES/EBU), 75 ohm (S/PDIF), Sample Rate: 48kHz or 96kHz, THD+N: <-140dB, Maximum Analog Output Level: +19dBu, Frequency Response: 20Hz-20KHz (+0.5dB/-1dB), THD: <0.01% 20Hz to 20KHz, +10dBu output, Dynamic Range: 108dB typical, 22Hz-22KHz unweighted Make:-Bose/BSS/AMX (NS)
VIJAYM PROJECTS PRIVATE LIMITED
S V POWER
SHREE PANCHMUKHI ASOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .