Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.7 L+₹54,864 (46.5%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical 14 P BLOCK YASHODA NAGAR KANPUR | KANPUR | KANPUR NAGAR | UTTAR PRADESH | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | General Engineering Works L2 | Shree Heramb Test Lab (OPC) Pvt. Ltd. L1 |
|---|---|---|---|---|---|
| 1.00ETD-II, Prayagraj | |||||
| 2.00 | Collection of transformer oil sample as per standard practice in proper & air light steel sampling bottle from bottom of T/F installed at following substation under ETD-II, Prayagraj. (Sample bottle will be provided by contractor on their own cost). | 27 | Jobs | 600 ₹16,200 | 470 ₹12,690 Lowest |
| 2.01400 KV Sub station Masauli-(3x200+1x20) MVA T/F | |||||
| 2.02400 KV Sub station Masauli-(1x125) MVAR Bus Reactor | |||||
| 2.03220 KV Sub station Rewa Road (2x200 + 1x160+3x40) MVA T/F | |||||
| 2.04220 KV Sub station Cantt (2x200+4x40) MVA T/F | |||||
| 2.05132 KV Sub station Minto Park (1x63+3x40) MVA T/F | |||||
| 2.06132 KV Sub station Teliarganj (2x63) MVA T/F | |||||
| 2.07132 KV Sub station GIS OPH (2x63) MVA T/F | |||||
| 2.08132 KV Sub station GIS Kareli (2x63) MVA T/F | |||||
Tender Value
₹1.3 L
EMD Value
₹1,600
Closing Date
24 Sept 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle-II, U.P. Power Transmission Corporation Ltd. 57- George Town, Prayagraj.
Transformer oil sample collection, testing at various sub stations, under ETD-II, ETD-III Prayagraj.
2025_UPTCL_1072931_1
31/ETC-II(P)/2025-2026
Open Tender
Electrical Works
Item Rate
60 days
ETD-II, III PRAYAGRAJ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer Electy. Trans. Div. Naini Alld.
₹1,600
2 Dec 2025
11 Sept 2025
25 Sept 2025
11 Sept 2025
24 Sept 2025
11 Sept 2025
Amount
ETD-II, Prayagraj
Collection of transformer oil sample as per standard practice in proper & air light steel sampling bottle from bottom of T/F installed at following substation under ETD-II, Prayagraj. (Sample bottle will be provided by contractor on their own cost).
400 KV Sub station Masauli-(3x200+1x20) MVA T/F
400 KV Sub station Masauli-(1x125) MVAR Bus Reactor
220 KV Sub station Rewa Road (2x200 + 1x160+3x40) MVA T/F
220 KV Sub station Cantt (2x200+4x40) MVA T/F
132 KV Sub station Minto Park (1x63+3x40) MVA T/F
132 KV Sub station Teliarganj (2x63) MVA T/F
132 KV Sub station GIS OPH (2x63) MVA T/F
132 KV Sub station GIS Kareli (2x63) MVA T/F
Following testing of above-mentioned sampled T/Fs oil required as per latest revelant Indian standard alongwith proper testing report of individual oil sample.
Breakdown voltage (IS : 6792)
Water content (PPM) (IS:13567)
Resistivity (as per IS:6103)
Dielectric Dissipation Factor (as per IS:6262)
Dissolved gas analysis (as per IEC:60567)
ETD-III, Prayagraj
Collection of transformer oil sample as per standard practice in proper & air light steel sampling bottle from bottom of T/F installed at following substation under ETD-III, Prayagraj. (Sample bottle will be provided by contractor on their own cost).
132 KV Sub station Naini Complex (4x40+1x20) MVA T/F
132 KV Sub station Meja (1x40+1x63) MVA T/F
132 KV Sub station Salayakhurd (2x40) MVA T/F
132 KV Sub station Karchanan (2x40+1x20) MVA T/F
132 KV Sub station Jari (2x40) MVA T/F
132 KV Sub station Koraon (2x20+1x40) MVA T/F
132 KV Sub station Shankargarh (2x40) MVA T/F
132 KV Sub station YPC (2x40) MVA T/F
Following testing of above-mentioned sampled T/Fs oil required as per latest revelant Indian standard alongwith proper testing report of individual oil sample.
Breakdown voltage (IS : 6792)
Water content (PPM) (IS:13567)
Resistivity (as per IS:6103)
Dielectric Dissipation Factor (as per IS:6262)
Dissolved gas analysis (as per IEC:60567)
Note:- Test report should be submitted in hard copy to concerned division in 02 copies.
General Engineering Works (BID ID -5557672)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .