Office of S E, Construction Circle, Jhans
Office of Superintending Engineer, Construction Circle, UPJN (Urban) Jhansi
Nagar Palika Parishad Mahoba Re-organization Water Supply Scheme
2025_UPJNM_1102695_1
1571/F-02/135 date 22-12-2025
Open Tender
Water Supply
Mahoba
Please refer Tender documents.
2 documents required · 2 mandatory
₹23,600
Executive Engineer, C D, UPJN (Urban) Hamirpur
₹1.5 Cr
Office of S E, Construction Circle, Jhansi
31 Dec 2025
31 Dec 2025
7 Feb 2026
31 Dec 2025
7 Feb 2026
31 Dec 2025
5 Jan 2026
CIVIL WORKS
WTP works
Survey, Investigation, Soil Testing, Planning, Design and Drawing construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevant latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be Vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of 9 MLD WTP on latest technology , Admin Building with Command Control Room, and fire fighting arrangements, first aid arrangements Cascading Aerator, Inlet chamber, alum dosing, pre-sedimentation Tank/Rapid Mix/Vertical Flow Clarifloculator/Rapid Gravity Filter with Back Wash Arrangement/Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area& Appurtenant Works of the above-mentioned capacity, automated through PLC with outputs to SCADA, walkway in between WTP components with railing, Guard Room, Chemical Store House, Gaseous Chlorination Plant, Development of WTP area with adequate plantation, Rainwater harvesting unit. Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Engineer/IS code. Collapsible MS steel doors and aluminum windows to be provided including of three-coat whitewashing, internal two coat apex ultima painting, external painting with apex ultima/equivalent paint, all steelwork must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data), including Water Testing Kits, Lab Building and essential lab equipment as mentioned in the related Items Including of supply of all materials, labor T&P etc required for proper completion of works as per direction of the Engineer. All works complete as per design and drawing approved by engineer incharge. contractor will have to provide four wheelers, two wheelers, with fuel & driver for supervision of work and computer/laptop with operator as mentioned in tender document. (Excluding E/M Works)
INTAKE WELL WORKS
Survey, Investigation, Soil Testing, Planning, Design and Drawing, construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevent latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of Intake Well (for Mahoba NPP & Kabrai NP) of minimum internal size of 10.00M Dia & Required Height with 3.5 M width foot bridge & required length as per site condition water inlet opening having minimum intake capacity to meetout the raw water required for WTP by different inlet points, construction of stair case, Pump house, Balcony, stair case post column beams etc. Such that to fix required nos. of VT Pump mention in item number 20.00, Power Control Panels, starters, intrumentation and SCADA & wireless telemetry (Voice & Data), internal and external electrification with adequate LED lightings including Excavation in soil i.e. Kankar mixed morrom/soft/hard rock and lean concrete of minimum grade of M-15 and R.C.C. in grade M-30 or above, in raft/ pile foundation, Intake R.C.C wall with supply of all type of steel bars of approved quality and cement OPC 53/43 grade of any make approved by the Employer as per design and drawings and binding the same including binding materials, diversion arrangement of flow during construction by making bundh across the dam supply gunny bags, sand, their filling suitable size of steel garder, with chain puli arrangement, dismantling and refixing etc. and also supply and fixing of collapsible gate, collapsible door, almunium window as per relevent specifications also including of three coat white washing, internal two coat snowcem painting, external painting with appex ultima or equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row of 20 mm dia G (Midium) pipe railing with 65X65X6 mm M.S. Angle iron posts. Supply and fixing of aniet opening of required capacity as per requirements including of supply of all materials, labour, T&P etc. required for proper completion of works as per direction of the Engineer. Cost of VT Pumps, panels, SCADA panel board, pipe manifolds etc. are not covered in this item.
Rising Main & By Pass arrangement
Supply of following sizes of DI pipes, class K-9 with rubber gasket, conforming to IS: 8329/2000 (reaffirmed year 2020) or its latest amendments, F.O.R. destination including insurance etc. complete
600 mm dia D.I. Class K-9
500 mm dia D.I. Class K-9
450 mm dia D.I. Class K-9
400 mm dia D.I. Class K-9
350 mm dia D.I. Class K-9
300 mm dia D.I. Class K-9
250 mm dia D.I. Class K-9
200 mm dia D.I. Class K-9
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Carting of the following sizes of D.I. Pipes (class K-9) and specials to the site of work, lowering them in to trenches and laying true to alignment and gradient including testing of pipeline (but excluding cost of trenching and cuttling of pipes etc. for making of lengths but including making joints)
600 mm dia D.I. Class K-9
500 mm dia D.I. Class K-9
450 mm dia D.I. Class K-9
400 mm dia D.I. Class K-9
350 mm dia D.I. Class K-9
300 mm dia D.I. Class K-9
250 mm dia D.I. Class K-9
200 mm dia D.I. Class K-9
Excavation for pipeline trenches including lift upto 1.5 m and lead upto 50 m and refilling, watering, ramming of excavated, earth in to the trenches and disposal of surplus earth upto 50 m from the center of the trenches
In ordinary soil (loam, clay, sand)
In soil mixed with moorum/ shingle/ kankar/rock
Depth:1.5m to 3.0m Dpeth (In soil mixed with moorum/ shingle/ kankar)
Supply & fixing of following sizes of C.I. Double flanged sluice valves as per IS 14846: 2000 (Reaffirmed Year: 2020) or its lastest amendment, class - 1 F.O.R. destination including insurance.
600 mm dia
500 mm dia
450 mm dia
400 mm dia
350 mm dia
300 mm dia
250 mm dia
200 mm dia
Supply & fixingof C.I. Air valve
Supply and fixing of 100 mm dia. size of C.I. Double flanged scour valve as per IS: 780 class 1 F.O.R. destination including all taxes and insurance.
Supply of all materials, labour, T&P and construction of following chambers as per type design including supply and materials, labour and T&P, testing etc. complete.
Masonry Type
Air Valve chamber
Scour Valve chamber
Dismantling of following type of road surfaces for lying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Bituminous Road
C.C. Road
Interlocking Road
Reinstatement of following type of road surfaces for lying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Bituminous Road
C.C. Road
Interlocking Road
Supply of all materials, labour, and T & P etc. and construct R.C.C. thrust blocks.
R.C.C. work in 1:1.5:3
Mild steel work
Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions.
700mm dia pipe, 10mm Pipe Wall Thickness
600mm dia pipe, 10mm Pipe Wall Thickness
Distribution System
Supply of the following D.I. pipes (K-7) conforming to 1.8 -8329/2000 (reaffirmed year 2020) or its latest amendment(s). Including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of one Rubber Gasket per pipe length & inclusive of Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc.
450 mm dia D.I. Class K-7
400 mm dia D.I. Class K-7
350 mm dia D.I. Class K-7
300 mm dia D.I. Class K-7
250 mm dia D.I. Class K-7
200 mm dia D.I. Class K-7
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Supply of the following HDPE Pipes as per I.S. 4984/2016 or its latest amendment inclusive of 3rd party inspection charges, packing and forwarding charges, trasnit insurance charges, road transportation charges etc. F.O.R. destination etc. complete.
HDPE Pipe PN 6: class PE 100
110 mm dia
140 mm dia
160 mm dia
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches.
In ordinary soil (loam, clay, sand)
In soil mixed with moorum/ shingle/ kankar/rock
Carting of following pipes, specials and fittings to site of work, lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line including cutting of pipe for making up lengths as required for proper completion of work
HDPE Pipe PN 6: class PE 100
110 mm dia
140 mm dia
160 mm dia
DI Pipe K-7
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
450 mm dia
Supply & fixing of following sizes of C.I. Double flanged sluice valves as per IS 14846: 2000 (Reaffirmed Year: 2020) or its lastest amendment, class - 1 F.O.R. destination including insurance.
Sluice Valves
450 mm dia
350 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
100 mm dia
Scour Valves
80 mm dia
Air Valves
20 mm dia
Fire Hydrants
80 mm dia
Supply construction of following chambers as per type design including supply and materials labour, T&P etc. complete.
Surface Box Type
Masonry Type
Air Valves
Fire Hydrants
Dismantling of following type of surface including sorting out and staking of serviceable materials and disposal of unserviceable material up to a distance of 50m.
Bituminous Road
CC Road
Inter locking Road
Reinstatment of following type of road including supply of all material, labour etc complete. All works complete as per design and drawing approved by engineer incharge
Bituminous Road
CC Road
Inter locking Road
Crossing of Culvert upto 3.5M width for laying pipe line including supply and materials labour, T&P etc. complete.
Crossing of Drain from 0.5 to 1.50M Width for laying pipe line includingsupply and materials labour, T&P etc. complete.
Crossing of Drain from 1.50 to 3.0M Width for laying pipe line includingsupply and materials labour, T&P etc. complete.
Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions.
150mm dia pipe, 6mm Pipe Wall Thickness
200mm dia pipe, 6mm Pipe Wall Thickness
250mm dia pipe, 6mm Pipe Wall Thickness
300mm dia pipe, 6mm Pipe Wall Thickness
House connection on New Pipeline
Provision of House connection including Supply of all materials, labours T&P etc required for proper completion of work. (as following)
Making House Connection with distribution main including dismantling of road, supply, carting of specials, Lowering them into trances, fixing them in proper alignment and jointing including bailing out to water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work. All works complete as per design and drawing approved by engineer incharge
In Bituminous Road
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
In C. C. Roads
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
In C. C. Interlocking tiles Roads
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
In Earthen Roads
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
Converting existing house connections to new distribution pipelines of various sizes, including supply and carting of specials, trenching, pipe laying and jointing (using existing serviceable and new materials such as 20mm HDPE, 20mm GI, saddles, couplers, elbows, bib cocks, etc.), alignment, dewatering, excavation, barricading, road dismantling and road reinstatement. Includes all labor, T&P, materials, and incidentals for completion in all road types.
In Bituminous Road
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
In C. C. Roads
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
In C. C. Interlocking tiles Roads
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
In Earthen Roads
For 90 mm to 110 mm dia
For 125 mm to 160 mm dia
RCC OHT
Survey & Design, Supply of all materials, labour, T&P etc, and construct an RCC over head tank of following capacity with RCC staircase and 1m wide balcony, G.I. Pipe and angle iron posts around the balcony and at the dome periphery, M.S. ladder from the balcony to the top of tank and inside the tank, supply and fixing M.H. cover with locking device, ventilator; lightening conductor, water level indicator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the tank, escape channel of 20m length, box type enclosure at the entrance of the staircase having locking arrangements, two coats of snowcem paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/Fpipes and valves etc. all complete including site clearance and other unforeseen items for following zones.
650 KL with 24 m Staging
1200 KL with 24 m Staging
1300 KL with 24 m Staging
Cost for testing of bearing capacity of soil for various sites for proposed water works.
Renovation of existing 1700 KL OHT (Repair, plaster, painting, water level, apron etc required for proper completion of work.)
RCC GSLR (On Hill)
Survey & Design, Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump. M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, lightening conductor, water level indicator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/Fpipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones.
Cost for testing of bearing capacity of soil for various sites for proposed water works.
Renovation of existing 2050 KL CWR (Repair, plaster, paiting, water level,apron etc required for proper completion of work.)
REPAIRING OF 15.55 MLD EXISTING WTP
For Repair of WTP, Admin Building with Command Control Room, and fire fighting arrangements, first aid arrangements Cascading Aerator, Inlet chamber, alum dosing, Rapid Mix/Vertical Flow Clariflocculator/Rapid Gravity Filter with Back Wash Arrangement/Proper Sludge Disposal and Backwash water disposal artangements to nearest drain/low laying area& Appurtenant Works of the above-mentioned capacity, automated through PLC with outputs to SCADA, walkway in between WTP components with railing, Chemical Store House, Gaseous Chlorination Plant, Development of WTP area with adequate plantation, Rainwater harvesting unit. valves (especially actuated valves), pumps, filters, piping, chemical feed systems, screens, sedimentation tanks, chlorination equipment, blower equipment and any electrical components that may be malfunctioning, often requiring replacement of parts due to wear and tear or corrosion over time. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @ 0.05kg/running metre and while the suface is tacky filled the groove up to surface with crystalline mortar 18 mm cement plaster in two coats under layer 12 mm thickcement plaster 1:5 finished with a top layer 6mm thick cementplaster 1:6 Providing and injecting approved grout on RCC structures in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures Repair of M.S. ladder and hand rails Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. Finishing of all Wall/concrete surface in two coat premium acrylic smooth exterior paint with silicon addive, with one coat of exterior primer over smooth base of white cement, cement based wall putty and steel pipe works with three coats of approved cement paint and anticorrosive paints
Repair Cost of WTP (15.55 MLD) - Civil Works (15.55 MLD x 70 Lakh/MLD x 60% x 5%)
Construction of new Clariflocculator and Flash Mixtur of capacity of 15.55 MLD at existing WTP site i/c bypass arrangement channel/pipes etc all complete (Civil Cost of 15.55 MLD Clariflocculator & Flash Mixture at existing WTP = 15.55 x 70 x 60% x 15%)
Construction of 3.0mx3.0mx2.0m masonry type VFD Pump chamber including plaster supply of all materials, labours, T&P etc. required for proper completion of work. ( zone-2,3,4,7)
STAFF QUARTER
Construction of Staff Quarter including all materials, labour, T&P Complete as per type design & Unit Estimate.
BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD
Construction of Boundary wall around water works compound including all materials, labour, T&P Complete as per type design & Unit Estimate.
Repairing of existing boundary wall as per the unit estimate for this zone including all materials, labour, T&P Complete as per type design & Unit Estimate.
Extra Ist class brick work in 1:6 cement and coarse sand mortar in foundation and plinth due to low land area including supply of all materials, labour, T&P etc required for proper compition of work
Fixing of 3.6m wide MS gate with 1.2m wide wicket gate Including fabrication and supply of steel and construction of boundary pillars etc. all complete.
Supply and laying of 80mm thick Cement interlocking tiles for approach road including preparation of 100mm thick subgrade with lean concrete 1:4:8 including supply of all material, labour and T&P etc complete for proper completion of the work.
Earth filling including all materials, labour, T&P Complete as per Unit Estimate.
Provision for inside square drain including supply of all materials labour and T & P etc. complete
Construction of Rain Water Harvesting Chamber 5.50m x3.50x 1.80m with 02 Nos 110mm Dia, 20 mtr Deep Borewell in Water Works Campus including all materials, labour, T&P Complete as per type design & Unit Estimate.
Landscaping, plantation work in water works campus including all materials, labour, T&P Complete.
E/M WORKS
INTAKE WELL AT KABRAI DAM FOR 9.0 MLD WTP
PUMPING PLANTS:
Supply, installation, testing and commissioning of Vertical Turbine Raw water pump (oil cooled)alongwith all necessary arrangements to lift 3600 LPM discharge at 68 m head complete with 24 m column assembly , 100 HP TEFC motor B class insulation with reversible ratchet, chuck nut and top shaft locking arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. (Synchronous Speed 1450 RPM)
3600 LPM, 100 HP, 68 m Head, 1450 RPM ( Head , discharge an hp may increase as per site condition)
SITC of 75 Kw or more as per site condition with best enginnering manner digital Soft Starter with RS485 port - 400 V class for INTAKE Motors
Supply and laying of 3 core 50 Sq.mm. or more as per site condition with best enginnering mannerArmoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs with all material labour ,T&P
A) MAIN PIPING- SITC of CIDF/DIDF 200 mm Main piping required for delivery side, 300 mm common Header upto 1 m outside with Nos 300x200x300 mm size Tee and 1 Nos 300x200x300 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer . complete in all respect as per site conditions . ( size of delivery and common header may increase as per site condition)
Nut , bolt & rubber packing
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 200 mm size (03 nos for pumping plant 01 no for bypass ) ( Size may increase as per site condition with best engineering manner)
ii) 300 mm size ( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 200 mm size ( Size may increase as per site condition with best engineering manner)
ii) 300 mm size ( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 300 mm ( Size may increase as per site condition with best engineering manner)
ELECTRICAL ITEMS:
SITC of of 200 kvar APFC panel suitable for above LT panel for MCWR load with all necessary metering and protective devices complete in all respect.
Supply and laying of 3.5 core 95 Sq.mm. Armoured Aluminum Conductor Cable From 02 nos of Transformer to LT panel with lugs etc. in 04 runs
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 500 Amp. Or more as per site requirement
SITC of dust and vermin proof LT Pannel with electrically and mechanically interlocked 02 nos. incoming of 630 Amp ACB for 02 nos transformer and 3Nos. (2w+1s) , 250 Amp , 2 Nos 100 amp and 2 nos 63 amp outgoing MCCB Mirco processor based complete suitable to operate on 415±6 % volt , 3 phase , 50 Hz, AC supply with CT'S, PT, AVF meter, PF meter, Relays , protective device and have sufficient space for soft starters of pumping plant complete in all respect. individual motors
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified Radar type Level Transmiter for Intake well.
SITC of CE/UL Certified Surge protector for control panel
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works and all material, separate double earthing for each equipment shall be carried out.
SITC of 5Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs with double grider including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
Tools
10 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) and ventillation (including bird guard /exhaust fan if required) of pumping station including concealed conduit or duct wiring with any electrical item required for proper completion of work
Lightining of INTAKEWELL campus
S/F of Ms Tubular poles SP36 9.5 m height with junction box
S/f of @x40 w LED Green Grace light lumen 120w colour warm white as per required illumination level with all required acessories for proper functioning
S/f of unarmoud aluminium cable 6sq mm 2 core for connection of above light through junction box
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all equipments and pumping plants etc complete in all respect.
New 9.00 MLD WTP AT KENDRIYA VIDYALAY
EPC contract for a 9.0 MLD Water Treatment Plant at Kabrai Dam, including detailed design and drawings; SITC of all electro-mechanical works with latest SCADA-based automation; integration with approved civil structures; all materials, labour, and T&P; wetted-parts design subject to Engineer-in-Charge approval; adequate standby units and spares; and complete gaseous chlorination system (1W + 1S) for pre- and post-treatment with chlorine analyzers, leak detection and absorption system with full safety tools, complete in all respects.
CCWR AT WTP (KABRAI DAM)
PUMPING PLANTS: CCWR
SITC of Vertical Turbine water lubricated Clear Water Pump with 4.5 mt column assembly along withVHS,TEFC,IE-3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
3600 LPM, 120 HP, 83 m Head, 1450 RPM ( Head , discharge and hp may increase as per site condition)
SITC of 90 Kw digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 120Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in single runs
A) MAIN PIPING- Supply of CIDF/DIDF 200 mm Main piping required for delivery side, 350 mm common Header upto 1 m outside with 3 Nos 350x200x350 mm size Tee and 1 Nos 350x200x350 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .( size of common header and delivery pipe may increase as per site condition)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 200 mm size (03 nos for pumping plant 01 no for bypass )( Size may increase as per site condition with best engineering manner)
ii) 350 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 200 mm size( Size may increase as per site condition with best engineering manner)
ii) 350 mm size ( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 350 mm for CWR outlet( Size may increase as per site condition with best engineering manner)
SITC of Flow Control Valve
200 mm for zone 1( Size may increase as per site condition with best engineering manner)
300 mm for zone 2&3( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CCWR
Electrical Item
SITC of 150 kvar APFC panel suitable for above LT panel for CCWR load with all necessary metering and protective devices complete in all respect.
Supply and laying of 3.5 core 240 Sq.mm. Armoured Aluminum Conductor Cable from Transformer to Lt Panel with lugs etc. in 03 runs
Supply and laying of 3.5 core 120 Sq.mm. Armoured Aluminum Conductor Cable from LT Panel to WTP Panel with lugs etc. in 02 runs
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 500 Amp. Or more as per site requirement
SITC of dust and vermin proof Lt Panel consisting of 2 Nos incoming Mirco processor based ACB of 630 Amp( 02 for transformer ) , 05 Nos. outgoing Mirco processor based MCCB of 300 Amp (03 nos for pumping plant and 02 nos for wtp) and 2 nos of 63 Amp MCCB Mirco processor and 02 nos 100 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays and protective device complete in all respect. etc. wiring, CT'S, PT, AVF meter, PF meter, Relays and protective device , Ampere meter, Voltmeter, protective device and have sufficient space for soft starters of pumping plant etc complete in all respect.
SITC of CE/UL Certified three phase Surge protector for control panel
SITC of CE/UL Certified Radar type Level Transmiter for CCWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works and all material, separate double earthing for each equipment shall be carried out.
SITC of 5Ton capacity Electricaly operated overhead travelling (EOT) crane suitable for span up to 10 mtrs and travelling length upto 10 mtrs with clear lift up to 12 mtrs,double grider including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
EXISTING INTAKE WELL AT shri nagar FOR 15.55 MLD WTP
PUMPING PLANTS:
Supply, installation, testing and commissioning of Vertical Turbine Raw water pump (oil cooled) alongwith all necessary arrangements to lift 3150 LPM discharge at 68 m head complete with 18 m column assembly , 75 HP TEFC motor B class insulation with reversible ratchet, chuck nut and top shaft locking arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. (Synchronous Speed 1450 RPM)
3150 LPM, 75 HP, 66 m Head, 1450 RPM (Head ,discharge & hp may increase as per site condition)
SITC of 75 Kw or more as per site condition with best engineering manner digital Soft Starter with RS485 port - 400 V class for INTAKE Motors
Supply and laying of 3 core 35 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs with all material labour T&P
A) MAIN PIPING- SITC of CIDF/DIDF 200 mm Main piping required for delivery side, 450 mm common Header upto 1 m outside with 6 Nos 450x200x450 mm size Tee and 1 Nos 450x200x450 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer . complete in all respect as per site conditions . ( size of delivery and common header may increase as per site condition)
Nut , bolt & rubber packing
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 200 mm size ( Size may increase as per site condition with best engineering manner)
ii) 450 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 200 mm size ( Size may increase as per site condition with best engineering manner)
ii) 450 mm size ( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 450 mm ( Size may increase as per site condition with best engineering manner)
ELECTRICAL ITEMS:
SITC of 200 kvar APFC panel suitable for above LT panel for MCWR load with all necessary metering and protective devices complete in all respect.
Supply and laying of 3.5 core 300 Sq.mm. Armoured Aluminum Conductor Cable From 02 nos of Transformer to LT panel with lugs etc. in 02 runs
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 630 Amp. Or more as per site requirement
SITC of dust and vermin proof LT Pannel with electrically and mechanically interlocked 02 nos. incoming of 630 Amp ACB for 02 nos transformer and 6Nos. (4w+2s) , 200 Amp , 2 Nos 63 amp and 2 nos 32 amp outgoing MCCB Mirco processor based complete suitable to operate on 415±6 % volt , 3 phase , 50 Hz, AC supply with CT'S, PT, AVF meter, PF meter, Relays , protective device and have sufficient space for soft starters of pumping plant etc complete in all respect.
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified Radar type Level Transmiter for Intake well.
SITC of CE/UL Certified three phase Surge protector for control panel
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works and all material, separate double earthing for each equipment shall be carried out.
SITC of 5Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs double grider including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
Tools
10 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) and ventillation (including bird guard /exhaust fan if required) of pumping station including concealed conduit or duct wiring with any electrical item required for proper completion of work
Lightining of INTAKEWELL campus
S/F of Ms Tubular poles SP36 9.5 m height with junction box
S/f of @x40 w LED Green Grace light lumen 120w colour warm white as per required illumination level with all required acessories for proper functioning
S/f of unarmoud aluminium cable 6sq mm 2 core for connection of above light through junction box
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all E/M equipments and pumping plants etc complete in all respect work also includes dismentalling ,loading ,unloading & carting upto store of local body with their full satisfiction and handover all material to local body of earlier installed working/non working E/m equipment without effecting running water supply with all material ,labour and t&p
15.55 MLD WTP at shrinagar
Replacement of all E/M equipment earlier installed at existing WTP with latest techlonogy SCADA bassed with all material labour andT&P cost includes wetted design as per engineer incharge with latest SCADA Based techlonology with proper standby and spare equipments according to work place provided by nodal divission with proper arrangement of (1w+1s) pre & post gaseous chlorination system with gaseous chlorine detection & absorption system coolling tower type and sufficient quantity working and 100% spare safety tools for labour and staff Also dismentalling ,loading ,unloading & carting upto store of local body with their full satisfiction and handover all material to local body of earlier installed working/non working E/m equipment without effecting running water supply with all material ,labour and t&p
Existing CCWR at WTP ( Shri nagar)
PUMPING PLANTS: CCWR
SITC of Vertical Turbine water lubricated Clear Water Pump with 4.5 mt column assembly along withVHS,TEFC,IE-3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
6200 LPM, 75 HP, 34 m Head, 1450 RPM ( Head , discharge & Hp may increase as per site condition)
SITC of 75 Kw or more as per site condition with best engineering manner digital Soft Starter with RS485 port - 400 V class for CCWR Motors
Supply and laying of 3 core 35 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in single runs with all material,labour,T&P
A) MAIN PIPING- Supply of CIDF/DIDF 300 mm Main piping required for delivery side, 450 mm common Header upto 1 m outside with 3 Nos 450x300x450 mm size Tee and 1 Nos 450x300x450 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions . ( size of common header & delivery may increase as per site condition)
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 300 mm size( Size may increase as per site condition with best engineering manner)
ii) 450 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 300 mm size( Size may increase as per site condition with best engineering manner)
ii) 450 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 450 mm for CWR outlet( Size may increase as per site condition with best engineering manner)
SITC of Flow Control Valve
200 mm for zone 5( Size may increase as per site condition with best engineering manner)
250 mm for Zone 6,7&8( Size may increase as per site condition with best engineering manner)
300 mm for zone 4( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CWR
Electrical Item
SITC of 100 kvar APFC panel suitable for above LT panel for CWR load with all necessary metering and protective devices complete in all respect.
Supply and laying of 3.5 core 300 Sq.mm. Armoured Aluminum Conductor Cable from Transformer to Lt Panel with lugs etc. in 02 runs
Supply and laying of 3.5 core 120 Sq.mm. Armoured Aluminum Conductor Cable from LT Panel to WTP Panel with lugs etc. in 02 runs
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 630 Amp.or more as per site condition
SITC of dust and vermin proof Lt Panel consisting of 2 Nos incoming Mirco processor based ACB of 630 Amp( 02 for transformer ) , 03 Nos. outgoing Mirco processor based MCCB of 200 Amp (06 nos for pumping plant) , 02 nos 320 amp MCCB for wtp , 2 nos of 63 Amp and 02 nos 32 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays and protective device complete in all respect. etc. wiring, CT'S, PT, AVF meter, PF meter, Relays and protective device , Ampere meter, Voltmeter , protective device and have sufficient space for soft starters of pumping plantetc complete in all respect.
SITC of CE/UL Certified three phase Surge protector for control panel
SITC of CE/UL Certified Radar type Level Transmiter for CWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works and all material, separate double earthing for each equipment shall be carried out.
SITC of 5Ton capacity hand operated overhead travelling (HOT) crane suitable for span up to 6 mtrs and travelling length upto 10 mtrs with clear lift up to 6 mtrs Double grider including gear type chain pulley block and geared travelling trolley complete with all accessories including girder.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner . fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all E/M equipments and pumping plants etc complete in all respect work also includes dismentalling ,loading ,unloading & carting upto store of local body with their full satisfiction and handover all material to local body of earlier installed working/non working E/m equipment without effecting running water supply with all material ,labour and t&p
SUB STATION OF INTAKE (315 KVA)(Kabrai Dam)
SITC of 2mm thick MS Sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with all accessories and protective devices suitable for 315 KVA 2 Nos.11/0.4 KV transformers.
Supply and laying of 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer. In 02 run with all material labour T&P
Supply Installation Testing and Commissioning of 315 KVA 11/0.433 KV 50 Hz Copper wound oil cooled outdoor type Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (coper material) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
SUB STATION OF WTP + CCWR of Kabrai Dam (400 KVA)
SITC of 2mm thick MS Sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with all accessories and protective devices suitable for 400 KVA OR more as per site requirement 2 Nos.11/0.4 KV transformers.
Supply and laying of 35 Sq.mm size OR more as per site requirement XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer.
Supply Installation Testing and Commissioning of 400 KVA OR more as per site requirements 11/0.433 KV 50 Hz Copper wound oil cooled outdoor type Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (coper material) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
SUB STATION OF intake Shrinagar (400 KVA)
SITC of 2mm thick MS Sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with all accessories and protective devices suitable for 400 KVA 2 Nos.11/0.4 KV transformers.
Supply and Laying of 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer.
Supply Installation Testing and Commissioning of 400 KVA 11/0.433 KV 50 Hz Copper wound oil cooled outdoor type Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (coper material) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.work includes dismentalling ,loading ,unloading & carting upto store of local body with their full satisfiction and handover all material to local body of earlier installed working/non working E/m equipment without effecting running water supply with all material ,labour and t&p
Supply and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
SUB STATION OF WTP+CCWR SHRinagar(315 KVA)
SITC of 2mm thick MS Sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with all accessories and protective devices suitable for 315KVA OR more as per site requirement 02 Nos.11/0.4 KV transformers.
Supply and laying of 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer.
Supply Installation Testing and Commissioning of 315 KVA OR more as per site requirement 11/0.433 KV 50 Hz Copper wound oil cooled outdoor type Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (coper material) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.work also includes dismentalling ,loading ,unloading & carting upto store of local body with their full satisfiction and handover all material to local body of earlier installed working/non working E/m equipment without effecting running water supply with all material ,labour and t&p
Supply and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
Boster pump
Booster pumps
SITC of Booster pump set for Clear water with sp gravity 1.0 ,having discharge 422 cu.m /hr , 20 m head,45 Kw 1500 rpm 415 v 3 phase AC with SCADA compactible VFD control pannel having in built controller suction and delivery piping upto pump base plate along with valves and pressure transmitter for Zone 2 ( 01 set = 02 nos )
SITC of Booster pump set for Clear water with sp gravity 1.0 having discharge 162 cu.m /hr , 17 m head,18.5 Kw 1500 rpm 415 v 3 phase AC with SCADA compactible VFD control pannel having in built controller suction and delivery piping upto pump base platealong with valves and pressure transmitter for Zone 7,DMA-2 ( 01 set = 02 nos )
SITC of Booster pump set for Clear water with sp gravity 1.0 having discharge 42 cu.m /hr , 5 m head,3 Kw 1500 rpm 415 v 3 phase AC with SCADA compactibleVFD control pannel having in built controller suction and delivery piping upto pump base plate along with valves and pressure transmitter for Zone 3,DMA -1 ( 01 set = 02 nos )
SITC of Booster pump set for Clear water with sp gravity 1.0 having discharge 10 cu.m /hr , 5 m head,1.5 Kw 1500 rpm 415 v 3 phase AC with SCADA compactible VFD control pannel having in built controller suction and delivery piping upto pump base plate along with valves and pressure transmitter for Zone 3,DMA -2 ( 01 set = 02 nos )
SITC of Auto phase reversal switch
160 amp for zone2
100 amp for zone 7 ,zone3 DMA1 &dma2
SITC of Surge protector three phase for all booster pump
Electrical & Instrumentation Works at DMA
SITC of Motor operated actuator with sluice valve at OHT outlet :-
250 mm for Zone 1&5
350 mm for zone 6,7&8
400 mm for Zone 2,3&4
SITC of flow control valve for flow controling, pressure monitoring and web based with cable PLC etc Complete at DMA inlet.
150 mm for Z-3,DMA-1
200 mm for Z-1,DMA-2,Z-2,DMA-3,-1Z-8,DMA 1
250 mm for Z-1,DMA-1 ,Z-2,DMA-2,Z-3,DMA-2,3,4,Z-4,DMA-1,2,3,Z-5,DMA-1,Z-6,DMA-2,Z-7,DMA-2,&Z-8,DMA-3
300 mm for Z-2,DMA-1,Z-6,DMA-1,Z-7,DMA-1
350 mm for Z-8,DMA-2
Dismental joint
150 mm for Z-3,DMA-1
200 mm for Z-1,DMA-2,Z-2,DMA-3,Z-8,DMA 1
250 mm for Z-1,DMA-1 ,Z-2,DMA-2,Z-3,DMA-2,3,4,Z-4,DMA-1,2,3,Z-5,DMA-1,Z-6,DMA-2,Z-7,DMA-2,&Z-8,DMA-3
300 mm for Z-2,DMA-1,Z-6,DMA-1,Z-7,DMA-1
350 mm for Z-8,DMA-2
SITC of CE/UL Certified level transmitter for OHT :- SITC of Radar type level transmitter with CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Range- 0 to …30... mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68
SITC of CE/UL Certified Electromagnetic flow meter at DMA inlet :-
150 mm for Z-3,DMA-1
200 mm for Z-1,DMA-2,Z-2,DMA-3 Z-8 DMA -1
250 mm for Z-1,DMA-1 ,Z-2,DMA-2,Z-3,DMA-2,3,4,Z-4,DMA-1,2,3,Z-5,DMA-1,Z-6,DMA-2,Z-7,DMA-2,&Z-8,DMA-3
300 mm for Z-2,DMA-1,Z-6,DMA-1,Z-7,DMA-1
350 mm for Z-8,DMA-2
SITC of CE/UL Certified Pressure transmitter at DMA inlet :- SITC of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 68
SITC of Dosing System at DMA inlet :-SITC of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible )
SITC of Residual chlorine analyser / meter at DMA inlet :-Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator and gives 2 outputs one to Local display & other to PLC including Mounting arrangement. Overall Range : 0 - 8 mg/l (ppm) Accuracy : 2% of full scale Supply Voltage : 230 V ac+B7 Output : 4-20 mA Membrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required.
Installation, cabling of OHT including all equipments with all power and control cable,testing and commissioning complete in all respect.
Automation of Intake Well ( kabrai),intake (Shrinagar),CWR (kabrai), CWR (Shrinagar) & 04 nos Booster pumps
For Intake Well
SITC of CE & UL Certified PLC/RTU with redundantCPU & Power supplyin IP 54 enclose suitable to Communicate with GSM based modem unit with redundant CPU & Power supply with annlog & digital parameter & featuers as specified, for each Intakewell to store and transmit data on GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified in tender technical specifications.
G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification .
SITC of Intelligent energy meters
SITC of Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps.
SITC of CE/ UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters.
Cabling
Complete Cabling for Intake well including all power & control cable of all equipments .
SITC of Security Survelliance IP Camera with recorder
Master Control Station (MCS)
SCADA DISPLAY
SITC of CE/UL & BIS Certified industrial grade LED MONITOR with latest configrutation as per specification
Desktop/PC with i7 processor for as per specification mentioned in technical bid documents.
SITC of CE/UL Certified 5KVA UPS with batteries as per specification mentioned in technical bid document.
Full development version of required TAGS SCADA Software with coustomisation of software for MCS as per requirement
SITC of CE/UL Certified master control room PLC with redundant CPU & power supply at MCS in IP54 - enclouser as spec mentioned in technical bid documents.
SITC of CE/UL Certified Field gateway agent for transfering data from MCS to Central control room.
SITC of GSM based wireless /Broadband/Equipment communication system for PLC capable to transfer & received data & gather dat from remote sites to control station,All accessories included signal enhancer antenna along with running expenses till DLP.
SITC of CE/UL Certified Firewall for network protection.
SURGE PROTECTOR FOR ETHERNET Communication protection.
SITC of CE/UL certified industrial grade Ethernet Switch.
Mobile App Facility system architecture(Industries internet based & viewed through mobile apps for increased local & Remote Visibility).
Canon/HP or equivalent Laser Printer 1018 or equivement.
Security Surveillance IP camera with recorder (optional)
Installation, Commissioning & testing of all SCADA related equipment including required furniture AC labour & materialetc.
Trial run for 3 month period of MCS
Trial run WTP &INTAKE including gaseous chlorine, PAC and 02 no. supervisior, 6 no. SCADA Operator, 2 no. electrician 02 fitter/helper and 04 nos watchman each month for 03 months for both 9.5 mld wtp+ccwr ,intake at kabrai and 15.5 mld wtp+ccwr,intake at shrinagar for 03 months
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.94 MB
Tenderdocmahoba.pdf
Tender Documents • 13.47 MB
BOQ_2033240.xls
BOQ • 0.85 MB
Download all tender documents and submit your bid