Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.5 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹19.7 L+₹22,840 (1.17%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L-2 | Rejected-Finance Being other than lowest. | |
| 3 | L-3₹21.1 L+₹1.6 L (8.37%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest. | |
| 4 | L-4₹21.2 L+₹1.7 L (8.89%)Rejected-Finance 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | L-4 | Rejected-Finance Being other than lowest. | |
| 5 | L-5₹23.8 L+₹4.3 L (22.1%)Rejected-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L-5 | Rejected-Finance Being other than lowest. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Feb 2021, 6:00 pmClosed
GEAFADMAREAAGRA
GEAFADMAREAAGRA
REPAIR MAINT OF INTERNAL WIRING LIGHT FITTINGS FIXTURES MCBS DBS AND OTHER CONNECTED WORKS IN 4 AREA UNDER GE AF ADM AREA AGRA
2021_MES_413724_1
8000-1851/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GEAFADMAREAAGRA
Class E Cat b (i) and for un enlisted firms docus as per NIT
8 documents required · 8 mandatory
₹500
GEAFADMAREAAGRA
₹50,000
Yes
20 Feb 2021
18 Jan 2021
6 Feb 2021
18 Jan 2021
4 Feb 2021
23 Jan 2021
Amount
Taking down old unserviceable copper/ aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/ casings & caping complete, including fixture and fittings such as switches, ceiling roses, pendents holder, regulators, sockets and defective main switch/ DB/ MCB/ Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
M&L for point wiring for light/ fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise press steel sunk box having thickness not less than 2 mm with 3mm thick ISI marked bakalite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in , cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified . Note: Colour coding shall be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)(Make of 1.5 sqmm copper wire: Finolex/ Grandlay/ Polycab
All as per ser item No 2.00 here-in-before but for call bell point.
All as per ser item No 2.00 here-in-before but for 5 pin 5 amps socket outlet independent board.
All as per ser item No 2.00 here-in-before but for 3 pin 5 amps socket outlet on the same board with other switch.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed. Note: (a) colour coding shall be maintained .(Ph-Red, N-Black,Earth- Green)(Make of 2.5 sqmm copper wire: Finolex/ Grandlay/ Polycab)
M&L for point wiring for light / fan controlled by one switch with 1.50 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable in existing PVC concealed conduit terminated in new anodise pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistanded copper conductor FRLS as earth continuity conductor connected to common earth dolly in, cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified . Note: Colour coding shall be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green). Make of 1.5 sqmm copper wire: Finolex/ Grandlay/ Polycab
All as per ser item No 7.00 here-in-before but for call bell point.
All as per ser item No 7.00 here-in-before but for 5 pin 5 amps socket outlet independent board.
All as per ser item No 7.00 here-in-before but for 3 pin 5 amps socket outlet on the same board with other switch.
M&L for point wiring with 2.50 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable in existing PVC concealed conduit terminated in new anodise pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 2.5 sqmm single core PVC insulated unsheathed multistanded copper conductor FRLS as earth continuity conductor connected to common earth dolly in, cutting chiseling for concealed piping ,including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding shall be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green).Make of 2.5 sqmm copper wire: Finolex/ Grandlay/ Polycab
S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. Make : Havells Reo/Legrand/ SSK.
S & F bell push flush type 5 amps SP 240 volts complete all as specified and directed. Make : Havells Reo/Legrand/ SSK.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. Make : Havells Reo/Legrand/ SSK.
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. Make : Havells Reo/Legrand/ SSK.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. Make : Havells Reo/Legrand/ SSK.
S & F bell AC , 230 VOLTS, single pole complete all as specified and directed. Make : Havells Reo/Legrand/ SSK.
S & F lamp holder/ batton holder/ angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. Make : Havells Reo/Cona/ SSK.
S & F ceiling rose 65 x 50mm three terminals complete all as specified and directed. Make : Havells Reo/Cona/ SSK.
S & F ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed. Make : Havells Reo/Legrand/ SSK.
S & F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor shall not be less than 0.95) complete all as specified and directed. Note:- (i) Contractor shall submitt LM 79 & LM 80 test report from OEM owned NABLE accredited laboratory . (ii) Contractor shall conduct the inspection of company rep. for material genuinety at site at no extra cost. Make:- Philips Cat Ref BN021C LED20S PSU CW GR S2/ Havells Cat Ref LUMILINEPLUSBS20WLED/ WIPRO Cat Ref LL20-281-XXX-65ALI
S&F in replacement of existing U/S tube rod with LED tube rod 20 watts (4feet), 230V, 50 Hz ultra bright intergrated polycarbonate body LED tube light with high efficacy suitable for installation in existing tube light fitting complete all as specified and directed. Note:- (i) Contractor shall submitt LM 79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall conduct the inspection of company rep. for material genuinety at site at no extra cost. Make:- Havells Cat Ref TITANIANEO1213T8SSTL20WLED865SPC/ Wipro Cat Ref. LL13-181-65SESL or equivalent in Philips.
S&F in replacement of old U/S tube light fitting with energy saving decorative batten type 9/10 watt energy efficient tube light fitting (2 Feet) highly durable surfacce mounted LED baten constructed of fire retardent engineering grade extruded plastic and decorative end caps with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note :- (i) Contractor shall submitt LM 79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall conduct the inspection of company rep. for material genuinety at site at no extra cost. Make:- Philips Cat Ref BN021LED10S-6500 PSU GR S1/ Havells Cat Ref ENDURALINEARNEOBS10WLED865SPCWH/ Wipro Cat Ref LL20-111-XXX-65NE3.
S&F in replacement enery saving new generation LED 10/6 Watts, 6000K, IP-65 bulk head luminarie with opal diffuser complete including connecting electricall using cord flexible3 core copper flexible cable of xize 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- (i) Contractor shall submitt LM 79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall conduct the inspetion of company rep. for material genuinety at site at no extra cost. Make :- Philips Cat Ref WT140W LED7S CW PSU S1 PC / Havells Cat Ref HEXAFT10WLED857SSYMBOPC/ WIPRO Cat Ref W07-141-XXX-57-XX
S&F in replacement home decorative LED wall lights 1X 6 W Xing hexa LED decorative,wall mounted die cast AI.LED fixture with ivory powder coating for updown accent lights etc with all accessories prewired and connected with 23/0.0076 three core PVC flexible cable etc including taking down of old light fitting complete all as specified and directed. Note :- (i) Contractor shall submitt LM 79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall conduct the inspection of company rep. for material genuinety at site at no extra cost. Make-Havells Cat part No - LHEHCYPBINIW006 or equivalent in Philips/ Wipro.
S&F in replacement of bldg security light fitting energy saving high efficiency LED street light fitting 20/25 Watts, 5700 K, IP 66, Having pressure die cast housing with toughened glass and individual hgh power LEDs with secondary optics, prismatic polycarbonate cover complete inclduding GI pracket of size 32 mm dia bent to shape having length on less than 1.2 mtr fixing with clamp et and making connections using cord flexible 3 core copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings or as directed. Note:- (i) Contractor shall submitt LM 79 & LM 80 test report from OEM owned NABL accredited laboratory .(ii) Contractor shall conduct the inspection of company rep. for material genuinety at site at no extra coast. Make: PHILIPS Cat Ref BRP022 LED 20 CW MR S1 PSU GR/ HAVELLS Cat Ref DURAPEARLSL25WLED757SASYTOPCMP/ WIPRO CAt Ref LR02-291-XXX-57-XX.
M & L for taking down and re-fixing existing ceiling fan after spary painting, providing new fan clamp, nuts/bolts, washers and provision of 3 core flexible cable from ceiling rose to fan connector complete all as specified and directed.
S & F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . Make:- Legrand / Schenieder/ Seimens
S & F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . Make:- Legrand / Schenieder/ Seimens
S & F MCB single pole 240 volts, 'C' curv of rating from 6 to 40 amps, with rupturing capacity 10 KA,including providing thimble for out going cables. Make:- Legrand / Schenieder/ Seimens
S & F MCB SPN 240 volts, 'C' curv of rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables. Make:- Legrand / Schenieder/ Seimens
S & F MCB TPN 240 volts, 'C' curv of rating from 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables. Make:- Legrand / Schenieder/ Seimens
M & L for replacement of existing U/S submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification. Make of copper wire: Polycab / Grandlay / Finolex.
M & L for replacement of existing U/S submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification. Make of copper wire: Polycab / Grandlay / Finolex.
M & L for replacament of existing old U/S earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore medium grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in soft/ loose soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
S & F LED smart Lamp 14 watt, 6500 K, 230 volts complete all as specified and directed. Make: Crompton/ Havells/ Phillips.
S & F LED smart Lamp 7 watt, 6500 K, 230 volts complete all as specified and directed. Make: Crompton/ Havells/ Phillips.
S & F sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a)MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series Note :- (i) The DB shall be VTPN series of Schenieder Cat Part No:- A9HVD04L or equivalent to Legrand/ ABB . (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii) Connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (vi) MCB's should have a same make as of DB.
S & F in replacement of MCCB 415 Volts, 50 Hz, 63 Amps 4 pole with rupturing capacity 16 KA including providing thimbles for out-going cables. Make:- Legrand / Schenieder/ Seimens
S & F in replacement of MCCB 415 Volts, 50 Hz, 100 Amps 4 pole with rupturing capacity 16 KA including providing thimbles for out-going cables. Make:- Legrand / Schenieder/ Seimens
M & L in replacement of old u/s service cable size 16 sqmm, twin core 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service complete all as spd and directed. Make:- Plaza/ Havells/Polycab.
S & F in replacement of existing unsv/ broken bakellite sheet cover 3 mm thick of size 5"x5" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box.
S & F in replacement of existing unsv/ broken bakellite sheet cover 3 mm thick of size 11"x9" all as required at including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box.
S & F in replacement of existing unsv/ broken bakellite sheet cover 3 mm thick of size 7"x4" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box.
S & F in replacement sheet metal single pole and neutral enclosure with socket, plug top complete with one single pole MCB of 20 Amps, 240 volts complete all as spd and directed. Make:- Legrand/ ABB/ Shneider.
M/s Sumer Associates
Balaji Associate
Star Enterprises
garg construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .