Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance JAMMU KASHMIR HORTICULTURAL PRODUCE MARKETING PROCESSING CORPORATION JKHPMC LTD HORTICULTURE DEPARTMENT JAMMU KASHMIR GOVERNMENT OPPOSITE PRESENTATION CONVENT SCHOOL RAJBAGH J K190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | Admitted-Finance |
| 2 | Admitted-Finance 43 SEC NO 5 GROUND FLOOR TRIKUTA NAGAR JAMMU JAMMU JAMMU KASHMIR 180012 | JAMMU | JAMMU AND KASHMIR | 180012 | Admitted-Finance |
| 3 | Admitted-Finance JAMMU KASHMIR HORTICULTURAL PRODUCE MARKETING PROCESSING CORPORATION JKHPMC LTD HORTICULTURE DEPARTMENT JAMMU KASHMIR GOVERNMENT OPPOSITE PRESENTATION CONVENT SCHOOL RAJBAGH J K190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹6.0 L
Closing Date
6 Mar 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ER. MUJIB A TAK
O/o DEPUTY DIRECTOR TOURISM MW, RESIDENCY ROAD, JAMMU
Face lifting of Jammu Tawi Golf Course, Sidhra by way of Electrification.
2021_Tourm_117625_3
e-NIT No. 54 of 2020-21 Dated 20-02-2021
Open Tender
Civil Works
Item Rate
30 days
SIDHRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
DEPUTY DIRECTOR TOURISM MW
Yes
16 Mar 2021
22 Feb 2021
6 Mar 2021
22 Feb 2021
6 Mar 2021
22 Feb 2021
120 days
Amount
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate suitable G.I box and earthing the point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable make Polycab, Anchor, Havell, Syska ,Biocon
Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate suitable G.I box and earthing the point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable make Polycab, Anchor, Havell,Syska
Group A
Group B
Group C
Wiring for circuit/sub main wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required Make Havells, KEI, Polycab, Gloster ,Biocon
2x1.5 sq.mm + 1x1.5 sq.mm earthwire
2x2.5 sq.mm + 1x2.5 sq.mm earthwire
2x4 sq.mm + 1x4 sq.mm earthwire
2x6 sq.mm + 1x6 sq.mm earthwire
Supplying and fixing following size/module, GI box alongwith modular base and cover plate for modular switches in recess etc. as required Make Havells, Legrand, Anchor roma ,Biocon
4 module (125mm x 75mm)
8 module (125mm x 125mm)
12 module (125mm x 125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as reqd.Make Havells, Legrand, Anchor roma, Biocon
4 module
8 Module
12 module
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as reqd.Make Havells, Legrand, Anchor roma,Syaka ,Biocon
Supplying and fixing 5A to 32A rating, 240/415 A, 10 KA, C curve, miniature circuit breakes suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make ABB, Havells, L&T, C&S , Biocon
Single pole
Single pole and neutral
Triple pole and neutral
Supplying and fixing following rating, double pole, 415 V, isolater in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. Make ABB, L&T, C&S, Biocon
Supplying and fixing following modular switch/ socket on the existing switch box/cover incld. connections etc. as reqd. Make ABB, L&T, Anchor(ROMA) , Biocon
5/6 A, Switch
15/16 A, Switch
3 pin, 5/6 A socket outlet
6 pin, 15/16A socket outlet
Supplying and fixing two module stepped type electronic fan, regulator on the existing modular plate, switch box including connections but excld. modular plate etc.Make Havells, Legrand, Anchor roma, Biocon
Supply, Installation, testing and commissioning of Ceiling Fans 48"inch fitting with extended pipe of 2-5 ft. as per requirement on site make Usha, Orient, Havells , Biocon
Rewiring of existing Fan motor. Job includes Installation and testing of fan as per requirement on site.
Supply, testing and commissioninng of 20 w, 220 V, wall mounted electronic LED tube make Jaquar, Philips, Osram.
Supply, installation, fixiing and commissioning of Slim surface /Recess LED flat panel light made extruded aluminium frame WARM WHITE light with high efficient LED and glass free opal diffuser make Jaquar, Philips, Osram.
Supply, testing, fixing and commissioning of 30 watt B22 warm white LED bulb to be fixed in already installed ornamental pole by way of providing holders and all necessery conection. The job also includes fixig of globes by providing water tight seal. Make Philips, Jaquar, Osram.
Repaire of all ready installed 24 volt double battery sine wave inverters by way of rectification/ replacing all defective parts and making it functional again. The job include pickup/installion at site
Supply, testing, fixing and commissioning of 12 volt 200 Amp Battery with 3 years warranty make Lumens / Exide
Supply, testing, fixing and commissioning of 150 watt high mast light with the help nut/bolt of appropriate size as per the instructions of Engineer-in-charge.Make Jaquar, Philips, Osram.
Servicing of Air Conditioner by way of cleaning, outdoor compressor and internal net of indoor unit
Supply, testing and commissioning of 12" Modular Exhaust Fan heavy duty make Havells, Orient, Usha or Equalant
Supply, testing, laying and commissioning of 16 sq.mm 4 core armoured cable by way of crimping of cable and attaching thimbles of Appropriate size.Make Gloster,Polycab,KEI
Supply, testing, laying and commissioning of 35 sq.mm 4 core armoured cable by way of crimping of cable and attaching thimbles of Appropriate size.Make Gloster,Polycab,KEI
Supply,fixing and commissioning of office bell wired/cordless. Make Anchor, Havells
Supplying and drawing following sizes of FRLS PVC insulated 4 core 6 sq mm armoured copper conductore in the existing surface/recessed steel/ PVC conduit as required. Make Havells, KEI,Biocon, Polycab, Gloster
Supplying and drawing following sizes of FRLS PVC insulated 3 core 6 sq mm unarmoured copper conductore in the existing surface/recessed steel/ PVC conduit as required. Make Havells, KEI,Biocon, Polycab, Gloster
Supplying, testing, commissoning and fixing of silent wall mounted fans make Usha, Orient, Havells or Equalant .
Supply, testing, fixing and commissioning of double battery 800VA UPS for personal computer with minimum backup of 25 -30 minutes. Make Luminous, Microtek , Intex.
Chemical Type Maintainance free earthing with 3 MTR 50 MM GI electrode with Conncetion with 25x3 mm GI Strip Make JMV/GMAX/OBO with CPRI Approved and NABL certified Test Report with PVC/FRP pit cover or Equalant. The value of the earthing must be between 1-3V
Supplying, Installation, testing and commissioning of 240 GB Solid State drive (SSD) in preently installed computers. Make HP, Samsung, Intel
Supplying, Installation, testing and commissioning of 480GB Solid State drive (SSD) in preently installed computers. Make HP, Samsung, Intel
Repair of charging points / thimbles of battery by way of fixing new thimbles. The job includes taking battery from site and installing same at site as it was earlier
Supplying, Installation, testing and commissioning of IP 65 5-8 watt Up Down warm white wall LED light. The Job include fixing of light with all necessory accessories required at site as per the instructions of engineer-in-charge. Make Jaquar, Phillips,Osram.
Providing servicing/maintance/ repair of already installed CCTV camra system by way of upgrading lost IP address and chacking connection of CAT6 cable & reconnecting by way of providing new contactors at termination points as per requirement of site.
Repair of installed 200 KVA Servo Steplizer from OEM by way of :-
Installing of 3 pole 325 Amp contactor
Repair of already installed contator by way of replacing coil
Display
Servo Motor
S M ELECTRICAL CO
AKIB AHMAD
Sumit Anand
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .