| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹29.5 L+₹4.0 L (15.9%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹35.9 L+₹10.4 L (41.0%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹36.0 L+₹10.6 L (41.6%)Rejected-Finance MAIN ROAD OBEDULLAHGUNJ RAISEN M P 464993 | OBEDULLAHGUNJ | RAISEN | MADHYA PRADESH | 464993 | L4 | Rejected-Finance Other than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in cat b (ii) |
Tender Value
₹42.7 L
EMD Value
₹85,400
Closing Date
5 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR/MAINTENANCE OF HT OH LINES, TRANSFORMERS, VCBs AND CONNECTED WORKS AT KARU AND SHESHARSHATHANG AREA UNDER GE 860 EWS
2022_MES_535027_1
138WE/L-36/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 860 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 860 EWS
₹85,400
Yes
20 Sept 2022
1 Jul 2022
12 Aug 2022
1 Jul 2022
5 Aug 2022
15 Jul 2022
Amount
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for laying of cable/stay assy/HT poles and getting out in hard/dense soil completed all as specifed and directed.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m depth and not exceeding 3.0 m depth for foundation of poles and getting out in hard/dense soil complete all as specifed and directed by Engr-in-Charge.
Returning filling in incl spreading watering and well ramming in layers not exceeding 25cm in hardand dense soil completed all as specifed and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specifed and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in foundation of poles/stay assy including use of necessary form works for rough finished surface complete all as specified and directed.
complete all as specified and directed by Engineer-In-Charge.
M&L PCC 1:2:4 type B-2 (using 40 mm crushed graded stone aggregate) as in coping of poles/ stay assy including use of necessary form works for rough finished surface complete all as specified and directed.
M&L Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed. Note: Punned thickness shall be measured.
M&L in replacement un-reinforced precast concrete cable cover, Class HV Type-I, flat, size 300mm x 180mm x 40mm, complete all as specified and directed.
M&L in replacement tubes galvanised in repair with all fittings and fixed complete to walls and ceilings or laid in floors/with pole/trenches "Light grade" 80 mm dia for the protection of the the U/G cable complete, all as specified and directed by Engineer-in-Charge.
Dismantling & taking down insulator any type any size from HT pole.
S&F polymer composite Pin insulator, grey in colour, dia of FRP rod 20mm, length of FRP rod (min) 165 mm, dia of weather sheds 100 mm as per IEC 61109 for 11000 volts grade.
S&F polymer composite disc type, grey in colour working pressure 11000 volts all as specifed and directed by Engr-in-Charge.
M&L for dehydration of transformer oil with mobile transformer filteration plant at site with all required accessories connected to transformer and carrying out filteration of transformer oil for the desired dielectric strength i.e not less than 45 KV at 2.5 mm gap all as directed by Engr-in-Charge. (Note : Test certificate shall be submitted before and after filteration for dielectric strenght).
Supply and Filling in replacement Transformer Oil of good quality for Topping Up Transformer 200 KVA to 630 KVA Capacity having dielectric strenght not less that 50 KV, flash point not less than 135 degree C, having low viscosity for filling or replaceing the old oil complete all as directed by Engr-in-Charge. (Make- Servo/Power Oil/HP)
M&L for shifting of 315 KVA/100 KVA out door type transformer from GE 860 to Div power house, TBS to GE 860 and placed on the platform made for the purpose and 11 KV on HT side, 433 Volts, 3 ph & 4 wire on LT side complete with electrical connections on HT & LT side including all the accessories/fittings and all as specified and directed by Engr-in-Charge. Note: (a) Platform of suitable size/as per site requirement be constructed to keep the transformers at new place. (b) The cost of the platform to be include in the quoted amount.
Dismantling of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc.
Dismantling burnt/defective Gang Operated Switch keeping away from site, Supply & install 11 KV 3 Phase Gang operated air break switch with drop out fuses set (consisting 12 Nos Post Insulator) 400 Amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, all as specified and directed.
Dismantling the existing damaged danger notice plate from the HT Poles keeping away from site and M & L danger noitce plate of 1.6 mm mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts of approved size for HT, 25x20 mm size.
M&L cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm.
M&L cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 185 sqmm.
M&L in replacement steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 mtr long)
S&F stay assembly set comprising of 14 mm long GI stay bow, 2150mm long stay rod 20mm dia with threaded end GI nut bolt and washers, thimble including 300x300x6mm MS stay plate and exposed surface shall be given tow coat of aluminium paint over a coat of red oxide primer complete including dismantling of existing damaged assembly complete with all accessories as shown in electrical plate No 1 of MES schedule part-I and as directed (excavation, earth work, PCC & insulator shall be measured and paid separately).
M&L in repalacement for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint of approved make.
Supply, laying, testing and commissioning in replacement PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 11000 Volts grade with stranded aluminium conductor of size 185 Sqmm x 3 Core confirming to IS 7098 Part-II, suitable for earthed system complete all as specified and directed. Note : 1. The ende ternination joint shall be measured and paid separately under respective items. 2. Excavation, earth work, sand cushioning and protection cover will be measured and paid for separately.
Supply, laying, testing and commissioning in replacement PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 11000 Volts grade with stranded aluminium conductor of size 95 Sqmm x 3 Core confirming to IS 7098 Part-II, suitable for earthed system complete all as specified and directed. Note : 1. The end ternination joint shall be measured and paid separately under respective items. 2. Excavation, earth work, sand cushioning and protection cover will be measured and paid for separately.
Supply and fixing in replacement aluminium conductor steel reinforced (ACSR) of any size, straining properly on insulators and binding on existing HT poles or new poles with and incl 02 mm dia aluminium binding wire all as specified and directed. Note : 1. The 3% for sag, joints & jumpers shall be added in measurements. (a) 1 of 6/1x3.00mm (ferret)
Disconnecting defective out door/indoor transformers, 11KV/433 V of 63 to 400 KVA from HT/LT sides taking down transformer oil in suitable container (to be provided by the Contractor), lifting the top cover and core assembly carefully and checking the conditions, refilling the transformer oil completely after necessary repairs like rewinding with copper wire, LT busing, HT bushing, breather assy, temperature gauge, tap changer and fixing the top cover and painting to transformer complete all as specified and directed. Note : In case of major repaires/replacement in transformer, which can not be undetaken at site, the transformer shall be shifted to civil workshop deemed to be included in Unit rate. After complete repair test report from auth agency will be submitted to Engr-in-Charge.
M&L in replacement Anti-Climbing device spike type fabricated out of MS bars (round, square and left) including nuts, bolts and washers and welding into two halves made to shape to suit the cross section of the pole.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less that 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, connecting to the galvanised iron strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron and galvanized iron strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC (1:2:4) type B-I (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 m long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement, funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to distance not exceeding 50 m, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to MCBDB's earth test point all as specified or indicated including testing on completion.
M&L for preparation old (exposed) painted surfaces of existing HT/LT steel tubular pole, struts including cross arms, clamps etc complete and applying two coats of aluminium paint over a coat of red oxide primer over the ground and making 30 cm wide strip with black and yellow paint including numbering of HT/LT poles at a height of 1.5 mtr above ground level as per existing having 15 mm width and 50 mm bold letter, complete all as specified and directed including Marking Red Stipn painting on HT Poles etc
M&L opening of the VCB, 11 KV 630/400 Amps of make Crompton greaves/ABB by removing of the breaker from the existing position after disconnecting all the connections from the system, servicing, overhauling of the same, checking of the same for proper operation, spring charge, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulators, fasten the bolts, checkig and correcting interrupting units, mechanism, linkages etc, fasten the harwares of control wiring, check that the split pins, Circlips, dowell pins etc. have not cone out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the shuttters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, controll limit switches reconnecting of the breaker for smooth functioning all as specified and directed.
Decarbunizing/cleaning complete HT 11 KV, 3 phase independent bus bar, chamber of HT panel electrification connection complete, HT VCB switch gear arrangement incoming and outgoing installed in sub-stations after removing the complete bus bar spout, circuit spout from the bus bar chamber, cleaning with CTC and ensure proper decarburizing, re-fixing the same after applying backtol (Red) solution to the spout, checking all the connection, tightening the nuts, bolts thimbles for incoming and outgoing system complete, replacement of damaged space heater along with thermostats, door/position limit switches, controll fuses and servicing/greasing to manual charging/spring charging mechanism line CTs. PTs and repalcement of damaged PT Fuses all as specified and directed, rate quoted is inclusive of bactol red, CTC & cotton waste provided by Contractor all as specified and directed..
S&F in replacement closing coil assembly 110V DC for VCB all as specified & directed.
S&F in replacement fix tripping coil 110V DC for VCB all as specified & directed.
S&F in replacement 11 Kv PT HV back up fuse cat No 12 Kv ABCNA 3.15A 38/10 as per OEM recommendation all as specifed & directed.
M&L for replacing existing unservicable silica jel with new crystal clean silica jel for the breathes of transformers capacity 50 to 630 KVA all as specified & directed by Engr-in-Charge.
Supply and replace unservicable (broken / cracked) breathers assy complete of various transformers suitable for pipe entry of 20/25 mm dia all as specified & directed by Engr-in-Chagre.(as per old sample)`
S&F in replacement oil temperature guage complete all as specifed & directed.
S&F in replacement MS chequared plate cover 10 mm thickness for cable duct including 2 coats of synethic enamel paint over a coat of red oxide primer complete all as specified and directed.
M/S MALIK CHAND SIRI RAM
EESSI
M/S KAMLA CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .