Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being Lowest and reasonable | |
| 2 | L2₹20.0 L+₹2.4 L (13.9%)Rejected-Finance WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹21.7 L+₹4.2 L (23.7%)Rejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹34.5 L+₹16.9 L (96.5%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | - | Rejected-Technical Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 Feb 2023, 6:00 pmClosed
CWE (AF) TUGHLAKABAD
HQ CWE (AF) TUGHLAKABAD NEW DELHI-110080
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY AND SUB STN INCLUDING CERTAIN FIRE FIGHTING WORKS AND ANNUAL MAINT OF LIFT AT BRD AF STN PALAM UNDER GE (AF) GURGAON NO.1
2022_MES_571768_1
CWE/TKD/GUR/TOKEN-44/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) GURGAON NO.1
As per NIT conditions
7 documents required · 7 mandatory
₹500
GE (AF) GURGAON NO.1
₹70,000
Yes
4 Mar 2023
28 Dec 2022
3 Feb 2023
28 Dec 2022
1 Feb 2023
18 Jan 2023
Amount
Phase-I
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 25x4 mm galvanised iron strip complete all as specified and directed.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of earthing lead of 4 mm dia galvanised wire complete all as specified and directed.
Supply and fixing in replacement of sprinkler Quick / Early response type as per IS 15105 / TAC guide lines, 79 degree temperature rating pendant type complete all as specified and directed.
Supply and fixing in replacement of Pressure switch of existing make and capacity complete all as specified & directed
Supply and fixing in replacement of stainless steel Single headed hydrant valve 63 mm dia, ISI marked of existing make complete all as specified and as directed.
Supply and fixing in replacement of RRL hose pipe ISI marked 15 mtr length, type A complete all as specified and as directed.
Supply and fixing in replacement of stainless steel Male Coupling complete all as specified and as directed. Make : NewAge fire, safeguard, ABC fire India/Reliance fire, Safepro or equivallent.
Supply and fixing in replacement of stainless steel Female Coupling complete all as specified and as directed.Make : NewAge fire, safeguard, ABC fire India/Reliance fire, Safepro or equivallent.
Supply and fixing in replacement of Short stainless steel pipe of existing all as specified and as directed. Make : NewAge fire, safeguard, ABC fire India/Reliance fire, Safepro or equivallent.
Supply and fixing in replacement of brass Nozzle for 20 mm pipe of existing make complete all as specified and directed.
S&F for external hose box (in repair) made of 18 gauge MS Sheet 800X 600X250mm with double door with 4 mm thick glass and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed. Make : NewAge fire, safeguard, ABC fire India/Reliance fire, Safepro or equivallent.
Supply and fixing in replacement of ISI marked MS ERW pipe C class of 150 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and directed.
Supply and fixing in replacement of ISI marked MS ERW pipe C class of 100 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and directed.
Supply and fixing in replacement of ISI marked MS ERW pipe C class of 80 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and directed.
Supply and fixing in replacement of ISI marked GI pipe C class of 25 mm dia including ISI marked GI fittings and testing complete all as specified and directed.
Supply and fixing in replacement of ISI marked GI pipe of 20 mm dia including ISI marked GI fittings and testing complete all as specified and directed.
Supply and fixing in replacement ISI Marked, 150mm size cast iron butterfly valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, cast iron 150 mm Sluice valve,PN 1.6 both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, cast iron 100 mm Sluice valve, PN 1.6, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, cast iron 80 mm Sluice valve, PN 1.6, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
M&L for 1.5 sqmm 3 core PVC insulated unsheathed, FRLS multistranded copper conductor cable, 1100V grade complete al as specified and directed.
M&L for removing of lubricating oil from chamber and oil filter chamber of the diesel driven pump 44 KW/55 KVA and cleaning of oil chamber & filter chamber thoroughly to remove all types of deposits and supply & filling of new lubricant oil SAE 15 W/40 W-20 liter at required level complete all as specified and directed.
Supply and fixing in replacement of Element lub oil filter of 44 KW/55 KVA DG complete all as specified and directed. Make:Mico/Fuel guard/Kirloskar/ Cummins/ Bosch OEM Cat No AX1001258
Supply and fixing in replacement of Fuel filter of 44 KW/55 KVA DGcomplete all as specified and directed. Make: Mico/Fuel guard/Kirloskar/ Cummins/ Bosch OEM Cat No AX1001368
Supply and fixing in replacement of Coolant assy of 44 KW/55 KVA DG complete all as specified and directed. Make:Mico/Fuel guard/Kirloskar OEM Cat No 4104821
Supply and fixing in replacement of Element Air cleaner of 44 KW/55 KVA DG complete all as specified and directed. Make:Mico/Fuel guard/Kirloskar/ Cummins/ Bosch OEM Cat No AX10013688260269
M&L for 2x4.00 Sqmm +1x4.00 Sqmm earth wire PVC insulated unsheathed , FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 (Part-1) drawn through and including ERW steel conduit of 20mm dia duly painted complete all as specified and directed.
Taking out induction motor from the system carrired out motor to work shop , Rewinding of Induction AC Motor, 440 volts , 50Hz, 03 phase, brusless of Rating 60 HP, with super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material complete all as directed and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete. Note :- rewinding shall be done with gurantee during the contract period. Any defects after rewinding shall be rectified by the contractor at his own expanses with copper enameled wire, refixing and testing the motor complete all as specified and as directed.
M&L for Spray Painting of Pump with Motor capaicity 45KW with synthetic enamel paint including preparation of surfaces complete all as specified and directed.
M&L in Spray Painting of Jockey Pump with Motor capaicity 10 HP with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L in spray Painting of Pump with DG Set capaicity 50 HP with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
M&L in replacement of Battery lead with Brass terminal complete of appropriate size as per site complete all as specified and directed.
M&L in replacement of 5000 Ltr Triple layer ISI marked PVC Tank including tank neeples of 40 to 50mm size and taking down existing unserviceable tank complete all as specified and directed.
M&L in replacement of 25 mm Gun Metal gate Valves complete all as specified and as directed.
M&L for Painting to 150 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
M&L for Painting to100 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
M&L for Painting to 80 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
M&L for Painting to 200 mm pipe as in header with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
Supply and fixing in replacement ISI Marked 150mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked 100mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, 80mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement of Heavy duty threaded/welded GI Flange with rubber gasket 150 mm including nuts and bolts complete all as specified and directed.
Supply and fixing in replacement of Heavy duty threaded/welded GI Flange with rubber gasket 100 mm including nuts and bolts complete all as specified and directed.
Supply and fixing in replacement of Heavy duty threaded/welded GI Flange with rubber gasket 80 mm including nuts and bolts complete all as specified and directed.
Supply and fixing in replacement ISI Marked,150mm cast iron Foot valve, with flanged jointed and tested including taking down old valve complete all as specified and directed.
M&L for Cleaning of 50000 Gallon overhead tank with 6 Stage Cleaning Method STAGE 1: Dewatering the water with Mechanical electric Pump. STAGE 2 : Clean the sluge from wall and floor of overhead tank. STAGE 3: High pressure cleaning with special pump. STAGE 4: Suction with Industrial Vaccum Cleaner. STAGE 5 : Anti bacterial Spray on wall and Floor of overhead tank ( Test Certificate Of Chemical Must be Provided That chemical is safe for Humans). STAGE 6: UV Radiation for disinfect from the bacterial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and directed.
M&L for Cleaning of 25000 Gallon semi UG Sump with 6 Stage Cleaning Method. STAGE 1: Dewatering the water with Mechanical electric Pump. STAGE 2 : Clean the sluge from wall and floor of sump. STAGE 3: High pressure cleaning with special pump. STAGE 4: Suction with Industrial Vaccum Cleaner. STAGE 5 : Anti bacterial Spray on wall and Floor of Sump( Test Certificate Of Chemical Must be Provided That chemical is safe for Humans). STAGE 6: UV Radiation for disinfect from the bacterial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and directed.
M&L for Cleaning of 5000 Ltr PVC Tank with 6 Stage Cleaning Method. STAGE 1: Dewatering the water with Mechanical electric Pump. STAGE 2 : Clean the sluge from wall and floor of PVC Tank. STAGE 3: High pressure cleaning with special pump. STAGE 4: Suction with Industrial Vaccum Cleaner. STAGE 5 : Anti bacterial Spray on wall and Floor of PVC Tank (Test Certificate Of Chemical Must be Provided That chemical is safe for Humans). STAGE 6: UV Radiation for disinfect from the bacterial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and directed.
Material and labour for painting of EOT crans installed above the height of 5.0m from working level, thoroughly cleaned of all dirt, grease, scale and rust by shot blasting or chemical cleaning methods, removing old paint from EOT cranes and attachments parts such as double girders, motors, crane rail, Gearbox cabinet, LT panel board and all moving parts. A single coat of primer shall be given to all parts exposed to the weathering effects and two coats of paint as approved by GE for indoor/outdoor cranes shall be given on all primer painted surface. The bright exposed parts of the crane shall be given one coat of rust inhibitor. Interior of all gear boxes shall be painted with one coat of oil resisting paint. Writing the Technical details of respective crane as per existing data available on each cranes with paint as approved by GE, complete all as directed. The capacity of Crans are as under :-
(a) EOT Crane 2.0 Ton
(b) EOT Crane 3.0 Ton
(c) EOT Crane 5.0 Ton
Labour only for taking down gear assembly connected induction motor, servicing, greasing of motors etc complete and dismantling gear box assembly taking out gear and other worn out parts, replacement of worn out parts replacement of gear oil over hauling, oil seal replacement including lathe work as required at site re-assembly, re-fixing the same and testing complete for the following capacity :- Note :-(i) Spares shall be measured and paid separately.
(a) Capacity 2 TON
(b) Capacity 3 TON
(c) Capacity 5 TON
Material and Labour for disconnecting the electric motor of capacity 3 HP from the cranes transporting to workshop, taking out old winding and rewinding the motor with super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete all as specified and directed.
Material and Labour for disconnecting the electric motor of capacity 5 HP from the cranes transporting to workshop, taking out old winding and rewinding the motorwith super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete all as specified and directed.
Testing of EOT/HOT cranes with full load and 25% over load all as specified in IS No 301 of 1977 and 3177 of 1977 and writing the date of load testing complete all as specified and directed for the following capacity :- (Note :- Contractor will be responsible for provision of load materials in P&E Lab)
(a) Capacity 2 TON
(b) Capacity 3 TON
(c) Capacity 5 TON
M&L for PVC insulated unsheathed , FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 (Part-1) of size 4 Sq mm, 10 Core Copper Conductor complete all as specified and directed.
M&L for PVC insulated unsheathed , FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 (Part-1) of size 2.5 Sq mm, 10 Core Copper Conductor complete all as specified and directed.
M&L for Variable Speed driver altivar 12 for synchronous motor of capacity 2.2KW/3HP with input voltage 380-500V-3 phase and output voltage-380-500volts-03 phase complete all as specified and directed. Make : Schneider Cat No ATV312HU22N4-01Nos or equivallent of Havells/L&T/C&S
SPARES PARTS Supply only Spares/Components after approval for the following capacity of Cranes/Hoists :- Crane Capacity 2 TON
(a) Carbon Brushes.
(b) Over Load Relay 5 to 10 Amps Make – L&T/Siemens/C&S/Crompton Greaves
(c) Brake Lining.
(d) Steel Wire Rope 10mm dia.
(e) Magnetic Coil.
(f) Clutch Plate .
(g) Thrust Bearing.
(h) Gear Wheel.
(j) Limit Switch .
(k) Roller Bearing.
(l) Push Button. Make L&T
(m) Oil Seal
Crane Capacity 3 TON
(a) Oil Seal.
(b) Gasket.
(c) Steel Wire Rope.
(d) Pedant Push Button .
(e) Carbon Brushes.
(f) Over Load Relay 13 to 21 Amps. Make –L&T/Siemens/C&S/Crompton Greaves
(g) Clutch Plate.
(h) Wheel Bearing Make SKF/NBC.
(j) Trolley Wheel.
(k) Brake Pad.
Crane Capacity 5 TON
(a) Oil Seal.
(b) Gasket.
(c) Brake Pad.
(d) Brake for LT/CT Coil.
(e) Pedant Push Button .
(f) Clutch plate.
(g) Over Load Relay 13 to 21 Amps. Make – L&T/Siemens.
(h) Brake lining.
(j) Limit Switch. Make – .L&T/Siemens/C&S/Crompton Greaves
(k) Key Switch. Make – L&T/Siemens/C&S/Crompton Greaves
(l) Gear Box Bearing.
(m) Gear Wheel.
(n) Magnetic Coil
Common Spares.
(a) HRC Fuse 32 Amps.
(b) HRC Fuse 16 Amps.
(c) HRC Fuse 10 Amps.
(c) HRC Fuse 2 Amps.
(d) FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1100 Volts grade of size 2.5 Sq mm, 4 Core Copper Conductor.
(e) FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1100 Volts grade size 2.5 Sq mm, 3 Core Copper Conductor.
(f) Indicator Lamp (RYB) as per sample
(h) Kit kat fuse assembly complete of 32 amps capacity
(j) TP Contactor 40 Amps, 110 Volts coil voltage ML-3. Make – L&T/Siemens/ABB
(k) TP Contactor 32 Amps, 110 Volts coil voltage ML-2. Make – L&T/Siemens/ABB
(l) PVC Insulated sheathed multistrand Copper conductor cable, 1100 volt grade of size 2.5 Sqmm, 12 core,
(m) No Volt Coil 110 Volts AC suitable for 40 Amps Contactor. Make-L&T /Siemens.
(n) Transformer 440/110 Volts, 30VA.
(o) PVC Insulated sheathed multistrand Copper conductor cable, 1100 volt grade of size 4 Sqmm, 12 core.
(p) M&L for MCCB TPN 63 Amps mechanical adjustable type breaking capacity 16 KA including fixing/connecting arrangement all as directed by Engineer-in-Charge.
(q) -Ditto- but capacity 32 Amps mechanical adjustable type, breaking capacity 16 KA.
Supply and fixing LED street light fitting of capacity 60 watts ,230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optic and equipped with IP 66 protection, with impact and corrsion resistant complete with drivers and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed. Make : Havell's cat No ENDURAOMNIPLUSSL60WLED 757SASYTOPC/Hallonix/Philips/CG
Supply and fixing LED street light fitting of capacity 90 watts ,230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optic and equipped with IP 66 protection, with impact and corrsion resistant complete with drivers and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed. Make : Havell's cat No ENDURAOMNIPLUSSL90WLED 757SASYTOPC/ Hallonix/Philips/CG
Supply and fixing 170 watt energy , saving environmental friendly, long life exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces, and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 including taking out of old unserviceable one, complete all as specified and directed. Make : Havell's cat No JETAIRISMAXFL180WLED757PWBLTG/Hallonix/Philips/CG
Supply and fix in repair thermal over Load relay MN2 type MN suitable for MNX contactor for 3 phase 415 volts AC supply of range 24-40 Amps capacity complete all as specified and directed. Make- L&T Cat Part No SS9414500F0 or equivallent of L&T/Siemens/C&S/CG including necessary electrical connection complete all as specified and directed.
Supply and fix in repair thermal over Load relay MN5 type MN suitable for MNX contactor for 3 phase 415 volts AC supply of range 66-110 Amps capacity complete all as specified and directed. Make- L&T Cat Part No SS9413700K0 or equivallent of L&T/Siemens/C&S/CG including necessary electrical connection complete all as specified and directed.
Supply and fix in repair front mounting Add-on-aux contact block MNX/MCX front Add-on aux contact bloxk MNX-0-80/MCX01-23, 1 No+1NC suitable for 240 volts AC supply including necessary electrical connection complete all as specified and directed. Make-L&T Cat Part No CS94118 or equivallent of L&T/Siemens/C&S/CG
Suppy and fix in repair Electronic Timer suitable for 240/360/415 V, 50HZ, for 3-30 Sec time setting including necessary connection complete all as specified and directed.
Supply and fix in repair contactor MNX40 suitable for 3 phase, 415 volts AC supply of capacity 40A of L&T cat Part No CS94190 or equivallent of Havell's, C&S, Legrand including necessary electrical connection complete all as specified and directed
Supply and fix in repair contactor MNX80 suitable for 3 phase, 415 volts AC supply of capacity 80A of L&T cat Part No CS97077 or equivallent of Havell's, C&S, Legrand including necessary electrical connection complete all as specified and directed
Supply and fixing LED post top lantern LED type of capacity 20 watts , 230 volt AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant comlete with drivers and lamp and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed. Make : Havell's Cat No RUBYMINIPT15WLED757PSYMTOPC /Hallonix/Philips/CG
Repair/Maintenance of 125 KVA DG set and servicing of DG sets including Alternator, Non AMF/AMF panels of connected DG sets for routine check up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning and carryingout the checking of engine oil level , oil bath cleaner oil level, draining sediments from fuel tank, checking of pre cleaner dust pan, air cleaner restriction, coolant level, record oil pressure, checking / tightening of all bolts/ nuts of engine and alternator, checking of AVM pads, diaphram coupling, air piping, cleaning of oil bath air cleaner tray screen,check / adjust belts, checking battery volatge, water level and apply jelly on terminals, checking fan hub/ air blower hub and water pumps, cleaning of electrical connections with CTC solution, checking of safety controls, cleaning of cooling system, cleaning of engine and radiator assembly, cleaning of roof, floor of the DG set room complete all as specified. Note: The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, distilled water, electrolyte, etc. All other spares will be measured and paid seperately as supply only under relevant items of this schedule, Contractor has to attend the break down at any time and place during the contract period. General maintenance is indicative only. Contractor has to carryout other necessary maintenance task also as required and directed by Engineer in Charge. Note : Break down to be attend and rectify within 3 hours of report failing which penality @ Rs. 1000/- per hour to be charged for delay.
All as per item no. 72 here in before but DG set of capacity 100KVA
All as per item no. 72 here in before but DG set of capacity 63KVA
All as per item no. 72 here in before but DG set of capacity 40 KVA
All as per item no. 72 here in before but DG set of capacity 25KVA
Suppy only the following spares parts of Make : Kirloskar complete all as specified and directed :-
Supply of oil filter for the DG set of capacity 125 KVA
Supply of oil filter for the DG set of capacity 100 KVA
Supply of oil filter for the DG set of capacity 63 KVA
Supply of oil filter for the DG set of capacity 40 KVA
Supply of oil filter for the DG set of capacity 25 KVA
Supply of fuel filter for the DG set of capacity 125 KVA
Supply of fuel filter for the DG set of capacity 100 KVA
Supply of fuel filter for the DG set of capacity 63 KVA
Supply of fuel filter for the DG set of capacity 40 KVA
Supply of fuel filter for the DG set of capacity 25KVA
M & L for repair and reconditioning of battery charger alternator kirloskar/ cummins make including taking out the defective alternator from 25 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing complete all as specified and directed.
M & L for repair and reconditioning of battery charger alternator kirloskar/ cummins make including taking out the defective alternator from 40 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing complete all as specified and directed.
M & L for repair and reconditioning of battery charger alternator kirloskar/ cummins make including taking out the defective alternator from 63 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing complete all as specified and directed.
M & L for repair and reconditioning of battery charge alternator kirloskar/cummins make including taking out the defective alternator from 100 KVA /125 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing complete all as specified and directed.
Supply only coolant for radiator suitable for DG set 25 to 125 KVA. Make- Cummins/ Kirloskar/ Ashok Leyland green,all as per manufacturers recommendations
M & L for fixing in replacment of fan belt set of 2 nos in 100/125 KVA DG set. Make : Kirloskar all as specified and directed by Engineer-in-charge
M & L for fixing in replacment of fan belt set of 2 nos in 25 KVA to 63 KVA DG set Make : Kirloskar all as specified and directed by Engineer-in-charge
Supply & Fixing in repairs High water temperature trip safety control make Kirloskar in DG set and connecting with DG set system of 100 KVA/125 KVA complete all as specifiied and directed.
Supply & Fixing in repairs Low lub oil pressure safety control make Kirloskar in DG set and connecting with DG set system of 100 KVA/125 KVA complete all as specifiied and directed.
M & L for reconditioning of lead acid battery of capacity 180AH 12 volts capacity by replacing the damaged cell, separator and filling diluted electrolite of appropriate concentration and charging complete all as specifiied and directed.
M & L for reconditioning of lead acid battery of capacity 150AH 12 volts capacity by replacing the damaged cell, separator and filling diluted electrolite of appropriate concentration and charging complete all as specifiied and directed.
M & L for reconditioning of lead acid battery of capacity 130AH 12 volts capacity by replacing the damaged cell, separator and filling diluted electrolite of appropriate concentration and charging complete all as specifiied and directed.
M & L for replacement of battery brass terminal with nuts and bolts complete all as specified and directed.
M & L for replacement of battery lead 1.50 Mtr long consisting of multistranded copper conductor PVC insulated single core cable of 50 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end complete all as specifiied and directed.
M & L for replacement of battery lead 1.50 Mtr long consisting of multistranded copper conductor PVC insulated single core cable of 35 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end complete all as specifiied and directed.
M & L for supply, fixing and testing DG set stop solenoid switch in 25/30/45/62.5/82.5 KVA by taking out the defective switch from the DG set, replacing by new and aligning, connecting with circuit, starting and testing complete all as specifiied and directed.
M & L for fixing in repair coil electrical in STC control valve under make Cummins part no.4963341 i125 KVA DG set complete all as specifiied and directed.
M & L for fixing in repairs phase indicator lamps R Y B LED type complete all as specifiied and directed.
M & L for fixing in repairs to Lub oil pressure transducer make Cummins Part no.3392445 in 100/ 125 KVA DG set and connecting with DG set system complete all as specifiied and directed.
M & L for fixing in repair shutdown valve under make Cummins part no. 3239599 in 100 / 125 KVA DG set complete all as specifiied and directed.
M & L for fixing in repair Air filter of 40 KVA/63 KVA DG set complete all as specifiied and directed.
M & L for fixing in repair Air filter of 100/125 KVA DG set complete all as specifiied and directed.
M & L for fixing in repair Air filter of 25/30 KVA DG set complete all as specifiied and directed.
M & L for repair and reconditioning the starting motor 12 V DC system of kirloskar make including taking out the defective starter from 125KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bushes, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing complete all as specifiied and directed.
M & L for supply and fixing of AMF Logic conttroller (Microprocessor based type) by taking out the defective unit from 63 KVA capacity DG set complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing complete all as specifiied and directed.
M & L for supply, installation testing and commissioning of AVR in 100 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load complete all as specifiied and directed.
Taking out ACB breaker for repair and servicing by disconnecting and dismantling the ACB breaker rating 2000 Amps / 800 Amps make L&T by carrying out repair/ servicing , checking and renewing the defective shunt trip coil & UV trip 415 V AC , checking and rectifying the defective CTs and rectifying the mechanism operation including spring charge system, reinstalling the same in the panel and providing necessary line and connections complete all as specifiied and directed.
Supply & Fixing in repair and rewinding the excitor stator assembly of 63 KVA capacity DG Set by takingout complete burnt coils, cleaning and rewinding the same by supper enamel copper wire SWG 18, insulalting the coils with nomex paper, milinex sheet, heating and varnshing by varnish materials and applying one coat of becktol anti rust protection, fixing back in to the alternator, connecting teh cables, starting and testing bectol anti rust protection
M & L for supply, installation and connection including taking out U/S battery charger 230 V AC input and output 24 V / 12 V 10 amps charging rating IMPS type with fully auto control in charging and floating with boost system bectol anti rust protection
Repair overhauling & removel of leakage from radiator & refixing it duly repaired, cleaning descaling ,welding brazing etc. including Replacement of rubber hoses & clips etc. complete in all respect of the followling capacities of DG sets :-
(a) 25 KVA to 40 KVA
(b) 63 KVA to 100 KVA
M&L for Spray painting of DG sets , Alternator , Panel ,diesel tank and base frame etc. with one coat of synthetic enameld paint as per MES colour code after complete removal of old painted surface duly rubbing of old paint and making surface for painting etc complete all as specified and directed for the following capacity DG set.
(a) 25 KVA to 40 KVA
(b) 63 KVA to 100 KVA
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out soft/loose soil for foundation of stay, laying of cable etc. complete all as specified and directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed
Material and labour for fly ash/burnt Bricks, sub class 'B' dry, well brunt bricks laid in trenches for cable protection complete all as specified and directed
M&L for 23 cm sand filling in trenches for cushioning of cable complete all as specified and directed. Note- Punning depth of 18 cm will be measured and paid.
M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregates for filling in road cuts/hard standing etc complete all as specified and directed.
Taking up old serviceable/ UG cable from trench for replacement, repair and re-laying or re-routing of size 70 sqmm to 95 Sqmm 3.5 core complete all as specified and directed.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminum conductor 1100 volts grade with cross sectional area of size 70Sqmm 3.5 core with screened, pvc bedded, galvanized steel strip or wire including laying in trench, passing through pipe, bone and road and complete all as specified and directed.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminum conductor 1100 volts grade with cross sectional area of size 50 Sqmm 3.5 core with screened, pvc bedded, galvanized steel strip or wire including laying in trench, passing through pipe, bore and road and clamping on wall with clamp at a gap of 02 feet complete all as specified and directed.
Boring of holes under road, pavement, hard standing for more than 5 mtr in length by trenchless, technology using ultra sound technique and necessary machine, including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
S & F GI tubing 40 mm dia light grade in protection of cable of different dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etccomplete all as specified and directed.
Taking down old unserviceable distribution board of any size and any capacity inculding disconnection of necessary electrical connection complete and make good the distrubed surface to the existing surface complete all as specified and directed.
Supply and fixing sheet metal enclosure double metal door factory made TPN 415 volt 4 way suitable for fixing MCB as outgoing and MCCB TP 63 to 125 Amps 16 KA mechanical type as main incoming duly painted all as specified including necessary electrical connection and flush in wall with necessary pcc works and make good the distrubed surface with existing surface complete all as specified and directed.
S&F in replacement of MCCB 3 pole mechanical type, capacity 125 Amps with breaking capacity 16 KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing complete all as specified and directed. Make:- Havells/ Indoasian/ ABB/Legrand
All as per item No 123 above but SP 5 to 32 Amps ,240 Volts complete all as specified and directed. Make Legrand/Havells/Schneider
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore light grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 8 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh, 20 mm bore galvanised iron pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to earthing lead of 4 mm dia galvanised iron by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 15 mm bore light grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 8 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh, 20 mm bore galvanised iron medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion complete all as specified and directed.
Supply and fixing LED post top lantern LED type of capacity 40 watts , 230 volt AC outdoor tye with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant comlete with drivers and lamp and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed. Make : Havell's Cat No RUBYPT40WLED757PSYMTOPC /Hallonix/Philips/CG
Phase-II
Comprehensive maintenance of electrically operated lifts of 01 No in 13 BRD Tech Area of Ground+1 Floor (Total landings) with electric power operated doors, auto clectric levelling device of capacity 08 passengers / 544 Kgs, electrically operated with automatic doors, installed at comn lab , 13 BRD Tech Area complete all as specified and as directed by Engr-in-Charge. Make: THYSEN Note for Ser Item No .61 : (a) The The unit rate quoted is deemed to be inclusive of the following: (i) Greasing & oiling to all mechanical parts, ARD maintenance, top up of hydraulic oil, steel ropes, checking of cabin movement, door movement etc. (ii) Replacement of spare parts like ARD, ARD batteries, mother board, control panels (both inside and outside lift), LEDs, push buttons, switches, door locks, door drives, steel rope, car drive parts, ceiling lights and fans and all other parts as and when found defective. (iii) Technician/ Supervisor/ Service Engineer charges as and when services are provided. (b) The job has to be carried out on Monthly basis and test reports to be submitted to Engineer-in-Charge. Notes for Ser Item No. 94:- (a) The above maintenance item includes complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as require for smooth and effcient functioning of the equipment/lift. Cost of all spares items are deemed to be included in the quoted rates. (b) The maintenance of lift shall be done through (OEM), the tenderer has to submit intent of MOU within fifteen days of acceptance of tender failing which the contract will be liable to be cancelled and work shall be excuted at risk & cost of the contractor. Contractor will conclude AMC with OEM and copy of the agreement will be submitted to Engr-in-charge and GE before commencement of AMC. no payment shall be made to contractor without submission of valid AMC agreement. (c) The contractor/OEM will provide mechanic and this mechanic shall be available round the clock i.e. 24 hrs for emergency break down attendance and rescue of trapped persons all as directed by Enginr-in-Charge. (d) The contractor shall obtain signature of Authorized Representative of GE and in token of satisfactory completion of defects. Any minor complaint requiring no spare part, shall be rectified within 2 hour & if requiring minor parts, shall be rectified within 4 hrs. Any major complaint requiring major spare part/repair, shall be rectified within 48 hours. In case delay in rectification of any minor complaint, a panel recovery @ Rs 100/- per hour shall be imposed upon the Contractor & in case of delay in major repair of the lifts for more than 48 hours & up to 10 (Ten) days, penalty on the Contractor for a sum of Rs. 2000/- per lift per day. (e) Passenger lift Qty 01 Nos PMC (Health Checkup Machines) replacement parts initial to be cost included this Job and no extra cost shall be paid by the govt on this account.
Comprehensive maintenance contract visit for lean lift 250kg, Qty 3 Nos(3 Lean Lift) in 27ED Palam by Expert Engineer of the firm of MOU as per Sch-'A' Notes including servicing, overhauling & repair if any required with replacement of all unserviceable parts to keep full functional throughout the month complete all as specified and as directed by Engineer-in-charge. MAKE : NEELKAMAL Note:- (i) The lift shall be maintained in serviceable condition through out the contract period (ii) Contractor shall provide MOU with the firm as specified in Sch'A' Notes for maintenanace support of Lean lift of capacity 250Kg for 11 Months within 15 days of date of commencement of the contract. If any item required for maintenance of lean lifts is not under scope of MOU that item shall be provided by the contractor at his own cost for above said MOU period. (iii) Comprising of regular servicing of lifts to keep the lifts in a serviceable/ functioning condition. iv) Engineers attending to maintenance of lean lift shall have expert credentials with relevent certification and the same shall be provided for inspection before attending to lift complaints. (v) Lean lift Qty - 3 Nos PMC (Health Checkup Machines) replacement of parts initial cost included this job and no extra cost shall be paid by the govt on this account. (vi) The contractor shall obtain signature of authorized representative of GE and in token of satisfactory defects. Any minor complaints requiring no spare part shall be rectified within 2 hour and if requiring minor parts, shall be rectified within 48 hours. In case delay in complaint requiring Major spare part/repair shall be rectified within 48 hours. In case delay in rectification of any minor complaint a panel recovery @ Rs 100/- per days shall be imposed upon the contractor & in case of delay in major repair of the lifts for more than 48 hours & upto 10 (Ten) days, penalty on the contractor for a sum of Rs 2000/- per lift per day.
Schedule of Credit
SANWARIYA ENTERPRISES
M/S PARKASH ENTERPRISES
DHARAMRAJ BUILDERS & ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .