| 1.00 | Providing & Fixing of Horizontal centrifugal split casing pumps with double entry impeller design Storm Water pump set with motor of suitable HP discharge 13000 LPM, Head 16 mtr.
A) Storm water pump set
Storm Water Pump set 13000 LPM 16 Mtrs Head (at Sandasar Disposal) | 1 | Each | - |
| 2.00 | Storm Water Pump set 6500 LPM 16 Mtrs Head (at Sandasar Disposal) | 2 | Each | - |
| 3.00 | Storm Water Pump set 13000 LPM 20 Mtrs Head (at HUDA Complex Disposal) | 1 | Each | - |
| 4.00 | Storm Water Pump set 6500 LPM 20 Mtrs Head (at HUDA Complex Disposal) | 2 | Each | - |
| 5.00 | (A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items.
(A) For Storm Water Pump set 13000 LPM 16 Mtrs Head 2 Nos.
a) Main switch 200 Amp 2 No.(L&T Siemens, ABB)
b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T)
C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T)
D) CT 100/ 3 Nos. (AE/KAPPA/L&T)
E) VSS 1 No.& ASS 2 No. each of approved make
F) SPP 2 No. of approved make
g) Motor starter, Star delta 2 No.for 13000 LPM 16 Mtr
H) Capacity KVAR as per site requirement 2 No.
I) Indicating Lamp - One Set
J) Change Over switch 200 Amp = 2 No. | 2 | Job | - |
| 6.00 | (A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items.
(A) For Storm Water Pump set 6500 LPM 20 Mtrs Head 4 Nos.
a) Main switch 200 Amp 2 No.(L&T Siemens, ABB)
b) Volt meter 100x100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T)
C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T)
D) CT 100/ 3 Nos. (AE/KAPPA/L&T)
E) VSS 1 No.& ASS 2 No. each of approved make
F) SPP 4 No. of approved make
g) Motor starter, Star delta 2 No.for 6500 LPM 20Mtr
H) Capacity KVAR as per site requirement 4 No.
I) Indicating Lamp - One Set
J) Change Over switch 200 Amp = 4 No. | 4 | Job | - |
| 7.00 | Diesel Generating Set
Providing & installing of 250 KVA Generating Set at HUDA Complex Disposal & Sandasar Disposal (1 at each site including civil work of foundations) Rohtak as per Specification in the DNIT and as per relevant standards.
The rating should be at 1500 RPM
(a) Diesel Engine b) Alternator c) Bettery 24 V
(d) Base Plate
(e) 1x120 sq mm 3.0 core XLPE Aluminum = 20 m
(f) Tools
A.M.F. PANEL
(a) Motorised change over switch 250 Amp 4 P with fuse base and HRC links 250 Amp.
(b) Under voltage/ over voltage relay - 2 No. 415 VAC
(c) Engine Start relay 24 VDC 1 No.
(d) Electronic Timber 24 VDC 1 No.
(e) Electronic Timber 24 VDC 2 No.
(f) Auxiliary relay 220 VAC - 2 No.
(g) Auxiliary relay 220 VAC - 3 No.
(h) Metering set 415 VAC - 1 set (Amp. Meter, Volt Meter, ASS, VSS, Phase Indicaters, Control fuse, frequency meter, CT'S)
(i) Metering set 24 V DC (Amp. Meter, Volt Meter)
(j) Over Load protection for DC - 1 No.
(k) Battery Charger 24 V DC (Blueron make)
(l) Copper bus bar of suitable size
(m) KWH meter 96 square mm size
(n) Starting fuse button and key switch (On/Off)
(o) Engine Protection unit with Audiovisual alarm and shut down for low lubricating oil pressure and high coolant temperature.
(p) Indicating lump for low lubricating oil pressure high coolant temperature, set running, load on, DC control on.
Note: Control Panel shall have the provision to provide auto manual failure panel (AMFP). | 2 | Each | - |
| 8.00 | Supply erection testing of light fittings including wire in the pump chamber with material upto 10 points including switch button plug PVC conduit pipe & copper wire etc. as per approved specifications complete in respect. | 2 | Job for 20 Points | - |
| 9.00 | Providing & fixing Exhaust fan 18" i/d (450 mm) complete with suitable GI sheet of approved make complete in respect. | 8 | Each | - |
| 10.00 | Providing & fixing of Ceiling fan 1400 mm (56") with speed adjuster of reputed make (Make Crompton, Usha, Bajaj, Orient) complete in respect. | 12 | Each | - |
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
18 Jul 2020, 4:00 pmClosed
Executive Engineer
Public Health Engineering Division No.3, Rohtak
Laying of DI Pipe 450 mm rising main from HUDA Complex to carrier channel on Jhajjar Road and from Bhiwani Stand to main Disposal, Repair and replacement of 400 mm dia RCC NP3 pipe near D Park Providing and Fixing pumping sets etc...
2020_HRY_135440_1
Laying of DI Pipe
Open Tender
Civil Works
Works
540 days
Rohtak
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
EE PHED-3 Rohtak
₹4.4 L
Yes
20 Jul 2020
13 Jul 2020
20 Jul 2020
13 Jul 2020
18 Jul 2020
13 Jul 2020
Amount
Providing & Fixing of Horizontal centrifugal split casing pumps with double entry impeller design Storm Water pump set with motor of suitable HP discharge 13000 LPM, Head 16 mtr. A) Storm water pump set Storm Water Pump set 13000 LPM 16 Mtrs Head (at Sandasar Disposal)
Storm Water Pump set 6500 LPM 16 Mtrs Head (at Sandasar Disposal)
Storm Water Pump set 13000 LPM 20 Mtrs Head (at HUDA Complex Disposal)
Storm Water Pump set 6500 LPM 20 Mtrs Head (at HUDA Complex Disposal)
(A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. (A) For Storm Water Pump set 13000 LPM 16 Mtrs Head 2 Nos. a) Main switch 200 Amp 2 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS 1 No.& ASS 2 No. each of approved make F) SPP 2 No. of approved make g) Motor starter, Star delta 2 No.for 13000 LPM 16 Mtr H) Capacity KVAR as per site requirement 2 No. I) Indicating Lamp - One Set J) Change Over switch 200 Amp = 2 No.
(A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. (A) For Storm Water Pump set 6500 LPM 20 Mtrs Head 4 Nos. a) Main switch 200 Amp 2 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS 1 No.& ASS 2 No. each of approved make F) SPP 4 No. of approved make g) Motor starter, Star delta 2 No.for 6500 LPM 20Mtr H) Capacity KVAR as per site requirement 4 No. I) Indicating Lamp - One Set J) Change Over switch 200 Amp = 4 No.
Diesel Generating Set Providing & installing of 250 KVA Generating Set at HUDA Complex Disposal & Sandasar Disposal (1 at each site including civil work of foundations) Rohtak as per Specification in the DNIT and as per relevant standards. The rating should be at 1500 RPM (a) Diesel Engine b) Alternator c) Bettery 24 V (d) Base Plate (e) 1x120 sq mm 3.0 core XLPE Aluminum = 20 m (f) Tools A.M.F. PANEL (a) Motorised change over switch 250 Amp 4 P with fuse base and HRC links 250 Amp. (b) Under voltage/ over voltage relay - 2 No. 415 VAC (c) Engine Start relay 24 VDC 1 No. (d) Electronic Timber 24 VDC 1 No. (e) Electronic Timber 24 VDC 2 No. (f) Auxiliary relay 220 VAC - 2 No. (g) Auxiliary relay 220 VAC - 3 No. (h) Metering set 415 VAC - 1 set (Amp. Meter, Volt Meter, ASS, VSS, Phase Indicaters, Control fuse, frequency meter, CT'S) (i) Metering set 24 V DC (Amp. Meter, Volt Meter) (j) Over Load protection for DC - 1 No. (k) Battery Charger 24 V DC (Blueron make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (On/Off) (o) Engine Protection unit with Audiovisual alarm and shut down for low lubricating oil pressure and high coolant temperature. (p) Indicating lump for low lubricating oil pressure high coolant temperature, set running, load on, DC control on. Note: Control Panel shall have the provision to provide auto manual failure panel (AMFP).
Supply erection testing of light fittings including wire in the pump chamber with material upto 10 points including switch button plug PVC conduit pipe & copper wire etc. as per approved specifications complete in respect.
Providing & fixing Exhaust fan 18" i/d (450 mm) complete with suitable GI sheet of approved make complete in respect.
Providing & fixing of Ceiling fan 1400 mm (56") with speed adjuster of reputed make (Make Crompton, Usha, Bajaj, Orient) complete in respect.
Chain pulley blocks of 3.00 Tones capacity with traveling trolley of appropriate lifting capacity for handling of pumping sets, capable of moving along the girders already provided for MPS span 8.6 Mtr. each.
Restoration of Water Supply Connection & other Utility damaged during the execution of work at site.
Restoration of Sewer Connection & other Utility damaged during the execution of work at site.
Bidder Name
Amount
Naresh Kumar Contractor
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 23.11 MB
BOQ_183386.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .