Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹21.1 L Quoted ₹21.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.8 L+₹1.2 L (5.52%)Rejected-Finance NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹22.8 L+₹1.2 L (5.52%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹24.7 L+₹3.1 L (14.3%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹24.7 L+₹3.1 L (14.3%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹25.5 L+₹3.9 L (17.9%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹25.5 L+₹3.9 L (17.9%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹25.5 L+₹3.9 L (18.0%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹25.5 L+₹3.9 L (18.0%) | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
11 Jun 2022, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
REPAIR MAINTENANCE AND REPAIR REPLACEMENT OF LT PANEL CABLE SERVO STABLIZER WITH MCCB STARTER AND ALLIED WORKS FOR PUMP HOUSE AT AF STN UDHAMPUR
2022_MES_516115_1
GE/AFU-56/2021-22
Open Tender
Civil Works
Item Rate
270 days
udhampur
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹60,000
Yes
12 Aug 2022
9 May 2022
13 Jun 2022
9 May 2022
11 Jun 2022
23 May 2022
Amount
Daily comprehensive maintenance of external and internal electrical distribution network in the AFLS and runway lights alongwith minor excavation, returning & filling work, jointing of cable, insulating/taping etc for 08 Hrs (Day working time i.e. 0900 Hrs to 1700 Hrs) complete all as specified and directecd by Engineer-in-Charge. Required T&P including safety belts, insulated pliers, spanners, screws drivers, insulated cutter, hand gloves, bolts,ladder and any others T&P requred at site to repair/maintenance the system shall be arrangement of cotractor and rates shall be deemed included in quoted for 08 (Eight) Hrs repair/maintenance works. Notes:- (a) T&P required for electrical services in runway i.e wooden bamboo, ladder, safety belts, shock proof shoes, rubber gloves or any other safety measures and safety tools etc shall be arranged by the contractor without extra cost to Govt. Contractor shall be solely responsible for any mishap, accident, and loss to life of the workmen engaged in the work. Nothing extra shall be admissible on this account. (b) Any minor fault which does not required major stores upto Rs 100 (Rupess Hundred only) shall be rectified by the contractor. (c) Contractor supervisor will noted the complaint in the complaint book and will be recorded in Register, same will be put up to the Engineer-in-Charge through JE E/M. (d) Lt cable/Joint kit or others related store shall be measured and paid separately
Supply, installing, testing and commissioning od CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS Section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel.The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp insulated copper strip of length not less than 60 cm and of size not less than 50x6 mm for 03 phase and neutral with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings- 01 srt of 4 strips INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter push button type- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type - 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 250 Amps 36 KA , ICS 100% of ICU, 0.8 In to 1 In, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50Hz,=01 No. OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA, ICS 100% of ICU, in 4 Pole, 415 volts , 50Hz,=03 Nos.,(ii) MCCB 63 Amps 16 KA, ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole 415 volts , 50Hz,=03 Nos.,(ii) MCCB 40 Amps 16 KA, ICS 100% of ICU, in 4 Pole with 415 volts , 50Hz,=02 Nos. Make of MCCB:-L&T/ Siemens / Legrand The panel manufacturer should have following Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS Section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel.The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp insulated copper strip of length not less than 60 cm and size not less than 50x6 mm for 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter push button type- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 250 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50Hz,=01 No+B10 OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., ICS = 100% ICU (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. Make of MCCB:-L&T/ Siemens / Legrand The panel manufacturer should have following Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel.The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp insulated copper strip of length not less than 60 cm and of size not less than 50x6 mm for 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter push button type- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-200A, with Amp meter push button type- 01 Set. (iii) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 160 Amps 36 KA , ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50Hz,=01 No OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 No., ICS = 100% ICU (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 No. Make of MCCB:-L&T/ Siemens / Legrand
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel. The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp insulated copper strip of length not less than 60 cm and size not less than 50x6 mm for 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter push button type- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-400A, with Amp meter push button type- 01 Set. (iii) C.T's 400/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 400 Amps 36 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50Hz,=01 No OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=04 Nos., ICS = 100% ICU (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=03 Nos., (ii) MCCB 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. Make of MCCB:-L&T/ Siemens / Legrand The panel manufacturer should have following Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
M & L for installing/erecting of octagonal galvanised iron pole suitable for security/street light including single arm standard bracket, 'J' type bolts, Excavation, Returing and filling works and removal of surplus soil to a distance not exc 50 mtr complete with PCC (1:3:6) type C-2 foundation of size 60x60x90 cm, size of pole 07 mtr height Hot deep galvanised octagonal pole with 130 mm bottom A/F 70 mm top A/F, made upto 03 mm thick HT sheet alongwith base plate (with bracket) including 1 mtr long hot dip galvanised single arm standard bracket made upto 40 NB dia GI pipe suitable to mount on pole all as specified and directed by Engineer-in-Charge. Make : Bajaj cat part No Bajaj or its equivalent to C.G/Surya.
Repair and replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, PF>= 0.90, lumen efficacy >= 100 lumen/watts, 5700 K, including new lights to be fixed in existing bracket at existing pole/bldg or other extra welding works complete all as specified including taking down old. Make : Havells/Bajaj/Wipro/C&S/Crompton/Polycab
Supply and fixing of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) as mentioned in Part -I of SSR 2020 including bituminous painting internally and exteernally upto the planting depth of poles with two coats black & white paints in straps 5 x 30cm alternatively all round the poles from the bottom complete all as specified & directed.
S & F street light bracket made out of 40/50 mm dia GI heavy grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut bolts and washers all as specified and directed including taking down old.
Supply and fixing MCB Distribution of SMC base, SMC door connected single door thermoplastic IP54 dust proof jet water tight corrosion proof, halogen & silicon free with high quality earth and neutral links internally embedded gasket for led and enclosures made pur with cable glands and other accessories with MCB SPN 10 amps and required terminals, metric size knock transparent door & with cable enerty covered and suitable to accommodate (Flame retardant self existing buishing of size mm complete all as specified and directed including taking down old. Model GSJB 2525
Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick MS sheet for outer shell and 2 mm thick for inner shell having TPN copper busbars of rating 400 Amp Cap.Bottom base channel of MS section not less then 100mmx50mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 100 Amp,4 pole, not less then 60 CM long mounted on insulators for incoming supply - 1 Set Set of 4 strips) (b)Phase indicator lamp RYB LED type - 1 Set Incoming: (a) MCCB 320 Amp 415V,50 Hz, FP, ,36 ka, Ics= 100% Icu with thermal, magnetic trip, adjustable type overload settings: 0.67 - 1.0 x In , short circuit setting release 6 to 12 ln
Disconnecting and dismantling the electrical connection and shifting of Lt Panel boards by disconnecting incoming and outgoing cable including all accessories including nut, bolt, washer and thimble etc complete and refixing of the Lt panel on staging by embedding the panel legs minimum 3 cm in ground/staging and adding a layer of PCC 1:2:4, 100 mm thick all as specified and directed by Engr-in-Charge.
Disconnecting and dismantling the electrical connection and shifting of electrical poles by disconnecting incoming and outgoing cable including all accessories complete and refixing the pole by excavation, returning & filiing and removal of any type of soil including PCC 1:3:6 type C-2 with using 40 mm graded crushed stone aggregate as in foundation and PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping etc for all as specified and directed by Engr-in-Charge
Repair/maint and overhauling of L.T.Panel 3 phase AC 415V, 50 Hz A of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp meter, phase indicator LED lamp,Change over switch of any capacity ,burnt out copper winding ,current coil ,potential coil and keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of parts including removal of old paint with 02 coat synthetic enamel machine spray paint after 01 coat iron red oxide machine spray paint along with replacement of unsv nuts, bolts, thimbles, gasket etc as per site requirement including denting, welding and replacement of unsv hinges if requirement complete testing all as specified and directed by Engineer-in-Charge. Note : (a) All spare parts and control wiring will be measured and paid seperately under respective item of Sch 'A'. are as under. (b) Denting, welding, replacement of unsv hinges, locking arrangement, handle, unsv gasket, cable gland, nut, bolt, washer, minor repair of PCC foundation if required and removing of old paint alongwith reassembling, testing, commissioning etc shall be deemed included into the quoted rate.
MCB TPN capacity 32 Amps, 415V, 50 c/s 16 KA-01 No. Make : Legrand / Schnieder / L&T
MCB SPN capacity 32 amp, 'C' series-02 Nos Make : Legrand / Schnieder / L&T
Set of indicating lamp LED type-01 Set.
Civil work PCC 1:2:4 for grouting of panel complete Size- (0.25x0.25x0.25 cum x 04) including excavation, earth work.
Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 40mmx5mm
Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 50mmx6mm
Current transformer of suitable size as per existing
M&L for cutting the existing cable from loop and existing panel and installing heat shrinkable sleeves over the existing cable suitable for LT U/G cable of size 25 to 50 Sqmm and reconnection of cable in panel etc all as directed by Engr-in-charge.
Copper wiring 2.5 Sqmm as per existing size
Supplying and fixing in repair, connecting, testing and commissioning rupturing capacity, Material and labour for MCCB 4 Pole, 415 V, thermal magnatic load, ICS 100% of ICU, 100 Amps with breaking capacity 16 KA including all accessories all as specified and directed by Engineer-in Charge. make Schneider ,cat part No LV510317/Havells/L&T/Standard/Legrand or equivalent as approved by GE.
Supplying and fixing in repair, connecting, testing and commissioning rupturing capacity MCCB 160 Amps , FP , 415 Volts, 36 KA, 50 Hz including spreader terminals complete all as specified and directed
Supply and fixed in repairs MCCB 200 Amps, 415 volts AC 50Hz, 4 pole, bracking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
Supply and fixing in repair, connecting, testing and commissioning rupturing capacity, Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 250 Amps with breaking capacity 36 KA as per IEC60947-2 @ with suitable size of sheet metal enclosure including all accessories all as specified and directed by Engineer-in Charge. make Schneider ,cat part No LV52543/Havells/L&T/Standard/Legrand or equivalent as approved by GE.
Supply and fixing in repair, connecting, testing and commissioning rupturing capacity, Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 400 Amps with breaking capacity 36 KA as per IEC60947-2 @ suitable size of sheet metal enclosure including all accessories all as specified and directed by Engineer-in Charge. make Schneider ,cat part No LV516343/Havells/L&T/Standard/Legrand or equivalent as approved by GE.
M & L for 3.15 mm CRCA MS Sheet with 02 (two) coat Machine spray paint over one coat red oxide primer/paint alongwith fixing arrangement through nut, bolts or welding etc suitable for panel base plate or panel canopy all as specified and directed by Engineer-in-Charge
M & L for PCC 1:3: 6 type C-2 with using 40 mm graded stone aggregate as in foundation of steel tubular pole with necessary form work complete all as specified and directed
Material and Labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for pole including necessary form work for fair finished exposed concrete surfaces complete all as specified and directed.
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed of following sizes :- (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles etc rates shall deemed to be included in the quoted rates). make- Havells/Gloster/Polycab
10 Sqmm, 4 core cable
35 Sqmm, 3½ core cable
50 Sqmm, 3½ core cable
95 Sqmm, 3½ core cable
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
Taking out old rusted unserviceable GI tubing of any size and S&F 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
Taking out old rusted unserviceable GI tubing of any size and S&F 50 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:-
Outdoor/indoor 25 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 70 to 120 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
M&L for spraying the chemical (Roundup) in sub station in the ration 1: 3 for buring the grass/removing the grass every three month as specified and directed by Engr-in-charge.
M & L for rubber matting chequered suitable upto 11 KV rating as per IS 15652-2006, (superseding IS 5424) of size 2Mx1Mx2.5mm thick all as specified by Engr-in-Charge.
Supply and fix 250 watt LED flood light, 5700 K, input voltage 240 volt, F=50 Hz, luminaire engergy saving, environmental friendly long life with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete as specified and directed Make- Wipro cat part No LF20-342-060-57-XX or equivalent approved by GE
Note : Total amount of Schedule of Credit for retrieved material mentioned on General summary of Tender documents in PDF format will be deducted offline during acceptance of Tender
MAHAJAN TRADING CO
ANIKET TRADERS
DAVINDER SINGH
slathia construction works
RANBIR ENTERPRISES
MOHAN LAL AND SONS
KARAN TRADERS
proach associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .