EXECUITVE ENGINEER ELECT. DIC PWD B AND R HISAR
EXECUITVE ENGINEER ELECT. DIC PWD B AND R HISAR
CONSTRUCTION OF NEW 3 BAYS BUS STAND AT JHOJHHU KALAN IN DISTT. CHARKHI DADRI (PDG. E.I. INTERNAL ONLY).
2021_HRY_165480_1
WD/Elect-GGN/Elect-HSR/100134
Open Tender
Electrical Works
Works
120 days
HISAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹1,860
24 Jun 2021
22 Mar 2021
31 Mar 2021
22 Mar 2021
30 Mar 2021
22 Mar 2021
60 days
Amount
a) Main Switches: Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. HSR 31.12 xiv) Triple pole switch with neutral link 32 amp. 415 Volts Cat-B.
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. HSR 31.13 ii) Size 40 mm x 40 mm x 6 mm.
M.S.Sheet . HSR 31.14: i) Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Blanking sheet . HSR 31.16 i) Supply and erection of blanking sheet in existing distribution board.
L) Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. HSR 31.17. a) Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
Supply and erection of Fittings and Accessories. HSR 31.18 vii) Call bell 220 / 230 volts A.C. Bakelite with double coil.
ix) Bell push flush type ( without flexible wire ) in existing sheet.
xi) Bakelite angle / straight button holder large size.
xii) Switch 5 amp. On existing sheet.
xiii) Wall socket 5 amp. On existing sheet.
xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
xxvi) Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
Erection and carriage of fans. HSR 31.20 v) Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
vi) Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Pipe Laying. (P) Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. HSR 31.21 xxi) Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed
xxii) Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
xxvii) Galvanized iron flexible pipe complete with socket nipples and check nuts etc. at both ends ( upto length of 1 meter.) b) Size 20 mm dia.
xxx) Supply and erection of PVC pipe of 6 kg. pressure laid 1 meter below ground level complete including digging refilling of the trench with jointing etc. c) PVC pipe 65 mm dia.
(Q) Earthing HSR 31.22: i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required
ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
xiv) Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
Miscellaneous . HSR 31.35 i) Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. b) 20 mm dia .
PVC Insulated wiring in recessed conduit. HSR 31.36 Wiring in 1.5 sqmm PVC insulated copper conduct cable in 1.6 mm thick conduit pipe i) Fan Point c) Long Point
ii) Light Point a) Short Point
b) Medium Point
c) Long Point
iii) Twin Control Light point with 2 way, 5 amp. Single pole switch. c) Long Point
vi) Call bell point including MS box of size 180mmx 60 mm deep for call bell. c) Long point
vii) 3 pin 5 amp. Plug point including earthing the 3rd pin etc. a) Short Point
c) Long point
viii) 3 pin 15 amp. Plug point with 4 amp. PVC insulated copper conductor cable including earthing the 3rd pin etc. c) Long point
S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. HSR 31.40 i) Cable size 1.5 sqm(3/0.81 mm)
ii) Cable size 2.5 sqm(3/1.05 mm)
iv) Cable size 6 sqm(7/1.05 mm)
S/E of double door sheet steel enclosure distribution board suitable for MCCb and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. HSR 31.41 i) 4-way, SP&N (Horizontal)
v) 4-way,TP&N (Horizontal)(8+12)
Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Deluxe model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. upto the entire satisfaction of the Engineer-in-Charge of the work. HSR 31.55
Non Schedule Item: S/E of 20/22 W indoor LED Tube fitting with batten and tube, decorative ultra slim liniare LED lighting fixture with extruded poly carbonate, environmental friendly, energy effiecent completed including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. (As per approved Make List of Department.
Non Schedule Item: S/E of 40 W indoor LED Tube fitting with batten and tube, decorative ultra slim liniare LED lighting fixture with extruded poly carbonate, environmental friendly, energy effiecent completed including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. (As per approved Make List of Department.
Non Schedule Item: S/E of AC ceiling fan of 48" (1200 mm) sweep double ball bearing with three nos. aluminium blades with standard acessories supplied by the manufactures of approved make without regulator complete in all respect.As per approved Make List of Department.
Non Schedule Item: S/E of exhaust fans of 12" (300 mm) approved make complete in all respect.As per approved Make List of Department.
M/S SHIV ELECTRICAL AND CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .