Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹2.8 Cr Quoted ₹3.7 Cr | L1 | Accepted-AOC Being Lowest Tender |
| 2 | L2₹3.8 Cr+₹10.6 L (2.90%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹3.8 Cr+₹10.6 L (2.90%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹3.8 Cr+₹17.3 L (4.73%)Rejected-Finance | ₹3.8 Cr+₹17.3 L (4.73%) | L3 | Rejected-Finance Higher than lowest tender |
| 4 | L4₹4.9 Cr+₹1.3 Cr (34.9%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹4.9 Cr+₹1.3 Cr (34.9%) | L4 | Rejected-Finance Higher than lowest tender |
| 5 | L5₹5.1 Cr+₹1.4 Cr (39.0%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹5.1 Cr+₹1.4 Cr (39.0%) | L5 | Rejected-Finance Higher than lowest tender |
Tender Value
₹8.5 Cr
EMD Value
₹7.5 L
Closing Date
13 Jul 2020, 6:00 pmClosed
HQ CE KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
PROVN OF LED-ISATION OF UNITS UNDER CE KOLKATA ZONE
2020_MES_348641_1
89020/E8
Open Tender
Civil Works
Works
270 days
Kolkata
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE (FW) Kolkata
₹7.5 L
Yes
3 Oct 2020
30 May 2020
14 Jul 2020
30 May 2020
13 Jul 2020
1 Jul 2020
Amount
SCHEDULE "A" (INTERNAL ELECTRIFICATION)
Taking down carefully serviceable or Unserviceable Fluorescent Tube light fittings, any type and any size fixed on walls/ceiling etc up to four feets in length and 36/40 watts, setting aside and transportation up to Contractors Store yard and making good the disturbed surfaces of wall/ceiling etc all as specified and directed at site.
Taking down carefully serviceable or Unserviceable Fluorescent Tube light fittings, any type and any size fixed on walls/ceiling etc up to two feets in length and 18/20 watts, setting aside and transportation up to Contractors Store yard and making good the disturbed surfaces of wall/ceiling etc all as specified and directed at site.
Taking down carefully serviceable or Unserviceable Building Security Lights, any type and any size up to 400 watts, setting aside and transportation up to Contractors Store yard and making good the disturbed surfaces all as specified and directed at site.
Taking down carefully serviceable or Unserviceable CFL/Incandescent lamps, any type and any size up to any watts, setting aside and transportation up to Contractors Store yard.
Taking down carefully serviceable or Unserviceable recess mounted 2'X2' fittings any type, up to any watts, setting aside and transportation up to Contractors Store yard. and making good the disturbed surfaces all as specified and directed at site
Taking down carefully serviceable or Unserviceable surface mounted 2'X2' fittings any type, up to any watts, setting aside and transportation up to Contractors Store yard. and making good the disturbed surfaces all as specified and directed at site Note For Item No 01 to 06 Above:- Retrieved material in serviceable or Unserviceable condition shall become contractors property on "As is where is basis" and suitable credit shall be deducted on this account. Both serviceable and Unserviceable items shall be property of the Contractor and shall be removed from site after deduction of Credit amount for both Serviceable and Unserviceable fittings, as per Schedule of Credit.
Supply and fix surface & wall mounted LED batten 4 feets with 1x20 w indoor decorative luminaries with and including Electronic driver and 1 x20 Watt LED lamp, pre-wired including necessary electric connection copper flexible PVC cable of 0.50 sq. mm three core not more than one metre in length from ceiling rose/connector to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 20 W/Total system lumen not less than 2400 Lumens,Voltage Range: 140 to 270 Volts, Continuous operation of 2 Hours at 320 Volts. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - Minimum IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy of Luminaire (lumens/Watt): - Not less than 120 lumens/watt (ix) Colour temperature: - Not less than 5700 degree K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2.5 KV (xv) Heat sink: - As per OEM's design.
Supply and fix surface & wall mounted LED batten 2 feets with 1x10 w indoor decorative luminaries with and including Electronic driver and 1 x10 Watt LED lamp, pre-wired including necessary electric connection with copper flexible PVC cable of 0.50 sq. mm three core not more than one metre in length from ceiling rose/connector to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1200 Lumens,Voltage Range: 140 to 270 Volts, Continuous operation of 2 Hours at 320 Volts. (ii) Housing: - Aluminium Extruded body.(iii) IP rating: -Minimum IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy of Luminaire (lumens/Watt): - Not less than 120 lumens/watt (ix) Colour temperature: - Not less than 5700 degree K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
Supply & Fixing pressure die cast aluminium housing LED Building security light luminaries 20 watt LED with electronic driver and LED lamp and 50 mm dia light grade GI pipe bent to shape of 45" 1.5 long and fixing arrangement meeting the following specifications:- (i) System watt/Lumens: - Max-20 watts/total system lumen not less than 2400 Lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - Minimum IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lumens/watt. (ix) Colour temperature (K): - Not less than 5700 Degree K (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Material & Labour for LED Bulb 18 W, AC 230V, 50 Hz pin type complete with following specifications. (i) System Watts/lumens: - Max 18 W/Total system lumen not less than 2160 Lumens. (ii) Housing: - Extruded polycarbonate (iii) IP rating: -Minimum IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
Material & Labour for LED Bulb 12 W, AC 230V, 50 Hz pin type complete with following specifications. (i) System Watts/lumens: - Max 12 W/Total system lumen not less than 1440 Lumens. (ii) Housing: - Extruded polycarbonate (iii) IP rating: -Minimum IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
Material & Labour for LED Bulb 09 W, AC 230V, 50 Hz pin type complete with following specifications. (i) System Watts/lumens: - Max 9 W/Total system lumen not less than 1080 Lumens. (ii) Housing: - Extruded polycarbonate (iii) IP rating: -Minimum IP 20 (iv) Front cover: - Acrylic/ polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
Supply & Fix LED Recess mounting 2X2 LED 35 Watt luminiaire,Glare free uniform illumination with longer life and less maintenance complete all as specified and as directed and meeting following specifications:- (i) System Watts/lumens: - Max 35 W/Total system lumen not less than 4200 Lumens. (ii) Housing: - Extruded polycarbonate or extruded Aluminium (iii) IP rating: - Minimum IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for ceiling recess mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
Supply & Fixing LED Surface mounting 2X2 LED 35 Watt luminiaire, Glare free uniform illumination with longer life and less maintenance complete all as specified and as directed and meeting following specifications:- (i) System Watts/lumens: - Max 35 W/Total system lumen not less than 4200 Lumens. (ii) Housing: - Extruded polycarbonate or Extruded Aluminium (iii) IP rating: - Minimum IP 20 (iv) Front cover: - Acrylic/ polycarbonate cover (v) Mounting: - Suitable for surface mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
(EXTERNAL ELECTRIFICATION)
Taking down carefully serviceable or Unserviceable Street light fittings, any type and any size any wattage fixed on Steel tubular or PCC poles, setting aside and transportation up to Contractors Store yard and making good the disturbed surfaces all as specified and directed at site.
Taking down carefully serviceable or Unserviceable Flood light fittings, any type and any size, any wattage fixed on High Mast lighting systems, setting aside and transportation up to Contractors Store yard and making good the disturbed surfaces all as specified and directed at site.
Taking down carefully serviceable or Unserviceable High bay light fittings, any type and any size, any wattage fixed on roof girders Ceiling etc, setting aside and transportation up to Contractors Store yard and making good the disturbed surfaces all as specified and directed at site
Taking down carefully serviceable or Unserviceable Bollard Type/Post Top lantern fittings etc , any type and any size, any wattage fixed on roof girders Ceiling etc, setting aside and transportation up to Contractors Store yard and making good the disturbed surfaces all as specified and directed at site. Note For Item No. 2.01 to 2.04 Retrieved material in serviceable or Unserviceable condition shall become contractors property on "As is where is basis" and suitable credit shall be deducted on this account. Both serviceable and Unserviceable items shall be property of the Contractor and shall be removed from site after deduction of Credit amount for both Serviceable and Unserviceable fittings, as per Schedule of Credit.
Supply and Fixing LED street light fittings on poles all as conforming to the following parameters: - (i) System watt/Lumens: - Max-45 watts/total system lumen not less than 5400 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - Minimum IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED street light fittings on poles all as conforming to the following parameters: - (i) System watt/Lumens: - Max-60 watts/total system lumen not less than 7200 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - Minimum IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED street light fittings on poles all as conforming to the following parameters: - (i) System watt/Lumens: - Max- 72 watts/total system lumen not less than 8640 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - Minimum IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED street light fittings on poles all as conforming to the following parameters:- (i) System watt/Lumens: - Max- 90 watts/total system lumen not less than 10800 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - Minimum IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED street light fittings on poles all as conforming to the following parameters:- (i) System watt/Lumens: - Max- 150 watts/total system lumen not less than 18000 lumens(ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - Minimum IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED flood light fittings on poles/as directed workshops, sheds and play ground /High mast lighting systems etc all as conforming to the following parameters: - (i) System watt/Lumens: - Max- 50 watts/total system lumen not less than 6000 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - Minimum IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50mm dia, or bracket mounting (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED flood light fittings on poles/as directed workshops, sheds and play ground /High mast lighting systems etc all as conforming to the following parameters: - (i) System watt/Lumens: - Max- 80 watts/total system lumen not less than 9600 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, or bracket mounting (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 74 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED flood light fittings on poles/as directed workshops, sheds and play ground /High mast lighting systems etc all as conforming to the following parameters: - (i) System watt/Lumens: - Max- 100 watts/total system lumen not less than 12000 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, or bracket mounting (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED flood light fittings on poles/as directed workshops, sheds and play ground/ high mast lighting systems etc all as conforming to the following parameters: - (i) System watt/Lumens: - Max-120 watts/total system lumen not less than 14400 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, or bracket mounting. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design.
Supply and Fixing LED flood light fittings on poles/as directed workshops, sheds and play ground/ high mast lighting systems etc all as conforming to the following parameters: - (i) System watt/Lumens: - Max-150 watts/total system lumen not less than 18000 lumens (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 65 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm dia, or bracket mounting. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design. Note for Flood Light Fittings (Item No. 2.10 to 2.14 above): Provision of Flat Iron mild steel clamp of minimum size 40mm X 5 mm for fixing of fittings shall be deemed to be included in the unit rate quoted. Wire for connection of luminaires shall be measured and paid for separately.
M&L for Energy saving, environment friendly and robust open type vertical Highbay LED luminaire with High power COB LED as light source, 110W with the following specifications:- (i) System Watts/lumens: - Max 110 W/Total system lumen not less than 13200 Lm. (ii) Housing: - Extruded polycarbonate/metal with heat sink (iii) IP rating: - IP 20 (iv) Front cover: - No cover but with reflector. (v) Mounting: - Suitable for wall/ceiling mounting with necessary hanging arrangement. (vi) Finish: - Smooth finish (vii) Lamp: - High bright COB LED (viii) System Efficacy (lm/Watt): - Not less than 110 lm/watt (ix) Colour temperature: - Not less than 6500 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Reflector: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
Supply and fix Bollard light fittings LED type of 10 Watt with luminous efficacy of minimum 110 lumens per watt, IP 65, CCT 5000 K, tripod style inverted pyramid shape with soft 360 degrees light distribution , minimum 800 mm in height and 110 mm in dia at top with extruded aluminium and die cast aluminium LM6, powder coated in graphite grey and white texture finish and frosted acrylic diffuser. grouted with three numbers of M8 Screws,complete all as specified and directed.
Supply and fix Bollard light fittings LED type of 20 Watt with luminous efficacy of minimum 110 lumens per watt, IP 65, CCT 5000 K, tripod style inverted pyramid shape with soft 360 degrees light distribution , minimum 800 mm in height and 110 mm in dia at top with extruded aluminium and die cast aluminium LM6, powder coated in graphite grey and white texture finish and frosted acrylic diffuser. grouted with three numbers of M8 Screws ,complete all as specified and directed.
Supply and fixing GI tubing 50 mm bore (light grade) in trenches/floor/fixed along pole for cable/earth strip protection with proper size of clamp, nuts and bolts or for fixing lightening conductors etc all as specified and as directed by Engineer-in-Charge. (For post top)
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge. (for foundation of post top and bollard).
S&F PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs as in repair complete all as specified and as directed by the Engr-in-Charge.
M&L for earthing complete with galvanized steel plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.50 m below ground level connected to Galvanized Iron wire 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including excavation and earth work and disposal of surplus soil including 15 mm GI tubing medium grade and necessary fitting for protection of GI wire including laying of charcoal dust and common salt PCC (1:2:3) type C-1 using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 12mm dia, plastering 15mm thick CM (1:6) internally and up to 150mm below ground level externally, PGI funnel with 20mm dia GI pipe light grade for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009 ) and connected to earth test including testing complete all as specified and directed.
S&F in repair Bracket/Arm suitable for street light fittings, made out of 40mm bore(light grade) GI pipe length not exceeding 1.5metre long, fixed with 02 sets of flat iron clamp of size 40mm X 5mm, with bolts,nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer including taking down existing racket complete all as specified and directed
Prasur Electricals & Engineering Co.
KB PROJECTS
BHARAT MULTITECH INDUSTRIES PVT LTD
Phoenix Infra
TRIVENI CONSTRUCTIONS
M/S DEEKSHA ENTERPRISES
DNS CONSTRUCTION COMPANY
surendra infrastructure pvt ltd
NARSINGH ENGINEERING COMPANY
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED
Ktech Engineer Builders Co. Pvt. Ltd
M P KHAITAN
BHOWMICK ENTERPRISES INDIA
M/s KASHMIRA SINGH BARMI AND SONS
MAA BHAGWATI ASSOCIATES
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .