Executive Engineer S and D Division Ist
Suliman Complex Dalgate Srinagar
upgradation of SCADA system for synchronized operation of all electromechanical equipments along with requisite license software both engineering and operating license for 6 MLD STP alluchibagh 2.21 MLD STP Rajbagh
2026_HAUDD_311912_1
e-NIT No.13 of 2026-27
Open Tender
Machineries/ Mechanical Engg Items
Percentage
90 days
Alluchi-Bagh and Rajbagh
as per NIT
2 documents required · 2 mandatory
₹2,100
Executive Engineer S and D Division Ist
₹80,000
18 Aug 2026
9 Jun 2026
11 Jul 2026
9 Jun 2026
10 Jul 2026
9 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, installation, testing and commissioning of following :-
1. Ultrasonic Level Transmitter of Range 0-10 Mtr for Main Sump also to be integrated with Existing SCADA as per the plant operational requirement. LU 240 (02 nos) Make (Siemens/Allen Bredley/Equivalent)
2. Hydrostatic Level Transmitter of Range 0-10 Mtr for anoxic chambers also to be integrated with Existing SCADA as per the plant operational requirement.(02 nos ) Make (Siemens/Allen Bredley/Equivalent)
3. DO Sensor Of Range 0-10 MG/L Mtr for Anoxic chambers with controller & Display with sensors and is to be integrated with Existing SCADA as per the plant operational requirement.(02 nos) Make (Siemens/Allen Bredley/Equivalent)
4. Chlorine Leak Detector Sensor for leak detection with Leak Alarm system to be displayed in SCADA and to be integrated with Existing SCADA as per the plant operational requirement (01 nos) Make (Honeywell / Reputed) 5. Butterfly valve for anoxic chamber along with their Feedbacks like open, close feedback to be displayed in SCADA and also to be integrated with Existing SCADA as per the plant operational requirement .The valve should be capable of manual operation to bring the system fail safe (0-1 Bar ) pressure to be sustained by valve.(02 nos)...Contd as per Annexure A. | 2 | Job | 20,00,000 | ₹40,00,000 |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.23 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.51 MB
BOQ_1009799.xls
BOQ • 0.29 MB
AnnexureA.pdf
Other Document • 0.46 MB
DOE-II-NIT-13.pdf
PDF • 0.36 MB
DoE-NIT-13-14-2026.pdf
PDF • 0.27 MB
Corrigendumnit-8-10-13-14.pdf
PDF • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .