Tender Value
₹15.9 L
EMD Value
₹31,874
Closing Date
4 Feb 2022, 3:00 pmClosed
Executive Engineer (E)
O/o EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park, Delhi-92
RMO E and M Services installed at UTCS Bldg. Vishwas Nagar, Shahdara, Delhi. (SH- Repairing/ replacement of High Mast/ Flood light fittings, pumps, starter and other electrical accessories.)
2021_PWD_213652_2
70/EE (E)/PWD NE and Shah. Elect. Divn./2021-22
Open Tender
Electrical Works
Item Rate
60 days
UTCS Building
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹31,874
15 Feb 2022
28 Jan 2022
4 Feb 2022
28 Jan 2022
4 Feb 2022
28 Jan 2022
Amount
Replacement of defective/worn-out Flood light fitting by Supplying, Installation Testing and Commissioning of 150-watt LED Flood Light fitting aluminium die cast housing, IP 66 with high power LED as light source, system lumen efficiency of ≥ 130 lm/W, colour rendering (CRI) ≥ 70, and correlated colour temperature (CCT) of 5500 - 6500 (±300K). The luminaries should have 10KV surge protection, PF≥0.95, the total harmonic distortion≤ 10% operatable in voltage range of 120-270 V, total burning hours 50000 with LM 70/79/80 Certificates The driver used must be a constant current driver with efficiency of ≥ 85% and driving current ≤ 725mA complete r on surface with suitable fasteners as required and as per direction of Engineer-In charge. i/c dismantling of existing fittings. The manufacturer should provide LM 80 reports along with warrantee of 5 years for luminaires i/c drivers etc. as required.
Replacement of defective/worn-out Flood/ high mast light fitting by Supplying, Installation Testing and Commissioning of 250 watt LED High Mast/ Flood Light fitting aluminium die cast housing, IP 66 with high power LED as light source, system lumen efficiency of ≥ 130 lm/W, colour rendering (CRI) ≥ 70, and correlated colour temperature (CCT) of 5500 - 6500 (±300K). The luminaries should have 10KV surge protection, PF≥0.95, the total harmonic distortion≤ 10% operatable in voltage range of 120-270 V, total burning hours 50000 with LM 70/79/80 Certificates The driver used must be a constant current driver with efficiency of ≥ 85% and driving current ≤ 725mA complete r on surface with suitable fasteners as required and as per direction of Engineer-In charge. i/c dismantling of existing fittings. The manufacturer should provide LM 80 reports along with warrantee of 5 years for luminaires i/c drivers etc. as required.
Replacement of defective/ burnt-out fittings by Supplying, Installation Testing and Commissioning of LED Post Top fittings of range 40 watt round spigot shaped with 40-watt LED lamp suitable for use on single phase AC supply 50 Hz having pressure dia cast housing with IP- 65 protection including dismantling of old fittings, connection with 2.5 sq. mm. FRSL copper wire, testing and commissioning etc. complete as required.
Providing and fixing pole box of size 250mm X 200mm X 105mm (product code GSJB2520) with side openable hinged cover complete with two strip aluminium bus-bar of 100 amps capacity mounted on DMC bus support and 1 no. of SPMCB of 6 amps 'C' series capacity with din rail on the existing street light pole with the help of two nos. MS clamps of suitable size, including making hole to insert the cable and dismantling the worn out MS box etc. complete as required.
Supplying, installation, testing and commissioning of new 36 to 40 watt recessed mounted LED Luminaries of size 300 mm (Length) x 1200 mm (Width) housing made with white powder coated CRCA sheet metal and polycarbonate diffuser suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency not less than 120 luman per watt. and colour temperature of 6000 K, CRI >80 with driver having power factor > 0.90, THD < 20% and efficiency > 85% driver should be IC Complete, with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of 4 nos. fastener Hook, Clutch wire and sleeve i/c testing, commissioning etc. complete as required.
Supplying, Installation, Testing and Commissioning of 36 to 40-watt surface/ recessed mounted LED Luminaries of size 600 mm (Length) x 600 mm (Width) housing made with white powder coated CRCA sheet metal and polycarbonate diffuser suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency not less than 120 luman per watt. and colour temperature of 6000 K, CRI >80 with driver having power factor > 0.90, THD < 20% and efficiency > 85% driver should be IC Complete, with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of 4 nos. fastener Hook, Clutch wire and sleeve i/c testing, commissioning etc. complete as required.
Replacement of defective/worn-out fl. fittings with new 20 to 22 watt 300 mm. x 300 mm. square surface mounted LED flat panel suitable for operation on 150 to 265V single phase A.C. supply i/c connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 100 luman per watt. and colour temperature of 6000 K, CRI >80 i/c dismantling of existing old fitting if any etc. Complete as required.
Supplying, Installation, Testing & Commissioning 18 to 20 watt 1200 mm long high efficiency LED linear batten Luminaries having aluminium extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 120 luman per watt and colour temperature of 6000 K, CRI >80 including connect ion with 1 5 sq. mm PVC insulated copper conductor FRLS cable i/c dismantling of existing old fitting if any etc. complete as required.
Supplying, Installation, Testing & Commissioning of LED downlighter round type surface mounted with following technical specification: - i). System Lumen output >1800 ii). System Efficiency >100 lm/Watt iii). Input Power not more than 18 W iv). CCT >5700, CRI> 70, PF > 0.95, THD< 10% v). Life 50 K hours @ L70
Supplying and replacement of existing damaged fitting into 5 watt to 8 watt LED fancy/ decorative wall light without a glare soft indirect lighting with holder & LED lamps including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable etc. complete as required. (Appropriate model is approved by Engineer-in-Charge.)
Supplying, Installation, Testing and Commissioning of 1200 mm sweep ceiling fan, made out of aluminium housing and aluminium blades ISI marked including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing M.S flat Fan hook if required etc. complete as required.
Supplying and fixing of 400 mm. sweep wall fan oscillation type suitable of operation on single phase 230 volts 50 Hz. on existing wall/ surface i/c connection with 1.5 sq. mm. FRLS PVC insulated copper conductor cable etc. complete as required.
Replacement of worn-out fresh air fan with new 250 mm. sweep plastic body fresh air fan suitable for operation on 220 volts 50 Hz. in the existing hole, connection with 1.5 sq. mm. FRLS PVC insulated copper conductor cable etc. i/c buy back of existing burnt-out fresh air fan etc. complete as required.
Supplying and Fixing 300 mm dia 900 RPM heavy duty exhaust fan suitable for operation on 230 volt, ±10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC insulated PCV sheathed copper conductor single core cable i/c testing etc. as reqd.
Supplying & Laying of one Number 3x10 sq. mm. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with amendment No. 1 in following manners.
In Loose & Connection/Open duct
On surface
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. (a) Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE Aluminium Conductor armoured power cable of 1.1 KV grade as reqd.
3 X 10 sq. mm (22mm)
3½ X 50 sq. mm (35 mm)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell push
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
250 A, 35 kA, TPMCCB
150 A, 16 kA, TPMCCB
100 A, 16 kA, TPMCCB
Lifting charges of 10 HP Open well mono submersible pump set from the existing underground tank with the help of chain pully & tripod set i/c opening of pipe line etc. complete as required.
Replacement of defective Pump set by Supplying, Installation Testing and Commissioning of 10 HP open-well, mono submersible pump set having 100 mm. suction & 100 mm. delivery pipe line capable to deliver 2050 LPM at the head of 89 mtr. suitable for operation on 440v three phase 50 Hz Ac supply i/c lowering the pump set in the existing sump-well and lifting of old pump i/c dismantling and making good the same, connection, making water proof joint etc. complete as required i/c dismantle pump buy back.
Replacement of defective/ burnt starter by Supplying, Installation Testing and Commissioning of fully automatic star delta starter panel having Amp. meter, voltmeter, TPN MCB having relay range 13.2-20.0 Amps. suitable for 10 HP open well pump set with contactor & timer in sheet steel enclosure on existing wall with the help of hold fastener i/c connection testing etc. as required i/c dismantle pump buy back.
Rewinding of three phase 10 HP open well mono submersible pump set i/c replacement of Gun Metal Bearing Bush, Thrust Plate, Thrust Bearing Bush, Impellor remaining turning, Motor Seal, Impellor, Impellor, Gas Kit Set, packing & nut bolts etc. i/c lowering and lifting of pump, connection, testing etc. complete as required.
Repairing of defective Fully Automatic Star Delta pump starter suitable for 10 HP open well submersible pump set and replacement of all defective parts like single-phase preventer, TP contactor, Over Voltage Relay, ammeter/ voltmeter etc. i/c dismantling & refixing of starter, connection, testing etc. complete as required.
S/I/T/C of submersible pumping set for drinking water supply having stainless steel impeller, dynamically balanced stainless-steel shaft with non-return valve of suitable 5 HP 9 stage submersible pump set with non-aging water proof insulation to run on 3 phases 415-volt 50 Hz. A.C. supply capable of delivering 600 lpm at 23 mtr. with minimum operating head range from 23 mtr. to 59 mtr. complete with standard length of copper submersible cable of suitable size i/c lowering of all the length of coloum / delivery pipe with water proof jointing of cables complete etc. as required at site.
Lifting charges of 5 HP Open well pump set from the existing bore-well with the help of chain pully & tripod set i/c opening of pipe line etc. complete as required.
Supplying, Installation, Testing and Commissioning of fully automatic star delta starter suitable for 5 HP submersible pump, 3 phase power supply in sheet steel enclosure having safety devices i.e. single-phase preventer, TP contactor, Over Voltage Relay, ammeter/ voltmeter etc. in existing panel/ wall with the help of dish fastener i/c connection testing etc as required.
Less of Account of buy back of following dismantled material
Assorted PVC insulated copper wire
Assorted size MCB DB with accessories
Assorted light fittings
10 HP Pump Set
5 HP Pump Set
Pump Starter
Ceiling Fan
Wall Fan
Exhaust Fan
Flood light fitting/ Post top fittings
Assorted Material like Conduit, Switches, Sockets, Sheet, Box, DP Sheet enclosure etc.
A K Enterprises
A K Electric Works
Shri Bankey Bihari Electricals
SM ELECTROTECH PRIVATE LIMITED
Krishna Electreical Works
Uday Raj Pandey
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .