| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹20.8 L+₹1.1 L (5.36%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹22.1 L+₹2.4 L (12.2%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹34.8 L+₹15.1 L (76.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
31 Jan 2020, 6:00 pmClosed
GE SOUTH PATHNAKOT
GE SOUTH PATHANKOT
Repair/maint of perimeter lights ,street lights, security lights, post top lanterns etc including control panel and illumination system including OH line/UG cable alongwith allied works at OTG, Bhadouriya Complex and 167 MH area under GE (S) PKT
2020_MES_311756_1
GES/PKT/T-52/2019-20
Open Tender
Civil Works
Item Rate
180 days
BHADOURIYA COMPLEX AND 167 MH Pathankot
Repair/maint of perimeter lights ,street lights, security lights, post top lanterns etc including control panel and illumination system including OH line/UG cable alongwith allied works at OTG, Bhadouriya Complex and 167 MH area under GE (S) PKT
9 documents required · 9 mandatory
₹500
Yes
GE SOUTH PATHANKOT
₹52,000
Yes
9 May 2020
4 Jan 2020
1 Feb 2020
4 Jan 2020
31 Jan 2020
17 Jan 2020
4 Jan 2020 - 12 Jan 2020
Amount
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in any type of soil all as directed.
All as per srl item No 1 above but exceeding depth 1.5 mtr and n exceeding 3 mtrs
Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed..
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed. .
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc suitable fittings for cable protection complete all as specified and directed.
M&L for GI pipe light grade 100 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as specified and directed.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes including dismantling old unserviceable UG cable complete all as specified and directed. Note: (i) Earth work ( Excavation, Returning & refilling and removal) , sand cushining , PCC protection cove, GI protection pipe shall be measured and paid for separately under respective item of Sch 'A'.
16 Sqmm 2 core complete all as specified and directed.
16 Sqmm 4 core complete all as specified and directed.
25 Sqmm 4 core complete all as specified and directed.
3.5 core 35 Sqmm complete all as specified and directed.
3.5 core 50 Sqmm complete all as specified and directed.
3.5 core 70 Sqmm complete all as specified and directed.
3.5 core 95 Sqmm complete all as specified and directed.
3.5 core 120 Sqmm complete all as specified and directed.
3.5 core 150 Sqmm complete all as specified and directed.
3.5 core 185 Sqmm complete all as specified and directed.
3.5 core 240 Sqmm complete all as specified and directed.
M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 50 sqmm complete all as specified and directed.
All as per srl Item No 26 above but for cable of size 3.5 core 70 to 150 sqmm complete all as specified and directed.
All as per srl item No 26 above but for cable of size 3.5 core 185 to 400 sqmm complete all as specified and directed.
All as per srl Item No 29 above but capacity 30 KVAR with incoming MCCB of capacity 63 Amps 4 pole (6x5) complete all as specified and directed.
All as per srl Item No 29 above but capacity 40 KVAR with incoming MCCB of capacity 80 Amps 4 pole (8x5) complete all as specified and directed.
All as per srl Item No 29 above but capacity 50 KVAR with incoming MCCB of capacity 80 Amps 4 pole (10x5) complete all as specified and directed.
S & F in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as directed .
(a) 320-400 Amps, 3P, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, 415V MCCB, 35KA rating complete all as specified and directed.
(b) 200-250 Amps, 3P,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, 415 V MCCB, 25KA rating complete all as specified and directed.
(c) 160-200Amps, 3P,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, 415 V MCCB, 25KA rating complete all as specified and directed.
(d) 125-160Amps, 3P,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, 415 V MCCB, 25KA rating complete all as specified and directed.
(e) 32 to 80 Amps, 3P, 415 V MCCB, 16KA rating (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified and directed.
(f) 4 Pole MCCB, 415 V, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% with breaking capacity 50 KA, 500- 630 A rated complete all as specified and directed.
(g) 4 Pole MCCB, 415 V, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% with breaking capacity 35 KA, 320-400 A rated complete all as specified and directed.
(h) 4 Pole MCCB, 415 V, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% with breaking capacity 25 KA, 200-250 A rated complete all as specified and directed.
(j) 4 Pole MCCB, 415 V, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% with breaking capacity 25 KA, 160-200 A rated complete all as specified and directed.
(k) 4 Pole MCCB, 415 V, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% with breaking capacity 25 KA, 125A to 160 A rated complete all as specified and directed.
Dismantling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made oudoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet, floor mounted, with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 400 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB with (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% of 4 pole 415 volts 3 phase 250 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
Dismantling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made oudoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet, floor mounted, with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB with (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% of 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
M & L for replacement of unsv/broken thermoplastic polycarbonate spring type locks suitable for panel locking (Mi DV 01 with Mi SR 4) complete.
Dismantling old unserviceable poles and Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-55 (11.00 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Sch 'A'.
Dismantling old unserviceable poles and Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (9.00 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Sch 'A'
Material and Labour for Galvanised iron round bracket made out of 40mm dia GI tubing including making provision for fixing of 04/06 no flood light on 11 mtr steel tubular pole ad fixing and connecting up of LED lights (LED lights shall be measured seperately under respective items of sch ) complete all as specified and directed. Note: The inner diameter of ring shall not be less than 1.0 meter
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete all as specified and directed.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work complete all as specified and directed.
Restretching of ACSR conductor of any size of over head lines LT/HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: ACSR conductor Required for winding etc to be included in quoted rates complete all as specified and directed.
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 150 to185 sqmm complete all as specified and directed.
Cutting, trimming of hanging/ extended braches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorised diesel operated hacksaw etc complete. One span comprises of 3 to 5 conductors of any distance between one pole to adjacent pole including trimming of all tree branches in vicinty & around poles /conductor & will be measured as one span. Necessary prior permission shall be obtained from concerned I/C JE E/M before carrying out the work. All safety measures & insurance to the staff undertaking the Job shall be the Contractor's responsibility complete all as specified and directed.
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2300 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 25 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2800 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 30 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4200 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6800 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 11000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete all as specified and directed.
Taking down old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 9500 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 100 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable street light fittings from any height and Supply & Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 8500 lumens suitable wattage for efficiency not less than 95 lumens/Watt,min wattage 90 watt, with ingress protection IP 65 and SPD of capacity 10 KV etc complete and testing on completion all as specified and as directed. Note: The GI pipe if rquired bracket will be measured and paid separately under relevant schedule items
Note for item No 56 to 66 : (i) Driver Efficacy – more than 85% ( constrant current driver).(ii)Driver Type – Potted (iii) THD - < 10% (iv)Led Driver Current – less than 750 mA(v) Efficacy of Led Fixtrue – 100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 5KV (vii) Working Humidity - 10% to 90% RH (ix) Led Make – Nichia/Philips Lumiled/ Cree /Osram/ Seoul (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Cast with company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from Third Party ( instead of company in house lab) NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut bolts and GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
S & F in repair CFL roadway security light fitting apoxy black powder coated sheet aluminium housing, CRCA sheet steel gear tray, clear acrylic cover and accessories including CFL lamp of wattage 1x18 watt including GI pipe bracket complete all as specified and as directed.
S & F timelite distribution boards (street light DBs) 63 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one .
S & F in replacement of old u/s service cable size 4 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as specified and directed.
All as per srl item No 70 abovebut for service cable of size 6 sqmm complete all as specified and directed.
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one complete all as specified and directed.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective complete all as specified and directed.
M&L for bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective complete all as specified and directed..
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as specified and directed. Note:a) The M/L for Items like ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately. (e) The Contractor shall depute manpower for attending/rectifying the defects/complaints on daily basis for each area/complex separately. Recovery for non rectification of complaints within 2 days time period after receiving complaints shall be at the rate of Rs 500/- per each complaint.
Supply only the following spares suitable for LED street/Flood light fittings.
Potted type IP65 electronic driver suitable for 90 to 120 W LED light fitting complete all as specified and directed.
Potted type IP65 electronic driver suitable for 70 to 80 W LED light fitting complete all as specified and directed.
Potted type IP65 electronic driver suitable for 30 to 60 W LED light fitting complete all as specified and directed.
Surge protection device of capacity 10 KV suitable for LED light fitting complete all as specified and directed.
Supply only the following spares suitable for street/Flood light fittings complete all as specified and directed.
Lamp Holder suitable for 30 to 50 Watt High power LED complete all as specified and directed.
LED Lamp 40 Watt with 4000 lumens output, PF >0.9 complete all as specified and directed.
S & F in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels complete all as specified and directed.
M&L for preparation of old painted surfaces of 9 m long PCC poles incl removing oil/greasy spots and applying one coat of synthetic enamel paint of black and yellow in alternate strips of 30 cm width upto 1.5 mtr height including applying a coat of white wash on pole coping and lettering the pole details with with white letters/ blackground etc complete all as specified and directed.
S & F in repair 3 pole power contactor with coil voltage 230 Volt or 415 V AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as specified and directed.
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and GI wire 8 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 4 mm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
Dismantling LED light fitting of any make capacity 90 to120 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and directed. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items.
Dismantling LED light fitting of any make capacity 70 to 80 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and directed. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items.
Dismantling LED light fitting of any makecapacity 40 to 60 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and directed. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of of any make of capacity 25 to 36 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and directed. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole complete all as specified and directed.
Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint complete all as specified and directed.
Dismantling of ACSR conductor of any size, from insulator etc from the structure/over head line complete all as specified and directed.
M&L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and binding with new binding wires to insulators complete all as specified and directed.
Dismantling insulators any type, size complete all as specified and directed.
M/L for stringing of HT/LT Over head line ( ACSR) of any size of overhead line complete including binding with ACSR conductor near pitted conductor complete all as specified and directed.
M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
Material & labour for fixing in repairs Stay assembly complete with accessories such as MS stay plate of size 300mmx300mmx6mm thick, stay rod 20mm dia, stay bow, nuts, bolts and check nuts of GI including GI stay strand of size 7/4 mm all as shown in electrical plate No. 1 of SSR Part-I of 2009 or complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), PCC, stay clamp and loop type insulators will be measured and paid separately under relevant schedule items).
Dismantling old rusted defective LT panel and Supply, installing, testing and commissioning of LT feeder pillar box factory made oudoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 40 x 40 x 6mm ,45 cm height, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchears/MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect for main Panel for Transformer and including provn of the following:- Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
i) Aluminium Bus bar 400 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation complete all as specified and directed.
ii) MCCB 4 pole 415 V 3 phase 250 Amp, 36 KA (Thermal magnetic release) Ics=100%Icu - 01 Nos (incoming) complete all as specified and directed.
ii) MCCB 3 pole 415 V 3 phase 160 Amp, 36 KA (Thermal magnetic release) Ics=100%Icu - 02 Nos (outgoing) complete all as specified and directed.
vii) Digital Amp meter of size 96x96mm rating 0-100 Amp with CT's & slection switch - 01 Nos complete all as specified and directed.
viii) RYB LED indicator- one set complete all as specified and directed.
Sch of Credit = 92135.00
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
SATISH AND CO
commercial traders
M/S BALWINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .