| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹19.4 L+₹51,850.50 (2.74%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹20.2 L+₹1.3 L (7.13%)Rejected-Finance HOUSE NO 11 VILLAGE POST SAIGAON THE BHALKI DIST BIDAR STATE KARNATAKA 585416 | BIDAR | KARNATAKA | 585416 | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹21.4 L+₹2.5 L (13.2%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L4 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
28 Feb 2023, 6:00 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
ADDN / ALTN AND SPECIAL REPAIRS TO EXTERNAL WALL SURFACES OF BLDG NO P-195 AT INS SHIVAJI LONAVLA
2023_MES_579494_1
GE/LONAVLA/8135/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹48,000
Yes
12 Oct 2023
7 Feb 2023
2 Mar 2023
7 Feb 2023
28 Feb 2023
15 Feb 2023
7 Feb 2023 - 14 Feb 2023
Amount
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Demolition of Concrete Jali/ Louver of any description and in any position not otherwise specifically provided for toilet shafts/ ducts
M&L rendering in CM (1:4) 15mm thick cement plaster as in backing coat brick/concrete surface with necessary adhesives finished rough to receive wall claddings/ cladding tiles
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius in CM 1:4
M&L for External Wall tiles area of tiles n exc 0.20 Sqm each (With a tolerance of +- 4% in thickness) fixed with blended powder polymer modified cement based stone tile adhesives of thickness of approx 3-6 mm thick combed with notched trowel and placed and topped properly to ensure complete coverage of backside of tiles over adhesives including cleaning/ preparation of newely plastered surfaces to be tiled and making it free from wax, grease, polish,paints etc all as per manufacturers instructions Note :strictly apply the adhesive paste which can be tiled withing 10-15 minutes (Makes: Somany External wall tiles/Johnson tiles. Roff Stone tile adhesives/Dr. Fixit Fevimate TL tile fixing adhesive Note : Item is required to be carried out at height upto 15 m above GL. Rate deemed to include for all necessary scaffolding and protective measures to work at height up to 15 M from GL
M&L preparation of new plastered surfaces/ complete removal of existing treatment on old plastered wall including removing fungus/ algae dirt, oil, grease and loose particles by wire brush, cleaning, washing and removing dust and cracks more than 5mm shall be sealed with "Pidilite URP" manufactured by DR Fixit or with "Plaster seal" manufactured by STP and cracks more than 2mm and less than 5mm shall be sealed with " crack X powder" manufactured by Dr.Fixit or "Plaster seal" manufactured by STP and applying primer and two coats of water proof decorative elastomeric coating of approved shade/colour complete all as specified and as directed. Note :- (i) Primer shall be "Prime seal" manufactured by DR Fixit or "Plaster seal" manufactured by STP. (ii) Water proofing decorative elastomeric coat shall be Rain coat DFT 100 manufactured by Dr Fixit or Shalicry 215 manufactured by STP. (iii) The rate of application of primer and waterproofing coat shall be as per manufacturers instructions. (iv) A time gap of eight hours shall be maintained between the application primer and each water proof coat after application of sealant. (v) Unit rate quoted shall be deemed to include for necessary scaffolding for execution of the same.
Demolition of unreinforced cement concrete of any description and in any position complete all as specified and as directed.
Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris to a distance exc. 1500m but n.exc. 2000m etc complete all as specified and directed by Engr-in-charge.
M/L for rendering 10mm thick in cm 1:4 on concrete roof and chajja surface to get a uniform level surface for laying of membrane treatment
M/L for PCC 1: 2 : 4 type B-1 (using 20mm graded agg) for PCC padding on RCC roof surface finished even and smoother using extra cement all as specified and directed by Engr-in-Charge.
M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- a) Apply one coat of bitumous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reinforcement weighing not less than 4.00 Kg/ Sqm applied by torch application method. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/sqm of the surface area. (e) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm.
M/L for rendering 12mm thick on fair faces of concrete pedestal over RCC roof in cm 1:4 finished even and smooth (without using extra cement)
M & L PVC Nahani trap 75mm size with grating including jointing to waste pipe fixed in cement concrete type type B1 (1:2:4)
Dismantling of cast iron/PVC or reinforced concrete drain pipes, jointed in cement mortor anf taking out of trenches if required 100/75 mm internal dia pipe complete all as specified.
S&F PVC (SWR) pipes of dia 110mm bore single socketed in any length with rubber ring joints fixed to walls.
S&F PVC (SWR) pipe of 75 mm bore in single socketed in any length with rubber ring joints fixed to walls..
S&F in repairs PVC (SWR) bends of 110 mm dia bore with access door
S&F PVC (SWR) bends of 110 mm dia bore
S&F PVC(SWR) vent cowl of 110mm dia bore.
S&F PVC (SWR) branch piece, double (double Y) equal or unequal for 110 mm dia
S&F PVC (SWR) branch piece, single (single Y) equal or unequal 110 mm dia
S&F in repairs PVC (SWR) bends of 75mm dia bore with access door
S&F PVC (SWR) branch piece, single (double Y) equal or unequal 75 mm dia
S&F PVC (SWR) branch piece, single (single Y) equal or unequal 75 mm dia
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite
M&L for powder coated aluminium two track, two shutters (of equal width), sliding type windows without sash bars including necessary jointing clips, rubber packing, neoprene rubber gasket, aluminium snap beading, screws, aluminium fittings, handles, locking arrangement (star lock), bearings (two No's for each sliding shutters) & 4.00mm thick plain glass for glazing with & including following powder coated sections as given in 'JINDAL' catalogue complete all as specified and as directed :- (i) Frame (Bottom)-20956 (ii) Frame (Top & Side)-20966 (iii) Shutter vertical (Handle lock)-20846.(iv) Shutter vertical (Int lock)-20845.(v) Shutter (Top)-20844.(vi) Shutter (Bottom)-20847. Note :- (i) The window opening shall be provided with two shutters of equal width. (ii) The shutters shall be placed in such a manner that at a time the entire width of window can be utilized as fully glazed window. (iii) The thickness of the powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE. (iv) Sealing the gap of frame with Jamb and Cill (alround) using silicon gel at the rate of 0.05 lit/m for both faces of window.
S&F Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete
Removing building materilas such as bricks, stones, concrete, sand etc to a distance upto 15Km, beyond the lead included in the rates, including loading, unloading and stacking at the destination.
Dismantling of CGI/PGI/Galvalume sheet roofing any gauge and any thickness including ridge, valley gutter etc.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S&F steel work as in vertical post connecting to plates, including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 complete
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S&F Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ rain gutters, fixed with nessesary angle iron and self tapping screws as specified.
M&L for preparation of new steel surface of steel and applying two coats of synthetic enamel paint over a coat red oxide primer
M&L for Preparing old painted surfaces/ untreated surfaces of steel any description, over 10cm in width or grith, not otherwise described and applying one coats of Synthetic enamel paint complete all as specified and directed.,
Taking down steel/aluminium windows/ventilator of any size with all fittings complete
Demolition of Brickwork or stone/bou-lder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
S&F factory made PVC double door frame of size 50 mm x 95 mm made out of 5 mm single side prelaminted PVC sheet reinforced with MS Square tube all as specified and as directed .
S&F for 30 mm Factory made Moulded door shutter - Wood free consisting of frame made out of M.S. tube of 19 gauge thickness and size of 25 mm X 25 mm for stiles, top and bottom rails M.S. frame shall have a coat of steel primer. The inner panel shall consist of 25 mm thick High density EPSconforming to IS 4671-1984 bondedwith 2 mm termite proof, water proof and fire resistant molded PVC sheet with 2,4,6 raised panel designs in different plain and / or prelam colours after routing the Moulded design on one side & 2 mm plain and / or prelam PVC sheet on other side of the EPS. The edge of the panel is to be sealed with lipping of 10mm wide PVC sheet baton (made by sticking 2 nos , PVC sheets of 5 mmt thickness using PVC solvent cement ) and stile sides 25 mm (5mm x 5)thick and 30mm wide PVC sheet fitted along M.S tube for lock provision & for lock height 5 mm thick PVC sheet of 150 mm x 100 mm fixed with upper & lower face of inner side of EPS panel and manufacturer's specification & drawing etc, complete all as specified and directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 100 mm thick Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F Aluminium bow handles, cast type, anodised 150 mm long
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed
PCC (1:4:8) type D2 (using 40 mm graded stone aggtegate) as in pedestal of steel posts over RCC roof upto 15M height all as directed
S&F for Renewing wall/ floor tiles on any description in patches, area n exc 5 sq. m. including cutting out broken tiles, removing and cleaning loose tiles, preparing bed, removing rubbish and replacing old with new tiles to match, complete with all cuttings, etc. and laying or setting, jointing and pointing new or old tiles complete
M&L for Rendering 15 mm thick CM 1:6 on fair faces of brick work or concrete surfaces and to be finished even and smooth(without using extra lime or cement)
M&L for Preparing newely plastered surface and primng with alkali resistant priming paint and applying 2 coats of oil bound distemper on walls over 3 mm thk wall care putty
Chipping, removing, carefully loose plasetr, concrete work by low impact Hasmmer / breaker without damaging the structure & cleaning and disposal of malba out side the premises etc complere as directed by Engr-In-Charge. Hard concrete should not be removed by force.
Cleaning exposed reinforced bars throughly to remove corrosion scale using buffle wheel and emery cloth with water jet and allying two coats of nitozinc primer (Make : Fosroc or equivalent)
Providing 50x50x4mm welded mesh coated with anti corrosive chemical to exposed bars using binding wire all as specified and as directed.
Providing and applying structural grade epoxy latex bond coat prior to application of any type of mortar confirming to ASTM-C-882-91 (Arizona slant shear test) to ensure bondbetween old and new c oncrete by brush applocation (Pidilite/ Fosroc/ Shalimar)
Building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1cement: 3 part graded clened pre packed river sand 10% latex mortar by weight of cement 0.5 w/c ratio) in 20 mm thickness including levelling profilling etc complete Make- Pidilite/ Fosroc/ Shalimar
Supply and application of rust remover / converter (rebaklense RR of M/s Fosroc chemicals India ltd or Amandur (Manufactured by GK Technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after aplication incl cost of all materials rent of tools scafolding cost of brushes etc complete all as specified and directed by EIC
Supply and application of Nitozinc primer ( Manufactured by M/s fosroc chemicals India ltd) over the exposed steel from the exposed reinforcement after removing rods scales from the exposed reinforcement rods in one Sqm area including the cost of all materials ren of tools scaffolding cost of paint complete all as specified and directed by the EIC
Supplying and application of Nitcobond EP (Manufactured by M/s fosroc chemicals India ltd) epoxy bonding agent over the old concrete surfaces including the cost of all materials rent of tolls scaffolding cost of paint brush etc all complete as specified and directed by EIC
Providing additional reinforcement bars in place of more than 1/3 corroded reinforcement bars incl the charges for cutting bending placing and fixing in position using Lok-fix (Manufactured by M/s fosroc chemicals India ltd) including the cost of all materials labour cost of steel bars and scaffolding complete all as specified and directed by the EIC
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for issue under Schedule of credit and making good disturbed surfaces of walls, floors, etc.
M & L for point wiring with 1.5 sq mm single core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover / PVC Switch Board mounted on wall for mounting the switches , socket outlets , fan regulators etc all as s specified and directed for following. (a) One light/Fan point controlled by one switch.
(b) One socket 3 pin outlet 5 amp on independent board.
All as per item no 59 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm.
S&F in repairs switch piano flush type single pole one way 5 amp.
S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified.
S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type universal.
S&F in repairs switch socket combination 2 in 1,5 amp flush type.
Labour for taking down and after repairs refixing to Ceiling Fan, Exhaust Fan, any Make & any Sweep Oiling, Greasing , removing all dust with painting and replacement of unserviceable spares, complete all as directed by EIC at site. NOTE : Spares shall be measured & paid resperative item of this sch.
S&F of Tubelight Rod ultra bright LED tubelight with very high efficacy suited for installation in existing tubelight G13 lamp holder to give glare free light for 18W20W/22W complete all as required at site and as directed by Engineer -in-Charge. Make : Havells,CRYSTAL812DSTL20WLED865GLASS or equivalent of Bajaj/Philips / Wipro
S&F of surface and wall mounted reagal batten for 18W20W/22W compact batten suitable for single LED Tubelight with integral LED driver complete with all accessories complete all as required at site and as directed by Engineer -in-Charge. Make : Havells,REGALBATTENT8UPTO1X22WSSBSWH or equivalent of Bajaj/Philips / Wipro
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size completewith aluminum housing & integrated electronic driver . Make: Havells Lumiine+BS10WLED865SPCSS or equivlent Bajaj/Philips
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. Make : Anchor / Cona / Bajaj
Supply and fix new adore LED lamp 9 Watt Inverter bulb B22 CDL confirming to Cat No LHLDEGEDML8009 of Havell's or euivalent in Philips / Bajaj
S&F in replacemen MCB DB SPN 6 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
Dismantling and Refixing of Existing all types cables & wires (LT cable/Lane cable/computer cable/AC cable etc.) with high quality stainless steel galvanized cable tray, & Secondary Supports with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc fixed complete to walls and ceiling or laid in floors complete all as specified and as directed EIC at site. Note : a) All cable fully covered by cable tray. b) Due to refixing cable making good disturbed surfaces of walls, floors, etc. c) Cable tray size as per site directed by EIC. d) All cable put in proper in distance. d) making good disturbed surfaces of walls, floors and in addition constructed work rate including in this rate.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
Supply & fix of up and down LED light 10 Watt .Make:Crompton or equivalent to Shakthi/Philips/Wipro complete all as specified and directed
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
M/s S.D Construction Co
JADHAV CONSTRUCTION AND INFRASTRUCTURE
SAI SAMARTH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .