Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.4 L+₹82,336 (4.22%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.3 L+₹1.8 L (9.25%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹22.2 L+₹2.6 L (13.6%)Rejected-AOC SHARADA SMRITI H NO 840 VINAYAK KATHE ALI KEGAON ROAD URAN NAVI MUMBAI 400702 | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹24.2 L+₹4.7 L (24.0%)Rejected-AOC MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-AOC Rejected |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
24 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
ADDITION AND ALTERATION TO BUILDING NO P-1059 (REAR DERBY HANGER) AT NAVAL STATION KARANJA
2022_MES_510759_1
84137-K/E8
Open Tender
Civil Works
Item Rate
180 days
NAVAL STATION KARANJA
Please refer tender documents
8 documents required · 8 mandatory
₹500
CWE KARANJA
₹49,000
29 Mar 2022
26 Feb 2022
26 Mar 2022
26 Feb 2022
24 Mar 2022
12 Mar 2022
60 days
Amount
Complete removal of existing water proofing treatment any description upto concrete surface of roof slab including cleaning, with wire brushing, watering, removal of debris upto 1500m distance complete all as specified and as directed by Engr-in-charge. Note: Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work.
Material and labour for cleaning the new surfaces concrete with wire brushing and applying water proofing treatment as under:- (i) Apply oil bound bitumen primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree cesius on the pepared dry roof surface. (ii) Laying torch applied APP polymer modified membrane 4mm thick with non-wooven ployster mat as reinforcement weighing not less than 4.50 Kg/Sqm mineral finished by thermo fusion process. The APP membrane shall be of:- (iii) Over the membrane, provide a finishing with two coats of Solar reflective bituminious aluminium paint @ 0.10 Kg/Sqm as prescribed by manufactures.
Material and labour for rendering 10mm thick cement plaster in CM (1:3) on roof top surface including WPC by weight of 3% of total cement content complete all as specified and as directed by Engr-in-charge. Note: WPC will be measured and paid separately.
Material and labour for PCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in roof /chajja padding for maintaining roof /chajja minimum slope 1:6 complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster on brick or stone walls, etc., including racking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 15mm thick in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 20mm thick on fair faces of brick /concrete surfaces with two coats i.e 15mm thick backing coat in CM (1:6) and 5mm thick finishing coat in CM (1:4) including WPC, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. Note: WPC will be measured and paid separately.
Supply only integral water proofing compound complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 5mm thick in CM 1:3 on ceiling surface complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over and including 3mm thick wall care putty, and filling cavities with wall care putty filling after complete removal of existing treatment complete all as specified and as directed by Engr-in-charge.
Material and labour for new or old wall complete removal of existing treatment on external wall surface by sanding machine or any other mechanical means thereafter washing, rubbing down the surface, in order to remove dust, dirt, loose particles etc., and fill the visible cracks /joints with crack seal caulking compound after cleaning the surface by clean water. Apply a coat of primer (water based primer) and allow to dry for six hours. Thereafter, apply two coats of water proofing treatment on wall (WB high build anti carbonation cum water proofing) including a coat of exterior grade weather proof acrylic emulsion paint by using Airless Paint Sprayer machine at any height of the building by using scaffolding. The material used for the treatment must have crack binding ability, water proofing properties and flexible (i.e cover hairline cracks upto 2mm effectively) and be elastomeric complete all as specified and as directed by Engr-in-charge. Note: External water proofing treatment on wall at any height of the building including acrylic paint shall be applied by mechnaically Airless paint sprayer machine only.
Material and labour for preparation of new plastered surface of ceiling and applying three coats of white wash on ceiling complete all as specified and as directed by Engr-in-charge.
Material and labour for prepration of old plastered/ decorated surfaces of walls and applying one coat of oil bound distemper on plastered/ decorated wall surfaces complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of old wall surfaces of any description and applying one coat of acrylic (antifungal) exterior grade paint of camouflage pattern complete all as specified and as directed by Engr-in-charge.
Dismantling expanded metal/ welded wire fabric not exc 4 kg/ sqm any thickness or mesh, fixed with steel or wood fillets, if any complete all as specified and as directed by Engr-in-charge.
Supply and fix for welded steel wire fabric not exc 4 kg/ sqm supplied and fixed complete to wood or steel members complete all as specified and as directed by Engr-in-charge.
Material and labour in repairs 6mm thick non asbestos fibre cement building designed boards in ceiling fixed or laid /inserted to timber /GI /Aluminium frame work with screws complete all as specified and as directed by Engr-in-charge.
Material and labour for preparing of new false ceiling surfaces and apply two coats of oil bound distemper over a coat of alkali-resistant primer complete all as specified and as directed by Engr-in-charge.
Supply and fix for framed work of rolled mild steel conforming to Gde Fe 410-W (Gde -E-250) quality -A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., drilled for fixing of steel sheeting or other covering; doors, ladders etc., to be prepared for hanging or sliding with and including either hooks and hinges, wheels or steel hanging door fittings (exclusive of steel sheeting, running rails and guides) and hanging, fastening and fixing complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new previously untreated steel and iron surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromium primer complete all as specified and as directed by Engr-in-charge.
Chipping, removing carefullly concrete work by low impact hammer, breakar without damaging the structure and cleaning and disposal of debries out side the premises etc., complete all as specified and as directed by Engr-in-charge. Note: Hard concrete should not be removed by force.
Material and labour for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc., complete and applying two coats of alkaline rust converting primer on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and as directed by Engr-in-charge.
Material and labour for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be by brush complete all as specified and as directed by Engr-in-charge.
Material and labour for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete and new concrete by brush application complete all as specified and as directed by Engr-in-charge.
Material and labour for building up the profile of structural members by using latex additives (MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond- 5 Cement- 15 sand) in damaged areas in 30mm thickness including levelling profliling etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor complete all as specified and as directed by Engr-in-charge. Note: Reinforcement shall be measured and paid separately and rates including jacketing, formwork and micro concrete.
Material and labour for applying concrete protection coating on finished structural members exposed to atmosphere complete all as specified and as directed by Engr-in-charge.
Material and labour for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty and let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the carck with a liberal application of the epoxy putty.
Material and labour for injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers and migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency, mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved /specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc., complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled complete all as specified and as directed by Engr-in-charge.
Material and labour for injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including, mixing of materialas: Mixing of material components (part A&B) in the required quantities as per manufacturer's instructions by weigh batching. Grouting: Fill the grouting gun with concrete penetrating corrosion inhibitor. Maintain desired pressure in the gun by air compressor; maintain the pressureat exit (2 to 3 kg/cm2) by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements @ 100ml per nozzle. Repeat the process for all the nozzles complete all as specified and as directed by Engr-in-charge.
Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and as directed by Engr-in-charge.
Supply and fix for flame proof LED flood light 100W fitting fitted on wall surface complete all as specified and as directed by Engr-in-charge. Note: The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items.
Supply and fix for FLP flexible metalic hose conduit 500mm long for 19 /20mm dia fixed on directed place complete all as specified and as directed by Engr-in-charge.
Supply and fix for copper strip 32 x 6mm fixed on wall with insulators complete all as specified and as directed by Engr-in-charge.
Supply, install, testing and commissioning of fire alarm control panel complying with BSEN 54 single loop panel of capacity from 99 detectors and 99 modules upto 200 detector and modulese including battery backup up to 12 Hrs complete all as specified and as directed by Engr-in-charge.
Supply, fixing and testing addressable manual call point resettable type of suitable size complete all as specified and as directed by Engr-in-charge.
Supply, fixing and testing addressable type multisensor detector with heat and smoke combination confirming to EN- 45 standard of size suitable to work on 24V DC (12 V DC - 28 V DC) fixed with LED made out of frame retardant plastic confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Supply and fix for fire alarm sounders/ sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5m with sound output variation of + 5 DB for 500 meter range complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sqmm, 2 core 1100 Volts grade complete all as specified and as directed by Engr-in-charge.
Dismantling and removing old unserviceable compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed compressor unit of capacity 12.5 TR complete with all standard accessories as per existing model installed at AC plant complete all as specified and as directed by Engr-in-charge. Notes: (i) Sealed unit shall be purchased from authorised dealers/ agents. (ii) Cost of labour, fixing, T&P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary elelctrical check i.e checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling the compressor the freon gas to be taken in empty cylinder by the help Ice or as directed by Engineer-in-Charge.
INDIA ENGINEERS AND CONTRACTORS
Dinesh Enterprises
DIGITAL SERVICES
ECOBUILD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .