Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85,000Accepted-AOC S NO 132 2 3 PLOT NO 22 GULMOHAR PARK ITI ROAD AUNDH PUNE 411 007 | PUNE | PUNE | MAHARASHTRA | 411007 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.9 L+₹1.1 L (124.9%)Accepted-AOC | L2 | Accepted-AOC L2 | |
| 3 | L3₹2.7 L+₹1.8 L (217.6%)Accepted-AOC | L3 | Accepted-AOC L3 | |
| 4 | L4₹3.9 L+₹3.1 L (361.6%)Accepted-AOC | L4 | Accepted-AOC L4 | |
| 5 | L5₹4.3 L+₹3.4 L (400.7%)Accepted-AOC 13 A AND 12D D SECTOR INDUSTRIAL ARERA GOVINDPURA BHOPAL M P | BHOPAL | BHOPAL | MADHYA PRADESH | 462023 | L5 | Accepted-AOC L5 |
Tender Value
Refer Docs
Closing Date
13 Oct 2020, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, P.W. Division Panvel
Office of The Executive Engineer, Public Works Division Panvel , Bhingari , Panvel
Online Item Rate e-Quotations for following items are invited by the Executive Engineer, Public Works Division, Panvel on behalf of Government of Maharashtra by Electronic Tender Management System mahatenders.gov.in from Companies /Agencies /Firms /S
2020_PWR_612375_1
NIT_NO_19_FOR_2020_21
Open Tender
Civil Works
Item Rate
7 days
Panvel
As Per Tender Documents
2 documents required · 2 mandatory
₹0
Exempted
5 Nov 2020
25 Sept 2020
15 Oct 2020
25 Sept 2020
13 Oct 2020
25 Sept 2020
60 days
Amount
ULTRA HIGH-PERFORMANCE FIBER REINFORCED CONCRETE (UHPFRC) Providing and laying in situ Ultra High-Performance Fiber Reinforced Concrete Mix M140, formulated by combining Portland Cement, Supplementary Cementitious Materials, Reactive Powder, Lime Stone and or Quartz Flour, Micro-Silica, Silica Fumes, Fly-Ash, Granulated Slag, Admixtures for Early Gain of Strength, Chemical Admixtures, Super Plasticizers, Fine Sand, High-Range Water Reducers, Metal or Organic Fibers (High Carbon Steel, Polypropylene, PVA, Glass, Carbon or a combination of these types) having High Flow Characteristic to make it self-Compacting. UHPFRC matrix shall be very dense with a minimal disconnected pare structure resulting in low permeability. with compressive strength minimum 140MPa, Flexural strength minimum 25MPa and Modulus of Elasticity minimum 50GPa, including ramming, vibrating, curing, form work, centering and finishing excluding reinforcement etc. complete. (with fully automatic microprocessor-based PLC with SCADA enabled concrete batch mix plant / pan mixer and fine aggregates of required specifications (Natural Sand / VSI Sand finely washed etc.) etc. complete as per directions of Engineer-In-Charge conforming to IRC:SP:70:2005, High Early Compressive Strength as per ASTM C 39 (AASHTO T 22), High Early Flexural Strength as per ASTM C 78 (AASHTO T 97), Abrasion Resistance as per ASTM C 944, Low Permeability as per ASTM C 1202 (AASHTO T 277), Chloride Penetration as per AASHTO T 259 & T 260, High Resistivity as per ASTM G 59, Low Absorption as per ASTM C 642, Low Diffusion Coefficient as per ASTM, Resistance to Chemical Attack, Resistance to Sulfate Attack as per ASTM C 1012, High Modulus of Elasticity as per ASTM C 469, High Resistance to Deicer Scaling as per ASTM C 672, Low shrinkage as per ASTM C 157, Low Creep as per ASTM C 512 and any other Codes, Standards applicable.
STUDS FOR CONCRETE Drilling and installation of 10 mm dia. Stud Anchor Bar as shear connector using approved resin epoxy chemical by injection for installation of 10 mm diameter stud anchor, drilling hole of 12mm dia. in the concrete of RCC members to a depth of minimum 100 mm at 500 mm c/c or at suitable grid in zig-zag fashion using approved drilling machine and drill bit, cleaning the hole using wire brush and blow out pump for removing dirt and dust from the hole. After proper cleaning, inject approved resin epoxy chemical using approved chemical anchoring gun. Pull out strength should be min 8 KN per anchor. Insert the stud rod in the hole by slightly rotating the rod. Once the stud is inserted, allow it to set for min 30-45 min and final curing time 6-8 hours depending on ambient temperature etc. complete as per the directions of Engineer-In-Charge.
CONCRETE GROUTING BY GRAVITY PONDING Providing and filling Cracks / Voids / Honeycomb with Gravity Grouting of Polymer Cement Grout (10 % of polymer by weight of cement) by using ponding method etc. complete as per directions of Engineer-In-Charge.
ANTI CARBONATION PAINT Providing and applying two coats of Anti Carbonation Paint to meet the requirements of anti-carbonation and elastomeric waterproofing with durable protection to concrete or concrete structures to form a flexible membrane, which prevents chloride, ion ingress. It shall have UV & weather resistance properties. It shall provide good mechanical and abrasion resistance to the exterior. The surface should be made, clean and free from oil, grease, loose particles, dust etc. It should be applied by Roller, Brush or Spray. For cleaning / Thinning water to be used. Thinner (Volume) Should be 5-10 %. It shall include one coat of Acrylic Primer (W.B.), one coat of penetrating primer sealer, two coats of Anti Carbonation paint and two coats of shield exterior filler. Its dry film thickness (DFT) should be 100-150 microns per coat. Its drying time shall be touch dry in 20-30 minutes, hard dry in 24 Hours etc. complete as per directions of Engineer-In-Charge.
PREFABRICATED WELDED REINFORCEMENT MESH Providing electrically fused welded mesh for CRS (Corrosion Resistance Steel) reinforcement as per I.S.1566 for all R.C.C. Works as per detailed drawing of Deck Slab of Bridge having Ys = 550 Mpa and UTS = 585 Mpa. The maximum size of the weld mesh sheet shall be 6.0 mt x 2.20 mt. Laying, tying and fixing of the welded mesh in position in all respect as per detailed drawing for concrete reinforcement of Deck Slab of Bridge following overlapping norms mentioned in I.S.456-2000 etc. complete as per directions of Engineer-In-Charge. A) 10mm Dia. Electrically fused Welded Mesh
PREFABRICATED WELDED REINFORCEMENT MESH Providing electrically fused welded mesh for CRS (Corrosion Resistance Steel) reinforcement as per I.S.1566 for all R.C.C. Works as per detailed drawing of Deck Slab of Bridge having Ys = 550 Mpa and UTS = 585 Mpa. The maximum size of the weld mesh sheet shall be 6.0 mt x 2.20 mt. Laying, tying and fixing of the welded mesh in position in all respect as per detailed drawing for concrete reinforcement of Deck Slab of Bridge following overlapping norms mentioned in I.S.456-2000 etc. complete as per directions of Engineer-In-Charge. B) 8mm Dia. Electrically fused Welded Mesh
VERMICULITE FIRE RESISTANCE PLASTER Providing and applying Vermiculite Fire resistance plaster at soffit of Bridge deck slab for the deck bottom surface that is treated with carbon fiber polymer, including all necessary materials, labour, machinery, transportation etc. complete.
Providing and fixing Chemical Anchor fasteners of 12mm dia. and 150 mm length of HILTI or equivalent make including chemical grout, injecting gun etc. complete.
Progressive Civil Construction Co Pvt Ltd
Banka Constructions
STRUCT REHAB
Sanfield (India) Limited
M/s BANDHU TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .