| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.9 L+₹2.2 L (6.68%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹35.2 L+₹2.5 L (7.49%)Rejected-Finance 3 3430 NICHOLSON ROAD KASHMERE GATE DELHI DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹37.8 L+₹5.1 L (15.4%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹39.4 L+₹6.6 L (20.2%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | Arneja Builders L2 | SWAMI ENGINEERS L1 | m/s panchmukhi builders L5 | Buttar Construction Co. L4 | RUPINDER SINGH SODHI L6 | DELTA CONSTRUCTION CO L7 | ANIL KUMAR AND CO L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00'Notes: (i) Please refer Schedule 'A' Notes of tender documents. | ||||||||||
| 1.01 | Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed by Engineer-in-Charge | 320 | SQM | 10 ₹3,200 | 5 ₹1,600 Lowest | 10 ₹3,200 | 10 ₹3,200 | 10 ₹3,200 | 10 ₹3,200 | 10 ₹3,200 |
| 2.00 | Demolition of mud in roofs, any thickness, including plastering and leeping(whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer-in-Charge. | 25.6 | CUBIC METRE | 100 ₹2,560 | 30 ₹768 Lowest | 80 ₹2,048 | 180 ₹4,608 | 250 ₹6,400 | 250 ₹6,400 | 50 ₹1,280 |
| 3.00 | Material & labour for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge. | 320 | Sqm | 5 ₹1,600 Lowest | 5 ₹1,600 Lowest | 5 ₹1,600 Lowest | 8 ₹2,560 | 10 ₹3,200 | 10 ₹3,200 | 5 ₹1,600 Lowest |
| 4.00 | PCC 1:3:6, type C-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 45mm to maintain slope of 1:100, complete all as specified by Engineer-in-Charge | 17.6 | CUBIC METRE | 2,800 ₹49,280 | 2,500 ₹44,000 Lowest | 2,500 ₹44,000 Lowest | 3,500 ₹61,600 | 3,000 ₹52,800 | 3,400 ₹59,840 | 3,000 ₹52,800 |
| 5.00 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified by Engineer-in-charge | 120 | R.M | 50 ₹6,000 | 50 ₹6,000 | 60 ₹7,200 | 35 ₹4,200 | 50 ₹6,000 | 50 ₹6,000 | 5 ₹600 Lowest |
| 6.00 | Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer 0.40 Itr/sq m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70-160 cps Over the coat, the layered APP membrane shall be laid using butane torch and sealing all joints etc after the surface complete as per standard practice as per manufacturers instructions. The laying of membrane shall be got done as per the instructions of manufacturer, all as and directed by Engineer-in-charge. | 340 | SQM | 260 ₹88,400 | 250 ₹85,000 | 280 ₹95,200 | 245 ₹83,300 Lowest | 450 ₹1,53,000 | 320 ₹1,08,800 | 250 ₹85,000 |
| 7.00 | Material & labour for 20- 22 mm Precast PCC plain factory made tiles, ISI marked, 22 mm thick, of size 250 mm x 250 mm, machine pressed and cut polished and set jointed and pointed in neat cement slurry and fabricated using grey cement & no pigments. over and including 15 mm thick cement mortar (1:4) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified and directed by Engineer-in-Charge. | 320 | SQM | 470 ₹1,50,400 | 500 ₹1,60,000 | 380 ₹1,21,600 Lowest | 525 ₹1,68,000 | 450 ₹1,44,000 | 500 ₹1,60,000 | 450 ₹1,44,000 |
| 8.00 | Material and labour for PCC 1:3:6, type C-1 using 20mm graded stone aggregates as in edge, chamfered and coping etc, complete all as specified and directed by Engineer-in-Charge | 2 | CUM | 2,000 ₹4,000 | 3,000 ₹6,000 | 2,500 ₹5,000 | 3,000 ₹6,000 | 3,000 ₹6,000 | 1,500 ₹3,000 Lowest | 1,500 ₹3,000 Lowest |
| 9.00 | Supply & fixing for PVC(HDPE) rain water pipes, 150 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc including taking down existing damaged CI rain water pipe complete all as specified and as directed | 200 | RM | 200 ₹40,000 | 170 ₹34,000 | 200 ₹40,000 | 450 ₹90,000 | 100 ₹20,000 Lowest | 250 ₹50,000 | 150 ₹30,000 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
28 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ MOHAMMED AQIL AZEEM
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
COMPREHENSIVE REPAIR FOR JCO AND OR MD ACCN IN KULWANT SINGH ENCLAVE UNDER AGE B/R I AT PATIALA MIL STN
2025_MES_723385_1
GE (N)/TOKEN-51/2025-2026
Open Tender
Civil Works
Item Rate
240 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE N PATIALA
₹90,000
Yes
19 Sept 2025
30 Jul 2025
30 Aug 2025
30 Jul 2025
28 Aug 2025
14 Aug 2025
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed by Engineer-in-Charge
Demolition of mud in roofs, any thickness, including plastering and leeping(whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer-in-Charge.
Material & labour for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge.
PCC 1:3:6, type C-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 45mm to maintain slope of 1:100, complete all as specified by Engineer-in-Charge
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified by Engineer-in-charge
Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer 0.40 Itr/sq m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70-160 cps Over the coat, the layered APP membrane shall be laid using butane torch and sealing all joints etc after the surface complete as per standard practice as per manufacturers instructions. The laying of membrane shall be got done as per the instructions of manufacturer, all as and directed by Engineer-in-charge.
Material & labour for 20- 22 mm Precast PCC plain factory made tiles, ISI marked, 22 mm thick, of size 250 mm x 250 mm, machine pressed and cut polished and set jointed and pointed in neat cement slurry and fabricated using grey cement & no pigments. over and including 15 mm thick cement mortar (1:4) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC 1:3:6, type C-1 using 20mm graded stone aggregates as in edge, chamfered and coping etc, complete all as specified and directed by Engineer-in-Charge
Supply & fixing for PVC(HDPE) rain water pipes, 150 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc including taking down existing damaged CI rain water pipe complete all as specified and as directed
Supply & fixing PVC (SWR) bends/tees of any radius for 150mm bore as in repair complete all as specified.
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises
Material & labour for Non - skid coloured Ceramic tiles 400 x 400mm 10mm thick (square/ rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over and incl 15 mm thick cement mortar (1:6) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-Charge.
Material & labour for Glazed ceramic coloured printed/digital tiles 7 to 8mm thick area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surface such as skirting , dado etc. over and including 10 mm thick rendering in cement mortar 1:4 thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles complete all as specified and directed by Engineer-in-Charge.
Material & labour for Virified Ceramic tiles(light shade) 10 mm thick (square/ rectangular) polished, size of each 600mm X 600mm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match, joined in cement slurry over and incl 15mm thick cement mortar (1:6) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-charge.
M & L for 18- 20mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick cement plaster (1:4) complete all as specified.
Material & labour for Baroda green Marble work 18 to 20mm thick (table rubbed and polished) in steps, windowcills, laid over 15 mm in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including rubbing and polishing to mirror finish complete to be fixed in any position as described and specified.
Material & labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and directed by Engineer in charge.
Demolition of cement concrete un -reinforced in ground floors and pavings complete all as specified and directed.
Material and labour for Plain cement concrete 1:7:12 mix, (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed.
Material and labour for carrying out water proofing treatment of sunken floor complete all as specified under:(i) The concrete/wall surface shall be cleared thoroughly of all laitance,loose particles,dust,grease etc and any friable and unsound area which shall be chipped,cleaned and thereafter pre-wetted to a satured surface dried condition. (ii) In case of pot holes/superficial cracks,the same shall be repaired with polymer modified mortar using URP as admixture @ 10% of cement content. (iii) The polymer modified mortar using URP as admixture @10% of cement content shall also be applied on vertical surfaces after removing of plaster upto 60 cm height.(iv) The surface thus prepared shall be coated by applying 2 coats of Dr Fixit Hydrochem super in the sunken areas and extending it upto 150 mm above the finished floor level.This includes layer of a 150 mm wide strip of an open woven glass fiber mesh over the PCC benching (Gole) on the 1st coat whille it is still wet.(v) Rendering 15 mm in CM 1:4 admixed with integral water proofing compound @ 200 ml per bag of cement complete all as specified and directed by the Engineer-in-Charge.
Providing 50 mm dia GI pipe light grade spouts complete all as specified and directed.
Material & labour for PCC with type B-0. 1:2:4 (20mm graded aggregate) 40 mm thick as in flooring and finishing the floor even and smooth without using extra cement..
Supply & fixed in repair vitreous china premium/1st quality wash basin white/ivory/off white, flat back, size 500x400 mm including pedestal, screws & plug and brackets etc. all accessories as recommended by manufacturer incl inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union and incl 32mm brass CP waste coupling and waste pipe complete in all respect as per manufacturer's instructions and taking down existing of any description/size all as specified.
Supply & fixing vitreous china premium/1st quality wash down water closet pan floor mounting (pedestal pattern/EWC) S/P trap white/ivory including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe CP 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm S/P trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors except G.F.and taking down existing of any description/size complete in all respect all as specified.
Supply and fixing Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
Supply & fixed in repair flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
Supply & Fixing of Cast iron spun pipes 100mm bore pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
Supply & Fixing of Cast iron soil, waste and vent pipe, Centrifugal type 100mm bore, spun cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps (25x3 mm), nuts , bolts etc. and making necessary connections complete all as specified.
Supply & Fixing of Cast iron spun pipes 75mm bore pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
Supply & Fixing of Cast iron soil, waste and vent pipe, Centrifugal type 75mm bore, spun cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps(25x3mm), nuts , bolts etc. and making necessary connections complete all as specified.
Supply & fixing for cast iron branch pieces single Centrifugal type (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 100 mm bore pipe, fitted with oval access door jointed with cement joint, complete all as specified.
Supply & fixing for cast iron branch pieces single Centrifugal type (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 75 mm bore pipe, fitted with oval access door jointed with cement joint, complete all as specified.
Supply & fixing for CI Cowl Centrifugal type suitable for 100 mm bore pipe as in repair, complete all as specified.
Supply & fixing for Cast iron bends/Tee duck foot or heel rest, radius for 75 mm bore pipe, complete all as specified and directed.
Supply & fixing for Cast iron bends/Tee duck foot or heel rest, radius for 100 mm bore pipe, complete all as specified and directed.
Supply & fixing Salt-glazed stoneware gully traps,Centrifugal type 150x150mm size, square or round mouthed, type 'P' or 'S' incl CI grating fixed in repair complete all as directed and specified.
Supply & fixing Cast iron floor trap 100 mm dia and 600 mm long including jointing with solvent cement in repair complete all as specified and directed by Engineer-in-Charge.
Supply & fixing doubled layered rotational moulded polyethylene white water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified and directed.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixingor removal to store.
Supply and fixing 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified.
Supply and fixing 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified.
Supply and fixing 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply & fixed in repair Bib taps, CP, fency type long body with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete in all respect all as specified.
Supply & fixed in repair 15 mm dia Stop cock cast copper alloy fancy type CP with long shank and cup (concealed type), screw down high pressure, screwed both ends for iron pipe or for union and fixed complete all as specified and directed
Supply & fixed in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
Supply & fixed in repair stainless steel sink with drainage board, 1.00 mm thick, glossy finish, for kitchen with plugs washers and waste coupling of 32mm dia and including cantilever cast iron brackets, connecting union, etc, overall size 915mm x460/928mmx458mm with bowl size 410x 355x185mm/430x355x200 with wall connection pipe & wall flange and making good disturbed portion in CM 1:3 or PCC 1:2:4 complete all as specified and directed.
Supply & fixed in repair Sink Cock wall mounted with swinging spout and with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified and directed.
S&F CP peg set of 6 hooks and including all accessories like screws etc as recommended by manufacturer and complete fixing in position complete all as specified.
Supply & fixing Stainless steel plate rack made out of 1 mm thick stainless steel sheet of size 900x750x250mm complete all as specified and directed.(wt shall not be less than 3kgs)
Supply & fixed in repair Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete in all respect all as specified.
Supply & fixed in repair PVC connections 15mm size with PTMT nuts of length 450mm. complete in all respect all as specified.
Supply & fixed in repair Chromium plated shower roses with or without swivel joints, any for 15mm pipes, including fixing to steel pipe or union. complete in all respect all as specified.
Supply & fixed in repair Pillar taps, fency type, long neck, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and fixed in repairs all as specified.
Supply & fixed in repair acrylic glass shelf assembly for soap dish and appropriate space for placing other things like tooth brushes comb tooth paste etc and fiexed to walls with plug and brass chromium plated screws complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar , including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by engineer in charge
Material & labour Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius in cement mortar (1:6), complete all as specified and directed by engineer in charge
Material & labour Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in with cement mortar(1:4), complete all as specified and directed by engineer in charge
Supply & fixing stainless Harrison rails, mild steel, chromium plated 25mm dia with fixing brackets, stops, rollers etc for curtain rod incl all fixing complete all as specified and directed by Engineer-in-Charge.
M&L Built in cup boards with pressed steel frame of size 75x45x1.25mm thick and shutter of 1.00 mm thick MS sheet including spray painting 2 coats over a coat of red-oxide primer on steel surfaces all around (overall external size of cup board shutter incl frame shall be taken into consideration for the purpose of measurement) including One No hanging rod of CP steel 20mm bore with brackets & two Nos peg set of three pegs each fixed inside the shutter complete fixed in repairs i.e, including taking down and removal of old unserviceable wooden or steel built-in-cupboards incl frame from site all as specified and directed by Engineer-in charge.
Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent, having 100% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturer specifications. Make of product:SIKKA/FOSROC/DR FIXIT
Supply and apply of rust remover cum passivator by brush in two coat @ 0.3 kg/m2/coat of Density: 1.01 Kg/l at 300C complete all as per manufacturer's instructions and all as specified. Note : (i)The application of rust removal shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this item. Make of product:SIKKA/FOSROC/DR FIXIT
Supply and apply cementitious coating for corrosion protection having a cement base polymer modified rebar corrosion protection system by applying the first coat approx 1mm thick layer of product carbonation resistance 2mm of sikatop ArmatecR -108 or equivalent as specified corresponds to 20 mm of normal mortar;bond strength 1N/mm2 according to ASTM C 882-78 applying @ 4kg/m2 for two coats onto the prepared reinforcing steel with a medium-stiff brush.it is unavoidable that specified product will also be applied in the same way after a waiting time of 2-3 hours (+20C) complete all as per manufacturers instructions and all as specified. Note: (i)The application of cementitious coating for corrosion protection shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this item. Make of product:SIKKA/FOSROC/DR FIXIT
Proving ,mixing & applying two components Epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturers apecification incl prepration of surface by chipping and throughly cleaning of surface complete wherever required and as per directions of Engineer-in-charge. Consumption: o.5 kg/m2 complete all as per manufacturers instructions and all as specified. Product requirements : complies with ASTM C 881 Type II Grade 2 class B+C. Note: (i)The application of epoxy bonding primer shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this item. Make of product:SIKKA/FOSROC/DR FIXIT
Supply and apply a pre-batched one component polymer modifies cementitious patch repair mortar in 25mm thickness. Yield:approx 0.84 ltr/kg. System requirements:compressive strength =50 N/mm2 (28 days) according to ASTM C 109 : flexural strength = 3 N/mm2 (7 days) according to ASTM C 293-79 consumption of 2.1 kg/sqm/mm Note: (i)The applicator of polymer repair mortar shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of this item. Make of product:SIKKA/FOSROC/DR FIXIT
S & F Factory made pre-laminated PVC solid board 18-20mm thick pre-laminated both sides with wooden finished on one side and white finished laminated on other side as in cup-board front shutters complete fixed in position in all respect all as specified and including supply and fixing of following items:- (a) Stainless Steel (304 Grade) Finished tower bolt 100mm long - 1 nos per leaf (b) Stainless Steel (304 Grade) Finished Handles100mm - 1 nos per leaf (c) Stainless Steel (304 Grade) Finished magnectic catchers0 mm - 2 nos per leaf
S&F pre-laminated PVC solid board as in frames for cupboards shutters 40mm thick (doubled sandwiched of 20mm) prelaminated on one side with wooden finished complete fixed in position in all respect all as specified.
S&F S & F Continuous (piano) hinges,mild steel, bright finish or electrogalvanised in 30mm ) complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC and chicken wire gauge will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge.
Material & labour for cement plastering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Material & labour for cement plastering 10 mm thick in cement mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed.
Complete removal of existing treatment of any type/description from ceilings/RCC surfaces etc with mechanical means/grinder complete all as specified and directed.
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.0 to 2.0 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed
Applying 02 coats of exterior emulsion weather proof paint (light shade) to external new plastered walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommended by manufacturer of exterior emulsion and primer complete all as specified and directed.
Applying one coat of exterior emulsion weather proof paint (light shade) to external old plastered walls/RCC surfaces/ soffits of chajjas/roof projections/cantilevers/balcony etc surface complete all as specified and directed.
Applying 02 coats of oil bound distemper (light shade) to new plastered wall surfaces over & including a coat of wall primer as recommended by manufacturer of OBD and primer complete all as specified and directed.
Applying one coat of oil bound distemper (light shade) to old plastered wall surfaces complete all as specified and directed.
Material & labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of old plastered of ceiling and applying one coats of white wash complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of old steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
Material & labour for Preparation of old wood surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
Supply & fixing Mild steel, plain, black sheet 3mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by engineer-in-charge.
M & L for mild steel framed work as in brackets etc for cooler stands,supportings frame work for sun shade etc framed steps/stairs etc complete using MS railing/angle iron Steel bars gusset plate etc complete all as specified & directed complete.
Material & labour for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection/ floor finish, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints filled with Bituminous mastic asphalt complete all as specified and directed by Engineer-in-Charge.
Material & labour for Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of walls, ceiling etc all as specified and directed Engr-in-charge.
M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer in-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. Note:- V- Rate of cutting chasing included in the unit rate quoted for this item
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by 2 way and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed.Note-I- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-II- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -III - cost of Eye/bottle thimbles used for connection for 2 way switch is deemed to be included in the unit rate quoted for this item. Note:-III- Rate of cutting chasing included in the unit rate quoted for this item
All as per Sl item No 94.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
All as per Sl item No 94.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
All as per item No.94.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board.
M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer iin-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item.
All as per Sl item No 99.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
All as per Sl item No 99.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
All as per item No 99.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board.
Supply and fix Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed by Engr-in-charge.
Supply and fix Modular switch 1 way, 16 Amps, 1 module complete all as specified and directed by Engr-in-charge.
Supply and fix Modular switch 2 way, 6 Amps, 1 module complete all as specified and directed.
Supply and fix Modular Bell switch 1 way, 6 Amps, 1 module complete all as specified.and directed by Engr-in-charge.
S & F Bell ding dong electronic complete all as specified and directed by Engineer-in-charge.
Supply and fix Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed by Engr-in-charge.
Supply and fix Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed by Engr-in-charge.
Supply and fix Fan regulator modular type 2 module complete all as specified and directed by Engr-in-charge.
S&F Ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed by Engr-in-charge.
Material and labour for in replacement angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 23 watts for batten fitting, including plastic square board of required size, complete all as specified and directed.
S&F 9 watt LED Bulb with base cap B22/E27 type minimum 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500 /3000 K with CRI of LED >90 complete all as specified and directed.
Supply and fix in replacement of New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge.
S&F Ceiling/surface mounted Slim design LED round Downlight with Superior light output and internal driver 9/10 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge.
M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Supply and fix Modular switch in repair 1 way, 6 Amps, 1 module, 230 volts make and fitment as per gound requirement complete all as specified.NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular switch in repair 1 way, 16 Amps, 1 module, 230 volts complete all as specified. NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular socket in repair 5 pin 6 Amps, 2 module 230 volts complete all as specified. NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular socket in repair 5 pin 6 &16 Amps, combination type 2 module complete all as specified. NOTE-contractor shall visit the site to check make and size of item.
Supply and fix in replacement of metal flush box of 2 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 3 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 4 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 6 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 8 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 2 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 3 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 4 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 6 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 8 module in MAP qtrs located in NEW cantt complete all as specified and directed.
M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.0 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Supply and fix in replacement of MCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement epoxy power coated MCCB distribution distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with common bus-bar rated 200 Amp at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth (iii) Connection of cable with VTPN shall be done through appropriate size of thimble.
Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
S & F in replacement of MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be C curve as directed by engineer in charge)
S & F in replacement of MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be C curve as directed by engineer in charge)
S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be C curve as directed by engineer in charge)
S & F in replacement of Sheet metal enclosure DB TPN 4 ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link flush mounting type, drilling holes for incoming and out going cables complete with IP-43 protection complete all as specified and directed by Engr-in-charge
M & L for replacement of UNSV Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement @ 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation including charcoal and common salt in alternative layers 15 cm Thick mixed refilling of soil etc complete all as directed by Engineer-in-charge.
Supply & fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K cool /warm white of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 10/12W 6500K of capacity ,watt,2 ft long incl 3 core flexible wire 0.5 sqmm copper conductor cable all as specified and directed by Engr-in-charge.
M & L for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 1.5 sq. mm main cable + 1 run of 1.5 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item.
M & L for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 2.5 sq. mm main cable + 1 run of 2.5 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item.
Supply and fix in replacement of 9/12 watt LED light fitting decorative type wall mounting fixture including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to conector of the light complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge.
Fixing only Single phase electric meter 10-40 amp complete all as specified and directed by Engr-in-charge. Note:- Electric meter will be issued under Sch B only
Supply and fix DB box MCB protected socket PVC plastic base having MCB of suitable rating 20 amp C series complete all as specified and directed by engr-in-charge.
Arneja Builders (BID ID -3395950)
ANIL KUMAR AND CO (BID ID -3401889)
Buttar Construction Co. (BID ID -3401972)
m/s panchmukhi builders (BID ID -3399540)
RUPINDER SINGH SODHI (BID ID -3408905)
DELTA CONSTRUCTION CO (BID ID -3409197)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .