RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Truck Mounted Suction Machine ( 1 pieces ) ( Under PAC ) Make na Model susm-2lc 1/7 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Certification Chassis Certification ARAI/VRDE/ICAT Yes * Chassis Certification ARAI/VRDE/ICAT No AAFN 0183 * Form 22 A - For compliance with pollution standards
Requiredsafety standards of components and road worthiness as per CMVR Rules Yes * Conforming to IS:13496 for Suction Machine for cleaning Sewers
RequiredManholes and ancillary structures provided on sewer line and closed storm water drains Yes * Availability of test reports for all critical components from the manufacturer or OEM of vacuum pumps
Requiredpower takeoff unit etc shall be from any ILAC NABL accredited Central Govt Lab to be furnished to buyers on demand Yes * Registration To Local RTO (Regional Transport Office)/RTA(Regional Transport Authority) By Seller Yes * NGT approval needs to be provided bu the Govt department if requried Yes * Generic Parameters Make and Model of Vacuum Pump PARTISOLI * Make and Model of PTO HAIWA * Make and Model of DAWTY * 2/7 Hydraulic Motor Make and Model of Hydraulic Pump DAWTY * Make and Model of Suction Hose ITALIAN * Vehicle Chassis Make and Model TATA407 * Chassis Model Number NA * Chassis Type Medium Motor Vehicle Medium Motor Vehicle Type of Fuel Diesel Diesel Chassis Gross Vehicle Weight 4850 More than 4850.0 Or higher Kerb Weight 2170 * Pay Load Capacity (Tonne Load) 2.68 More than 2.68 Or higher Vehicle Emission Compliance BS-IV BS-IV Max Engine BHP 53 More than 53.0 Or higher Engine Torque Max@rpm 200 More than 200.0 Or higher No of Speed Forward Gears 5 More than 5.0 Or higher Gradeability of Vehicle (%) 26 More than 26.0 Or higher Wheel Base 2654 More than 2654.0 Or higher Engine Aspiration System Turbocharged Intercooler * Mount Type Truck Mounted Unit * Fuel Tank Capacity 60 More than 60.0 Or higher Constructional Parameters Capacity of Split Shaft PTO of the vehicle (kgm) 250 More than 250.0 Or higher Overall Length 4689 * Overall Width 1870 * Equipment Length 1500 * Equipment Height 1250 * Equipment Rear Over Hang Yes Yes If Yes
RequiredDeclare Equipment Rear Over Hang 200 * 3/7 Type of Front Axle and Suspension System NA * Type of Rear Axle and Suspension System NA * Derrick Arm Available No No Vacuum Pump - Rotary Vane/Sliding Vane Yes * Type Of Cooling Liquid Cooling * Vacuum Pump Flow (cum/hr)as per IS 13496 to be declared 0.35 0.35 Vacuum Pump Power (hp@rpm) 8 More than 8.0 Or higher Vacuum Relief Valve Size 1.5 * Vacuum Suction Depth 8 More than 8.0 Or higher Suction Hose - Lightweight
Requiredheavy duty
Requiredreinforced
RequiredPVC along with quick connect coupling arrangement Yes * Suction Hose Internal Diameter 85 85.0 Suction Hose Length 80 * Number of Suction Hose (Nos) 5 * Safety Equipments NA * Silencer/Filter(Micro Strainer) Yes * Exhaust Silencer and injection cooling air Inlet Silencer/Filter Yes * Blower Outlet and Air- Exhaust Silencer Yes * Check valve Yes * Vacuum Limitation Valve Yes * Drain Off valve Yes * Total Tank Capacity (sludge tank+water tank) 2000 2000.0 Water storage Tank Capacity 500 500.0 4/7 Sludge Storage Tank capacity 1500 1500.0 Thickness of tank plate 6 * Material of tank Mild steel(Grade-A) conforming to IS 2062 latest * Surface preparation and finish of tank's Exterior - sanded prior to spray painting and spray painted with two coats of superior quality anti corrosive primer and two coats of enamel metal paint Yes * Surface preparation and finish of Tank's Interior - clean water two coats anti corrosive primer & two coats of grey enamel paint & Sludge shall be with two coats of epoxy paint to resist corrosion Yes * Provision for locking and unlocking arrangement of rear gate of tank
Requiredto be operated hydraulically for quick tipping and cleaning Yes * Hose Reel Drive operated by hydraulic motor Yes * Dished Head Yes * Tank Rear Door Opening by hydraulic system Yes * Reinforcement rings in pipes No * Hydraulic Pump Type Gear Type * Water Level Indicator Type (with safety coverage) 2 * Water Level Indicator Nos 2 * Thickness of Cover for Engine
RequiredPump and Hose Reel compartment 3 * 5/7 Material of Cover for Engine
RequiredPump and Hose Reel compartment Galvanised IronSheet * Full bore Quick Acting Valves in the sewage path Yes * Air Pumps to safeguard the pump from overloading Yes * Make and Model of Air Pump NA * Sludge Trap between the Air Pump and the Tank Yes * Float cut out valve to seal the pump suction line Yes * Lubricating system for reducing friction loss Yes * Three sewer cleaning nozzles with varying rearward angles Yes * One nozzle extension for easy fixing of the hose and the nozzle Yes * Two stop tank strainer elements Yes * Two sets of operation and service manuals and spare parts lists Yes * Hose guide Yes * Counter Yes * Suction hose 30mtr Yes Yes Set of Spares Yes * Performance Parameters Warranty Time 24 More than 24.0 Or higher Warranty Distance 10000 * No of Free Service (Minimum 3 per year) Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents