| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹45.3 LAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L-1 | Accepted-AOC Being L-1 Bidder | |
| 2 | L-2₹48.1 L+₹2.8 L (6.18%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L-2 | Rejected-Finance Other than L-1 Bidder | |
| 3 | L-3₹52.6 L+₹7.3 L (16.0%)Rejected-Finance BHANGARMATH THAKURANICHAWK PO SAMABAYPALLY BALLY HOWRAH 711205 | HOWRAH | HOWRAH | WEST BENGAL | 711205 | L-3 | Rejected-Finance Other than L-1 Bidder | |
| 4 | L-4₹53.1 L+₹7.8 L (17.2%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-4 | Rejected-Finance Other than L-1 Bidder | |
| 5 | L-5₹53.2 L+₹7.9 L (17.4%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L-5 | Rejected-Finance Other than L-1 Bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
26 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIRS/ MAINT OF STREET LIGHT FLOOR LIGHTS, GARDEN LIGHT, POST TOP AT COMD HOSP (EC) AND II LINE AREA UNDER GE (A) KOLKATA
2024_MES_677942_1
GE/ALP (8360B) KOLKATA OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Alipore) Kolkata
CLASS D AND CATEGORY b(i)
9 documents required · 9 mandatory
₹500
Garrison Engineer, Alipore
₹84,000
Yes
GE (Alipore) Kolkata
31 Dec 2024
4 Oct 2024
2 Nov 2024
4 Oct 2024
26 Oct 2024
19 Oct 2024
4 Oct 2024 - 11 Oct 2024
14 Oct 2024
Amount
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make: Havells (Cat No EBDURAOMNIPLUSSL70WLED757SASY TOPC)/ Phillips/ CROMPTON.
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make: HAVELLS (EBDURAOMNIPLUSSL120WLED757 SASY TOPC)/ Phillips/ CROMPTON.
Material and labour for replacement of thermoplastic cable junction box with knockouts for cable entry upto 25 sqmm including minimum 4 terminals for terminating cables including fixing arrangement by carefully cutting the bases of pole or post top lantern or other wise as indicated all as specified and as directed. Make: Hensal (Cat No: K 9255)/Sintex/C/S.
Supply and fixing Steel tubular swaged poles complet with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres long)
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp Make: Havells (Cat No.JETAADORNNXTFLS70WLED757P60 DTOTG)/ PANASONIC/ Crompton/Philips.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp Make: Havells (Cat No. JETAADORNNXTFLS100WLED757P60 DTOTG)/ PANASONIC/ Phillips/Crompton.
Supply and fixing Unique modular LED flood light 400 watt 230 V AC made up of pressure die cast aluminium housing outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp Make Crompton (Cat No. LFLPI-400-CDL/60-M)/ Havells/ Panasonic/ Philips.
Supply and fixing for replacement of LED 9 W decorative bollard with victorian design with opal acrylic diffuser and IP 65 protection complete with PCC work (1:2:4) of adequate size for installed of bollard fitting complete all as specified and as directed. Make :- Bajaj (CP No BGBOM 605 9W LED WH)/ Havells/ Panasonic/ Philips.
Labour only for checking of unserviceable street light fitting over poles, finding of faults and repair/ replacement of unserviceable spares like lamp, holder, ignitor, ballast, connector block etc and making the light functional in all respect including necessary tools reqd for repair all as specified and as directed. [Note: - (i) All the spares required for repair will be measured and paid under separate item of this schedule as 'Supply only'. (ii) Necessary tools required for repair deemed to be included in the quoted rate. (iii) Cost of short pieces of copper conductor for internal wiring in between holders, ballast, ignitors and other accessories housed in the same light fitting deemed to be included in the quoted rate]
All as per Item Ser No 9 here in before but for post top lanterns, outdoor bracket lights and flood lights
Supply only driver for LED luminaires upto 24 watt Make: Philips (driver type: BRP320 POT Spare LED Driver)/ Bajaj/ Crompton Greaves/ Havells.
Supply only driver for LED luminaires upto 36 watt Make: Philips (driver type: BRP409 Spare LED Driver) / Bajaj/ Crompton Greaves/ Havells.
Supply only driver for LED luminaires upto 75 watt Make: Philips (driver type: XITANIUM 75W 0.70A 1-10V INT-Y SXT) / Bajaj/ Crompton Greaves/ Havells.
Supply only driver for LED luminaires upto 150 watt Make: Philips (driver type: SPARE DRIVER XTE 150W 700 mA NTC)/ Bajaj/ Crompton Greaves/ Havells.
Material and labour LED Post Top Lantern 40 watt for 360O indirect lighting with glare free milky white side covers and IP65 grade protection including taking out of old light fitting all as specified and as directed. Make:Cat No: LPTO-40-CDL/M Crompton Greaves / Philips/ Bajaj/ Havells
Supply & fixing BAMBOO LED BOLLARD,Aluminium landscape IP 65 luminaire for diffuseed lighting with high power LED as light source. complete with all accessories, prewired and flexible wire twin core from terminal block and mounted on cement concreet foundation not less the 1 feet hight. complete all as specified and directed. Make-HAVELLS (Cat No- BAMBOOBL8WLED830SSYMTOPCM) /Philips/ Magik.
Supply and fixing in repairs design from the renaissance era yet with a modern look using new generation technology in 35W LED to enliven outdoor areas in perfect synchronization with functionality and aesthetics. IP66 Family of post top lantern designed to complement the geometry of the area including all accessories and connection complete all as specified and as directed. Make :- Havells (Cat Part No VICTORIAPT35WLED757PSY MTOTG)/ Crompton/Bajaj.
Supply and fixing in repairs aesthetically designed decorative hot dipped galvanised mild steel step 3M pole with grey powder finish. Compatible for all post top range. Window - Plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole including necessary PCC work complete all as specified and as directed. Make: Havells (Cat Part No DECO POLE 3M TOP dia 76mm)/ Crompton/ Bajaj.
Material and labour for Cement concrete type B1 (1:2:4) with 20 mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges
Material and labour for Galvnized steel tubluler light gead 40 mm pipe not less then 1.5 mtr suitable for street light bracket with all fixing arrangment all as specified and as directed.
Cleaning roof top of MES Installations with wire brush including removing of vegetations
Material and labour for bush cutting and cleaning of area in and around of E/M installations for the following areas: -
Main Receiving Station No 1
Main Receiving Station No 2
Sub-Station No 1
Sub-Station No 2
Sub-Station No 3
Sub-Station No 4
Sub-Station No 5
Sub-Station No 6
Sub-Station No 7
Sub-Station No 9
Sub-Station No 10
Servicing of Air Circuit Breaker AC three phase 415 volt, 50 Hz, 800 Amp to 1600 Amp including taking shut down and racking out the complete assembly, cleaning of all the parts by air blower, applying suitable chemical (CRC), greasing of all moving parts, checking resistance of all the contact points and refixing the same in original position all as specified and as directed.
Taking out of old PCC / steel tubular pole of 9 mtr height and installing the pole in other location all as specified and as directed [Note: Earth work and PCC will be measured and paid under separet item of this schedule]
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in any type of soil
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil
Material and Labour for dry river Sand filling in trenches including punning down consolidation in soft/ loose soil
MMaterial and Labour for tubes, 'light grade', galvanised, with all fitting; laid in trenches for cable/ earth lead protection of the following sizes: -
80 mm dia nominal bore
50 mm dia nominal bore
40 mm dia nominal bore
Material and labour for brick protection of cables in trenches with old size sub-class 'B' bricks
Relaying of old useful bricks as retrieved during taking out of old LT UG cable all as specified and as directed.
Material and labour for cutting of existing bituminous metal road for laying of cables including demolition of road surface, excavation from bottom level of road upto a depth of 0.55 m from road surface and returning filling of excavated earth and making good the road surface with PCC type C2 (1:3:6) with 40 mm graded stone aggregate upto a depth of 10 cm from road surface and removing of excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil all as specified and as directed. [Note: Laying of cable/ protection pipe will be measured and paid under separate item of this schedule]
Taking out of old LT UG cable 1100 volts grade all as specified and as directed for the following size of cables
400 sqmm 3.5 core and above
240 sqmm 3.5 core
185 sqmm 3.5 core
95 to 120 sqmm 3.5 core
50 sqmm 3.5 core
25 to 35 sqmm 3.5 core
10 to 16 sqmm 2/4 core
Supply and Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade all as specified and as directed for the following size of cables: -
400 sqmm 3.5 core
240 sqmm 3.5 core
185 sqmm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
10 sqmm 2 core
Material and labour for MCCB 3 pole, 415 V, upto 100 Amp, 36 kA including taking out of old one all as specified and as directed. Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB 3 pole, 415 V, upto 250 Amp, 36 kA including taking out of old one all as specified and as directed. Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB 4 pole, 415 V, 100 Amp, 36 kA including taking out of old one all as specified and as directed. Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB 4 pole, 415 V, 125 Amp, 36 kA including taking out of old one all as specified and as directed. Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB 4 pole, 415 V, 160 Amp, 36 kA including taking out of old one all as specified and as directed Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB 4 pole, 415 V, 250 Amp, 36 kA including taking out of old one all as specified and as directed. Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB 4 pole, 415 V, 400 Amp, 36 kA including taking out of old one all as specified and as directed. Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB 4 pole, 415 V, 63 Amp, 25 kA including taking out of old one all as specified and as directed. Make :- L&T/Indo Asian/Havells/Seimens/Legrand.
Material and labour for MCCB Spreader Terminals 2 Pole including taking out of old one all as specified and as directed. Make: L&T (Cat No:CM9909640000)/ Legrand/ Schnieder/ ABB
Material and labour for MCCB Spreader Terminals 3 Pole including taking out of old one all as specified and as directed. Make: L&T (Cat No:CM9909640000 )/ Legrand/ Schnieder/ ABB
Material and labour for MCCB Spreader Terminals 4 Pole including taking out of old one all as specified and as directed. Make: L&T (Cat No:CM9909640000)/ Legrand/ Schnieder/ ABB
Cable jointing kit for LT XLPE Cable (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size upto 90 sqmm
Cable jointing kit for LT XLPE Cable (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 240 sqmm
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm
M & L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes for use as duct covers as per existing size including taking out of old one all as specified and as directed.
Maintenance of LT distribution panel after taking proper shutdown including cleaning of enclosure with dry cloth and cleaning of contact points with suitable electrical contact cleaning agent and clean dry cloth, checking of tightness of all the contact points, replacement of defective/ burnt out lugs and bolts & nuts and reporting of major defects if any found during maintenence all as specified and as directed for the following: -
LT panel with Incoming ACB upto 1600 Amp 1 No and outgoing MCCBs upto 630 Amp 4 pole upto 8 Nos and Changeover if any
LT panel with Incoming MCCB upto 800 Amp 1 No and outgoing MCCBs upto 400 Amp 4 pole upto 8 Nos, all MCBs, Changeover if any
LT feeder pillar box with Incoming MCCB upto 400 Amp 1 No and outgoing MCCBs upto 250 Amp 4 pole upto 8 Nos and all MCBs
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required (32x6)mm galvanised iron strip including taking out of old strip all as specified and as directed.
Material and Labour for Test point terminal block made of gun metal or phosphorus bronze size (75x75x25)mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw including taking out of old one all as specified and as directed.
Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size (32 x 6) mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
All as per item No 54 here in before but with GI wire of 4mm dia as earthing lead
Cable Iugs,aluminum tubular as per following :
Material and labour for Painting of LT Pole after preparation of old painted surface and painting with two coats of aluminium paint for the entire pole and yellow and black colour synthetic enamel paint in 2 Nos alternate layers of 32 mm high at the bottom of each pole including taking proper precautionary measure for disconnecting electric supply and wright existing ppole Number with white enanamel synthetic paint all as specified and as directed.
Material and labour for Painting of pipes of Post Top Lanterns after preparation of old painted surface and painting with two coats of synthetic enamel paint of approved colour including taking proper precautionary measure for disconnecting electric supply all as specified and as directed.
Material and labour for Painting of LT Panel / MES equipment after preparation of old painted surface and painting with two coats synthetic enamel paint With spray painting of approved colour including taking proper precautionary measure for disconnecting electric supply all as specified and as directed.
Supply and fixing insulating LT synthetic rubber mat of size 1 m x 2 m x 2 mm thick class A as per IS: 15652 (2006) complete all as specified and directed.
Taking out cable loop after cable ends from panels, cutting/removing heated cable ends with burnt lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable around for cable size 35 to 240 sqmm.
Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all three phase , checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that is nearly balanced in all the three phase complete all as specified.
Supply only in replacement pole mountable (Timer switch for street lights) sensor based, astronomical and type timer with Nature switch-02, power contactor for load switching, MCB, and terminal block, including complete with mounting brackets, cable glands, openable door with lock and key. The enclosure made of UV stablizer, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor. Model/Make No:- SWADEEP-02 EC 5 KW 3P (Three phase)/ L&T/ABB/Legrand.
Supply only Astronomical Digital Time Switches complete all as specified and as directed. Model/Make No:- Havelle CP No DHTQB01016 or equivalent in L&T/ABB/Legrand.
Supply,install,test and commissioning of In door type LT Feeder piller box made out of 2.0 mm thick CRCA sheet out door type , CPRI Approved ,totally enclosed weather dust and vermin proof as per IS with front and rear 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of (50 X 50 X 6) mm angle iron grouted at Floor above 30 cm from ground level Comprising the following includint taking down old unserviceble feeder piller box , all as specified and as directed. Note: Cost includes necessary internal wiring for meters , CTs, indication lamps,etc and Rigid bus bar connections from bus bar to MCCB terminals connection Bus to MCCB/MCB connections. Incoming (i) MCCB, 4 POLE, 160 Amps, KA. (ii) Multi function meter 01 Nos CT as per incoming rating . (iii) LED type Indicating lamps -03 Nos [Make : C& S/ Neptune / L&T / Vaisnavo] Outgoing (i) MCB TPN 40 Amps, 10 KA 12 Nos
Taking out interlocking paver blocks of any description and staking it properly at site for carring out cable trenches and connected E/M works and refixing of old stacked interlocking paver blocks after at same site after completion of E/M works and including all extra handling and removal and disposing off rubbish out of MoD land complete all as specified and directed.
Surfaces dressing n.exc 15cm deep and getting out in loose/soft soil complete all as specified and directed.
Removing excavated material outside MoD land n. exc. 1.50km and depositing where directed complete all as specified and directed.
M & L for 25mm sand cushion under paver block or interlocking tiles floor including watering and consolidation complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for 60mm thick coloured machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 M -40 Grade with grey cement and no pigment complete all as specified and directed.
KWALITY CONSTRUCTION (BID ID -3149501)
DUTTA & DUTTA (BID ID -3148518)
M/S J S ENTERPRISES (BID ID -3149316)
ARATI TRADING CO (BID ID -3150488)
DILIP CONSTRUCTION (BID ID -3150518)
ROY CONSTRUCTION (BID ID -3148852)
JAGATMATA ENTERPRISE (BID ID -3149679)
GAYATRI ENTERPRISE (BID ID -3150187)
PINKY CO. (BID ID -3147730)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .