Loading…
Loading…
Tender Value
₹41.4 L
EMD Value
₹82,800
Closing Date
4 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT G
12 conditions · 1 needing a document upload
(i)For participating in tender for an electrical nature of work, the contractor shall have to possess valid Electrical License of appropriate voltage issued by any State Government under clause 45 of compilation of rule of Indian Electricity rules 1956 or as amended from time to time. Electrifications of 11 KV and above including OHE, "A" class electrical contractor license is essential. (ii) The license can be possessed with one of the partners or in his own name if sole proprietor. Firm should submit a self-attested copy of the electrical contractor license along with the offer, otherwise, the offer will be summarily rejected
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
13 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the Qualifying criteria mentioned in the tender document. It will not be obligatory on the part of tender committee to scrutinize beyond the submitted document of tenderer as far as his qualification for the tender is concerned. The railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
No post tender correspondence shall be entertained after closing of tender even Suo moto post tender letters of the tenderers shall be treated as null/void.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender . Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim what so ever will be entertained by Railway.
The tenderer should upload the documents carefully. The documents uploaded by tenderer should be clearly visible and in legible format.
Indian Railways Standard General Conditions of contract 2022 along with correction slips corrected up to date of closing of tender and the attached documents are part of the tender document.
The offers which are incomplete, without supporting documents, unsigned, conditional, will be summarily rejected.
As per letter No. 2022/CE-I/CT/GCC/Correspondence/ New Delhi, dated 14.05.2024 "On IREPS Module , a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by tenderer had been discontinued on IREPS"
Two miscellaneous Electrical work (i)ADEN (S) STA Construction of 2 unit RB II Qtr at PTWA station and 4 unit RB II Qtr at LGCE station under ADEN/S/STA sub division (ii)Construction of one additional room of 22 free bungalows and officer bungalow at Rail saurabh colony Jabalpur ADEN(HQ) JBP sub division
JBP-L-T-No-01-2026
JBP-L-T-No-01-2026
Open
Works - General
6 Months
Jabalpur, Madhya Pradesh
₹0
₹82,800
4 May 2026
11 Apr 2026
20 Apr 2026
138 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 15,32,335.51 | ||
| — | Item Breakup | for details. | — | ||
| LT outdoor panel (water proof) made/fabricated out of 1.6 mm MS sheet duly painted with powdercoated , IP-65, IK-09 having suitable copper bus bars with sleeves , indicating lamps, multifunctionmeter , Gland ,Lugs, Foundation , earthing , Door Lock arrangment, pad lock, suitable MS channel ,SWG wire etc. Incoming 100 A, 4 pole 25kA MCCB (2 nos, 1 as spare) and outgoing 5 x 40A 4 poleMCCB 25kA + 5 x 63A 4 pole MCCB 25kA. All the MCCBs shall be of legrand , ABB, L&T, Schnider,Hager,Simens make or equivalent.(Dismantling of existing panel, structre, disconnection , reconnectionof cable and released material tranported to nearest depot by contractor)Design of panel will beapproved by comptent authority before supply, | — | — | — | 2,71,361.61 | |
| — | Item Breakup | for details. | — | ||
| SDB for light and fan. TPN DB 4 way (8+12) IP-43 with metal door, with 32A TPN incomer and outgoing having 5 x 10A SPMCB and 5 x 6A SPMCB MCB make- Legrand, ABB, L&T, Schnider, Hager, or equivalent | — | — | — | 35,964.6 | |
| — | Item Breakup | for details. | — | ||
| SDB for Power. TPN DB 4 way (8+12) IP-43 with metal door, with ELCB, RCCB 63A TPN incomer and outgoing having 5 x 32ASPMCB and 5 x 20/16A SP MCB make- Legrand, ABB, L&T, Schnider, Hager, or equivalent | — | — | — | 42,966.24 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of 1 x 18/20W LED fittings 4 feet length. The fittings shall have to be erected by the contractor with all fixingaccessories/MS clamps, nuts bolts etc. as per requirement at site. | — | — | — | 5,728.08 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of Ceiling fan including electronic modular fan regulator, suitable down rod, Metalfan hook, Fan box flexible Pipe, with all necessary arrangement (BLDC, 5 star rated, 1200 mm Make- Atomberg,Usha, Bajaj,Havells or similar make) | — | — | — | 63,198.9 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of E/Fan 380mm sweep: fixing is to be done on already provided finished opening in the wall using required fasteners, their grouting and thenconnection is to be given from ceiling rose to this fan using cable of 1.5 sq. mm. size Make- Atomberg,Usha, Bajaj,Havells or similar make | — | — | — | 47,371.32 | |
| — | Item Breakup | for details. | — | ||
| Point Wiring: This includes provision of wiring with 1.5 sqmm copper stranded PVC insulated wire [ L & N and earth ]fromMDB/SDB/ Board to light & fan control board and provision of control switch on common light and fan control board , together withwiring from control board to ceiling rose and provision of ceiling rose , holder on board , coduit pipe ; with earth continuity wire; independent for each fitting. Cost of this item is inclusive of distributed cost of common board & wiring from MDB/SDB/Board to common board inaddition to items specifically mentioned Make- Legrand, ABB, L&T, Goldmedal, or simillar make | — | — | — | 46,513.6 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x2.5 sqmm FRLS copper wire inside PVC Casing capping / Concelead withrunning earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 2.5 sqmm with onewire of 1.5 sqmm for earth conn). | — | — | — | 51,840 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x4 sqmm FRLS copper wire inside PVC Casing capping/ Concelead with runningearth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of4 sqmm with one wire of 1.5sqmm for earth conn). | — | — | — | 54,801 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x 6 sqmm FRLS copper wire inside PVC Casing caping/ concelead with runningearth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 6 sqmm with one wire of 2.5sqmm for earth conn). | — | — | — | 51,678 | |
| — | Item Breakup | for details. | — | ||
| 16A & 6 pin socket point on separate circuit and board. Make legrand, ABB, L&T, Havells or equivalent. | — | — | — | 28,374.6 | |
| — | Item Breakup | for details. | — | ||
| 5 pin 5A on separate boards: wires shall run separate from SDB Make legrand, ABB, L&T, Havells or equivalent. | — | — | — | 14,453.4 | |
| — | Item Breakup | for details. | — | ||
| 6A 5 pin socket point on fan and light control board Make legrand, ABB, L&T, Havells or equivalent. | — | — | — | 3,836.4 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. : Fourmodule box of Havells, Bajaj , Anchor or equivalent | — | — | — | 1,244.28 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. : Sixmodule box of Havells, Phillips, Orient, Bajaj or equivalent. | — | — | — | 1,992.84 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. : Eight module box of Havells, Phillips, Orient, Bajaj or equivalent. | — | — | — | 3,815.85 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modularswitches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened atthe time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. :Twelve/Eighteen module box of Havells, Phillips, Orient, Bajaj or equivalent. | — | — | — | 7,648.08 | |
| — | Item Breakup | for details. | — | ||
| PVC conduit 25 mm dia as per IS-9537 (HMS) | — | — | — | 7,934.4 | |
| — | Item Breakup | for details. | — | ||
| Cutting of wall for insertion of 1" dia PVC conduit, fixing hardware's for fixing the conduit along with its supply and then replaster itwith cement and sand mixture and then painting with matching colour as per existing colour of the wall. Proper joints in pipes,bends/elbows/ junctions are to be provided as per site requirement | — | — | — | 47,343.6 | |
| — | Item Breakup | for details. | — | ||
| Concealed Wirings:25A/32A MCB and socket for air conditioner / Geyser/ Water cooler:(modular) Havells, Phillips, Orient, Bajaj,Crompton or equivalent | — | — | — | 41,716.44 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 36 W LED street light fittings suitable for 230V AC, 50 Hz comprise a single piece deepdrawn alluminium housing IP-65 colour temp 5500- 7000K with connection etc. with 1.5mtr GI pipe suitable fixtures and clamps etc. Havells,Phillips, Orient, Bajaj or equivalent. | — | — | — | 36,151.2 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of 4 mtrs octagonal pole of alongwith baseplate, foundation, earthing , 8 SWG GI wire and single/ double arms for holding fittings make- Bajaj,crompton, Surya, or simillar make Approval will be required by comptent authority before supply | — | — | — | 1,35,273.7 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of outdoor control box of 2A 230 V 3P Timelite Distribution Boards-Analog TimeSwitch IS/IEC 13949-26 Dimension LxWxH 9x4x7 CM make -L&T , ABB, Havells, legrand , HPL orequivalent. | — | — | — | 25,037.96 | |
| — | Item Breakup | for details. | — | ||
| Pipe earthing as per IS 3043 Supply of material for Earthing pit as per IS-3043, Erection includes excavation of earth, filling ofsalt, charcoal, B class GI pipewith funnel at top with castiron cover having handle and cement concrete chamber etc.as per IS latest withinscription ligibility of IR value on top of earth pit chamberwith serial no-etc.Then testing with earth tester. 8 SWG GI wire to be connected with the earth pit to the installation. | — | — | — | 25,280.3 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection of 8 SWG GI wire | — | — | — | 1,072.6 | |
| — | Item Breakup | for details. | — | ||
| Excavation of Cable trench in Cement Concrete and laying of cable, The cable shall be suppliedfree of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to thesite | — | — | — | 31,598 | |
| — | Item Breakup | for details. | — | ||
| Cable laying single in earth. This involves Excavation of 1000mm deep trench in soil/hardmurrum/tar road/below Railway track. After this the cable shall be laid and then both sides are to becovered with bricks. The rest of the trench to be refilled by sheaved earth. The cable shall be suppliedfree of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to thesite | — | — | — | 6,687 | |
| — | Item Breakup | for details. | — | ||
| Cable laying double in earth.(LT, HT both type) This involves Excavation of 1000mm deep trench in soil/hardmurrum/tar road/below Railway track. After this the cable shall be laid and then both sides are to becovered with bricks. The rest of the trench to be refilled by sheaved earth. The cable shall be suppliedfree of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to the site | — | — | — | 27,252.5 | |
| — | Item Breakup | for details. | — | ||
| Cable laying on wall /pole and other similar places fixing using MS flat [25x6mm.]clamps, nuts, bolts,screws or nails as per site requirement | — | — | — | 5,224.1 | |
| — | Item Breakup | for details. | — | ||
| Pucca Cable trench: Construction of cable trench and laying of UG cable in 700 mm deep cable trench made of RCC with MS channel . This includes supply of all materials erection, commissioning of cable & trench etc. The laying of cable from transformer to the panel board shall be done in cable trench made of RCC complete with excavation of soil, construction of RCC wall for a height of 700 mm and inside width of 500 mm. Both wall and bottom surface of inside trench shall be finished with a fine coating of plaster. This constructed cable trench shall be covered with concrete slabs each of requisite width and a length of 1m. | — | — | — | 27,760.8 | |
| — | Item Breakup | for details. | — | ||
| Cable route marker; Supply & providing cable route markers marked with L.T./H.T. cable as required as perrelevant IS & at every turning points/road crossings and at 20mtrs distance | — | — | — | 934.05 | |
| — | Item Breakup | for details. | — | ||
| Provision & laying of HDPE pipe 4" dia in tack crossing including jointing etc. with requiredaccessories etc | — | — | — | 1,54,657.5 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of 50 mm dia GI pipe B class. | — | — | — | 3,017.4 | |
| — | Item Breakup | for details. | — | ||
| — | Item Breakup | for details. | — | ||
| — | — | — | 1,102.62 | ||
| — | Item Breakup | for details. | — | ||
| Meter panel box with outdoor light control DBs (4 meter outgoing) | — | — | — | 64,595.42 | |
| Supply Erection Commissioning and Testing of 25 liter water heater 5 star rated make- Bajaj, Havells, orequivalent Sample will beapproved competent authority before supply.make- Crompton, V-Guard, Havells, Haier or equivailent . Smaple spec. will approved comptent before supply | — | — | — | 1,15,681.68 | |
| — | Item Breakup | for details. | — | ||
| Supply of GI perforated cable tray of size 200 mm x 50 mm x 2 mm Thick | — | — | — | 27,275.2 | |
| — | Item Breakup | for details. | — | ||
| Laying of GI perforated cable tray of size 200 mm x 50 mm x 2 mm Thick | — | — | — | 2,727.6 | |
| — | — | — | 26,08,357.13 | ||
| — | Item Breakup | for details. | — | ||
| Supply, fabrication, erection, testing & commissioning of LT power panel 440V outdoor type made of 2mmMS sheet with cover & locking arrangement duly painted with two coat of red oxide & powdercoating (7 process) with requiredaccessories for fixing as per Railways specification attached. The panelshall have Copper Bus Bar of suitable size.(A). Incomingfeeder: (2 x 400 Amps MCCB (B) Out goingfeeder : 2x200 Amp MCCB, 3x100 Amp MCCB and 3x63 Amp MCCB including MS channel, Gland, lugs,Suitable Foundation, Earthing,GI Strip, Sleeves, MCCB, digital meter, Make- ABB, Legrand, L&T, Hager, Schnider, or simillar make | — | — | — | 4,12,440.3 | |
| — | Item Breakup | for details. | — | ||
| Supply erection and commissiong of SDB for light and fan. TPN DB 4 way (8+12) IP- 43 , IK-08 withmetal door, earthing, isolated nuteral bar with ELCB, RCCB , 32A TPN incomer and outgoinghaving 5 x 10A SPMCB and 5 x 6A SP MCB make- L&T, Legrand, ABB or equivailent | — | — | — | 1,16,924.28 | |
| — | Item Breakup | for details. | — | ||
| Supply & Erection of C/Fan, High energy efficient 5 star rated BLDC fan with regulator, having sweep size 1200mm, operating voltage 140-270, maximum hourly power consumption of 32W with double ball bearing and Airflow minimum CMM220, suitable down rod , Metal fan hook, flexible Pipe, with all necesaary arangment make- Atomberg, Havells, CG or equivailent,Sample will be approved comptent authorty before supply | — | — | — | 1,54,486.2 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of T-5 fittings/Batten type 4 feet T-8 LED / 4feet led retrofit fitting with LED tube lamp 20 W Make- Havells, bajaj, CG, or Simillar Sample will be approved comptent authorty before supply | — | — | — | 10,189.08 | |
| — | Item Breakup | for details. | — | ||
| Point Wiring : This includes provision of wiring with 1.5 sqmm copper starnded PVC insulated wire [ L & N and earth ]from MDB/SDB/ Board to light & fan control board and provision of control switch on common light and fan control board , together with wiring from control board to ceiling rose and provision of ceiling rose on board ; with earth continuity wire; independent for each fitting. Cost of this item is inclusive of distributed cost of common board & wiring from MDB/SDB/Board to common board in addition to items specifically mentioned Make- Legrand, L&T, ABB, or equivailent | — | — | — | 80,753.2 | |
| — | Item Breakup | for details. | — | ||
| Circuit wiring with 2x2.5 sqmm copper multistranded wires (SDB panel to SB) and copper wire 1.5 sqmm green in clour for earth(2x2.5 Sq mm +1x1.5 Sq mm) Make- KEI, RR Cable, Finolex , Polycabe or simillar make | — | — | — | 23,001 | |
| — | Item Breakup | for details. | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AC08to10.pdf
ATTACHMENT
01-2026tenderdoc.pdf
ATTACHMENT
ac11.pdf
ATTACHMENT
Allcorrectionslip.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .