| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | ₹7.4 L | L1 | Accepted-AOC Accepted L1 |
| 2 | L2₹8.4 L+₹1.0 L (14.0%)Rejected-AOC | ₹8.4 L+₹1.0 L (14.0%) | L2 | Rejected-AOC Rejected L2 |
| 3 | L3₹9.7 L+₹2.3 L (30.4%)Rejected-AOC | ₹9.7 L+₹2.3 L (30.4%) | L3 | Rejected-AOC Rejected L3 |
| 4 | L4₹9.8 L+₹2.4 L (32.9%)Rejected-AOC | ₹9.8 L+₹2.4 L (32.9%) | L4 | Rejected-AOC Rejected L4 |
| 5 | L5₹10.1 L+₹2.7 L (36.2%)Rejected-AOC | ₹10.1 L+₹2.7 L (36.2%) | L5 | Rejected-AOC Rejected L5 |
Tender Value
₹10.6 L
Closing Date
18 Oct 2023, 1:00 pmClosed
Lt Col Jyoti Kumar
Govt of India Min of Def Defence RnD Organisation Estate Management Unit Armament Estate Pashan Pune 411021
REPAIR/ RENOVATION OF BASKET BALL COURT FLOOR AT COLONELS POINT AREA NEAR HEALTH CLUB, ARMAMENT ESTATE PASHAN, PUNE
2023_DRDO_773656_1
EMU(RnD)/ENQ/REPAIR/RENOVATION OF BASKET BALL
Open Tender
Civil Works
Works
270 days
Pashan
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
Estate Management Unit (RnD) Pashan, Pune
Exempted
31 Oct 2023
27 Sept 2023
19 Oct 2023
27 Sept 2023
18 Oct 2023
27 Sept 2023
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge:
All kinds of soil
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement oncrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm ncluding strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Made of G.I. wire of dia 4 mm
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using tructural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar orks
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
One or more coats on old work
Cast Iron garden bench waterproof polish for outdoor and indoor capacity 3 seater with back and arm rest.
Basket ball board of size 1800mm(L) x 1050mm(W) x 12mm(Thickness) with non reflective laminated sefty glass or tempered glass/ transperent glass board.
Supply, installation, testing and commissioning of following LED fittings complete with electrical connections, fixing & mounting accessories. All the fittings to be supplied with lamps.
250 W LED Flood Light IP 65 (Make Wipro, Bajaj, Crompton or Equivalent)
Supplying, laying and comissioning of 1.1 KV grade XLPE insulated, 4 Core 6 sq. mm Aluminium Armoured Cable in under ground including excavation of earth etc as per standard specification of laying of under groung cable.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
Supplyirig and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing! MCB DB complete with connections, testing and commissioning etc. as required.
Archana Enterprises
MATHA ENTERPRISES
BHAVA ENGINEERS
SMS ASSOCIATES
VISION ASSOCIATES
NIMMA NARAYAN ENGINEERS & CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .