Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹41.2 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹43.5 LRejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | Rejected-Technical H NO 502 B BLDG WELWORTH PARADISE PANCARD CLUB ROAD OPP MARBEL SOCIETY NEAR DHANKUDE VASTI BANER PUNE MH 411045 | PUNE | PUNE | MAHARASHTRA | 411045 | - | Rejected-Technical DUE TO NEGATIVE REMARK IN WLR |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
7 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
ADDN/ALTN/EXTN OF ANNEXE OF BLDG NO.345 AND CERTAIN SANCTIONED WORKS AT 26ED, GV CAMP, SDI, ASTE UNDER GE (AF) MARATHAHALLI BANGALORE
2025_MES_699327_1
8749/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹94,000
Yes
19 Jun 2025
25 Feb 2025
12 Apr 2025
25 Feb 2025
7 Apr 2025
24 Mar 2025
Amount
M & L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in hard/dense soil complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D 2 (40 mm graded crushed stone aggregate) as filing in mass concrete complete all as specified and as directed.
Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:6, complete all as specified and as directed.
M&L for Providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed)1:3:6 type C-1(20mm graded aggregate) setting in mortar 1:6,complete, in walls complete all as specified and as directed.
M&L for 40mm thick cement concrete 1;2:4 TypeB-0 (12.5 mm graded aggregate ) Damp proof course to horizontal or vertical surfaces including necessary formwork with WPC complete all as specified and as directed.
Supply only Liquid water proofing compound.
M&L for hard core of broken stone gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered andrammed to a true surface complete all as specified and as directed.
M&L 75 mm thick PCC 1:4:8 type D2 using (40 mm graded crushed stone aggregate) in sub floor all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate in floor all as specified and directed.
M&L for PCC 1:3:6 type C2, 40 mm graded aggregate as in plinth protection (75 mm thick) finished even and smooth with using extra cement.Note: Joints of the plinth protection should be filled with sand and bitumen mortar and sealed with bitumen grading.
M & L for rendering 10mm thick in cement mortar 1:6 on brick and concrete surfaces of walls.finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 15mm thick in cement mortar 1:4 on brick and concrete surfaces of walls in two layers, finished even and smooth without using extra cement incl. WPC complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc. 0.11sqm and n.exc. o.18 sqm in floor set and jointed in cement clurry and pointed with coloured cement to match with coloured tiles over and including cement screed or bedding layer of cement mortar 15mm thick in 1:4 complete all as specified and as directed.
M&L for glazed ceramic coloured wall tiles of 350X 250X7mm/450X350X7mm as in dados, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 10mm thick cement plaster in 1:3 as backing coat complete all as specified and as directed.
M&L for Rotational moulded polythylene PVC water tanks of 500 liters capacity ISI MARKED(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
S&F of 20 mm dia(OD) CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting fixed complete to walls, ceiling or laid in floors etc including short length , with all pipe fittings such as ends, elbow, unions, tee, reducing tees etc. including taking down all as specified and directed
S&F of 25 mm dia(OD) CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting fixed complete to walls, ceiling or laid in floors etc including short length , with all pipe fittings such as ends, elbow, unions, tee, reducing tees etc. including taking down all as specified and directed
S&F 15 mm bore Chromium plated fancy type bib taps with wall flange, cast copper alloy with round operating knob screwed down high pressure, screwed for 15mm bore iron pipe complete all as specified and directed.
S&F 15mm bore pillar taps fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in stop valves/angle cocks or two way angle cock cast copper alloy concealed type long body with round operating knob chromium plated screwed down high pressure, screwed both ends for 15 mm bore iron pipe or brass ferrule complete all as specified and as directed.
M&L for Concussive push button CP taps of15mm dia cast copper alloy,screwed for iron pipe and fixed.
S&F 20 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F 25 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F in 25 mm bore ball valves, high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210gms) complete all as specified and directed.
S&F in CP waste coupling of 32 mm dia (half or full thread) complete all as specified and directed.
S&F CP grating 100mm made out of stainless steel complete all as specified and directed.
S&F in PVC connection pipe 15mm size and 600 mm long with two PTMT nuts at each ends with rubber washer complete all as specified and as directed.
Supply only Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
S&F soap dish (Any Type) fixed to wall with brass chromium plated screws complete all as specified and directed.
S&F for PVC low level flushing cistern, white, 10 Ltrs capacity complete with all internal accessories & fixed to wall & making good to wall surfaces incl. taking down existing flushing cistern complete.
S&F in of CP Health faucet (hand shower) complete set with 1.5 mtr long pipe and fittings complete all as specified and as directed.
S&F for PVC waste pipe, 32 mm dia, 750mm long, suitable for Kitchen sink/WHB,fixed in repairs all as specified and as directed.
S&F Vitreous China wash down water closet (EWC) pedestal pattern white complete as fixed in repairexcluding flushing cistern and flush pipe and trap white including fixing bolts,WC seat cover of fixed with aluminium or ms chromium plated complete all as specified.(seat cover shall be measured and paid seperatly)
S&F in Vitreous China wash hand basin, angle back 550 x 400mm white excluding taps, waste chains and plugs and porcilain stopper but including bracket
S&F for Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white minimum),with grating and union for discharge pipe (excluding flushing cistern, flush pipe) complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall complete all as specified and directed
S&F 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall complete all as specified and directed
S&F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed
S&F 75 mm bore PVC (SWR) bends of any radius with duck foot or heel rest fitted with oval access door complete all as specified and directed.
S&F 20 mm dia D type CP towel rail 600 mm long between flanges complete all as specified and directed.
Supply and fixing Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube in openings all as specified .
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site all specified and as directed.
Supply and fixing 100 mm long butt hinges, extruded aluminiun alloy with galvanised mild steel himges, anodised and fixed.
Supply and fixing 150 mm long aluminium, anodized barrel tower bolts of extruded section all as specified
Supply and fixing 150mm long extruded alluminium alloy handle, cast type, anodized all as specified
Supply and fixing 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F Aluminium powder coated grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standared section and fixed to the existing window frame with CP brass /stainless steel screws @ 200mm c/c, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all comnplete as per requirement and direction .
Supply only 3.00 mm thick figured glass pin head type obscured or frosted on one side and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed
Supply only Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Anodised aluminium snap grid frame work Size of grid 605 x 605mm for false ceiling all as specified and as directed by Engineer in charge
S & F for4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out as in hard soil complete all as specified and as directed.
M&L for Heavy duty coloured Chequered cement concrete tiles 30cm x30cm x 25 to 30mm thick,laquered finish type set, jointed and pointed in neat cement slurry with gray cement pigment cement ang pigments. in floors over and Including 20mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over a coat of zinc oxide including preparation of new steel surfaces not otherwise described, over 10cm width or girth complete all as specified and as directed.
M & L for preparating surfaces plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified & directed by .
M & L for preparating surfaces plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified & directed
M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm each complete all as specified & directed.
M & L for Removing excavated Soil to a distance exc. 1.50km out side MD Land and depositing complete all as specified & directed.
Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
Supply, laying riddled earth soil conforming to IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
Supply only Bricks for protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
Supply and fixing of GI tubing, light grade, 100 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete all as specified and directed.
Supply, laying testing and commissioning LT, XLPE insulated , armoured,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3½ core connected with suitable lugs including taking out the existing unserviceable cable complete all as specified & directed .
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure.
Taking down outdoor Feeder panel of any size with MCCB / changeover type complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of outdoor type cubicle panel board suitable for 3 phase 4 wire 415 V, 50 Hz and tested at CPRI for 415 volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shared having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS : 8623/93 comprising. The outer shell shall be made out of 3 mm thick CRCA sheet and MS angle section 40x40x6 mm base frame factory fabricated with front openable, double door system lockable/ open able. The bottom of the outer shell contains a detachable plate having size with glands. The outer shell shall be mounted on stand having zine coating not less than 80 microns. Provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP - 54. Inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, TPN alluminum bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB.
The TPN bus bar shall be insulated with colour coded heat shrinkable sleave. All control wires shall be with 2.5 sqmm multi strand copper conductor and shall be propely bunched, tied, ferruled for proper identification and crimped with adequate size of lugs all as specified and directed by Engr in charge. INCOMING (a) MCCB 200 Amps 35 KA - 02 Nos. (b) Intelligent AC digital display three phase LCD ammeter 0 to 630A and voltmeter 0 to 500V with CT. (c) Indication lamp RYB/RRR-set of 03 -01 No. OUTGOING (a) MCCB 4 pole 125 Amps 25 KA 415 Volt - 4 Nos (b) MCCB 4 pole 63 Amps 25 KA 415 Volt - 3 Nos (c) MCCB 4 pole 32 Amps 16 KA 415 Volt - 2 Nos (d) Changeover of capacity 4 Pole 200 Amps - 1 No (e) Spare pocket for provisioning of MCCB
M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.
Supply and fixing cable tray for cable laying of size 20 cm x 5 cm complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in foundations for filling and mass concrete complete all as specified and directed.
Taking down/shifting of Smoke detector / Heat detector from false ceiling at Bldg No 345 from first floor AF Net section and keeping in safe custody, refixing the same after new false ceiling including connection from detector to panel at Bldg No 345 ground floor at Hardened shell room complete all as specified and directed by Engr-in-charge
Taking down/ shifting of Manual call point from walls at Bldg No 345 from first floor AF Net section and keeping in safe custody, refixing the same after new false ceiling including connection from MCP to panel at Bldg No 345 ground floor at Hardended shell room complete all as specified and directed by Engr-in-charge
S& F Armoured shielded, sheathed and twin twisted wires inside the armoured cable, 1100 V grade with copper conductor upto Fire alarm panel complete with fixing accessories such as spacer plates saddle/wall clips etc of size 1.5 sqmm 02 core complete all as specified and as directed.
Taking down / shifting of Fire supression system of 2.5 Kg of CO2 gas incl accessories and keeping in safecustody, refixing the same after new false ceiling work at Bldg No 345 ground floor at Hardened shell room , if additional gas leakage or low at the time of execution then surpression system installed after filling the gas is deemed to be included in the quoted rates complete all as specified and directed by Engr-in-charge
Dismantling of Brickwork or stone/boulder masonry, built in Cement mortar/cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M&L for RCC (Nominal mix), 1:2:4 type B1 (20 mm graded aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete concrete all as specified and directed.
M&L for RCC(Nominal mix), 1:2:4 type B1 ( 20mm graded aggregate) as in Beams, cantilevers, bressummers,lintels over 1.5m spanall as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffit (if any) of foundation and plinth beams, and similar work vertical or batter for rough finished surface all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands inwalls, horizontal or sloping, and similar work all exceeding 20cm wide.
M&L for mild steelTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete as specified.
All as item no 85 here in before but 6mm to 8mm dia in stirrups
S & F Rolled mild steel in sections Fe 410 grade E-250 as in framing for poles, cladding, glazing and the like fixed with angle cleats and connecting plates, etc complete all as specified & directed
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 E-250 all as specified and as directed.
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as specified and as directed.
S & F of fibre minerl board false ceiling system complete with 12 mm thick ceiling boards and powder coated GI frame work with sections not less than 0.7 mm thick all as per manufure instructions all as specified and directed. Make- ARMSTRONG/ GYPBOARD/ EVEREST/ AEROLITE
M&L for Vitrified ceramic tiles 10mm thick (square/ rectangular) polished,light shade area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including cement screed or bedding layer of cement mortar 15mm thick in 1:6 complete all as specified & directed
All as iteme No.91 above but on skirting over 10mm thick cement plaster in 1:4 as backing coat.
M & L Powder coated Anodized Aluminium Frame for doors, windows, ventilators, partions with one or more rebates including joining cleat for fixing etc. In repairs complete all as specified
M & L Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55Kg/m including necessary joining cleats,m glazing clips, ruber neoprene packing, handles 2 Nos in each door hinges, anodised aluminium snap beading screws etc. complete all as specified.
M & L for 12mm thick Prelaminated particle board, interior grade,prelaminated both sides with decorative choice lamination & fixed with screws to timber/aluminium frame work complete all as specified & directed
M & L for 4.80mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m each complete all as specified & directed
M&L for Aluminium body Door closer hydraulically regulated,designation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified & directed
M&L for cement concrete 1:2:4 type B- 2 (40 mm graded aggregate) as filing in mass concrete all as specified and as directed.
S&F for Mild steel Stairs (framed) including stringers, treads, landing,balusters, hand rails etc. including cleats, brackets, etc. conforming to Fe 250 Gde E Quality A complete all as specified.
Material and Labour for ceiling rose 3 terminals complete all as specified & directed.
S&F LED PC batten light fitting of 2 feet 10 watt, with energy efficient LED and integrated electronic driver of 10W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed.
S&F energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser complete with and incl 10W LED all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 230 / 300 mm sweep with, blades, and frame and louvers complete all as specified and directed.
S & F MCB SPN 32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB DB SPN 4 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Material and Labour for 150mm bore salt glazed stone ware drain pipes laid in trenches and jointed in CM (1:1) and tested complete all as specified and directed
Material and Labour for PCC (1:3:6) type C2 for bed to drain pipes 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as directed.
Material and Labour for Cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, benching including finishing the concrete surface even & smooth without using extra cement including necessary form work complete all as specified & directed
Extra for forming fair finished drain or channel up to 55 cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stopped ends etc.
Material and Labour for pre cast cover slab using PCC (1:2:4) type B1 and set in cement mortar 1:6 with top surface finished even & fair complete all as specified.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 4 core x 10 Sqmm complete all as specified and directed.
Supply & Fix MCCB TPN 415 Volts 63 Amps, 25 kA with adjustable thermal & magnetic release complete with making all necessary connections as per site requirement in Existing LT Panel backside of SBI ATM complete all as specified and directed and directed by Engr-in-Charge. (At LT Panel Existing Panel backside of SBI ATM)
Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls etc complete all as specified and directed.
M & L for sub main wiring complete with two runs of 2 x 1.5 sqmm FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in recessed / surface of wall, roofs etc with one run of PVC insulated copper conductor 1x1.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
Supply and fixing in repairs 36W LED Fitting, 2 x 2 recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified and directed.
S&F modular White cover plate with frame 3 module complete all as specified & directed
S&F modular metal flush box 3 module complete all as specified and directed.
S&F modular White cover plate with frame 6 module complete all as specified & directed
S&F modular metal flush box 6 module complete all as specified and directed.
Supply & Fix single pole and neutrla enclosure with two pin and earth plug and socket including 1 Nos MCB double pole of capacity 20Amps complete all as specified and directed by Engr-in-charge
M & L for sub main wiring complete with two runs of 2 x 2.5 sqmm FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in recessed / surface of wall, roofs etc with one run of PVC insulated copper conductor 1x2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with two runs of 4.0 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4.0 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with Four runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 10 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
S & F MCCB DB Vertical TPN 4 Way 'A' Frame, Including MCCB TPN 63 Amp Beaking capacity 16 KA -01 nos, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. Make -Havells or equivalent.In LEGRAND/ABB/SIEMENS
S & F MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. Make -Havells or equivalent.In LEGRAND/ABB/SIEMENS
S & F MCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. Make -Havells or equivalent.In LEGRAND/ABB/SIEMENS
S & F MCB TP 63 Amps incl making connections all as specified and directed. Make -Havells or equivalent.In LEGRAND/ABB/SIEMENS
S & F MCB TPN 40/63 Amps incl making connections all as specified and directed. Make -Havells or equivalent.In LEGRAND/ABB/SIEMENS
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
Supply, laying, jointing & testing LT electric power under ground cables in trenches or passing through pipe 1100 volts grade, heavy duty with aluminium conductor of cross sectional area 25 sqmm 4 core with all fixing & connecting accessories such as copper cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
Ditto All as per Srl item No 134 here in above but size of cable 16 Sqmm 4 core
Relocation/ Shifting of Existing LT Panel near Bldg No 345 and rerouting of existing power supply with out any damage to panel (damages of panel/ meters to be rectified/replace of same specification of damaged items to be replace by the contractor with in the quoted cost) including demolishing the existing PCC removing the panel from its existing place,including diconnecting the cables with line diagram /identification marks to relocation points, shifting the Existing LT panel with required PCC footing 1:2:3 to the required place as per site requirement with connecting incomming cables and out going cables to suit the existing required glands as per site requirement (Note:- after completion of work, conformation and testing the supply of the each point from users.
Disconnection of existing pipe connection any size and removing electric connection and taking out borewell colmn GI pipe with existing submersible pump set of any size (5 HP to 12.5 HP), 3 phase 415 Volts in 200/250 mm size tube well up to existing depth of bore and covered the borewell covers with MS iron plate with suitable thickness complete all as specified and directed. (Note :- Existing submersible pump with connected pipe,electric cables and deposited to MES Store Yard deemed to be included in the quoted rate)
M&L for cutting cast iron pipes of and reducing to required lenth and insertion of new tees, brances before laying pipes in trenches of upto 80 mm bore complete all as specified and directed.
Supply and lay GI pipe galvanised "medium class" inclding fittings 20mm(3/4") bore complete all as specified and directed and directed by Engr-in-Charge.
Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC.
Taking down/Shifting of Split AC 1.5/2 Ton capacity ( Indoor and Out door Unit) with stabilizer by removing all electrical connections and indoor to out door unit gas pipes ,nut bolts from first floor of P-345 bldg and shifted to Ground floor in Bldg No - 345 after completion of False ceiling work, Refixing /installing Split AC 1.5/2 Ton with voltage stabilizer as per site directed by Engr-in-charge by connecting all electrical connections and copper piping with insulation (5/8th x 1/4th) with nut bolts as per site requirement, testing and commissioning , if any extra cable , gas pipes , gas filling require at the time of installation the quoted rate is deemed to be included , No nextra cost will be paid to contractor complete all as specified and directed By Engr- In - Charge.
Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed.
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store and after false ceiling work hanging only ceiling fan (M.D supply) with extension rod as per site required and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed/ surface type conduit/ casing caping of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point /Fan point/ bell point controlled by one switch.
All as per item No 144 but for One 5 Amps socket point on same board with other switches
All as per item No 144 but One 5 Amps socket point on independent board.
All as per item No.144 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board .
All as per item No.144 above but wiring complete with 4.0 Sqmm for 3 pin 15/30 A socket multipurpose on independent board .
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
S & F modular socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing bell push flush type 5 Amps complete all as specified & directed.
S & F Door bell AC, 230 volts, single pole complete all as specified and directed.
S&F single pole and neutrla enclosure with two pin and earth plug and socket including 1Nos double pole MCB 32 Amps capacity complete all as specified and directed by Engr-in-charge
S&F Triple pole and neutral enclosure with Three pin and earth plug and socket including 1 No. Triple pole MCB 63 Amp capacity complete all as specified and as directed. Make -Havells or equivalent.In LEGRAND/ABB/SIEMENS
Supply and fixing wall mounting fan of single phase 230/240V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed .
Removing the incoming and out going cable connection carefully from the existing Change over Panel of DG sets 75 KVA and 63.5 KVA and kept aside for re connection. After New LT Panel reinstalled the both DG Set cable reconnecting care fully and testing of DG set as directed at site complete all as specified and directed.
S & F MCCB DB Vertical TPN 8 Way 'A' Frame,Including MCCB TPN 125 Amp Beaking capacity 25Ka -01 nos, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. Make -Havells or equivalent.In LEGRAND/ABB/SIEMENS
M & L Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus hard/dense soil including removal cutting of road portion to a distance n exc 50 m and making good surface all as specified .
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessarydrilling, bolting or riveting, embeding in concrete etc.,and similar work conforming to Fe-290 Gde E-165
Supply only Chain link MS galvanisd fencing, any size or type
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire
M&L for coloured Machine pressed rubber moulded precast concrete interlocking paver block with white cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35Grade complete all as specified and directed by Engr-in-charge. Make-MEHTAB/ NITCO/ ULTRA TILES/ BHARAT
M & L for sand filling under interlocking paver block not exc 50mm thick, including watering and consolidation as directed
Taking down Split/Multi AC unit 1.5/2 Ton capacity/3 ton capacity(indoor and outdoor unit) with voltage stabilizer and AC manager by removing all electrical connections and indoor to outdoor unit gas pipes, nut bolts from HQ bldg and shifting to store for safe custody. After completion of civil work, Refixing /installing Split AC /window AC 1.5/2 Ton with voltage stabilizer at the suitable place by connecting all electrical connections and copper piping with insulation (5/8th x 3/8th and 1/2" x 1/4") with nut bolts as per site requirement, testing and commissioning, if any extra cable ,gas pipes, gas filling require at the time of installation the quoted rate is deemed to be included, No extra cost will be paid to contractor complete all as specified and directed by Engr-in-charge.
M & L for Disconnecting all the electric connection from fire smoke detectors ,Removing from site , shifting and re installing the complete set up including fire panel at another location in the same complex including all necessary tools and plants all as spd and directed by Engr in charge
M & L for Disconnecting all the electric connection from Maint LT Panel , Rmoving from site , shifting and re installing the complete set up at another location in the same complex including all necessary tools and plants all as spd and directed by Engr in charge
M & L for sub main wiring complete with two runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 1x 10 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
S & F MCCB DB Vertical TPN 4 way 'A' frame,including MCCB TPN 63 Amp breaking capacity 16 KA- 02 nos, double door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match complete all as specified and directed. Make- Havells or equivalent
Supply, laying and testing cable PVC bedded, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 35 sqmm single core
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each all as specified and directed
Provision of 5.5 mm thick tinted glass exc 0.5 sqm of each pane of superior quality fixed to alluminium frame works with rubber beadings Complete all as specified and as directed by Engr-in-Charge.
S&F for 12mm thick prelaminated particle board, fixed to aluminium framework, complete all as directed by Engr-in-Charge.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
B5BUILDING SOLUTIONS (BID ID -3276517)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .