Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹28.4 L+₹5.4 L (23.3%)Rejected-AOC GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
5 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH PUNE
No 1 General Bhagat Marg Pune 411040
REPAIRS / REPLACEMENT AND SERVICING TO SUMMER APPLIANCES AND WALK-IN-COOLER IN THE AREA OF AGE EM UNDER GE SOUTH PUNE
2020_MES_384377_1
8200 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹70,000
Yes
12 Dec 2020
8 Oct 2020
7 Nov 2020
8 Oct 2020
5 Nov 2020
23 Oct 2020
60 days
Amount
NOTE FOR SL. ITEM NO. 02 to 95 BELOW - (a) ONE Ref Mech (Min) to be present daily to attend complaint and carry out other works as per CA. (b) If found absent Three times the Min wages will be dedcuted for the days of absentees. (c) Attending complaints and carry out other repair works as per CA has to be carried out in COVID Hospital at AICTS, CHSC, ALC where Ref Mech with helper has to go inside COVID WARD where COVID positive Patient are treated if complaints are not attended 5 times the Min wages of Ref Mech with helper will be deducted till complaint are not attented and Decision of GE is final and binding. (d) All protection PPE kit and other safty measure will be provided by Hospital Authority. (e) Necessary insurance coverage should be taken for staff by Bidder. (f) All rates for the above are deemed to be included in SCH (BOQ) items.
M&L for taking out the desert cooler from the site dismantling the parts of desert cooler, complete all as directed, cleaning of distribution pipe for proper water spray on pads, oiling the fan motor & pump motor complete & reassembling & fixing in position all as per direction of Eng-in-charge.
M&L in replacement of PVC water tube and distribution with 3 way PVC connection assembly complete for Air cooler/desert cooler of any size and capacity all as directed.
M&L for removing pump motor set of Air cooler/desert cooler of any size and capacity and fixing new pump motor of suitable capacity and size complete all as specified and as directed by Eng-in-charge.
M&L in replacement of caster wheels (set of four) complete for Air cooler/desert cooler of any size and capacity all as directed.
M&L for replacement of switch assembly complete for Air cooler/desert cooler of any size and capacity all as directed.
M&L in replacement of wooden fibre (set of three) of air / desert cooler of any capacity complete all as specified and as directed.
M&L for replacement of old worn out wiring of desert cooler by using copper conductor wire PVC sheathed of suitable size and length complete all as specified and as directed.
M&L for servicing the deep freezer unit completely for trouble free working and satisfactory performance by means of cleaning each part of the machine carefully, greasing/oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and pressure air through blower and cleaning the machine for better working complete all as specified and as directed.
S & F new door handle as per sample in replacement of old broken handle of Deep Freezer complete all as specified and as directed.
S & F new door gasket in replacement of old unserviceable door gasket of Deep Freezer of any capacity complete all as specified and as directed.
M&L for gas charging with F-22, R-134(a), 407a gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length flare nut, dead plug, dead cap etc. complete with testing and commissioning for the followings :-
Refrigerator of any capacity & any make
Water cooler of any capacity & any make
Deep Freezer of any capacity & any make
Window type AC of 1.5/2 TR capacity
Split type AC of 1.5/2 TR capacity
Split type/Cassette type AC / ductable type AC of 2.5/ 3 / 5TR capacity
Taking down unserviceable/damage wall mounted cooling coil unit of split type AC / ductable type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil unit of suitable capacity of existing dismantled model or equivalent approved make including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity :-
Suitable for 1.5 TR capacity, split AC, 230VAC
Suitable for 2 TR capacity, split AC, 230VAC
M&L for replacement of copper tubing, confirming to relevant IS, of 5/8" and 3/8" flare size, or nearest size, 3core 2.5sqmm copper cable, PVC drain pipe and insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed .
S&F in replacement of air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter's size and shape, as directed for 1.5/2 TR capacity of split type AC complete all as specified and as directed.
M&L for taking out old broken drain outlet pipe of any type attached to indoor unit of split type AC and S & F new drain outlet PVC pipe 20mm dia from indoor unit to nearest suitable drain outlet for split type AC of any capacity as directed.
Taking down unserviceable wall mounted cooling coil unit complete of 1.5 / 2TR capacity by means of disconnecting electrical connection and suction /discharge pipe line, testing it for leakage of gas and repair it by means of brazing, again testing for leakage of gas and connecting electrical connections and suction / discharge pipe line, drain water pipe line,etc complete all as specified and as directed.
Taking down unserviceable / damaged / rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor unit consisting of body, motor, condensor & blade suitable for existing dismantled model or equivalent approved make and connect to suction and discharge pipe line to compressor after refixing compressor of existing unit as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity :-
Suitable for 1.5 TR capacity
Suitable for 2 TR capacity
M&L for checking of remote control with PC board complete for its workability for split type AC of any capacity, removing the same & taking it to the workshop for repairs, Refitting it after the repairs to its original location as directed.
Supply only suitable remote control handset of split type AC of any capacity in replacement of old unserviceable remote control handset of any type complete all as specified and as directed.
Supply and Fix in replacement service valve of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity complete all as specified and as directed.
Supply and Fix in replacement brass flare nut of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity complete all as specified and as directed.
S & F in replacement factory made angle iron stand outdoor unit of split type ACs of any capacity complete all as specified and as directed.
M&L in replacement of blower of indoor unit of split type air conditioner suitable for 1.5/ 2 TR capacity as per sample complete all as specified and as directed.
Servicing only for split type AC of any capacity, including chemical wash or equivalent, to condenser and cooling coil, cleaning the entire parts, oiling/greasing to condenser motor, cooling coil blower motor complete as directed .
S&F in replacement single shaft, blower motor of 1/6,1/8,1/5 HP capacity for split type AC of capacity 1.5/2 TR/Air Curtain of any size complete all as specified and as directed. [Make - AUE, Fracmaster, Popular]
S&F in replacement swing motor for split type AC of any capacity complete as per sample as directed .
M&L for replacement of unserviceable remote control with PC board complete suitable for existing model of split AC of 1.5 / 2 / 2.5 TR capacity as directed with existing make.
M&L for replacement of 5/8" and 3/8" or nearest tube size insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete all as specified and as directed.
S&F single pole contactor of suitable model and size for 1.5 / 2 TR split type AC complete all as specified and as directed.
S&F 3 pole power contactor 25Amp, 220VAC for 3TR split type AC complete all as specified and as directed.
Labour only for removing/reinstallation of split type AC 1.5 / 2TR capacity, indoor & outdoor unit including all allied work such as bending, shaping, brazing to copper tubing & insulation to tubing, connection of water drain piping & fixing it properly, etc including testing & commissioning complete all as specified and as directed.
Servicing only window type AC complete with chemical wash to condenser and cooling coil, cleaning of entire elements of AC, oiling/greasing to motor including taking out & refixing the machine at its original location complete all as specified and as directed.
S&F in replacement of blower of window type air conditioner suitable for 1.5/ 2 TR capacity as per sample complete all as specified and as directed.
S&F in replacement coir / Mesh air filter of suitable size for window type AC complete all as specified and as directed
S&F in replacement of broken/damage front grill assembly complete suitable for existing model of window AC of any capacity complete all as specified and as directed.
Taking out burnt/unserviceable fan/blower motor of window type AC of any type & capacity and S&F new fan/blower motor double shaft single/double speed, single phase, 230 V , AC of 1/4HP, 1/5HP, 1/6HP or any other capacity as required complete, making suitable fixing arrangment for existing place (as per sample) (Make - AUE/Francmaster/Popular )
M&L for cutting the existing window including additions/alterations to make opening suitable for fixing the window type air conditioner including welding/wood work as per site requirement to match with adjoining/existing surfaces and shifting the window type air conditioner to the new altered location/existing including the necessary connections and testing complete all as directed.
S & F new sealed unit compressor of approved make and capacity, 230 VAC, all as specified and directed by the Engineer-in-Charge including Taking down carefully old unserviceable, burnt out sealed unit compressor complete all as specified for the following capacities :-
Compressor for refrigerator of capacity 165/170/175/180 Ltrs
Compressor for refrigerator of capacity 192/210 Ltrs
Compressor for refrigerator of capacity 300/320 Ltrs
Compressor for water cooler of capacity 40/80 Ltrs
Compressor for water cooler of capacity 60/120 Ltrs
Compressor for water cooler of capacity 150 Ltrs
Compressor for deep freezer of capacity 200 to 500 Ltrs
Compressor for Window type & split type AC of capacity 1.5 TR
Compressor for window type & split type AC of capacity 2 TR
Compressor for Split type AC of capacity 2.5 TR, 3 phase 440 V AC
Compressor for Split type AC / Tower AC of capacity 3 / 5 TR, 3 phase 440 V AC
Taking out old unserviceable thermostat and S&F new thermostat of approved make and suitable size & model for the following :-
Auto 'D' thermostat No 1027 with knob for refrigerator or equivalent
Thermostat No 2064 with knob for water cooler or equivalent
Thermostat No 2059 with knob for window type AC or equivalent
Thermostat with knob for suitable for deep freezer of any capacity
Taking out old unserviceable relay unit and supply and fix new relay kit (OLP + LMS relay or box type) as per sample for refrigerator/deep freezer complete all as specified and as directed.
Taking out old unserviceable relay kit and S&F new relay kit as per sample for water cooler, No 412Y / 512Y or equivalent complete all as specified and as directed
Taking out old unserviceable relay of any type and S&F new potention box type relay / PTC of suitable model for window / split type AC complete all as specified and as directed.
M&L for Vacummising the complete system of walk-in-cooler with double stage vaccum pump of 2kg/cm2 and charging with Nitrogen gas upto 250-300 PSI the complete system for leak testing and maintaining the pressure for 24 hrs and rectifying the leakage, if any in the system and after that charging the system with R-22, 134a, 407a and 410a gas as required quantity as directed by Enginner-in-charge
S&F in replacement of HP/LP cut off, KP-15 complete all as specified and as directed. [Make - Danfoss/Indfoss for Walk-in-Cooler of any type]
S&F in replacement Drier filter of 5/8", 3/8", 1/2" flare size or other nearest flare size complete all as specified and as directed [Make - Sporlon / Catchall or equivalent]
S&F in replacement of indoor discharge fan for walk-in-cooler of size 10" complete as directed.
Taking out old/burnt running capacitors and S&F new running capacitors of following capacities :-
Running capacitor 10/15/25 MFD
Running capacitor 36 MFD
Running capacitor 45 MFD
Running capacitor 55+6 MFD
Taking out old / burnt starting capacitors and S&F new starting capacitor of following capacities :-
Starting capacitor 40 to 60 MFD
Starting capacitor 60 to 80 MFD
Starting capacitor 80 - 100 MFD
Starting capacitor 100 - 120 MFD
S&F in replacement MCB, SP, 20- 32 Amps, 10KA, 230V 'C' series complete all as specified and as directed
S&F in replacement MCB, SPN, 40 Amps, 10KA, 230V 'C' series complete all as specified and as directed
M&L for replacement of old worn out/burnt wiring for window / split type A/C of any capacity complete all as specified and as directed
S & F in replacement MCB TPN, 415 Volts, 60 Amps, 10KA, 230V, 'C' series complete all as specified and as directed
S&F in replacement DP indicator switch, 32 Amps complete all as specified and as directed
Taking out old unserviceable/broken knobs & S & F new knobs for window type AC/desert cooler of any capacity complete all as specified and as directed.
Taking out old/burnt fan motor capacitors including S&F new fan motor capacitors complete all as specified and as directed
M&L for replacement of old worn out/burnt wiring of water cooler/ deep freezer by using copper conductor wire PVC sheathed of suitable size and length complete all as directed by Engr-in-charge.
S & F new 5Amp pin top in replacement of old broken pin top of any ISI make complete all as specified and as directed.
S & F new 15Amp pin top in replacement of old broken pin top of any ISI make complete all as specified and as directed.
M&L for replacement of 3 core, 4 sqmm, copper conductor PVC insulated flexible cable from main supply point to out door unit point as directed and specified by Engineer-in-Charge
All as per item No. 61.00 above but 3 core, 2.5 Sqmm all as specified
All as per item No. 61.00 above but 3 core, 1.5 Sqmm complete all as specified and as directed.
All as per item No. 61.00 above but 3 core, 6 Sqmm complete all as specified and as directed.
S&F in replacement of sheet metal enclosure with socket plug top & MCB ,single pole & Neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
S&F in replacement of 3pin plug suitable for industrial metal clad socket, single phase 230 volts AC complete all as specified and as directed.
M&L for replacement of burnt out sub main wiring complete with two single core 4 sqmm,1100volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 2.5 sqmm in and including PVC casing caping complete all as specified and as directed (Note : 2 runs of 4 sqmm cable and 1 run of 2.5 sqmm earth wire and 1 run of PVC casing caping shall be measured as one length.)
S&F in replacement for fan blade (As per sample) window type AC/split type AC / Desert Cooler of any capacity complete all as specified and as directed.
S&F in replacement of unserviceable/leakage cooling coil complete suitable for existing model of refirigerator for the following :-
Refrigerator of capacity 165/170/175/180 Ltrs
Refrigerator of capacity 192/210 Ltrs
Refrigerator of capacity 300/320 Ltrs
M&L for taking out the Air Curtain of any size from the wall above the door, cleaning the blower complete, & refixing in position all as per direction of Eng-in-charge.
M&L in replacement of unserviceable / rusted condensor complete suitable for existing model of refirigerator for the following :-
Refrigerator of capacity 165/170/175/180 Ltrs
Refrigerator of capacity 192/210 Ltrs
Refrigerator of capacity 300/320 Ltrs
M&L in replacement of chiller tray complete suitable for existing model of refrigerator of any capacity complete all as specified and as directed.
M&L in replacement of metal shelf powder coated suitable for existing model of refrigerator of any capacity complete all as specified and as directed.
M&L in replacement of broken freezer door complete with casing and lock nut as per sample for refrigerator of any capacity complete all as specified and as directed.
M&L in replacement of vegetable tray complete suitable for existing model of refrigrator of any capacity complete all as specified and as directed.
M&L in replacement of bulb pin type / thread type suitable for existing model of refrigerator of any capacity complete all as specified and as directed
M&L in replacement of broken door panel gasket complete suitable for existing model of refrigeratior of any capacity complete all as specified and as directed
M&L for disconnecting the water cooler of any capacity from electric and water connection. Cleaning the condensor unit by using carbon tetra chloride, cleaning the condensor fins, oiling/greasing the fan motor, checking of alignment of motor cleaning of water storage tank and Fixing back the water cooler and testing all as directed by Eng-in-charge.
S & F in replacement PVC connection 15mm size with PTMT nuts of following sizes:-
Taking out old broken PVC flexible drain outlet pipe and S & F new drain outlet pipe 32/40mm dia complete for water cooler of any capacity complete all as specified and as directed.
M&L in replacement of Old unserviceable push cock, 15 mm dia for water cooler complete all as specified and as directed
M&L in replacement of Old unserviceable stop cock, 15 mm dia for water cooler complete all as specified and as directed
S&F in replacement fan blade (As per sample) water cooler/ deep freezer of any capacity complete all as specified and as directed
Taking out old unserviceable/broken float valve & S & F new float valve complete for water cooler of any capacity complete all as specified and as directed.
M&L in replacement of burnt out condenser fan motor, single shaft 1/35 HP capacity, single phase, 230 VAC for water cooler complete all as specified and as directed
M&L in replacement of burnt out condenser fan motor, single shaft 1/83 HP capacity, single phase, 230 V , AC for water cooler complete all as specified and as directed
M&L in replacement of burnt out condenser fan motor, single shaft 1/10 HP capacity, single phase, 230 V , AC for water cooler complete all as specified and as directed
M&L for checking of drain water tray for leakage & getting the same repaired by soldering all the sides of the tray including making proper provision for fitting of grating to the tray to make it functional as directed by Engineer-in-charge
M&L for repair/replacement of corroded bottom portion of the water cooler of any make & capacity with MS angle iron of suitable size as per existing, including welding/brazing with MS sheet 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as directed by Engineer-in-charge
M&L for removing of old unserviceable stabilizer of capacity 5KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fixing at the same position and checking it for its workablility complete all as specified and directed by Engr-in-Charge.
All as per Item No. 90.00 here-in-above but stabilizer capacity 4 KVA complete all as specified and as directed
All as per Item No. 90.00 here-in-above but stabilizer capacity 2 KVA complete all as specified and as directed
All as per Item No. 90.00 here-in-above but stabilizer capacity 1 KVA complete all as specified and as directed
All as per Item No. 90.00 here-in-above but stabilizer capacity 0.5 KVA complete all as specified and as directed
M&L for removing Industrial cooler / desert cooler of any size and capacity from site, dismantling the worn out fan motor, supply and fixing of new suitable motor in position including testing and commissioning complete all as directed by Eng-in-charge.
M/s Vijay Airconditioning Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .