Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹18.8 L+₹86,500 (4.81%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹23.7 L+₹5.7 L (31.8%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹23.7 L+₹5.7 L (31.9%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹20.5 L
EMD Value
₹41,020
Closing Date
3 Jul 2023, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain sanctioned (special repairs / minor / revenue) works of E/M nature under GE (N) Ahmednagar
2023_MES_601570_1
8765 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer North Ahmednagar
Class E Cat b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer(North) Ahmednagar
₹41,020
Yes
12 Jul 2023
6 Jun 2023
5 Jul 2023
6 Jun 2023
3 Jul 2023
19 Jun 2023
Amount
Supply and install hi wall split units indoor/outdoor of Capacity 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and Efficient & Hyper Tropical Inverter Split AC with Copper , blue film condensor and it is Equipped with R410 A gas Refrigerant having 25 mtr long reach Air flow,6 speed fan control,noise level within 34 db , with warranty 01 year warrenty, equipped with Indoor/Outdoor, remote Etc. Make:- Hitachi/'O' general/Carrier
M&L for submain wiring with 2 runs of 6 Sqmm & one run of 4 Sqmm single core copper conductor cable 1100 Volts grade complete in & including PVC casing & caping complete.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp.
Supply and lay cable XLPE Insulated , screened , PVC bedded galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 185 Sq mm 3.5 core
M&L Factory made Outdoor type Panel, made out of 16 SWG CRCA Sheet, Powder Coated, Weather Proof, Front Opening Shutter with proper Locking Arrangements, suitable for Totally Enclosed complete and grouting in Cement Concrete 1:2:4 (20mm graded stone aggregate) Work of suitable size including necessary Electric Connections and Testing, Comprising with the followings including Taking down unserviceable Panel, complete all as specified and as directed:-M&L Factory made Outdoor type Panel, made out of 16 SWG CRCA Sheet, Powder Coated, Weather Proof, Front Opening Shutter with proper Locking Arrangements, suitable for Totally Enclosed complete and grouting in Cement Concrete 1:2:4 (20mm graded stone aggregate) Work of suitable size including necessary Electric Connections and Testing, Comprising with the followings including Taking down unserviceable Panel, complete all as specified and as directed:- (a) Aluminium Bus-bar 4 Strip, 450mm long, 400 Amp, 415 Volt - 01 Set
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Supply & laying of Telerex DWC(Double wall corrugated) HDPE pipe ISI marked ( Pipe colour orange) of outer dia 110 mm and Inner dia 95 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends complete all as specified and directed.
M&L Heat shrinkable straight through joint, with including jointing materials and necessary earth work suitable for 1100 Volts , XLPE LT cable of size 185 sq.mm , 3.5 core, including fixing, jointing and testing complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3 mm thick of outer body of suitable size with aluminium bus bar (100 x10 mm) 1000 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specifid and directed.( R C Road)
(i) MCCB 630 Amp adjustable type with , 4 Pole,50 KA - 01 No. (Ics=100%Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable (viii) KWH meter CT operated as per suitable capacity of LT Panel Outgoing ways :- MCCB 200 Amps adjudtable type ,4 pole,25 KA-03 Nos (Ics=100%Icu MCCB 125 Amps adjudtable type ,4 pole,25 KA-03 Nos (Ics=100%Icu) MCCB 63 Amps adjudtable type ,4 pole,25 KA-01 Nos (Ics=100%Icu)
Notes:- 1. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for earth work,Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 3. All MCCBs should be handle operated and outgoing mccbs should be connected with suitable size/rating HRC Fuse. 4. Make of MCCBs - L&T,Legrand,ABB,Schinder. 5. All cables in existing panel to be terminated to the new panel with proper crimping lugs, suitable size of gland, colour coding and small length of existing cable along with straight through joint if required at site ( cable length not more than 6 Mtr)
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3 mm thick of outer body of suitable size with aluminium bus bar 600 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specifid and directed.(Eletroic wing/B sub station)
Incoming : - (i) MCCB 400 Amp adjustable type with , 4 Pole,36KA - 01 No. (Ics=100%Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable (viii) KWH meter CT operated as per suitable capacity of LT Panel Outgoing ways :- MCCB 160 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu) MCCB 125 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu MCCB 63 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu)
Notes:- 1. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for earth work,Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 3. All MCCBs should be handle operated and outgoing mccbs should be connected with suitable size/rating HRC Fuse. 4. Make of MCCBs - L&T,Legrand,ABB,Schinder. 5. All cables in existing panel to be terminated to the new panel with proper crimping lugs, suitable size of gland, colour coding and small length of existing cable along with straight through joint if required at site ( cable length not more than 6 Mtr)
Material and labour for earthing complete with copper earth plate electrode 600 x 600 x 3.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to copper strip 20 x 3 mm, by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, PCC cover with locking arrangement including covering the plate wit one coart of non corrosive chemical coating use for earthing, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of copper strip 20 x 3 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil.
Supply & lay HDPE pipe 75mm bore for laying of LT cables etc complete with all accessores all as specified and directed
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor 120 sqmm 3.5 core after removing old unserviceable cable.
Supply and fix desert cooler electric driven (single phase), of model Jumbo 75 XL having tank Capacity 75 Ltrs.PVC Body etc complete all as specified and directed by Engineer-in-Charge. Make:- Simphony Jumbo 75XL or Equivalent
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed.
One 3 pin 5 amps socket outlet on independent board
S&F switch socket combination multi purpose 2 in 1, 3 pin 5 Amps ,flush type ,ISI marked all as specified and directed
An amount of Rs 11,230.00 shall be deducted from BOQ on account of schedule of credit
M/s. Chhtrapati Construction(Propa. Lokesh Anant Salunke)
M/s. N D Karande
Ms. S.K. ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .