Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC PLOT NO 515 JAGANNATH BHAWAN PROFESSORPARA B K ROAD A D MARKET CUTTACK 753 012 ODISHA | CUTTACK | CUTTACK | ODISHA | 753012 | L1 | Accepted-AOC resultant single tender |
Tender Value
₹7.6 L
EMD Value
₹22,900
Closing Date
16 Aug 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
REGISTRAR
Institute of Physics, PO-Sainik School Bhubaneswar-751005
Power Supply to AC in different rooms of Extension Building of IOP
2022_IOPB_699601_1
NIT/IOP/04/2022-23
Open Tender
Electrical Works
Works
60 days
Institute of Physics, PO-Sainik School Bhubaneswar
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹22,900
Yes
18 Oct 2022
23 Jul 2022
17 Aug 2022
23 Jul 2022
16 Aug 2022
23 Jul 2022
180 days
Amount
M.V. PVCA CABLES: Supply, installation testing & commissioning of 1.1KV grade PVC insulated, inner sheath tapped, outer sheath PVC extruded, GI strip/armored, multi stranded/ Aluminum conductor power cable as per IS 1554 specifications, fixed on wall/column/slab/in existing hume pipes/ trenches by 5mm thick GI spacer fixed/coach screws/anchor fasteners in brick/stone wall /column/slab with 2mm thick GI saddle, all fixing accessories etc. complete including painting of saddle /flat/angle iron etc. The space between two supports shall be generally 600mm or in ground at a depth of 900mm, below ground including excavation in all types of soil excluding hard rock if any cutting of existing footpath, roads etc, sand bedding, laying of baked bricks as per IS on side & top, temporary reinstatement, back filling, de-watering if necessary, consolidation, disposal, of excess earth with in the radius of 500mtr. Etc. all as per the instructions of engineer-in-charge. The tinned copper earth wires to be laid along with the cables should be painted with two coats of black bituminous compound for earth wire in ground and Jointing of the earth wire shall be solder joints with tinned copper cable sockets & GI nuts & bolts. Note: Scope includes all types of masonry work required making good to its original finish of holes through wall, roads, slopes etc. after laying of the cable. Make of cables: Finolex/ NICCO/ CCI/ Polycab or approved equivalent of the same.
1 no x 4 core x 25 Sqmm Al. PVCA cable and 01 no. of 8 SWG tinned copper earth wires. (From 1st floor AHU panel to AC DB-1F & 2F of First floor and From 2nd floor AHU panel to AC DB-1S & 2S of Second floor)
Wiring in PVC Casing & Capping: Supply Installation, testing & commissioning of 1100V FRLS grade PVC insulated multi stranded copper conductor wires in suitable casing & capping with double interlock, meeting with IB/IS specification. Arrangements to be made for holding the wires in position in trunk, on ceiling/ wall with counter sunk tinned brass wood screw fixed with nylon plug etc. complete with all accessories like right angle bend, outer inner bend, T-stopper, PVC clamps (preferable) suitable pull boxes/ junction boxes of suitable size as per the site condition wherever required & with necessary leads at both ends by approved copper lug, complete as per the instructions of Engineer-in charge. Note: 1. Connection shall be done with crimped type tinned copper lugs and washers. 2. Casing & Capping should be white & make: Precision, Asian & circle IS 14927 marked or approved equivalent of the same. 3. All PVC insulated copper conductor FRLS grade shall be ISI marked. 4. Make of wires: Finolex/ L&T or approved equivalent of the same.
03 nos. of 4Sqmm wire in PVC casing & capping.
DISTRIBUTION BOARDS: Supply, Installation, testing & commissioning of following medium voltage (415V) TP&N distribution boards double door complete with necessary SFU, MCCB, MCBs, etc. suitable for wall mounting with M.S. frame work of 40x40x5mm angle mounting with M.S. enclosure fabricated out of 16SWG thick M.S. CRCA sheet with concealed hinged door, cam type locking arrangement etc. Suitable tinned copper bus bars have to be provided for all phases, neutral and earth connections both for incoming and outgoing connections. Cable end box, wire way box, including interconnections with appropriate size of PVC insulated copper conductor, phase barriers, earth of DB, enameled danger board, name plate, neoprene gasket for joints & door has to be provided. Necessary metal treatment, two coats of red oxide paint & two coats of enameled paint has to be provided. The internal door (MS sheet) should have necessary cutouts for knobs/ operating levers of MCB’s. Phase distribution drawing etc. all as per drawings specifications etc. relevant IS & instruction of Engineer-in-charge-IOP (G.A. & fabrication drawing to be got approved before fabrication) Note: 1. MCB’s shall be minimum 10KA breaking capacity & Preferably of Legrand make or approved equivalent of the same. 2. All SFUs should be of L&T/ Siemens make and Fuses to be provided with that. 3. All tinned copper bus bars should be minimum of 200A rating or as mentioned in the drawing. 4. All wires to be used for wiring are should be FRLS, Finolex make or approved equivalent of the same. 5. Bolted type terminal blocks of suitable rating are to be provided for all types of input and output connections. 6. All input & output connection has to be provided with suitable cable sockets (Aluminium for Aluminium cable and Copper for copper cable) 7. If factory made DB is available of legrand or approved equivalent make suitable for this requirement same can be supplied and installed.
DB with (Legrand make readymade TPN-DB-04way (08+12) with cat no. 5076 70 with metal door IP 43-1K 09 or approved equivalent) a) a) Incomer: 04 Pole TPN MCB 63 A – 01 no. b) Out Going: SP MCB 32A – 12nos (AC DB-1F & 2F of First floor and AC DB-1S & 2S of Second floor and DB-1G & 2G of Ground floor)
MCB BOX: Fabrication, supply, installation, Testing and commissioning on concrete/brick wall/ plywood partition of local control MCB box made out of 16 SWG thick galvanized MS sheet with top cover also galvanized MS sheet duly fixed by SS screws. Necessary cut outs to be provided on the top cover for the operating lever of the MCB and suitable size gland holes at two ends has to be made for the MS conduits. MCB shall be minimum of 10 KA breaking capacity. All complete as per the instructions of Engineer-in-charge. Note: All MCB should be of Legrand or approved equivalent make.
MCB box with DP MCB of 25A rating
OUTLET SWITCH & SOCKET BOXES: Fabrication, supply, installation, Testing and commissioning on concrete/brick wall/ plywood partition of outlet switch boards made out of 16 SWG thick galvanized MS sheet with top cover 3mm thick Bakelite Hylam laminated sheet duly fixed by SS screws. Necessary wiring inside the board has to be carried out using 4 Sqmm copper PVC insulated single core flexible wire. One suitable nut and bolt has to be provided on the side wall of the board for earth connection. All complete as per the instructions of Engineer-in-charge. 1. All switches, sockets & Plug Top should be of Anchor make or approved equivalent. 2. All wires to be used should be of Finolex/ L&T make. 3. All MCB to be provided should be of Legrand make 4. All terminals of the wires to be connected inside the board should be provided with suitable copper lugs/ sockets. 5. Sample of all materials is to be got approved from EIC, IOP before execution.
Switch & Socket box with one no. of 15Amp, 6pin Socket & one no. 15Amp, 3pin Plug top.
DOL STARTER UNIT FOR AC UNITS: Supply, Installation, Testing & Commissioning (on concrete/brick wall/ plywood partition) of DOL starter units with Bimetallic O/L Relay, suitable for AC units, preferably of SIEMENS make 3TW4290-1A, AC-3, 7.5KW/10HP, 230V, 50Hz coil supply/ L&T make MN16DOL, 10HP/7.5KW, 09-15A relay range, 230V, 50Hz coil supply.
END TERMINATION OF ARMOURED CABLES: End termination and connection of the following cables by crimping with supply of all jointing materials like tinned copper cable sockets, cable glands, gland earthing insulation tape, flux, duplicate interconnection between gland earthing strip and the nearest earthing bus terminals as per the drawing, specifications, Aluminum cable tag is to be provided with each end termination and all as per the instruction of the Engineer in charge. Make of lugs/sockets: Dowels/Jainson.
4 core x 25Sqmm Al. PVCA cable
FLEXIBLE CABLES/WIRES: Supply & Laying of 1100V FRLS grade, ISI marked, PVC insulated multi stranded copper conductor (flexible) wires/cables. The wires/cables will be laid in the existing cable trench and fixed/ connected as per the instruction of the EIC. Note: Scope includes supply and to provide the binding tags wherever it is required to bind together more than one wires/cables being laid in the same line. Make: Preferably Finolex/ Polycab or approved equivalent of the same.
04 Sqmm x 4 core FR PVC insulated copper conductor flexible cable
06 Sqmm x 4 core FR PVC insulated copper conductor flexible cable.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .