| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹50.0 L+₹3.4 L (7.32%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹51.0 L+₹4.4 L (9.53%)Admitted-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L3 | Admitted-Finance | |
| 4 | L4₹53.3 L+₹6.8 L (14.5%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹53.7 L+₹7.1 L (15.2%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Indu Electricals L2 | Universal refrigeration and Engineering Company L7 | S.S.ENGINEERING CORPORATION L4 | M/s K L M INFRATECH L1 | BHAGYARAM ENTERPRISES L6 | SUN LIGHT HOUSE L5 | omsai thermax engineers L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Monthly Comprehensive (Annual Maintenance contract) of DX type Precision Type Air conditioners by deploying respective Original Equipment Manufacturer (OEM) experienced Engineer / Technical staff for following equipement i. e. 3 Nos X 20 TR capacity DX type Precision Air conditioners working 24 x7 round the clock at AVC building DATA center, including electrical connections to inspect the operation of Air conditioning units by the representative of OEM (Original Equipment Manufacturer) and carrying out preventive maintenance as per standard practice/ as per OEM recommended Repairs to defective component / Equipment, detection of Leak & rectifying the same, charging / topping up of the Refrigerant Gas complete all as specified and directed. (Note : Compressors, PCBs,Sensors, Rewinding of Motors, Refrigerant Gas will be measured & paid separately under relavent Item of this Schedule) Make: EMERSION | 9 | JOB PER MONTH | 40,250 ₹3,62,250 | 45,000 ₹4,05,000 | 30,000 ₹2,70,000 Lowest | 30,000 ₹2,70,000 Lowest | 34,500 ₹3,10,500 | 43,880 ₹3,94,920 | 45,000 ₹4,05,000 |
| 2.00Comprehensive Maintenance of VRF / VRV system Type Air conditioners by deploying respective Original Equipment Manufacturer (OEM) or experienced Technical staff from any OEM for following equipements Air conditioners at various buildings of RCI,DSP Technical Area including electrical connections to inspect the operation of VRF / VRV type Air Coditioners with connected AHU / indoor units by the representative of OEM (Original Equipement Manufacturer) and carring out preventive maintenance as per standard practice/ as per OEM recomended Repair of defective components / Equipemement, Detection of leak & rectifying the same, charging /topping up of the Refrgerant Gas and all other connected or required items as per site requirement to make it fully functionalfor the following capacity units at buildings mentioned below complete all as specified and directed. Note :a) Compressors, PCBs, Sensors, Rewinding of Motors, Refrigerant Gas will be measured & paid separately under relavent Item of this Schedule. b) Supply and fix all types of minor spare parts of value not more than Rs 500.00 shall be deemed to be included in the quoted rate. c) AC circit/system inspection and rectification of repair/replacement of any parts to make it functional shall carried out by Original Equipment Manufacturer (OEM) or experienced Technical staff from any OEM once in during the contract period. First one at commencement and the second one at middle of the contract period all as directed by the Engineer-in-charge. All documents shall be submitted to Engineer in charge and unit rate quoted shall be deemed to include for the same.) Make:CARRIER/TOSHIBA/DAIKIN/LG/BLUESTAR/MDV/VOLTAS | ||||||||||
| 2.01 | 3No.x30HP , 1No.X8hp capacity VRF outdoor with connected indoor system,at K 4 Bldg. Make: CARRIER VRF | 1 | Each Job | 21,000 ₹21,000 | 21,000 ₹21,000 | 20,000 ₹20,000 | 15,000 ₹15,000 Lowest | 17,500 ₹17,500 | 19,900 ₹19,900 | 22,500 ₹22,500 |
| 2.02 | 1No.x38HP , 1No.X50hp capacity VRF outdoor with connected indoor system,at K 4 Bldg. Make: DAIKIN VRF | 1 | Each Job | 19,000 ₹19,000 | 20,000 ₹20,000 | 21,000 ₹21,000 | 14,000 ₹14,000 Lowest | 14,500 ₹14,500 | 19,900 ₹19,900 | 20,000 ₹20,000 |
| 2.03 | 2No.x22HP , 1No.X18hp, 1No.x10HP capacity VRF outdoor with connected indoor system,at SINT CHECK OUT Bldg.,
Make: CARRIER VRF | 1 | Each Job | 13,500 ₹13,500 | 13,500 ₹13,500 | 15,000 ₹15,000 | 12,000 ₹12,000 Lowest | 15,000 ₹15,000 | 19,900 ₹19,900 | 15,000 ₹15,000 |
| 2.04 | 3No.x26 HP, 1No.x30 HP, 1No.x20 HP, 1No.x10 HP capacity VRF outdoor with connected indoor system, at MRSAM AIR FORCE., Make : LG | 1 | Each Job | 34,000 ₹34,000 | 39,000 ₹39,000 | 40,000 ₹40,000 | 22,000 ₹22,000 Lowest | 25,000 ₹25,000 | 35,400 ₹35,400 | 30,600 ₹30,600 |
| 2.05 | 3No.x14 HP capacity VRF outdoor with connected indoor system at EMI Bldg., Make: VOLTAS | 1 | Each Job | 9,900 ₹9,900 | 10,000 ₹10,000 | 12,000 ₹12,000 | 7,000 ₹7,000 Lowest | 8,000 ₹8,000 | 89,900 ₹89,900 | 9,000 ₹9,000 |
| 2.06 | 4 No.X 8 HP capacity VRF outdoor with connected indoor system at 0208 Bldg., Make: CARRIER | 1 | Each Job | 6,500 ₹6,500 | 9,000 ₹9,000 | 8,000 ₹8,000 | 5,000 ₹5,000 Lowest | 6,000 ₹6,000 | 7,330 ₹7,330 | 6,300 ₹6,300 |
| 2.07 | 3 x 30 HP capacity VRF outdoor with connected indoor system at E11U building.
Make: DAIKIN | 1 | Each Job | 20,500 ₹20,500 | 35,000 ₹35,000 | 30,000 ₹30,000 | 14,000 ₹14,000 Lowest | 15,500 ₹15,500 | 31,220 ₹31,220 | 19,800 ₹19,800 |
| 2.08 | 16 HP capacity VRF outdoor with connected indoor system at FOG building.
Make: VOLTAS | 1 | Each Job | 5,400 ₹5,400 | 4,500 ₹4,500 | 4,000 ₹4,000 | 2,500 ₹2,500 Lowest | 6,000 ₹6,000 | 4,120 ₹4,120 | 4,500 ₹4,500 |
Tender Value
₹48 L
EMD Value
₹9.6 L
Closing Date
3 Jun 2026, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIR AND MAINTENANCE OF PRECISION TYPE AIR CONDITIONERSVRF VRV TYPE AIR CONDITIONERS AT RCI UNDER GE I RND RCI HYDERABAD
2026_MES_765060_1
8414
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(I) R AND D RCI
MES enlisted Class D category c i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹9.6 L
Yes
30 Jun 2026
13 May 2026
5 Jun 2026
13 May 2026
3 Jun 2026
28 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Monthly Comprehensive (Annual Maintenance contract) of DX type Precision Type Air conditioners by deploying respective Original Equipment Manufacturer (OEM) experienced Engineer / Technical staff for following equipement i. e. 3 Nos X 20 TR capacity DX type Precision Air conditioners working 24 x7 round the clock at AVC building DATA center, including electrical connections to inspect the operation of Air conditioning units by the representative of OEM (Original Equipment Manufacturer) and carrying out preventive maintenance as per standard practice/ as per OEM recommended Repairs to defective component / Equipment, detection of Leak & rectifying the same, charging / topping up of the Refrigerant Gas complete all as specified and directed. (Note : Compressors, PCBs,Sensors, Rewinding of Motors, Refrigerant Gas will be measured & paid separately under relavent Item of this Schedule) Make: EMERSION | 9 | JOB PER MONTH | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_856877.xls
BOQ • 0.28 MB
8414PS.pdf
Tender Documents • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .