| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 06 GOVIND NAGAR PANCHAYAT USR TRANSPORT CAMPBELL BAY OLD FISHERMAN COLONY CAMPBELL BAY GREAT NICOBAR ISLANDS | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.5 L+₹1.5 L (11.0%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.6 L+₹1.7 L (11.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹16.3 L+₹2.3 L (16.3%)Rejected-AOC 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
11 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) CAMPBELL BAY
GE (I) CAMPBELL BAY, ARMY LAND, GREAT NICOBAR, PIN-744302
MANNING AND OPERATION AND COMPREHENSIVE MAINTENANCE OF ELECTRIC SUPPLY INSTALLATION AND ALLIED WORKS AT ARMY LAND CAMPBELL BAY UNDER GE (I) CAMPBELL BAY
2020_MES_380223_2
8711/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (I) CAMPBELL BAY
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (I) CAMPBELL BAY
₹28,000
Yes
26 Nov 2020
24 Oct 2020
13 Nov 2020
26 Oct 2020
11 Nov 2020
26 Oct 2020
60 days
Amount
Providing Services for Manning, Running & daily operation of Main Receiving station (HT/LT) located at Army Land Sub Station by deploying One Electrician Skilled in each shift round the clock in three shift per day (8 Hours per shift), including Sundays & holidays, Maintaining the Log sheet/ Register for Incoming & out Going feeders as directed & shown by Engr-In-charge and also attending break downs/ repairs on break down complaint calls of HT & LT lines in the area and rectifying the problems by replacing DO fuses and HT jumpers etc and restore the electric supply in area with necessary arrangements, if required for change over of HT ring main supply etc consisting of description as specified and directed. (g) SHIFT DUTIES (TIMINGS) (i) I Shift : 0600 Hours to 1400 Hours (ii) II Shift : 1400 Hours to 2200 Hours (iii) III Shift : 2200 Hours to 0600 Hours (Note :– 01 Operator per shift total three shifts – 03 Operators (Electrician) Details of Plant :- (a) Main supply at 11 KV - 02 Nos Receving points for AED (b) Setp Down Transformer 11/0.433 KV - 02 Nos : 01 No 100 KVA Near JCO Mess & 01 No 50 KVA Near Offrs Mess (c) Out going feeder - 02 Nos (d) DG Set - 03 Nos : 02 No Near JCO Mess - 62.5 KVA & 65 KW each 01 No Near Offrs Mess - 32 KVA
Repair /servicing to transformer at site of capacity 100 KVA to 320 KVA installed on Plinth / Pole mounted structure by opening top cover & replacing unserviceable spares / components of transformer ,without lifting core assembly reassembling after repair & testing complete all as specified and directed by Engr-in-Charge. Note :- (a) Dehyderation and filteration of transformer oil, and replacement of unserviceable spares shall be measured and paid seperately under appropriate Item of schedule however cost of renewal of Nut, bolts & washers shall deemed to be included in unit rate quoted
Supply only Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers
Supply only brass spindle on LT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers .
Supply only Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers
Supply only brass spindle on HT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers
Supply only breather assembly as per existing size, shape and specification complete for capacity upto 320 KVA, 11/0.433 Volts transformers
Dehydration and filtration of existing transformer oil of transformers capacity ranging from upto 200 KVA (11 KV System step down to 11/0.433 KV) on site at different locations without disturbing the power supply system with filtration machine and heating system in order to achieve Di-electric strength of oil 40 KV minimum at 2.5 mm gap complete all as specified and as directed.
Supply only Temperature Guage as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply & filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacement up to desired level of transformer oil capacity complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] (Make : GULF/POWER OIL or equivalent as approved by GE)
Maintenance and servicing, overhauling to DG set including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery tereminals, adding distilled water checking the oil, coolent levels of capacity 63 KVA to 320 KVA DG set installed at various locations complete all as specified and as directed by Engr- in- Charge Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii) Proper record & test results of the same shall be maintained as directed (iv) Work shall be carried out at site at different location Details of Plants :- (a) 320 KVA DG Set -01 No (3U Det Sub-Station) (b) 125 KVA DG Set - 02 Nos (01 No at DHQCG-10 S/S + 01 No INS Baaz S/S)
Supply only the following Items of DG Sets of capacity from 63 KVA to 320 KVA to incorporate against each Item of Schedule 'A' here-in-above (a) Engine oil 20W 40 multi grade of make SERVO/KIRLOSKAR
(b) Diesel filter element with 'O' ring suitable for existing DG set
(c) Spin- on filter element for luricanting oil with 'O' ring suitable for existing DG set
(d) By pass filter element with 'O' ring suitable for existing DG set
(e) Air filter element suitable for existing DG set
(f) Fan Belt complete suitable for capacity existing DG set
M & L for AVR (automatic voltage regulator) control unit assembly suitable for 63 KVA to 320 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
Supply and applying Petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make :- Indian oil/ Hindustan Petrolium/ Castrol/ BPCL
Supply and fill distilled water for topping up in lead acid batteries complete all as specified and as directed.
Supply and fill electrolyte of suitable specific gravity for lead acid batteries in sealed container complete all as specified and as directed.
M & L for Battery leads of PVC insulated, multistranded, copper conductor of size 70 sqmm of 1.25 mtr long ach duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations complete including removal of extg unserviceable one complete all as specified and as directed.
M & L for battery teriminal brass clamps including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for repair and calibration of FIP and injectors from authorised dealer for petty repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for following capacities of DG set complete all as specified and as directed. (a) upto 125 KVA DG set
(b) 125 KVA to 320 KVA DG set
M & L for disconnecting all electrical connections from DG set alternator of capacity upto 320 KVA from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out to work shop for Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing & commissioning complete all as specified and directed. Note:- (i) Transporting alternator to workshop at Port Blair and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed is deemed to be inclusive in quoted rates.
M & L for dismantaling the radiator taking to work shop for overhauling & cleaning, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for following capacities of DG set complete all as specified and directed
M & L for Repair/ overhauling of self starting system of DG set including replacement of corbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 24 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
S & F for Time delay relay suitable for 100.00 KVA DG set to 380.00 KVA DG set including removal of extg unserviceable one compete all as specified and as directed. Make:- Simens/ L&T/ ABB/ C & S
M & L for solinoid switch assembly 24 volts suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for DC alternator assembly 24 volts suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for electronic speed control unit assembly 24 volts suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one compete all as specified .
S & F for battery low maintenance lead acid of capacity 12 volts 180 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge. Make:- Exide/ AMCO/ Amaron
M & L for chart/ diagram/ name plates/ details of DG sets made out of bakeite hylem sheet, ISI marked, 3 mm thick , cutting to shape /size including fixing of adhesive transperent filament of red/ blue colour including cutting of filament of letters/ figures/ diagrames/ details of suitable size/ type all as directed inclluding fixing to the wall by wooden screw and PVC hold fast etc complete all as directed and specified. Note :- Matter/ figure/ chart/ diagrames/ letter shall be give by the Engineer- in- Charge
Supply and fill genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified and as directed.
M & L for self starter assembly 12 volts complete suitable for 320 KVA DG setincluding removal of extg unserviceable one complete all as specified and as directed. Make:- Lucas/ TVS
S & F for electric shock treatment coloured chart of English and Hindi languages of size 2' x 3' dully framing with second class hard wood bedding of 1" x 1" with front side PVC transperent sheet and back side with plywood cover of 3 mm thick including suitable hanging arrangement all as directed
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .