Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical GANDIPUR PRANPATTI JAUNPUR | JAUNPUR | JAUNPUR | UTTAR PRADESH | Rejected-Technical Condition Not Fullfill |
Tender Value
₹13.8 L
EMD Value
₹13,800
Closing Date
27 Mar 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EUDC-I, LESA
Office of the SE EUDC-I, LESA
158/EUDC(I)/LESA/2023-24
2024_MVVNL_919811_1
158/EUDC(I)/LESA/2023-24
Open Tender
Electrical Works
Fixed-rate
90 days
in the area under EUDD Rajbhawan
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Central bank of India
₹13,800
20 Apr 2024
22 Mar 2024
27 Mar 2024
22 Mar 2024
27 Mar 2024
22 Mar 2024
Amount
Safe carriage loading unloading with proper stacking of following material from ESC Daliganj to JE dump store.
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
ST POLE 11 MT LONG
LT XLPE Cable 1x240/3.5x240/400 sqmm
ABC Cable (3x50+1x35+1x16)
ABC Cable (3x95+1x35+1x16)
ABC Cable (3x120+1x95+1x16)
11 KV XLPE Cable 3x120 Sqmm.
11 KV XLPE Cable 3x70 Sqmm.
11 KV 3x70 Outdoor Jointing Kit
11 KV Polymarick pin insulator
Top Channel
Dropper Channel
S.S Base Angle
MS Earthing Rod (2540x20 mm)
MS Channel 65x65x6 mm
T-Off Channel
MS Angle
Safe carriage loading unloading with proper stacking of following material from JE dump store to work site.
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
ST POLE 11 MT LONG
LT XLPE Cable 1x630/240/3.5x240/400 sqmm
ABC Cable (3x50+1x35+1x16)
ABC Cable (3x95+1x35+1x16)
ABC Cable (3x120+1x95+1x16)
11 KV XLPE Cable 3x120 Sqmm.
11 KV XLPE Cable 3x70 Sqmm.
11 KV 3x70 Outdoor Jointing Kit
11 KV Polymarick pin insulator
Top Channel
Dropper Channel
S.S Base Angle
MS Earthing Rod (2540x20 mm)
MS Channel 65x65x6 mm
T-Off Channel
MS Angle
Fabrication & erection of S/S type double pole for 11KV line on 11 M long ST pole with fixing of necessary clamps & other acessories like 1 no. top channel 100×50 mm,2 no.MS angle 65x65x6mm,danger board,number plate,barbed wire,TPMO set & D.O.fuse set.
Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5:10 cemend sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr hight & 0.35 mtr wall will be constructed.Rest wall should be 0.23 mtr thick.brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be fiilled from the ground level up to 15 centimeter below from the top of wall,Cement,sand & brick Ballasts should be filled up to 15 centimeter.Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand,cement and stone ballast in the ratio of 1:2:4.The t/fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand. (All the material will be arranged by the contractor .)
S/C Cable laying in normal soil by digging of trench 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
Hoisting of 11KV XLPE cable3x70/120 sq mm on double pole with MS pipe 2 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).
High Pressure testing of 11 KV XLPE cable. Testing equipment will be arranged by the contractor.
Placement of 11/0.4 KV T/Fs from dump place to newly constructed T/Fs plinth & installation,commissioning of 250/100 KVA T/Fs of T/F Plinth and including jumpering with the system ( All the required matrial for above job shall be provided by contractor except T/Fs)
Hoisting, winding and jumpering of of LT cable size 1x240/3.5x240/400 sq mm between LT distribution box/fuse unit & constructed overhead line with proper lugging and clamping
Laying of LT PVC Cable 3.5x240 sq mm single circuit in 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab (Except LT PVC cable)
Stringing,Sagging,winding and jumpering of LT line with AB Cable (3x50+1x95+1x16) conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook,suspension clamp and dead end clamp arranged by contractor .)
Stringing,Sagging,winding and jumpering of LT line with AB Cable (3x95+1x70+1x16) conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook,suspension clamp and dead end clamp arranged by contractor .)
Stringing,Sagging,winding and jumpering of LT line with single phase AB Cable(3x120+1x70+1x16)conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook,suspension clamp and dead end clamp arranged by contractor .)
Construction of retaining wall, fabrication & erection of Wire mesh fencing around Transformer and Distribution Pillar Box with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50x6 mm. Wiremesh of size 10 SWG rectangle type, its painting as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost).
Construction of massonary type Distribution Pillar box with first class brick ballast cement, coarse sand, local sand, brick ballast and MS Round bar of 10 mm dia including Straight MS Angle 50X50X6X750 mm- (All the material will be arranged by the contractor).
Supply of Massonery Type Fuse Unit 2-way.
Supply & Installation of Sintex Type Fuse unit (I/C-01, O/G-02)
Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity. (Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor.
Supply & Fixing of CU L-Piece for 250 KVA T/F
Supply & Fixing of MS Channel
Supply & Fixing of MS Clam of PCC Pole
Supply & Fixing of MS Angel
Supply & Fixing of MS Nut & Bolt with Washer
Supply & Fixing of Aluminium Crimping Lug 120 Sqmm.
Supply & Fixing of ABC Clamp.
Supply of Aluminum / Red Oxide Paint .
Hoisting, winding and jumpering of of LT cable size 1x630/240/3.5x240/400 sqmm between LT distribution box/fuse unit & constructed overhead line with proper lugging and clamping
Removal of connections from the system, safe Loading- carriageunloading of damaged T/F from site to Store Centre Daliganj/ Transformer repair workshop, Aliganj
100 KVA Transformer by tractor trolley/Crane
63/25 KVA Transformer by tractor trolley/Crane
Installation of 11/0.4 KV 63/100/250 KVA T/F (by crane)
All taxess as applicable shall be paid time to timex extra
SIDDHI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .