Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹10.4 L+₹1.0 L (10.8%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹12.5 L+₹3.1 L (32.5%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹13.2 L+₹3.8 L (40.4%)Rejected-AOC H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L4 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
GE(H)-31/2020-21
2020_MES_380424_1
GE(H)-31/2020-21
Open Tender
Miscellaneous Works
Item Rate
330 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹40,000
Yes
31 Oct 2020
24 Sept 2020
24 Oct 2020
24 Sept 2020
22 Oct 2020
9 Oct 2020
60 days
Amount
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks, DB, MCB etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 1.00 (here-in-before) but excluding existing concealed conduit.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including cutting chases in walls and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No 3.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per serial item No. 3.00 (here-in-before) but for one bell/buzzer point controlled by one bell push.
All as per srl item No. 3.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing rigid PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No 9.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 9.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 9.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 9.00 (here-in-before) but bell/buzzer point controlled by one bell push.
All as per item No. 9.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F bell push flush type, 5 Amp 240 Volts.
S&F Bell ding dong type, AC, 230 Volts, single pole.
S&F sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S&F sheet metal enclosure distribution board TP&N, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810336 or equivalent of makes mentioned in list of makes here-in-after .
S&F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S&F MCB SPN, 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F MCB TPN, 63 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 29.00 (here-in-before) but cable drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
S&F LED light fitting 1x18W/20W/22W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. Make : Havells Regal batten Cat Part No REGALBATTENT8UPTO1X22WSSBSWH & LED tube rod Cat Part No PHOTONULTRAE2.01213T8SSTL20WLED865SPC of Havells or Surya Cat Part No SLE BT 20 MS for batten & LED tube rod Cat Part No SLE TL-DS 18 PC Reform of Surya or Cat No LTTB4F20WLEDEW BATTEN for batten & LED tube rod Cat No Cat No LT4F20WLEDT8/WDI of C&S or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 Amp SPN MCB complete all as specified. Make :- Indo Asian Cat Part No 811955 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement street light LED light fitting 30 Watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. Make : Cat Part No ENDURAPEARLSL30WLED757SASYTOPCMP of Havells, Cat No LTESSI30WLED of C&S or Cat Part No PCGLS T1 30 N (Item Code PUBO506026) of Polycab or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Attending of complaints pertaining to unsatisfactory/unfunctional/working state of internal electrification / electric meter to be received through telephone or in person round the clock at MES Service centre for Md Accn of DSTV Pocket-I and Jadunath Vihar of Hisar Mil Stn under GE Hisar by locating the fault from Elect Meter/DB onwards in respect of Sub Main /Point wiring including fixtures and electric meter complete for rectification of faulty wires, battens, conduits, boxes, Main switches, MCB, DBs, electric meter parts and other E/M faults pertaining to particulars instrument/plant/quarters etc including providing insulatiion tape required for the rectification of defect all as directed by Engr -in-Charge.
Note :-(i) S&F in replacement of unserviceable items like fitting/fixtures, MCB's/DB's, tube rod etc shall be measured and paid separately under respective items & details of replacement of items have to be entered in complaint register against complaint number given to contractor. (ii) Complaint pertaining to location of fault in more than one wiring point/sub main wiring/DB etc shall be considered as one complaint. (iii) The complaint slip/job card shall be prepared round the clock by the MES Staff and Supervisor of contractor and shall be handed over to contractor’s tradesmen. Complaint slip shall be got singed by user with name, number and rank and return the same to MES staff by same day. Complaints of emergent nature e.g no light, short circuiting and earth fault etc. shall be attended, round the clock. Other complaints can be attended during normal working hours. In case of complaint has not been attended within stipulated time frame as per its priority nature necessary penalty at the rate of Rs. 250/- per complaint per day shall be imposed and recovered from the contractor.
(iv) Bldgs requiring major nature of work e.g rewiring of complete bldg or major portion shall be intimated to Engr-in-Charge and separate team shall be deployed for the work. (v) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately. (vi) All material required for replacement/repair will be deposited to MES stores and the same will be issued by MES staff to contractor/rep of contractor for rectification / replacement (vii) Contractor shall provide the complain slip booklet required for throughout the contract period containing 100 pages in duplicate of size 5 inch x 8 inch properly binded and printed with their Firm Name and Tele phone numbers as per sample and directed by Engineer in Charge. (ix) Contractor shall be liable to rectified the complaint and shall ensure to detail their workman for attending the complaint round the clock to receive and attend the complaint as per complaint slip at MES service centre.
S&F in replacement socket outlet (enclosure type) suitable for geyser and AC etc complete all as specified and directed.
S&F in replacement sheet metal enclosures with sockets plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amp rating 240 volts etc complete all as specified and directed. Make :- Indo Asian Cat Part No 811955 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs conforming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement sheet metal enclosure distribution board TP&N, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs conforming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810336 or equivalent of makes mentioned in list of makes here-in-after .
S&F in replacement MCB SP, 6 to 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement MCB SPN, 32 to 40 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement MCB TPN, 63 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement bell electric Ding Dong, AC, 230 V, single Pole.
S&F in replacement sheet laminated 3mm thick including cutting required size drilling holes for mounting switch, sockets, regulators all as specified and directed.
S&F in replacement PVC flexible cable 3 core 23/0.0076 copper conductor all as specified and directed.
S&F in replacement rotor type bipin holder suitable for tube light fittings all as specified and directed.
S&F in replacement capacitor 2.5 to 3.15 MFD as per existing capacity of 240 volts AC all as specified and directed.
S&F in replacement switch piano, flush type one way 5/6 Amps single pole mounted all as specified and directed.
S&F in replacement switch piano, flush type two way 5/6 Amps single pole mounted all as specified and directed.
S&F in replacement bell push, flush type, 5/6 Amps single pole mounted all as specified and directed.
S&F in replacement switch piano, flush type one way 15/16 Amps single pole mounted all as specified and directed.
S&F in replacement socket outlet 3 pin 5/6 Amp multi purpose piano, flush type all as specified and directed
S&F in replacement socket outlet 5 pin 15/16 Amp multi purpose piano, flush type all as specified and directed
S&F in replacement ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate all as specified and directed.
S&F in replacement lamp holder of PVC / Polycarbonate type surface for CFL / bulb etc complete all as specified and directed.
M&L for cutting chases in brick wall/PCC walls for taking out blocked concealed conduit and S&F new rigid non-metallic PVC conduit 25mm dia with accessories and making good the surface in cement mortar (1:3) and finish to match the existing surface etc complete all as specified and as directed by Engineer-in-Charge. Note : Wiring required for replacement shall be measured and paid separately under respective items.
S&F in replacement rigid non-metallic PVC conduit 25mm dia with fittings like tees , bends, elbow, reducer, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete fixed on wall / ceiling all as specified and as directed.
S&F in replacement rigid non-metallic PVC conduit 20mm dia with fittings like tees , bends, elbow, reducer, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete fixed on wall / ceiling all as specified and as directed.
S&F in replacement Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan all as specified and directed
S&F in replacement PVC casing and caping of 15mm width all as specified and directed.
S&F in replacement PVC casing and caping of 20mm width all as specified and directed.
S&F in replacement LED tube rod having polycarbonate reform 18/20 W, 4 feet for existing tube light fitting, all as specified and directed. Make : Surya Cat Part No SLE TL-DS 18 PC Reform or Cat No LT4F20WLEDT8/WDI of C&S, Cat No OF PHOTONULTRAE2.01213T8SSTL20WLED865SPC Havells or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement LED light fitting 1x18W/20W/22W, regal batten for LED including ultra bright glass LED Tuberod with very high efficacy, single / double side connection all as specified and directed. Make : Havells Regal batten Cat Part No REGALBATTENT8UPTO1X22WSSBSWH & LED tube rod Cat Part No PHOTONULTRAE2.01213T8SSTL20WLED865SPC of Havells or Surya Cat Part No SLE BT 20 for batten & LED tube rod Cat Part No SLE TL-DS 18 PC Reform of Surya or C&S Cat No LTTB4F20WLEDEW BATTEN for batten & LED tube rod Cat No LT4F20WLEDT8/WDI of C&S or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement sunk type pressed steel terminal box of size 8" x 10" (made as per IS 5133).
S&F in replacement sunk type pressed steel terminal box of size 7" x 4" (made as per IS 5133).
S&F in replacement sunk type pressed steel terminal box of size 4" x 4" (made as per IS 5133).
S&F in replacement wooden board of size 8" x 10" made out of seasoned second class hardwood.
S&F in replacement wooden board of size 7" x 4" made out of seasoned second class hardwood.
S&F in replacement wooden board of size 4" x 4" made out of seasoned second class hardwood.
S&F in replacement single core copper conductor cable 1.5 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
S&F in replacement single core copper conductor cable 2.5 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
S&F in replacement single core copper conductor cable 4.0 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
S&F in replacement single core copper conductor cable 6.0 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade.
M/s INDER CONSTRUCTION COMPANY
M/S D.N Choudhary
virendra constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .