Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹49.2 L+₹1.2 L (2.52%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹49.2 L+₹1.3 L (2.70%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹49.4 L+₹1.5 L (3.02%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹49.4 L+₹1.5 L (3.10%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
3 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
PROVN OF BATHING POINT 10 X 10 AT OTM ACCN BLDG NO P 658 FOR BATHING OF TPS OF ARMY AD RECORDS INCLUDING CERTAIN MINOR WORKS AND OTHER ALLIED WORKS AT GMS UNDER GE I GOS
2022_MES_538158_1
8000/13/2022-23/0912/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹74,000
Yes
29 Aug 2022
14 Jul 2022
5 Aug 2022
14 Jul 2022
3 Aug 2022
28 Jul 2022
Amount
Excavation in post holes (or similar holes) each not exceeding 0.50 cum, in soft/loose soil, getting out, returning filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering or removing surplus soil to a distance not exceeding 50 m & making good surface complete all as specified & directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling & mass concrete complete all as specified & directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1998 grade St-240 complete all as specified & directed.
M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
M&L for preparation of new or previously untreated surfaces of any description, over 10 cm in width or girth, not otherwise described & applying two coat of synthetic enamel (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified & as directed.
M&L Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified & directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
M&L for Machine pressed precast cement concrete kerb stones of grade M-30 of size 450 mm x 300 mm x 150 mm as used in road kerbs and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for preparation of new concrete surfaces and applying two coat of synthetic enamel paint on concrete surface over a coat of acrylic primer complete all as specified and directed.
M&L for Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Excavation in trenches in soft / loose soil, not exceeding 1.5 metre wide & not exceeding 1.5 metre deep; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan including getting out, complete all as specified & directed.
Excavation in trenches in soft / loose soil, not exceeding 1.5 metre wide & exceeding 1.5 metre & not exceeding 3.00 metre deep; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan including getting out, complete all as specified & directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as speified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, Flat, with fair finished surfaces complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions , Flat with fair finished surfaces complete all as specified and directed.
M&L for 16 mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
M&L for Rendering 10 mm thick in cement mortar 1 : 4 for fixing of wall tiles complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed.
S&F Mild steel, plain, 1.25 mm thick sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
M&L for Old Size Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Surface excavation n.exc 30 cm deep and getting out in Soft/Loose soil complete all as specified and directed.
M&L glazed ceramic colored tiles (Premium quality) 200x300x6 to 7mm thick coloured on vertical surface such as dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tile including rendering 15 mm thick on brick or stone masonry surfaces finished fair and even to recieve tile in CM 1 : 4 complete all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 20mm thick screed bed in CM 1 :6 complete all as specified and directed.
M&L for Machine cut kota stone slab flooring mirror finished 15-18 mm thick (each slab not less than 0.32 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 20 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
Removing surplus excavated earth (soil) to a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface, finishing even and smooth without using extra cement but using water proofing compound complete all as specified and directed.
S&F 15mm dia GI tubing medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 15mm bore bib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube complete all as specified & directed.
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube complete all as specified and directed.
M&L for PC C 1:3:6 Type C-2 using 40 mm graded stone aggregate as in surface Channels and drains complete all as specified and directed.
M&L Extra forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds,mitred/stopped ends etc complete all as specified and directed
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for random rubble masonry walling well bonded, bedded, solidly hearted, uncoursed built in CM 1:6 complete all as specified and directed.
M&L for Rendering 20 mm thick in CM 1:6 on stone masonary surface, finishing even and smooth without using extra cement complete all as specified and directed.
M&L for add or deduct for each 25 mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for Plain Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/ hard standing surface finished even and fair complete all as specified and directed.
M&L for Finishing cement concrete even and smooth using extra cement complete all as specified and directed.
S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and directed
S&F in repair reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 300mm dia complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 300 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm signle core PVC insulated unsheathed copper FRLS multi stranded copper conductor cable in and including PVC casing caping of size 20/25 MM ISI marked inclusive of tees, bend, elbows etc upto and including GI sunk boxes of size 1.2 mm thick and 60mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switch/ socket of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal incuding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for following:- (a) One light point controlled by one , one way switch 5 Amp
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L Switch piano flush button single pole one way 6 Amps, complete all as specified and directed.
M&L for Ceiling rose 3 terminals of PVC/ polycarbonate, as per relevant IS code, ISI marked isolated body complete all as specified and directed.
S&F LED tube light fitting 4ft, 20 watts, 220 volts, 50 Hz complete all as specified and directed
S&F Sheet metal enclouser for DB's when MCBs to be used single pole neutral 4 way with 200 Amp rated bus bar double door complete all as specified and directed.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 32 Amps SPN and current carrying capacity in the MCB DB complete with connection testing and commissioning.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
M&L for Wiring for circuit/submain wiring alongwith earth wire with 2x2.5 Sqmm + 1x1.5 Sqmm FRLS in PVC insulated copper conductor, single core cable in surface / recessed as required complete all as specified an directed.
M&L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M&L for GI tube medium grade of size 32 MM dia laid for protection of cable/ earth strip complete all as specified an directed
M&L for Wiring for circuit/submain wiring alongwith earth wire with 2x1.5 Sqmm + 1x1.0 Sqmm FRLS in PVC insulated copper conductor, single core cable in surface / recessed as required complete all as specified an directed
S&F new generation post top energy saving, environmental friendly, long life awsthetically designed with symmetrical light, distribution, spun aluminium landscape luminarie with high power LEDs as light source with capacity 25 Watts, 220 volts, 50 Hz new generation complete all as specified and directed.
M&L for PVC gang box two module eco friendly durability surface gang box complete all as specfied and directed
M & L for carrying out in repairs primary & secondary injection test of 33 KV or 11 KV indoor /outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning incl submitting the test report complete all as specified & directed.
M & L for carrying out in repairs primary & secondary injection test of 11 KV indoor /outdoor type RMU's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning incl submitting the test report complete all as specified & directed.
M & L for servicing in repairs 11KV VCB / bus coupler by dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning all as directed. (Note : New spares will be measured and paid separately under relavent item of this schedule)
S&F in repalcement of Earth Fault and over current relay of suitable model and make as per existing complete all as specified and directed.
S&F in replacement of Digital type power factor indicator meter complete all as specified and directed
S&F in replacement of Digital type Voltmeter / Ammeter as per suitable make and size to accommodate the existing complete all as specified and directed.
S&F in replacement of LED type indicator lamp assembly complete all as specified and directed
S&F in replacement of Epoxy insulators bushings for incoming / out going cables / bus bar supports as per existng size of VCBs complete all as speicified and directed
S&F in replacement of Gear system assy complete with handle for charging / discharging of VCBs complete all as specified and directed
S&F in replacement of Spring charging motor for VCBs complete all as specified and directed.
S&F in replacment of Metering and protection current transformer epoxy/resin filled of 11 KV grade of ratio 100-50/5 class = 5P, 10/1 25 VA draw out type with necessary mounting and connected items.
S&F base insulator epoxy for RMU's complete all as specified and directed
S&F in replacement of CTs for RMU's of suitable make and model to accommodate the existing complete all as specified and directed
S&F in replacement of charging spring with shaft with accessories for RMU's complete all as specified and directed
S&F in repairs tripping coil for RMU's complete all as specified and directed
S&F in repairs pressure bar for RMU's complete all as specified and directed
S&F in repairs main shaft pully for RMU's complete all as specified and directed
S&F in repairs auxillary relay for RMU's complete all as specified and directed
S&F in repairs for complete rewiring of RMU's with suitable size of copper cable single core complete all as specified and directed
S&F in repairs for main shaft coil for RMU's complete all as specified and directed
S&F in replacement of monometer for RMU's complete all as specified and directed
S&F in repairs dry cell battery of capacity 2 Volts 100 amps of make Exide model No UPST 100 or equivalent with complete wiring upto the UPS complete all as specified and directed.
S&F in replacement of gear connector for RMU's complete all as specified and directed
S&F in replacement of operation attachment control for RMU's complete all as specified and directed
S&F in replacement of bearing for main shaft (sealed bearing) for RMU's complete all as specified and directed.
S&F in replacement of self powered protection rellay with assembly parts for RMU's complete all as specified and directed
S&F in repalcement of inverter with pure sine wave output with automatic battery charging, automatic overload, battery low, heat up & short circuit protection sense complete all as specified and directed.
M/s Ats Electricals
M/s MAA BHAIRABI ENTERPRISES
ABC CONSTRUCTION COMPANY
HARAGOURI SUPPLIERS
G.KRISHNA MURTHY AND PARTNERS
M/S SIWALIK AND CO
MM ENGINEERING SYSTEMS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .