Above/Below/Par
SIGNAL
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. : Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any Signalling work involving trenching, cable laying, termination and outdoor wiring. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/ 40 / 60% (as the case may be) criteria of similar nature of work.
22 conditions · 13 needing a document upload
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Signalling work for strengthening of Signalling infrastructure in LKO-SLN-ZBD section of Lucknow Division of Northern Railway in view of upcoming Inspection.
106-Sig-Tender-46-2025-26~NR
106-Sig-Tender-46-2025-26
Open
Works - General
90 Days
Lucknow, Uttar Pradesh
₹0
₹2.3 L
2 Jan 2026
12 Dec 2025
19 Dec 2025
162 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,51,49,485.38 | ||
| — | 2000.00 | — | — | ||
| Excavating and refilling of trench to the level of ground with rammed earth asper Drg. No.(NR/S&T/Con/1.1/97A) so as not to form a drain 0.3 Mtrs wide & 1mtr deep on both side of the station along side the track. It shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes. | — | — | — | 88,520 | |
| — | 3000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per attached guidelines (Drg. No.(NR/S&T/Con/1.1/97A) or latest on signalling cable laying and as per cable route plan approved by Railways through trenches, RCC pipe, DWC pipe, GI pipe etc and meggering of cable before and after its laying of all type of outdoor cables. Contractor have to transport cable from any store of LKO division to site carefully. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways, as per instructions by Consignee. | — | — | — | 16,320 | |
| — | 16000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) or latest and as per instruction of the site Engineer. | — | — | — | 93,280 | |
| — | 500.00 | — | — | ||
| Boring and trenchless cabling along with supply and insertion of HDPE/DWC self lubricated pipes as per RDSO Spec no. RDSO/SPN/204/2011 Ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by Engineer Incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. Inspection-RITES for Supply of DWC/HDPE pipe. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers withrubber O ring, 2. Spacers, 3. Tees. 4. Bend. 5. End Cap(1 no. =6mtr ,Straigh tpipe). (A) The cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (B) The rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account than the rate quoted above. (C) The Pipeis to be laid underrailway track/road /culvert. All necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizontal and vertical direction. (D) The rate shall be inclusive of direction and protection of underground utilities encountered during boring. (E) The payment for boring shall be made only when DWC/HDPE pipe are laid in the bore. | — | — | — | 6,53,245 | |
| — | 20.00 | — | — | ||
| Supply of Table for Block Panel/Office table size (1000 x 600 x 750mm), Key Board pull out tray, drawer and top made off MDF Model C-13. Make: Godrej or better. Inspection- Consignee | — | — | — | 1,47,082.2 | |
| — | 10.00 | — | — | ||
| Supply of Fiber glass reinforced plastic Plates of size 530x960x10 mm as per instruction of Engineer incharge. Inspection- Consignee | — | — | — | 19,690 | |
| — | 10.00 | — | — | ||
| Supply of ESM furniture of Godrej or similar reputed make as per approval of engineer consisting of the following: 1. Executive revolving bearing series low back floating chair with normal arms cushioned Chair : 1No. 2. Executive Table size 72x36x30" with 3 drawers one side, lockers cabinet on other side : 1No. 3. Visitor chair seat & back cushion with high density Foam with plastic PVC handle capsul type Flat pipe duly Painted black : 3Nos.4. One Steel Almirah of size 48"x30"x17" with lock and handle arrangement for record keeping at station. Inspection : Consignee | — | — | — | 4,61,493.4 | |
| — | 54.00 | — | — | ||
| Supply of 3 phase Manual changeover switch 63Amps/100Amps. Siemens/Havells or similar Iron Clad switch. Inspection- Consignee | — | — | — | 3,24,511.38 | |
| — | 25.00 | — | — | ||
| Casting, concreting, curing of foundations of size (400mmx300mm) at surface and 1000mm deep and erection of retroreflective SLB/BSLB/SB/ calling on boards/Goods Warning Board/Passanger Warning Board as per Drg. No. NR/S&T/CON/7.4/97 or latest & provisions of SEM. It includes supply of retroreflective SLB/BSLB/SB/ calling on boards/Goods Warning Board/Passanger Warning Board. The SLB/BSLB shall be as per approved Drg. No.SA-2373 or latest. Calling on board should be as per Drg NO: NR/S&T/D&D/01/2022 or latest. Inspection by : Consignee for supply portion | — | — | — | 2,45,668 | |
| — | 50.00 | — | — | ||
| Fabrication, Supply and fixing of retroreflective P/G/C/ markers with complete fittings as per approved Drg. No. NR/S&T/CON/6.2/97or latest. All material required for the job such as MS sheet, MS angle. Nut and bolts, paint and painting materials will be supplied by the Contractor. The P and G markers shall be as per Drg. No. S 23456 (Adv) & SA 23477 (Adv) or latest respectively. Inspection : Consignee for supply portion. | — | — | — | 30,704 | |
| — | 3500.00 | — | — | ||
| Fencing Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | — | — | — | 3,91,825 | |
| — | 4050.00 | — | — | ||
| Supply, fixing and wiring of PPTC Fuses /Bourn/Fuzetech/Little Fuse or similar. Inspection by-Consignee | — | — | — | 29,565 | |
| — | — | — | tyco/Raychem | ||
| — | 30.00 | — | — | ||
| Shifting of Apparatus case Single: It includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at site. The work includes ensuring the safety of the signalling system, releasing the cables coils to give access for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor). | — | — | — | 1,42,663.2 | |
| — | 30.00 | — | — | ||
| Shifting of Apparatus case half: It includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at site. The work includes ensuring the safety of the signalling system, releasing the cables coils to give access for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor) | — | — | — | 94,419 | |
| — | 27.00 | — | — | ||
| Cleaning, scrapping, painting & lettering of all newly installed & existing gears such as signals, point equipment, track circuit equipment with TC No. on rail, app. cases, JB, TLJB, point rodding, cranks, compensators etc. including gate equipment if existing in station section as per the provision of IRSEM All paints (ISI marked) with IS specification No. IS:15489:2004 Asian /Burger/ Nerolac or similar make. shall be approved by Railway Engr.and painting materials to be supplied by the contractor. This includes writing, and painting requirement of all indoor and outdoor gears along with marking of all circuit Nos. near terminal and terminal boards/rack in app.cases, Jn.boxes, relay room, SMs room, writing of relay nomenclature, fuse Nos. and equipment nomenclature as per the approved plans and as per provision of IRSEM. | — | — | — | 7,15,245.93 | |
| — | 20.00 | — | — | ||
| Cleaning, scraping, painting and lettering of all newly installed and existing gears by the contractor for existing/new Level Crossing Gates.This includes supply of all painting materials and marking of all the ckt particulars near terminal on terminal board/in apparatus case/Jn. boxes and fuse nos, relay and equipments nomenclatures as per approved terminal chart and provisions of SEM. All paints (ISI marked) with IS specification No. IS:15489:2004 Asian /Burger/Nerolac or similar make. shall be approved by Railway Engr.and painting materials to be supplied by the contractor. | — | — | — | 4,40,381 | |
| — | 3000.00 | — | — | ||
| Supply of 4 conductor dis-connect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Rev. 3.0 or latest. Material to be supplied from RDSO approved firm. Inspection : RDSO | — | — | — | 3,92,250 | |
| — | 30.00 | — | — | ||
| Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 4,304.1 | |
| — | 150.00 | — | — | ||
| Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 2,721 | |
| — | 150.00 | — | — | ||
| Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 2,287.5 | |
| — | 40.00 | — | — | ||
| Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately. | — | — | — | 2,96,738 | |
| — | 30.00 | — | — | ||
| Strengthening of foundations of signals, Full/Half location boxes up to a height of 30 cm, by carrying out the earth work around the foundation, ramming of the earth, carry out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank. | — | — | — | 17,613 | |
| — | 1000.00 | — | — | ||
| Earth work for excavation and refilling around location boxes and signals etc. where necessary including 50M lead and 1.5M lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earth work should be well rammed including breaking of clods, levelling and dressing etc. as per instruction of Engineer at site. | — | — | — | 1,55,900 | |
| — | 50.00 | — | — | ||
| Brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Engg representative.) | — | — | — | 1,32,222 | |
| — | 50.00 | — | — | ||
| Concreting unschduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. It also includes the excavation of earth as required at site and as per instruction of site incharge. The volume in cubic metres shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement coarse sand and aggregate 25mm are to be supplied by the contractor. | — | — | — | 1,85,817.5 | |
| — | 120.00 | — | — | ||
| Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, Dismantling any infringing structures, clearing and removing debris etc., with all lead and lifts etc., complete and as per the instruction of railway representative at site. | — | — | — | 1,30,188 | |
| — | 200.00 | — | — | ||
| Maintenance of Main/Tail signal cable/ signalling gears and Gates. The work organise by team is Main signal cable test in disconnection, Tail signal cable test in disconnection/ maintenance of signalling gears/gates, The team to be provided for this work should comprise of Black Smith-1 no, Fitter-1 no and helper-4 nos. It also includes any work of signalling gears. Any other work as per instruction of railway Engineer. All T&P required to execute the work will be supplied by the contractor. unit days means team per day. | — | — | — | 7,09,494 | |
| — | 700.00 | — | — | ||
| Supply of 35 Sq. mm PVC insulated Single core Multi strands copper conductor (Red/Black/Green) as per IS: 694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection- RDSO | — | — | — | 1,50,346 | |
| — | 500.00 | — | — | ||
| Supply of 10 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection- RDSO | — | — | — | 45,805 | |
| — | 600.00 | — | — | ||
| Supply of 16 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as perIS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection- RDSO | — | — | — | 75,732 | |
| — | 1.00 | — | — | ||
| Supply of wiring materials asper IS Spec. No. 2465/1984 with latest Amend. and IS694/2010 or latest Copper wire,PVC insulated sizes as under. (a) Power wire 1*6 Sq. mm (No ofstrand-85 & diameter of strand-0.30 mm + - 0.00, insulation thickness 0.80 mm Normal conductor Resistance 3.30Ohm/Km (RED & BLACK colour50% each) Material to be procure from RDSO approved firm. Test parameters are as per(IRS)/76/89(Amdnt.3). Inspection : Consignee | — | — | — | 58,651.01 | |
| — | 54.00 | — | — | ||
| Supply of Exothermic welding materials for connecting the existing ring earth with new maintenace free earth. (Cad weld or similar). Inspection- RDSO | — | — | — | 87,300.18 | |
| — | 120.00 | — | — | ||
| Supply and installation of earth electrodes as per std.practice. The item includes digging of pitin earth, 3 Mtrs. deepand fixing earth electrode pipe.Casting of cement concrete enclosures as per drg. No.(NR/S&T/CON/6.4/97) or latest. The soil treatment shall be done as per std.practice. The item includes provision of mild steel flat of size35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument,cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earth connection Signal & location boxes to be done Drg.No. 19-D6 of IRSEM App II or latest. Complete materials such as earth electrodes as per Drg. No. (NR/S&T/CON/6.3/97)or latest, cement, wiring material, nutbolt for connection & mild steel flat of size minimum 35mm x6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection by - Consignee for supply of earth electrode. | — | — | — | 4,06,309.2 | |
| — | 150.00 | — | — | ||
| Supply of FRP type TLJB as per drawing SA 20101/M made of FRP material (FRP material conforming to RDSO/SPN/151/97 or latest) complete with 450 mmlong 25 mm dia pipe. Inspection-Consignee | — | — | — | 1,55,263.5 | |
| — | 150.00 | — | — | ||
| Fixing of track lead junction box (TLJB) due to repositioning of old TC as per Drg. No. NR/S&T/CON/3.2/97. This also include erection of track lead junction box & terminating the cable. The concrete foundation for fixing angle iron of TLJB shall be casted in cement , aggregate and sand mixture of 1:3:6 ratio. This includes excavating ramming , curing and plastering of foundation with mixture of 1:4 ratio. Cement , sand , aggregate Iron angle , nuts & bolts are t be supplied by the contractor. | — | — | — | 43,215 | |
| — | 250.00 | — | — | ||
| Preparation of Panel Diagram, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad. The drawings shall be prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print . The drawings shall be checked and returned by Railways indicating corrections if any. The correction shave to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in Pendrive. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. c. For preparation of soft copy from U size hard copy. (The Rate is for per Sheet) | — | — | — | 2,11,962.5 | |
| — | 250.00 | — | — | ||
| Supply of Original Tracings of A-3 Size. NOTE:- For Drawings larger than A-3 Size, payment shall be made in multiples of A-3 Size. Inspection : Consignee | — | — | — | 19,660 | |
| — | 20000.00 | — | — | ||
| Loading, Leading & unloading of materials from store to another store as per instruction of consignee. All the material to be transported carefully without damage. Contractor have to do proper stacking of material and prepare list of material. | — | — | — | 1,04,800 | |
| — | 200.00 | — | — | ||
| Provision of Cement concrete enclosure for Earth electrode as per approved drawing RDSO Drawing No. SDO/RDSO/E&B/001. All the sundry materials to be supplied by the contractor. | — | — | — | 96,934 | |
| — | 135.00 | — | — | ||
| Supply of insulation for 'L' bracket for IRS type point machine fitting Consisting of Insulation plate- 01 No., Ferrules- 2 Nos. Washers- 4 Nos. (Material Nylon 66).as per RDSO spec IRS- 23 and S-40 with latest amendment. Inspection by consignee | — | — | — | 39,236.4 | |
| — | 135.00 | — | — | ||
| Supply of insulation for 'P' bracket for IRS type point machine fitting consisting of Insulation plate- 01 No. , Ferrules- 2 Nos. Washers- 4 Nos. material nylon 66 as per RDSO spec IRS- 23 and S-40 with latest amendment. Inspection by Consignee. | — | — | — | 1,00,072.8 | |
| — | 270.00 | — | — | ||
| Supply of William stretcher bar insulation set suitable for ground connection RDSO Drg n. T-1.367, T-10368, T-10384 to IRS-23 and S-40 with latest amendment completed with nut bolts etc..The material should be procured from RDSO approved firm. Inspection by Consignee | — | — | — | 1,05,121.8 | |
| — | 270.00 | — | — | ||
| Supply of Gauge tie plate (GTP) insulation as per RDSO Drg.no. Plate T-10372/Alt or latest . 2,T-10371/Alt.2 ,T-10368/Alt. and to IRS S-23 and S-40.Inspection by Consignee. | — | — | — | 73,834.2 | |
| — | 108.00 | — | — | ||
| Supply of Retro Reflective tape of reputed make like 3M or similar. Approx. Size: 50.8 mm x 100 Mtr rolls conspicuity marking tape (Yellow & Red) as per instruction of consignee. Inspection : Consignee | — | — | — | 1,01,092.32 | |
| — | 200.00 | — | — | ||
| Wiring of relays in relay room/relay huts as per approved wiring diagrams. All material required will be supplied by contractor including indoor cables and wires of 1x1, 1x0.6, 3/.029, 16/0.2, 40x0.6, 40x1, 60x0.6, 60x1 dia.of copper conductor as per NR practice conforming to latest IRS S76/89 (Amd.3) or latest available specifications . This also includes soldering, dressing, bunching, lacing, fixing of relay bases etc. and provision of LED indication box of vital relays in relay room if required and provision of potential free contacts of all relays on tag block for data logger as per instruction of site Engineer. | — | — | — | 92,244 | |
| — | 20.00 | — | — | ||
| Supply of complete set of point rodding (Ground connection) for 220 mm stroke point machines for thick web switches conforming to RDSO specification no. IRS:S 5-62 and as per Drg. No. RDSO/S 11000, RDSO / S 3454 & RDSO/S-3395 or latest as applicable. (coal Bangal for smithy work, all type of nuts & bolts and Lugs as required also to be supplied with each set). (Inspection- Consignee) | — | — | — | 4,85,138.8 | |
| — | 10.00 | — | — | ||
| Fabrication & Supply of complete set of point rodding for point machines of IRS type or its equivalent type as per RDSO drg. No. SA 8800-01 (Adv) or latest along with 'P' brackets and 'L' bracket required (Coal & Smithy work), all type of nuts & bolts and Lugs as reqd. also to be supplied by contractor with each set) Inspection : Consignee | — | — | — | 1,07,092.6 | |
| — | 50.00 | — | — | ||
| Provision of Lead wool compound for filling the gap between signal post and signal base. Inspection :Consignee. | — | — | — | 17,635 | |
| — | 10.00 | — | — | ||
| Supply of Electrically Operated Lifting Barrier complete set suitable for 110VDC/24V DC (option to be specified in tender specifically of either 110 V DC or 24V DC) supply without hand generator back up & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with latest amendment. One set consisting 02 Nos of Barriers of length 09.76 Mtrs. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2 as below 10.1 Following spares shall be supplied alongwith each set (02 nos.) of Electric lifting barrier as per requirement of the purchaser i) GI boom - 1 no. complete. ii) Belt - 1 no. iii) Crank handle - 1 no. iv) Motor Contactor - 1 no. v) Motor protection MCB- 1 no. vi) Push button complete- 2 nos. vii) Limit switch - 3 nos. (1 lever type and 2 top roller type) viii) Fuses used - 2 sets 10.2 Tool kit consisting of standard sizes of wrinch/ spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier. Inspection: RDSO | — | — | — | 33,68,865.6 | |
| — | 10.00 | — | — | ||
| Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc. | — | — | — | 5,07,525.2 | |
| — | 5.00 | — | — | ||
| Fixing in position and commissioning of sliding barrier boom set (1 set will consist of two sliding barrier booms, one for either side of track) this includes carrying out civil masonry work at site like digging of pits for foundations, casting of RCC foundations, fixing of foundation bolts and putting the casted blocks on proper alignment ( 10 Nos at each site of size 18"x18"x36"). This also includes loading, unloading and leading of all the material to site of work from the store of SSE Signal. Sliding barrier has to be made ready in complete working order as per instructions of Site engineer. Sliding gate, E type lock, T-2 lock and wiring materials will be supplied by the railways and all other material including cement, sand, aggregate (Ratio of cement, coarse sand and aggregate should be 1:3:6), nut bolt etc will be supplied by the contractor. | — | — | — | 1,90,486.35 | |
| — | 20.00 | — | — | ||
| Fixing and wiring complete KLCR and its box in location boxes, supply, installation, wiring of heavy duty push button, LED indicator on MS sheet as per N.R. practice for crank handle locking. This work includes fixing & wiring of magneto telephones as per instructions of the site Engr. This includes all materials such as heavy duty push button, LED indicator (10mm), MS sheet of 4.5 mm thick, nuts and bolts, fixing materials for the magneto telephone, and wiring materials to be supplied by contractor. Inspection : Site Engineer | — | — | — | 2,08,554.4 | |
| — | 500.00 | — | — | ||
| Supply of electric fuse complete with fuse block (base) for Railway signalling non deteriorating type lowvoltage fuse assembly 2Amp/4Amp/16Amp. to suit Specn. No. IRS: S-78/2006 and fuse block made of PBT/Polycarbonate as per IRS:S-75/2006 (Rev.2 & Amd.2) and drg no. 23748 (IRS), Alt-4 or latest. Fuse block shall besuitable for round head type fuses. Inspection : RDSO for both Fuse and Fuse block | — | — | — | 94,695 | |
| — | 500.00 | — | — | ||
| Supply of round head type non-deteriorating type low voltage cartridge fuse as per RDSO Specn.No.IRS:S 78/2006 or latest and Capacity 2/4/6/10A/16A/20A Amp. (material will be supplied only from approved vendors of RDSO) Inspection- RDSO | — | — | — | 27,750 | |
| — | 20.00 | — | — | ||
| Supply & Installation of lightening & surge arrestors Indicative type of Class B & Class C suitable for single phase power supply in TT (Earth to earth) net work as per amdt 5 of RDSO Specification RDSO/ SPN/ 165/ 2012 (Ver.3) or latest & as recommended by RDSO vide letter No. STS/E/IPS/Genl dt. 27/1/2006. (RDSO Spec no.RDSO/TC/98/2011/Rev 0.0 ). Installation & commissionig of above Class B & Class C arrestors, These din rail mountable devices along with a 63 amp HRC fuse & fuse base shall be fixed in a wall mountable cabinet of minimumsize of 250mm (w) x 450mm (h) x 150mm (d). This box shall be made using Fire retardent fibre box/MS sheet steel of 20 gauge or better with IP 31 protection & powder coating. A door knob shall be provided to open the front door to asses the fuse. provision shall also be provided to view the working condition of class "C" arrestors from the front side of the cabinet. All the internal power wiring shall be made using aminimum of 10 sq mm pvc cable & termination shall be suitable for connecting 16 sq mm copper cable. The PF contact of Class C arrestor shall also be wired using aminimum cable of 2.5 sqmm & terminated on suitable terminal block. The Earth cable shall be connected to the equipottential bus bar using an insulated Cadmium bronze cable of 3/16 inch as per RDSO specification IRS-S:103-2004 using exothermic welding .All the material used for exothermic welding will be of RDSO approved/recommended make & all the tools & Tackles required shall be arranged by contractor only. Inspection : RDSO/RITES | — | — | — | 6,80,302.8 | |
| — | 200.00 | — | — | ||
| Supply of PVC channels /Conduit pipes with fixing accessories of the following size :- PVC conduit pipe 1" dia, Inspection : Consignee | — | — | — | 6,410 | |
| — | 200.00 | — | — | ||
| Fixing of 1"/2" PVC channel/conduit pipe 1" dia on proper clamps and screws and indoor cable laying as per instruction by Site Engineer | — | — | — | 2,252 | |
| — | 350.00 | — | — | ||
| Supply of round head type non-deteriorating type low voltage cartridge fuse as per RDSO Specn.No.IRS:S-78/92 or latest and Capacity - 0.63 Amp. (material will be supplied only from approved vendors of RDSO). Inspection- RDSO | — | — | — | 19,271 | |
| — | 500.00 | — | — | ||
| Supply of Panel Indication LED Red, Green, Clear of reputed make compatible with existing panel and as per site engineer. Inspection by consignee | — | — | — | 20,415 | |
| — | 27.00 | — | — | ||
| Supply of Safety lock Godrej or Navtal make size as approved by site engineer. Inspection- Consignee | — | — | — | 2,692.71 | |
| — | 10.00 | — | — | ||
| Supply of seal plier as per sample got approved from site engineer incharge. Inspection- Consignee | — | — | — | 9,379.5 | |
| — | 27.00 | — | — | ||
| Fabrication & fixing of cabin diagram/SWRD/Gate diagram of size 1500 mm X 700 mm made of half inches MS Plywood with as per std. practise of NR. | — | — | — | 1,67,085.72 | |
| — | 35.00 | — | — | ||
| Supply of White Board of Size 2'X 3' feet and as per site engineer. Inspection- Consignee | — | — | — | 37,275 | |
| — | 135.00 | — | — | ||
| Supply of Do's & Don't (Salient Features) board, Station at a glance, Size 2'X 3' feet and as per site engineer. Inspection- Consignee | — | — | — | 1,05,749.55 | |
| — | 35.00 | — | — | ||
| Supply of Notice Board of Size 2'X 3' feet and as per site engineer. Inspection- Consignee | — | — | — | 37,916.55 | |
| — | 4.00 | — | — | ||
| Installation, erection and wiring of 2/3/4 aspect LED lit colour light signal including 1/2/3/4/5/6 way Jn. type route indicator and stencil type/theater type route indictaor which also include fixing of route indicator on the top of signal post or on offset bracket including fixing of offset bracket wiring the whole unit, focussing of signal and route indicator. Supply of unit Jn./stencil/Theater and off set bracket by contractor covered else where. All other wiring and fixing materials, 'U' bolt etc. will be supplied by the contractor. | — | — | — | 17,545.32 | |
| — | 10.00 | — | — | ||
| Fixing, wiring, testing & adjustment of 143mm/220mm throw point machine complete as per standard practice. It also includes:- (i) Fixing of switch extension P bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle.(ii) Wiring inside the point machine, erection of 30/40 line junction box as per Rly. drawing, provided with terminal strips for cable termination. (iii) Supply & Fixing of GI pipes with flange for taking cable in to point machine and Jn. Box through gland/ GI pipe.(iv) Complete material for insulation viz. point insulation material, junction box, GI Pipe/gland pipe, wiring material, nut & bolts of various sizes, angle iron of size (75mmx75mmx10mm) , MS channels for fixing of machine, lugs for the point rodding and insulation material for the stretcher bar 90R/52kg/60kg as per RDSO Drg. no. SA-23171 ( Adv.) Alt. 1, SA- 23172 ( Adv.) Alt. 1 or latest will be supplied by the contractor.(v) Smithy and fitting work required at site for complete installation of gauge tie plate and insulation of GTP as per Drg. No. NR/S&T/CON/7.6/97 and William stretcher bar ( if required) will be done by the contractor. Machine will be overhauled by the contractor if required. (vi) This includes removal of existing gears and fixing themachine at raised level on channel as per standard practice to avoid flooding wherever required. (vii) Supply of ground connection of electric point machine, Non insulated GTP and CTP extension plate, Junction box and stretcher bar shall be made available by the railways. Work at site shall be inspected by site engineer. | — | — | — | 93,366.7 | |
| — | 1.00 | — | — | ||
| Installation and commissioning of SSDAC complete as per RDSO specification No.RDSO/SPN/176/2005(ver 2)/RDSO/SPN/177/2000 (ver2) or latest. The axle counter will be MSDAC/SSDAC section type with 2 or more detection point and it is possible to install without trolley protection track circuit. Installation to be done by OEM authorised Engineer as per the installation manual of the OEM. This include supply and installation of HDPE Pipe GI pipe shelded cable/wires masonary & wood work in location box relay room ASM Room it also include of fixing of resetting box in ASM office with all wooden and masonary work." | — | — | — | 54,179 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of Block Proving by Axle Counter (BPAC) using Block panel and UFSBI for Double line Operation as per Spec No. IRS: S 105/2012, ver.0 with latest and amdt. | — | — | — | 88,500 | |
| — | 8.00 | — | — | ||
| Supply of cable/wire indoor copper conductor single/multi core plain annealed high conductivity PVC insulated unarmoured as per Spec. no. IRS-S/76/89 (Amd-3) or latest amendment of the following sizes:- (i) Wire 1*1mm/16*0.2mm (to be procured From RDSO Approved Source only) Inspection by Consignee | — | — | — | 63,545.36 | |
| — | 50.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding/ cable carrier of angle iron of size 35mmx 35mm x 5mm andflat of size 25mmx3mm as per instructions of Engineer at site. The space between two flats shall be 25cm or less as per site requirements . All material required for scaffolding / cable carrier to be supplied by contractor. All fixing material like bolts nuts, washers, insulators, sand , cement & concrete etc, will be supplied by the contractor. This also includes insulating flat strips, cleaning, priming by red oxide, painting by ISI mark paint and writing of description of relays by ISI mark paints. Inspection-Consignee for supply portion | — | — | — | 26,796.5 | |
| — | 150.00 | — | — | ||
| Supply of Insulation sets for ground connection for made of nylon-66 for 220mm throw point machine as per Specn. No. IRSS-40/84 or latest.one set consisting as follows: 1) Insulating Washer drg. No. S-8640-12 Nos, 2) Insulating Washer drg. No. S-8640/1 -04 Nos, 3) Insulating Washer drg. No. S-8640/2 -02 Nos, 4) Insulating Bush drg. No.S-23199 -10 Nos, 5) Insulating Bush drg. No. S-3463 -1 No, 6) Insulating Bush drg. No. S-22179-02 Nos, 7) Insulating Bush drg. No. S-8912 -02 Nos, 8) Insulating Plate drg. No. S-3404 -02 Nos, 9) Insulating Bush drg. No. S- 8813-04 Nos, 10) Insulating Plate RH Drg. No. S-3592 -01 Nos, 11) Insulating Plate LH Drg. No. S- 3593 -01 Nos. Inspection: Consignee | — | — | — | 2,86,516.5 | |
| — | 50.00 | — | — | ||
| Supply & Installation of Panel Domino Cover Plate with Button Assembly with writing & painting for operating panel of reputed make compatible with existing panel and as per site engineer. Inspection Consignee | — | — | — | 22,538 | |
| — | 200.00 | — | — | ||
| Panel Push Button Comptt. Assembly Grey, RED, Black, Yellow of reputed make compatible with existing panel and as per site engineer. Inspection- Consignee | — | — | — | 9,584 | |
| — | 10.00 | — | — | ||
| Panel Veeder counter 24 V with wiring & all accessoriesof reputed make compatible with existing panel and as per site engineer. Inspection- Consignee | — | — | — | 35,051.9 | |
| — | 10.00 | — | — | ||
| Supply of Complete domino (54x34mm) LN-REL YN-LOCKS D domino with 2 buttons indication wiring 1.15 mtr and fitted with 24 V DC LED Lamps of reputed make compatible with existing panel and as per site engineer. Inspection- Consignee | — | — | — | 24,903.9 | |
| — | 10.00 | — | — | ||
| SUPPLY OF 21/23 KHZ TX coils 15 mtr cable length assembly suitable for CEL make SSDAC as per RDSO Specification No. RDSO/SPN/177/2012 (Ver.3) or latest. Inspection- RDSO | — | — | — | 1,69,133.3 | |
| — | 10.00 | — | — | ||
| SUPPLY OF 21/23 KHZ RX coils 15 mtr cable length assembly suitable for CEL make SSDAC as per RDSO Specification No.RDSO/SPN/177/2012 (ver.3) or latest. Inspection- RDSO | — | — | — | 1,65,200 | |
| — | 50.00 | — | — | ||
| Supply of Limit Switches New Top Roller Type with 2 NO +2 NC Contacts suitable for existing installation of Electric lifting barrier. Inspection- Consignee | — | — | — | 55,684 | |
| — | 1500.00 | — | — | ||
| Supply of power cable 3 core 2.5 sqmm multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for railway electrification area shall be of reputed make like Delton, LAPP, Finolex, or superior. Inspection: Consignee | — | — | — | 48,720 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .