Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC Beiing L1 | |
| 2 | L2₹28.3 L+₹1.8 L (6.60%)Rejected-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹37.7 L+₹11.1 L (42.0%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹38.7 L+₹12.2 L (46.0%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹40.3 L+₹13.8 L (52.1%)Rejected-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L5 | Rejected-AOC Other than L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
21 Sept 2023, 6:00 pmClosed
Maj Mathews M Shepherd
GE (WEST) MATHURA
REWIRING OF CERTAIN BLDGS AND MAINTENANCE OF FIRE ALARM AND OVER HEAD CRANE SYSTEM IN SECTOR B MD AND OTM ACCN UNDER GE WEST MATHURA
2023_MES_612813_2
8300/1187/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) MATHURA
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹80,000
Yes
26 Oct 2023
31 Aug 2023
28 Sept 2023
31 Aug 2023
21 Sept 2023
7 Sept 2023
Amount
Taking down surface/concealed copper/aluminium point wiring (light, bell, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators, tubelight fittings etc and making good disturbed surfaces with plaster on walls, floors etc complete all as specified and as directed.
M&L for point wiring complete with 2.5sqmm single core FRLSH ISI marked PVC insulated cable with multi stranded copper conductor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for concealed conduit as directed at site including chase cutting for one light/fan point controlled by one switch including MS sheet sunken box concealed in wall duly painted inside with one coat of red oxide primer and two coats of black bituminous paint in out side with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 2.5 sqmm multi stranded FRLSH, PVC insulated copper cable as continuous earth connected to comman earth and earth dolly including making good the disturbed surfaces complete all as specified and directed.
All as per item No 2.00 (here-in-before) but for one light point controlled by two way switchs complete all as specified and directed.
All as per item No 2.00 (here-in-before) but for bell point controlled by bell push complete all as specified and directed.
All as per item No 2.00 (here-in-before) but for one socket outlet 5 pin, 5amps on the independent board but below/beside the switch board of light points in the same vertical/horizontal plane complete all as specified and directed.
All as per item No 2.00 (here-in-before) but for one 5 pin socket outlet 5amps point controlled by one switch on independent board.
All as per item No 2.00 (here-in-before) but for one 5 pin socket outlet 5amps point controlled by one switch on the same board with other switches.
All as per item No 2.00 (here-in-before) but for one 6 pin socket outlet 16amps point controlled by one switch on independent board.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and in existing surface / recessed PVC conduit and connecting incoming/outgoing electric connections and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unserviceable submain wiring and making good disturbed surfaces complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and in existing surface / recessed PVC conduit and connecting incoming/outgoing electric connections and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable as earth conductor including taking down old unsv submain wiring and making good the disturbed surfaces complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 10 sqmm single core PVC insulated but unsheathed multistranded copper conductor HRFR 1100 volts grade cable drawn through and in existing surface / recessed PVC conduit and connecting incoming/outgoing electric connections and one run of 10 Sqmm single core PVC insulated but unsheathed multistranded copper conductor HRFR 1100 volts grade cable as earth conductor including taking down old unsv submain wiring and making good the disturbed surfaces complete all as specified and directed. Note: Two runs of 10 Sqmm cable, one run of 10 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 4 runs of 10 sqmm single core PVC insulated but unsheathed multistranded copper conductor HRFR 1100 volts grade cable drawn through and in existing surface / recessed PVC conduit and connecting incoming/outgoing electric connections and one run of 10 Sqmm single core PVC insulated but unsheathed multistranded copper conductor HRFR 1100 volts grade cable as earth conductor including taking down old unsv submain wiring and making good the disturbed surfaces complete all as specified and directed. Note: Four runs of 10 Sqmm cable, one run of 10 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
Supply and laying in replacement of Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade, size 25 mm dia including all fittings like bends, elbow reducer, junction, coupler boxes, tee bell mouth etc for protection of cables/wires complete in all respect as specified and directed.
Supply and laying in replacement of Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade, size 20 mm dia including all fittings like bends, elbow reducer, junction, coupler boxes, tee bell mouth etc for protection of cables/wires complete in all respect as specified and directed.
Supply and laying in replacement of worn out PVC rigid conduit with uPVC trunking/casing caping of size 50mm x 16mm including fittings conforming to IS 14927/2001, fixed to wall/ceiling surface to cover the cable/wire complete all respect as specified and directed.
M&L for cutting chases, pining in making good to facing where required and pointed in CM (1:3) to ends or edges of brick wall etc and cutting chases for concealed conduit wiring etc and making good, match with existing surfaces by applying white/colour wash cutting not exc 10cm girth complete all as specified and directed.
S&F switch piano flush button single pole, one way 6 Amp 240 Volt complete all as specified and directed.
S&F switch piano flush button single pole, one way 16 Amp 240 Volt complete all as specified and directed.
S&F switch piano flush button single pole, two way 6 Amp 240 Volt complete all as specified and directed.
S&F bell push flush type 5 Amp 240 Volt complete all as specified and directed.
S&F socket 6 amps 5 pin flush type, 230 volts complete all as specified and directed.
S&F socket out let, 6 pin 6 and 16 amps multi purpose 2 in 1 flush type 230 volt complete all as specified and directed.
S&F in repair sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20A 240 Volt complete with one single pole MCB of cap 20/25 A, C series complete all as specified and directed.
S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed.
SS&F fan regulator electronic, five step type hum free suitable control speed of fan from 0 to 100% and connecting electrically all as required complete all as specified and directed.
S&F Angle/ batten holder polycorbonate type body suitable for batten fitting complete all as specified and directed.
S&F adaptor, 240 volts polycorbonate type body for proper connection to LED batten through batten holder complete all as specified and directed.
S&F in replacement musical door bell (having locking features) including 2 Nos, AA 1.5 volt battery for working even when no electricity suitable for 230 volts AC supply complete all as specified and directed.
S&F in replacement sketch fitting with decorative, wall mounting, brushed nickel finish fixture with acrylick diffuser including fixing 12 watt rechargable/invertor LED lamp, B22 base cap complete all as specified and directed.
Supply & fixing in replacement tube light fitting with surface and wall mounted decorative ultra slim round profile LED lighting fixture, 20 watt LED with entruded polycarbonate, environment friendly, energy efficient ready to use with polycarbonate diffuser & integrated electronic driver complete all as specified and directed.
Supply & fixing in replacement bulk head decorative LED light fitting of 10 W, IP - 66, environmental friendly, ultra modern, energy saving, surface mounted complete all as specified and as directed.
Supply & fixing in replacement tube light fitting with surface and wall mounted decorative ultra slim round profile LED lighting fixture, 10 watt LED with entruded polycarbonate, environment friendly, energy efficient ready to use with polycarbonate diffuser & integrated electronic driver complete all as specified and directed.
Supply & fixing in replacement security light with LED street light, 30 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class-I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13 alongwith replacement of old arm with single arm bracket OD 58 mm (max) with clamp, nut, bolts etc mounted on wall complete in all respect complete all as specified and directed.
Supply & fixing in replacement ceiling light with 40W Watt, 6500 K, slim LED panel 2' x 2' LED panel for recessed on ceiling) dust-free installation with high brightness LEDs for glare-free homogenous illumination with driver and all other connected accessories complete all as specified and directed.
Supply & fixing in replacement sheet metal enclosure MCB distribution board triple pole & neutral 415 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply & fixing in replacement sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply & fixing in replacement sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply & fixing in replacement of PVC enclousure with surface mounted PVC/gang box, 2 module including fixing of one 06 Amp piano switch & one 6 Amp, 5 pin socket out let complete all as specified and directed.
Supply & fixing in replacement of PVC enclousure with surface mounted PVC/gang box, 4 module (double) including fixing of two 06 Amp piano switch & two 6 Amp, 5 pin socket out let complete all as specified and directed.
Supply & fixing in replacement of PVC enclousure with surface mounted PVC/gang box, 6 module including fixing of five 06 Amp piano switch & one 6 Amp, 5 pin socket out let complete all as specified and directed.
Supply & fixing in replacement of PVC enclousure, surface mounted, totally enclosed (including 16 Amp switch socket) with 6A/16A, switch & socket combined having 4 fixing holes complete all as specified and directed.
Supply & fixing MS ring hook (I hook) fastener, M-12 size including drilling on RCC roof for fixing ceiling fan complete all as specified and directed.
Supply & fixing in replacement PVC round/circular lid of 65 mm dia including MS screw for covering / closing wiring junction complete all as specified and directed.
Supply & fixing in repair PVC space bar saddle with screw for 20 mm dia conduit on existing wall/ceiling for proper fixing of sagged conduit complete all as specified and directed.
Supply & fixing in replacement of MCB, 415 Volt, 10 KA, 4 Pole, 100 Amps, C series complete all as specified and directed.
Supply & fixing in replacement of MCB, 415 Volt, 10 KA, 4 Pole, 63 Amps, C series complete all as specified and directed.
Supply & fixing in replacement of MCB DP, 240 Volt, 10 KA, 40 Amps, C series complete all as specified and directed.
Supply & fixing in replacement of MCB DP, 240 Volt, 10 KA, 63 Amps, C series complete all as specified and directed.
Supply & fixing in replacement of MCB single pole 240 volt any rating from 6 to 32 amps, C series with rupturing capacity 10 KA complete all as specified and directed.
Supply and fixing in replacement of burnt conventional fans with BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 8.40, (26W±10%) with or without remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed. Note : Old unserviceable ceiling fan shall be deposited in AGE E/M store yard.
Supply and fixing in replacement water heater (Geyser) 25 ltr capacity in 5 Star rating, digital display, feather touch panel, shock safe plug, incoloy glass coated element, feroglass technology, PUF insulation 0.8 Mpa high working pressure, Whirlflow technology, IPX-4 protection suitable for, 50 Hz, AC 240Volt, single phase supply, white blue with overall length approx 620 mm with wall mounting accessories & 02 Nos SS braided (SS-304) connection pipe 600mm long complete all as specified and directed. Note : Old unserviceable water heater (Geyser) shall be deposited in AGE E/M store yard.
Providing visiting charges / maintenace services for addressable fire alarm & detection system, fire fighting system / equipment installed at various locations to ensure system serviceability at all the time. Note:- (i) The cost of minor spares & consumable items etc shall be included in above quoted rates. (ii) The cost of major or special repair of overhauling of any equipment such as fire pump, motor, fire alarm panel, battaries, hooter, detectors, hooters, manual call point including winding of motor is not covered in the scope of work. However, preventive & routine maintenance including servicing, minor repair / rectification will be responsibility of contractor/firm.
Supply, installation, testing and commissioning in repair of addressable multi detector with base with binary coded address setting, dual LED's for 360 visibility, polarity free, sleek low profile housing design. regular 100mm base, IP rating -42 complete all as specified and directed.
Supply, installation, testing and commissioning in repair of addressable Heat detector with fixed temperature of 59°C and ROR feature to raise and alarm when the temperatures raises 11.1 per minute, shall have binary coded address setting, dual LED's for 360 visibility, non polarised, sleek low - profile housing design, regular 100mm base, IP rating : IP-42 complete all as specified and directed.
Supply & fixing in repair of manual call point - single action/dual action - with back box and break glass rod, shall be resttable by align key to avoid unauthenticated restorations all as specified and directed.
Supply and fixing in repair of addressable electronic sounder cum strobe with 24V DC, Audiable sound 85 db @ 1 mtr range. It is used for fire, Burglar & Emergency alarm system, Low current consume @ 25 mA out put 2 different tone audiable sound as per existing sample complete all as specified and directed.
Suppy & fixing in replacement of Sealed Lead Acid battery, 12 volt, 7.0 AH maintenance-free, leak proof, with suitable copper terminal as per existing including making connections to existing circuit of fire alarm system/panel complete in all respect and as directed.
Supply & fixing in replacement multi core 7 x 1.5 sqmm copper conductor cable, circular in shape PVC insulated, PVC sheathed suitable for 1100 volt, 50 Hz, ISI Mark all as specified and directed.
Supply & fixing in replacement multi core 3 x 2.5 sqmm copper conductor cable, circular in shape PVC insulated, PVC sheathed suitable for 1100 volt, 50 Hz, ISI Mark all as specified and directed.
Supply & fixing in repair of LED constant current driver suitable for 2' x 2' LED luminaires of wattage from 31 to 40 watt, 25 to 42 Volt DC including fault detection, soldering and testing complete in all respect and as directed.
Supply & fixing in repair of LED constant current driver suitable for LED tube/batten of wattage from 18/20 watt, input voltage range - 110 to 280 Volt AC, out put voltage range - 40 to 75 Volt DC including fault detection, soldering and testing complete in all respect and as directed.
shyam construction
CUCKOO ENTERPRISES
ASHOK INFRATECH
Ms Kamal Kant Agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .