| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹7.8 L+₹15,462 (2.03%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹8.4 L+₹76,456 (10.0%)Rejected-Finance HOUSE NO 59 THILIXU VILLAGE BLOCK V PS POST DIMAPUR NAGALAND 797 112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹8.4 L+₹78,359 (10.3%)Rejected-Finance C O HILL HARDWARE STORE P R HILL KOHIMA NAGALAND | PHEK | NAGALAND | 797104 | L4 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
8 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Zakhama
AGE (I) Zakhama C/o 792 FPO PIN-900792 C/O 99 APO
REPAIR/MAINT OF DG SETSOF VARIOUS RATING,COOLING APPLIANCES AND THEIR VOLTAGE STABILIZERS AT ZAKHAMA MIL STN
2020_MES_393621_1
8908 repair DG sets cooling zak
Open Tender
Civil Works
Item Rate
180 days
ZAKHAMA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE I Zakhama
₹15,000
Yes
29 Jun 2021
9 Nov 2020
10 Dec 2020
9 Nov 2020
8 Dec 2020
24 Nov 2020
60 days
Amount
Material and labour for carrying out ' B ' check Maintenance for Jackson Make 125 KVA DG Set complete i.e engine & generator ( Silent type), air-cooled,including replacement of LO filter, Fuel filter, By pass filter, cleaning of air filter using pressure air, seperator for fuel water, inhibitor corrosin, O ring, Gaskets, screws etc and draining out old engine oil from oil chamber and removing deposited material including applying grease, CRC in moving parts and draining out water from radiator assembly and refill new after mixing with coolant including tightening all inlet and outlet connections and replacing minor items such as hose clamp, screws, washers etc all as specified and directed by Engineer in charge . NOTE : 1. Rates are inclusive of valvoline premium blue 7800 plus engine oil of reqd qty. 2. The 'B' check will be carried out by auth representatives of DG Set manufacturer complete all as specified and directed by Engineer in charge. 3. Quoted rates includes fright charges.
All as per Item No. 01 but make - Sudhir 125 KVA capacity complete as specified
M&L for Routine maintenance consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of 75/70 KVA DG , make : kirloskar/ cummins, water cooled type dg Set complete i.e. Engine, Alternator etc for efficient functioning including provision of all consumables items like cotton, waste cloth, kerosene oil etc for repair. Maintenance will be carried out all as specified for various capacity DG Sets here-in-after and as directed. (a) Changing of engine oil. (b) Checking clearance of suction and exhaust valves and adjust if required. (c) Changing of oil filter, fuel filters, screen filters assy. (d) Changing of water filter element. (e) Topping up of coolent. (f) Changing of Hydraulic governer oil. (g) Tightening of all nut bolts. (h) Greasing of all points. (i) Checking of any leaking in fuel and oil lines. (j) Cleaning of fuel tank by taking out the dirt and sludge, cleaning the tank thoroughly. (k) Adjusting valve tappet clearence/timing. (l) Injector pressure test cleaning and repairing, tightining fasteners and making lubrication leak proof. (m) Repair/rewiring of broken/damaged control panel connection including measuring instruments, indicators, engine proction devices etc.
Note : (i) DHPP (N), lub oil, engine oil required at the time of maintenance/testing will be provided by the department. (ii) Labour charges for dismantling/taking down and replacement/refixing of new spare parts as and when required is deemed to be included in unit rate quoted. (iii) Spare parts like oil filter, fuel filter, screen filter by pass filter , water filter rates are inclusive in the quoted rates. (iv) Any other spare parts required will be paid seperately under supply only. (v) The work should be carried out by auth rep or as directed by Engr-in-Charge.
M&L for carrying out Overhauling of engine of DG Set, capacity 70/75 KVA, 1500 RPM water cooled/air cooled type, engine of make : /Kirloskar/HA consisting of the following works :- (a) Dismantling engine parts in presence of MES representative and display all the parts/components of engine for inspection of Engineer-in-charge to asertain the serviceability of existing parts. (b) Detecting leakage of lubricating oil and water of the engine and rectification of fault by replacing worn out parts. (c) Cost includes replacement of top & bottom gaskets, all type of filters, repair the head assembly by adjusting valves & replacement of worn out components after dismantling. (d) Taking out old unserviceable/ leakage radiator from the engine and making servicable and refixing as per existing complete. (e) De-carbonising and degreasing of all the parts such as piston assembly, heads, crank case, crank shaft, oil pump etc and checking of all rotary and static parts (existing) for smooth functioning. (f) Assembling of engine complete with old serviceable parts and replacement of unserviceable parts by new parts as directed by Engr-in-Charge. (g) Testing of DG Set after repair as per the direction of the Engineer-in-Charge.
Note :- (i) Parts required to be replaced during overhauling/repair of engine shall be measured and paid separately under appropriate items as 'Supply only'. (ii) Any machine work to the existing parts which is felt essential for smooth functioning of DG Set shall be measured and paid separately under appropriate item. (iii) Any minor parts such as screw, washer, split ring, circlips etc shall be supplied by the Contractor and rate for the same shall be deemed to be included in the unit rate quoted. (iv) Fuel and lub oil for testing of DG Set after repair and also when necessary shall be supplied by the department .
Material and labour for taking out self starter 12 volt from the DG Set, transporting to workshop, opening/disconnecting all internal connections, cleaning the same, taking out burnt armature, segrigation of serviceable parts for re-use, rewinding of armature with copper wire of existing size. Reassembling the same with replacement of following items and testing on completion for efficient functioning complete all as specified and directed by Engineer-in-charge:- (a) Carbon brush 01 Set. (b) Beadex pinion 01 no. (c) Half clutch assy 01 No. (d) Field coil 01 No. (e) Slonoid switch 01 No. (f) Commutator 01 nos.
All as per Item No. 05 above but 24 volt self starter complete as specified and directed.
Supply and fixing Battery terminal cable, copper conductor multi strand, unsheathed, single core 25 sqmm, 1.5 metre long fixed with copper terminals on both side suitable for 12 Volts & upto 180 AH battery. complete all as specified and directed by Engineer-in-charge
Material and labour for dismantling the unserviceable radiator for DG Set of 70/75 kva DG capacity from engine, transportation to the workshop, repairing the tank/storage portion including necessary welding & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping Set incl replacement of defective copper core and reassembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket Sets including refixing and testing for efficient functioning complete all as specified and directed by Engineer-in-charge
Material and labour for finding out defects of fully Automatic Electric panel (AMF) of DG Set of capacity 125 KVA and taking out burnt interconnection wiring, unserviceable components and serviceable components for reuse, including rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut bolt washer of various sizes refixing serviceable items and replacement of Contactor of any Model and amps capacity, 240 volt coil of any Make and Part No. and testing for efficient functioning complete all as specified and directed by Engineer-in-charge
Preparation of Old Painted Surfaces of 70./75 KVA DG Set and applying with Two Coat of Grey Synthetic Enamel Paint on Engine and Alternator Body and Two Coat of Red Synthetic Enamel Paint on Fan Guard and Two Coat of Black Synethic Enamel Paint on Base Channel Frame of the DG Set painted with Spray Painting Machine, complete all as specified and as directed.
Supply fixing GI pipe 40/50 mm dia light grade including fittings as required for extending/replacement exhaust pipe complete all specified and directed.
Taking out/ Dismantling of asbestos rope from exhaust pipe & Supply and Binding Asbestos Ropes on Exhaust Pipe of DG Set and plastered with Plaster of Paris on the of binding Ropes of Exhuast Pipes suitable for 70/75.0 KVA DG Set of MAKE : KIRLOSKAR, as approved.
Repair and servicing of fuel injection pump by replacing fuel pump repairs kit and calibration complete suitable for //Kirloskar make Engine of capacity 70/75 KVA
Repair and servicing of lub oil pump assembly including replacement of oil pump repair kit with new one for //Kirloskar make engine
Supply only V belt No. B-42/49/50 (Provisional) for Kirloskar engine as per existing make and model
Supply only V belt No. A-48/A-49/A-56 (Provisional) for Kirloskar / Cummins engine as per existing make and model
Supply only Gauge lub oil pressure (Provisional) for //Kirloskar engine as per existing make and model
Supply and fix temperature gauge/Sensor including connected cables (Provisional) for //Kirloskar engine as per existing make and model
Supply and fix Ignition switch with key (Provisional) for //Kirloskar engine as per existing make and model
Supply and fix Lub oil pressure pipe (Provisional) for //Kirloskar engine as per existing make and model
Supply only Ring bottom sealing (Provisional) for //Kirloskar engine as per existing make and model
Supply only Liner cylinder (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model.
Supply only Gasket Set complete (Provisional) suitable for kirloskar/cummins engine of Capacity 70 KVA as per existing make and model.
Supply only CR end bearing (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model.
Supply only Main bearing (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model.
Supply only Piston (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Intake valve (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Exhaust valve (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Valve guide (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Valve seat (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Thrust washer (Provisional) suitable for kirloskar/cummins engine of Cap 70/75 KVA as per existing make and model
Supply only Oil seal for crank shaft rear (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Oil seal for crank shaft front (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Injector nozzle (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Bush for cam shaft (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Copper washer for injector (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only Piston ring Set (Provisional) suitable for kirloskar/cummins engine of Capacity 70/75 KVA as per existing make and model
Supply only rectifier plate type electronic suitable for 70/75 KVA DG Set as per existing make and model
Supply only of voltage regulator (cutout) 12 volt for battery charging system as per existing make and model
S&F silencer complete with fixing clamp as per existing make and model including taking down old one as directed.
S&F connecting Rod for // Kirloskar engine including taking down old one as directed.
S&F voltmeter 0-500 volts, 3 phase (Make : AE/L&T/ESSMA) square type (SR-144) including taking down old one as directed
S&F Ampere meter 0 to 60 Amp of Make : ESSM/AE/L&T (SR 144) including taking down old one as directed
S&F PVC flexible pipe 15mm bore with fixing clamps including taking down old one as directed.
M&L for rewiring to panel board of DG Set 70/75 KVA with PVC insulated, multistranded copper conductor, cables, single core, 1100 volt grade, 10 Sqmm complete with thimble/lugs as required and directed
All as per item No 54 above but capacity 70/75 KVA
S&F asbestos rope 1/2" size and steel wire mess and wrapped all around the silencer pipe over a layer of plaster of paris with proper fixing materials superior quality as required and directed
Supply and installed Battery charger 12/24 volt suitable for 180 AH Amps battery complete all as specified and directed. (Make : IRI or equivalent as approved)
Taking down old/unserviceable feild coil from the alternator assembly of DG Set of capacity 70/75 KVA, cutting, welding and rewinding the field coils with best quality new super enamelled copper wires as per existing gauge of weight 29 kg (Appx), insulation material, varnishing, heating the same upto rated tempaerature, reassembling the field coil in the existing position, commissioning and testing complete all as required and directed by the Engr-in-charge
Supply only following parts for routine maintenance of various rating of DG Sets:-
Fuel filter as per sample for 125 KVA DG Set
Lub oil filter as per sample for 125 KVA DG Set
Air cleaner element as per sample for 125 KVA DG Set
Fuel filter seperator as per sample for 125 KVA DG Set
Fuel filter as per sample for 75 KVA DG Set
Lub oil filter as per sample for 75 KVA DG Set
Air cleaner element as per sample for 75 KVA DG Set
Fuel filter as per sample for 70 KVA DG Set
Lub oil filter as per sample for 70 KVA DG Set
Air cleaner element as per sample for 70 KVA DG Set
Distilled water for DG Set battery in bottle
Premium Blue Engine oil SAE-15W/40
Coolent
Battery of Cap. 12 Volt 70 AH for DG Set
Battery of Cap. 12 Volt 125 Ah for DG Set
Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of any make from split type AC and S&F New compressor suitable for Split AC of capacity 1.5 Ton complete all as specified and directed by Engineer in Charge .
M&L for testing leakage in system Split type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed by Engineer in Charge
All as per item No 2 here-in-before but Split type Air conditioner of 2.0 ton capacity complete all as specified and directed by Engineer in Charge
M&L for taking down Air-Conditioner split Type of any capacity and make from its existing location by disconnecting electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Parts/ petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department . (c). Spare parts alongwith Refrigerant gas shall be measured and paid separately under respective item of the schedule.
The following items supply only :-
Starting capacitor of capacity 80/100 MFD (for 1.5 TR AC)
Starting capacitor of capacity 100/120 MFD (for 2 TR AC)
Remote with PCB circuit for 1.5 Ton Capacity Split AC
Blower motor suitable for 1.5/2.0 Split type AC
Swing motor suitable for 1.5 Ton Capacity Split type Air Conditioner
Over load relay suitable for 1.5/2.0 Ton Split type AC
Air Filter Suitable for 1.5/2.Ton Capacity Split type Air conditioner
Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC
Thermostat switch with knob suitable for AC of any capacity.
Capillary & filter for split AC
M&L repair & replacement of new Suction pipe suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed by Engineer in Charge
M&L for replacement of damaged Insulation of size 1/4&3/8 for Split AC complete as per existing site complete all as specified and directed by Engineer in Charge
M&L for replacement of Rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed by Engineer in Charge
M&L for replacement of Copper Tube of size 1/4 suitable for any type and any capacity Air conditioner complete all as specified and directed by Engineer in Charge
M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete
Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of any make for refrigerator capacity of 185 to 255 Ltrs complete all as specified and directed.
Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of any make for refrigerator capacity of 300 Ltrs complete all as specified and directed..
Taking down parts of Refrigerator of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item.
The following items supply only :-
Magnetic door gasket suitable for 165 to 200 ltrs capacity Refrigerator
Magnetic door gasket suitable for 255 to 310 ltrs capacity Refrigerator
Freezer suitable for 165 to 200 ltrs capacity Refrigerator
Freezer suitable for 255 to 320 ltrs capacity Refrigerator
Supply only thermostat switch to match with the existing item suitable for refrigerator of any capacity.
Supply only over load protector suitable for refrigerator to match with the existing design.
Air Filter suitable for for any make and any capacity Refrigerator
Capillary tube of suitable length as per existing size for refrigerator any make and any capacity
Vegitable tray as per sample and suitable for refrigertator any type and any make
PVC Stand for Refigerator capacity any make and any capacity as per sample
M&L for removing burnt/defective sealed compressor unit of any make from Capacity 400 Ltr of Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed at site by the Engr-in-Charge.
Taking down parts of Deep freezer of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item.
The following items supply only :-
Supply only open type relay as per existing one upto 310 Ltr capacity Deep freezer
Supply only thermostat switch to match with the existing item suitable for Deep freezer of any capacity.
Supply only over load protector suitable for Deep freezer to match with the existing design.
Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complte
Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity
Starting relay suitable for 400 ltr capacity Deep freezer
Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer Make; AUE/Cool Blow/Universal
Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer
M&L for repair to Voltage stablizer of capacity 0.5/1.0/2.0KVA, dismantling the unserviceable parts of voltage stablizer ,checking the general servicing complete all as specified and directed.
All as per item No.17.00 here in before but voltage Stablizer of capacity 3/4/5 KVA complete all as specified and directed. Item Serial No. 17.00 & 18.00 (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed (ii). Spare parts shall be measured and paid separately there rate above Rs. 100/
The following items supply only :-
Trigger transformer for the existing capacity of stabilizer any make and any capacity
Circuite plate for the existing capacity of stabilizer any make and any capacity
Cut out of 15 Amps for the existing capacity of stabilizer any make and any capacity
Volt meter indicating 100-300 Volt for the existing capacity of stabilizer any make and any capacity
Transformer suitable for 0.5/1.0 Voltage Stabilizer
Transformer suitable for 2/3 KVA Voltage Stabilizer
Transformer suitable for 4/5 KVA Voltage Stabilizer
PVC insulated and PVC over all covered cord cable copper conductor 3 core of size 4 Sqmm Make- Plaza/Havells/ Finolex.
Taking down the unserviceable Sheet metal enclosure and supply and fix Sheet metal enclosures with flush mounted type ply and socket with 240 V SP MCB 20 amps Capacity Make: ABB/Legrand/Havells or Equivalent
Taking out the Unserviceable defective Voltage Stabilizer of capacity 3.0 KVA and S&F of the new Voltage Stabilizer with connected wiring with accessories complete all as specified and directed by Engineer -in-Charge
All as item No. 20 here in before but 4/5 KVA Capacity Make: V GUARD/VOLTAS/VENUS etc
Labour only for charging refrigerent gas R-22/R-410A/R-134(a) for Refrigerator/Deep freezer/Water cooler/Window and split type Air conditioner after duly rectifying leakages by welding/brazing and testng by charging N2 gas for 24 hours complete all as specified and directed . Note:- Refrigerant gas to be measured and paid separately under relabent items of this schedule
Supply only Refrigerant gas R-22 as exhisting Split/ Air Conditioner and water cooler anytype and any capacity complete all as specified and directed by Engineer-in-Charge
Supply only Refrigerant gas R-410A as exhisting Split/ window type Air Conditioner and water cooler anytype and any capacity complete all as specified and directed by Engineer-in-Charge
Supply only Refrigerant gas R-134(a)in refrigerator and deep freezer of any capacity complete all as specified and directed at site by the Engr-in-Charge.
Taking down carefully unserviceable Sub main wiring including unserviceable fittings such as switches, ceiling roses, regulators etc complete and making good disturbed surfaces of walls, floors etc.complete all as specified and as directed by Engineer-in charge.
M&L for sub main wiring with 4 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed.complete all as specified and as directed by Engineer-in charge.(Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.)
M&L point wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2.5Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches as specified and directed. complete all as specified and as directed
Taking down voltage stabilizer and removing of burnt coil winding with new super enemeled copper winding as per existing gauge including burnishing, drying alongwith replacement of UNSV spares of voltage stabilizer capacity 4/5 KVA and reassembling complete all as specified and as directed.
All as per above item No 29 but Capacity upto 2 KVA
MS SADHNA RAHUL
Shri Atoshe Tuccu
thepfuralie zutso
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .